67 resultados para Error Vector Magnitude (EVM)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the process of interferometric testing, the measurement result is influenced by the system structure, which reduces the measurement accuracy. To obtain an accurate test result, it is necessary to analyze the test system, and build the relationship between the measurement error and the system parameters. In this paper, the influences of the system elements which include the collimated lens and the standard surface on the interferometric testing are analyzed, the expressions of phase distribution and wavefront error on the detector are obtained, the method to remove some element errors is introduced, and the optimization structure relationships are given. (C) 2006 Elsevier GmbH. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

引入角度偏差、位移偏差作为拼接光栅系统的物理参数,定义了拼接光栅的孔径函数,利用傅里叶角谱理论研究了高斯脉冲入射拼接光栅压缩器后的远场分布特性。研究表明;出射脉冲仍然是高斯型脉冲,但包络中心发生偏移,偏移量由角度偏差量和光束口径决定;位移偏差引入的相位随着拼接光栅压缩器传递,其对远场焦斑的影响,取决于每片子光栅的非整数倍光栅常数的横向位移偏差和纵向位移偏差的综合作用。通过数值计算得到了各维偏差对阵列光栅压缩器空域特性的影响,计算表明:光栅面外角度偏差(俯仰左右)和条纹平行度偏差都必须控制在1μrad以内,

Relevância:

20.00% 20.00%

Publicador:

Resumo:

在起偏器待测波片检偏器系统基础上提出一种四区域测量波片相位延迟量的方法。调整待测波片和检偏器的方位角,获得相应的四组光强值,通过线性运算得到待测波片的相位延迟量,完全消除了起偏器和检偏器不完全消光带来的误差。由于测量系统中不存在标准波片或其他相位调制元件,允许测量波长仅受偏振棱镜和探测器的限制,因此四区域法可适用于很大波长范围内的波片测量。以λ/4波片为例,理论分析了测量系统利用四区域测量法后的仪器误差为σ≤±3.49065×10-3rad(约0.2°),精度比原算法提高约1个数量级。实验验证了四区域法能有效提高系统精度。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Based on the generalized Huygens-Fresnel diffraction integral theory and the stationary-phase method, we analyze the influence on diffraction-free beam patterns of an elliptical manufacture error in an axicon. The numerical simulation is compared with the beam patterns photographed by using a CCD camera. Theoretical simulation and experimental results indicate that the intensity of the central spot decreases with increasing elliptical manufacture defect and propagation distance. Meanwhile, the bright rings around the central spot are gradually split into four or more symmetrical bright spots. The experimental results fit the theoretical simulation very well. (C) 2008 Society of Photo-Optical Instrumentation Engineers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The focusing properties of a concentric piecewise cylindrical vector beam is investigated theoretically in this paper. The beam consists of three portions with different and changeable phase retardation and polarization. Numerical simulations show that the evolution of the focal shape is very considerable by changing the radius and polarization rotation angle of each portion of the vector beam. And some interesting focal spots may occur, such as two- or three-peak focus, dark hollow focus, ring focus, and two-ring-peak focus. Corresponding gradient force patterns are also computed, and novel trap patterns, including cup shell shape trap with one trap at its each side along axis, rectangle shell shape trap with one trap at its each side, dumbbell optical trap, spherical shell optical trap, may occur, which shows that the concentric piecewise cylindrical vector beam can be used to construct controllable optical tweezers. (c) 2006 Elsevier GmbH. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

共光路外差干涉仪具有很高的分辨率.但因为安装、调试误差会产生非线性误差.影响系统的测量精度。着重分析了在共光路外差干涉仪中由激光光源的椭圆偏振化和沃拉斯顿棱镜的安装方位角误差同时存在的情况下,引起的频率混叠综合误差的大小及变化规律。结果发现其造成的非线性误差可达2.2nm,同时还发现两者造成的误差在某些情况下存在一定程度的相互抵消作用。讨论了提高测量系统精度的有效措施,对正确设计和调试激光外差测试系统、提高测量系统精度具有重要意义。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Only the first- order Doppler frequency shift is considered in current laser dual- frequency interferometers; however; the second- order Doppler frequency shift should be considered when the measurement corner cube ( MCC) moves at high velocity or variable velocity because it can cause considerable error. The influence of the second- order Doppler frequency shift on interferometer error is studied in this paper, and a model of the second- order Doppler error is put forward. Moreover, the model has been simulated with both high velocity and variable velocity motion. The simulated results show that the second- order Doppler error is proportional to the velocity of the MCC when it moves with uniform motion and the measured displacement is certain. When the MCC moves with variable motion, the second- order Doppler error concerns not only velocity but also acceleration. When muzzle velocity is zero the second- order Doppler error caused by an acceleration of 0.6g can be up to 2.5 nm in 0.4 s, which is not negligible in nanometric measurement. Moreover, when the muzzle velocity is nonzero, the accelerated motion may result in a greater error and decelerated motion may result in a smaller error.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

采用矢量法设计了三硼酸锂晶体上1064 nm、532 nm和355 nm三倍频增透膜,结果表明1064 nm、532 nm和355 nm波长的剩余反射率分别为0.0017%、0.0002%和0.0013%。根据误差分析,薄膜制备时沉积速率精度控制在+5.5%时,1064 nm、532 nm和355 nm波长的剩余反射率分别增加至0.20%、0.84%和1.89%。当材料折射率的变化控制在+3%时,1064 nm处的剩余反射率增大为0.20%,532 nm和355 nm处分别达0.88%和0.24%。与薄膜

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Neurotrophin-4 (NT-4) can promote neuronal growth, development, differentiation, maturation, and survival. NT-4 can also improve recovery and regeneration of injured neurons, but cannot pass through the blood-brain barrier, which limits its ac

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The alternate combinational approach of genetic algorithm and neural network (AGANN) has been presented to correct the systematic error of the density functional theory (DFT) calculation. It treats the DFT as a black box and models the error through external statistical information. As a demonstration, the AGANN method has been applied in the correction of the lattice energies from the DFT calculation for 72 metal halides and hydrides. Through the AGANN correction, the mean absolute value of the relative errors of the calculated lattice energies to the experimental values decreases from 4.93% to 1.20% in the testing set. For comparison, the neural network approach reduces the mean value to 2.56%. And for the common combinational approach of genetic algorithm and neural network, the value drops to 2.15%. The multiple linear regression method almost has no correction effect here.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We suggest a different practical scheme for the direct detection of pure spin current by using the two-color Faraday rotation of optical quantum interference process (QUIP) in a semiconductor system. We demonstrate theoretically that the Faraday rotation of QUIP depends sensitively on the spin orientation and wave vector of the carriers, and can be tuned by the relative phase and the polarization direction of the omega and 2 omega laser beams. By adjusting these parameters, the magnitude and direction of the spin current can be detected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new method to measure reciprocal four-port structures, using a 16-term error model, is presented. The measurement is based on 5 two-port calibration standards connected to two of the ports, while the network analyzer is connected to the two remaining ports. Least-squares-fit data reduction techniques are used to lower error sensitivity. The effect of connectors is deembedded using closed-form equations. (C) 2007 Wiley Periodicals, Inc.