43 resultados para High spectral resolution detectors


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, a new computational scheme for solving flows in porous media was proposed. The scheme was based on an improved CE/SE method (the space-time Conservation Element and Solution Element method). We described porous flows by adopting DFB (Brinkman-Forchheimer extended Darcy) equation. The comparison between our computational results and Ghia's confirmed the high accuracy, resolution, and efficiency of our CE/SE scheme. The proposed first-order CE/SE scheme is a new reliable way for numerical simulations of flows in porous media. After investigation of effects of Darcy number on porous flow, it shows that Darcy number has dominant influence on porous flow for the Reynolds number and porosity considered.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

根据石英晶体双折射率的色散特性,对石英波片的偏光干涉谱进行了理论分析和数值模拟,提出了一种石英波片延迟量和厚度的偏光干涉标定法。即由偏光干涉谱,可以得出石英波片在200~2000 nm宽光谱范围内的延迟量;通过对长波段的偏光干涉谱极值波长的精确判断,可以准确地计算出该石英波片的厚度。利用Lambda 900 紫外可见近红外分光光度计对一片石英波片的偏光干涉谱进行了测量。在波长精度为0.1 nm的情况下,测量的厚度精度为0.1 μm。误差分析结果表明,通过提高光谱的最小分辨力及选择较长的光谱波段进行测量计算

Relevância:

100.00% 100.00%

Publicador:

Resumo:

采用一种特殊的二次光栅用于激光波前测量, 它对非零级衍射光束具有不同的聚焦效应, 其光栅线为圆弧型而非直线。导出了在会聚光束情况下的两平面成像在单一像平面上的距离关系, 实验上实现了二次光栅用于会聚光束的波前测量, 测量得到会聚光束具有较大的散焦(-2.93λ)和球差(1.34λ), 与该透镜引起波前的离焦像差理论理想值(-2.695λ)基本符合。该技术可以实现波前的高空间分辨力和高精度实时测量, 大大减少光学元件数量, 降低装置成本。由于大功率激光束的不稳定性, 其波前变化非常快, 所以该方法的实时性非

Relevância:

100.00% 100.00%

Publicador:

Resumo:

提出了一种新型的基于电光调制的激光光谱整形方案,该整形技术可以减轻啁啾脉冲放大系统中的增益窄化效应。傅立叶变换限的宽带种子激光脉冲通过光学展宽器线性展宽后,耦合到加载有整形电脉冲的集成波导调制器中进行整形,整形电脉冲由孔径耦合带状线电脉冲发生器产生。由于线性啁啾脉冲时间-频率的直接对应关系,在时域内对宽带种子激光脉冲整形,其光谱也得到了同样形状的整形。模拟了整形光谱形状,相应的整形电脉冲波形,分析了该整形技术的光谱整形分辨率,以及整形过程中引入的相位畸变。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An atomic force microscope (AFM) assisted surface plasmons leakage radiation photolithography technique has been numerically demonstrated by using two-dimensional finite-difference time-domain (2D-FDTD) method. With the aid of a metallic AFM tip, particular characteristic of the Kretstchmann configuration to excite surface plasmons (SPs) is utilized to achieve large-area patterns with high spatial resolution and contrast, the photoresist could be exposed with low power laser due to the remarkable local field enhancement at the metal/dielectric interface and the resonant localized SPs modes near the tip. Good tolerance on the film thickness and incident angle has been obtained, which provides a good practicability for experiments. This photolithography technique proposed here can realize large-area, high-resolution, high-contrast, nondestructive, arbitrary-structure fabrication of nanoscale devices. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Phosphate glasses 60P2O5-15CS2O- 15Al2O3-10BaO were made by high temperature melt-annealing method. The absorption spectra, excitation spectra and emission spectra of Gd3+-Tb3+ and Ce3+-Gd3+-Tb3+ co-doped phosphate glass 60P2O5-15CS2O- 15Al2O3-10BaO were studied. The experimental results indicate that, the doping of Ce3+ and Gd3+ in Tb3+ phosphate glass has a good effect on the 545 nm emission of Tb3+ at UV excitation. The Ce3+-Gd3+-Tb3+ co-doped phosphate glass have a good x-ray luminescence at the radiation of x-ray with energy in 50-120 kev, and a high space resolution. The Ce3+-Gd3+-Tb3+ co-doped phosphate luminescence glass is a promising material for using in the digital radiography system in medical devices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

GaN films grown on sapphire substrate with an emphasis on epitaxial lateral overgrown (ELOG) layers with an array of rhombic shaped mask area as well as InGaN/GaN MQW laser diode layer structures were investigated by cathodoluminescence (CL) spectroscopy and CL imaging at room and low temperatures. The microscopic imaging with a high-spatial resolution clearly reveals the distribution of threading dislocations and point defects in ELOG GaN films. The secondary electron and CL data measured on cleaved faces of laser diodes are analyzed in consideration with luminescence mechanisms in semiconductor heterostructures and around the p - n junction, providing important information on the defects and carrier dynamics in laser diode devices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, recent progresses in optical analysis of dislocation-related physical properties in GaN-based epilayers are surveyed with a brief review. The influence of dislocations on both near-band edge emission and yellow luminescence (YL) is examined either in a statistical way as a function of dislocation density or focused on individual dislocation lines with a high spatial resolution. Threading dislocations may introduce non-radiative recombination centers and enhance YL, but their effects are affected by the structural and chemical environment. The minority carrier diffusion length may be dependent on either dislocation density or impurity doping as confirmed by the result of photovoltaic spectra. The in situ optical monitoring of the strain evolution process is employed during GaN heteroepitaxy using an AIN interlayer. A typical transition of strain from compression to tension is observed and its correlation with the reduction and inclination of threading dislocation lines is revealed. (c) 2007 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new type of interferometer, the moving-optical-wedge interferometer, is presented, and its principle and properties are studied. The novel interferometer consists of one beam splitter, two flat fixed mirrors, two fixed compensating plates, one fixed optical wedge, and one moving optical wedge. The optical path difference (OPD) as a function of the displacement of the moving optical wedge from the zero path difference position is accomplished by the straight reciprocating motion of the moving optical wedge. A large physical shift of the moving optical wedge corresponds to a very short OPD value of the new interferometer if the values of the wedge angle and the refractive index of the two optical wedges are given properly. The new interferometer is not so sensitive to the velocity variation of the moving optical wedge and the mechanical disturbances compared with the Michelson interferometer, and it is very applicable to low-spectral-resolution application for any wavenumber region from the far infrared down to the ultraviolet. (C) 2008 Optical Society of America.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Neutron induced defect levels in high resistivity silicon detectors have been studied using a current-based macroscopic defect analysis system: thermally stimulated current (TSC) and current deep level transient spectroscopy (I-DLTS). These studies have been correlated to the traditional C-V, I-V, and transient current and charge techniques (TCT/TChT) after neutron radiation and subsequent thermal anneals. It has been found that the increases of the space charge density, N-eff, in irradiated detectors after thermal anneals (N-eff reverse anneal) correspond to the increases of deep levels in the silicon bandgap. In particular, increases of the double vacancy center (V-V and V-V-- -) and/or C-i-O-i level have good correlations with the N-eff reverse anneal. It has also been observed that the leakage current of highly irradiated (Phi(n) > 10(13) n/cm(2)) detectors increases after thermal anneals, which is different from the leakage current annealing behavior of slightly irradiated (Phi(n) < 10(13) n/cm(2)) detectors. It is apparent that V-V center and/or C-i-O-i level play important roles in both N-eff and leakage current degradations for highly irradiated high resistivity silicon detectors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Osteocytes respond to dynamic fluid shear loading by activating various biochemical pathways, mediating a dynamic process of bone formation and resorption. Whole-cell deformation and regional deformation of the cytoskeleton may be able to directly regulate this process. Attempts to image cellular deformation by conventional microscopy techniques have been hindered by low temporal or spatial resolution. In this study, we developed a quasi-three-dimensional microscopy technique that enabled us to simultaneously visualize an osteocyte's traditional bottom-view profile and a side-view profile at high temporal resolution. Quantitative analysis of the plasma membrane and either the intracellular actin or microtubule (MT) cytoskeletal networks provided characterization of their deformations over time. Although no volumetric dilatation of the whole cell was observed under flow, both the actin and MT networks experienced primarily tensile strains in all measured strain components. Regional heterogeneity in the strain field of normal strains was observed in the actin networks, especially in the leading edge to flow, but not in the MT networks. In contrast, side-view shear strains exhibited similar subcellular distribution patterns in both networks. Disruption of MT networks caused actin normal strains to decrease, whereas actin disruption had little effect on the MT network strains, highlighting the networks' mechanical interactions in osteocytes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel method is reported for the detection of avian influenza virus subtype H5 using a biosensor based on high spatial resolution imaging ellipsometry (IE). Monoclonal antibodies specific to H5 hemagglutinin protein were immobilized on silicon wafers and used to capture virus particles. Resultant changes on the surface of the wafers were visualized directly in gray-scale on an imaging ellipsometry image. This preliminary study has shown that the assay is rapid and specific for the identification of avian influenza virus subtype H5. Compared with lateral-flow immunoassays, this biosensor not only has better sensitivity, but can also simultaneously perform multiplexed tests. These results suggest that this biosensor might be a valuable diagnostic toot for avian influenza virus detection. (c) 2009 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A high energy heavy ion microbeam irradiation system is constructed at the Institute of Modern Physics (IMP) of the Chinese Academy of Sciences (CAS). A quadrupole focusing system, in combination with a series of slits, has been designed here. The IMP microbeam system is described in detail. The intrinsic and parasitic aberrations associated with the magnets are simulated. The ion beam optics of this microbeam system is investigated systematically. Then the optimized initial beam parameters are given for high spatial resolution and high hitting rates.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The remote sensing based Production Efficiency Models (PEMs), springs from the concept of "Light Use Efficiency" and has been applied more and more in estimating terrestrial Net Primary Productivity (NPP) regionally and globally. However, global NPP estimates vary greatly among different models in different data sources and handling methods. Because direct observation or measurement of NPP is unavailable at global scale, the precision and reliability of the models cannot be guaranteed. Though, there are ways to improve the accuracy of the models from input parameters. In this study, five remote sensing based PEMs have been compared: CASA, GLO-PEM, TURC, SDBM and VPM. We divided input parameters into three categories, and analyzed the uncertainty of (1) vegetation distribution, (2) fraction of photosynthetically active radiation absorbed by the canopy (fPAR) and (3) light use efficiency (e). Ground measurements of Hulunbeier typical grassland and meteorology measurements were introduced for accuracy evaluation. Results show that a real-time, more accurate vegetation distribution could significantly affect the accuracy of the models, since it's applied directly or indirectly in all models and affects other parameters simultaneously. Higher spatial and spectral resolution remote sensing data may reduce uncertainty of fPAR up to 51.3%, which is essential to improve model accuracy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The electrospray ionization ion trap multiple-stage tandem mass spectrometry (ESI-MSn) and electrospray ionization Fourier transform ion cyclotron resonance multiple-stage tandem mass spectrometry (ESI-FT-ICR-MSn) have been applied successfully to the direct investigation of a number of dibenzocyclooctadiene lignan constituents from the methanol extracts of the Fructus Schisandrae in the positive ion mode. The detailed structural characterization of the same skeleton and different peripheral substituents had been studied and the precise elemental compositions of ions at high mass resolution had been obtained. So the fragmentation mechanisms could be clarified.