29 resultados para Automatic adjustment
Resumo:
This paper presents an LC VCO with auto-amplitude control (AAC), in which pMOS FETs are used,and the varactors are directly connected to ground to widen the linear range of Kvco. The AAC circuitry adds little noise to the VCO but provides it with robust performance over a wide temperature and carrier frequency range.The VCO is fabricated in a chartered 50GHz 0.35μm SiGe BiCMOS process. The measurements show that it has - 127. 27dBc/Hz phase noise at 1MHz offset and a linear gain of 32.4MHz/V between 990MHz and 1.14GHz.The whole circuit draws 6. 6mA current from 5V supply.
Resumo:
This paper presents a new image segmentation method that applies an edge-based level set method in a relay fashion. The proposed method segments an image in a series of nested subregions that are automatically created by shrinking the stabilized curves in their previous subregions. The final result is obtained by combining all boundaries detected in these subregions. The proposed method has the following three advantages: 1) It can be automatically executed without human-computer interactions; 2) it applies the edge-based level set method with relay fashion to detect all boundaries; and 3) it automatically obtains a full segmentation without specifying the number of relays in advance. The comparison experiments illustrate that the proposed method performs better than the representative level set methods, and it can obtain similar or better results compared with other popular segmentation algorithms.
Resumo:
A facile, mild and rapid solid phase synthetic route free of column chromatographic purification to the synthesis of soluble monodisperse long-chain oligo(1,4-phenyleneethynylene)s is presented.
Efficient synthesis of high-quality MCM-48 silicas through mixed surfactants and pH adjustment route
Resumo:
机器人化是提高工程机械施工控制自动化的关键问题·通过将泵车布料机构的浇筑区域离散为浇筑点集 ,对两浇筑点内轨迹利用冗余度机器人学的最小关节范数法的轨迹规划 ,并将两相临浇筑段自动连接和自动协调 ,从而实现了混凝土泵车布料机构浇筑过程自动轨迹规划·
Resumo:
A data manipulation method has been developed for automatic peak recognition and result evaluation in the analysis of organic chlorinated hydrocarbons with dual-column gas chromatography. Based on the retention times of two internal standards, pentachlorotoluene and decachlorobiphenyl, the retention times of chlorinated hydrocarbons can be calibrated automatically and accurately. It is very convenient to identify the peaks by comparing the retention times of samples with the calibrated retention times calculated from the relative retention indices of standards. Meanwhile, with a suggested two-step evaluation method the evaluation coefficients and the suitable quantitative results of each component can be automatically achieved for practical samples in an analytical system using two columns with different polarities and two internal standards. (C) 2002 Elsevier Science B.V. All rights reserved.