30 resultados para Analyst


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new type of tyrosinase biosensor was developed for the detection of phenolic compounds, based on the immobilization of tyrosinase in a sol-gel-derived composite matrix that is composed of titanium oxide sol and a grafting copolymer of poly(vinyl alcohol) with 4-vinylpyridine. Tyrosinase entrapped in the composite matrix can retain its activity to a large extent owing to the good biocompatibility of the matrix. The parameters of the fabrication process and the variables of the experimental conditions for the enzyme electrode were optimized. The resulting sensor exhibited a fast response (20 s), high sensitivity (145.5 muA mmol(-1) 1) and good storage stability. A detection limit of 0.5 muM catechol was obtained at a signal-to-noise ratio of 3.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The electrochemiluminescence (ECL) of tris(2,2'-bipyridine)ruthenium(ii) [Ru(bpy)(3)(2+)] immobilized in poly(p-styrenesulfonate) (PSS)-silica-Triton X-100 composite films was investigated. The cooperative action of PSS, sol-gel and Triton X-100 attached Ru(bpy)(3)(2+) to the electrode strongly, and the presence of Triton X-100 prevented drying fractures of the sol-gel films during gelation and even on repeated wet-dry cycles. The modified electrode was used for the ECL detection of oxalate, tripropylamine (TPA) and NADH in a flow injection analysis (FIA) system with a newly designed flow cell. The detection scheme exhibited good stability, short response time and high sensitivity. Detection limits were 0.1, 0.1 and 0.5 mu mol L-1 for oxalate, TPA and NADH, respectively, and the linear concentration range extended from 0.001 to 1 mmol L-1 for the three analytes. Applications of the flow cell in ECL and electrochemical detection, as well as the immobilization of reagents based on the cooperative action, are suggested.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper, we present a novel strategy for improving the sensitivity of surface plasmon resonance immunosensing using a streptavidin-biotinylated protein complex. This amplification strategy is based on the construction of a molecular complex between streptavidin and biotin labeled protein. The complex can be formed in a cross-linking network of molecules so that the amplification of the response signal will be realized due to the big molecular size of the complex. The results show that the amplification strategy causes a dramatic improvement of the detection sensitivity. hIgG protein could be detected in the range of 0.005-10 mug ml(-1).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ethylenediaminetetraacetate (EDTA) was chosen for the investigation of the effect of metal ions on Ru(bpy)(3)(2+) electrochemiluminescence (ECL). Metal ions that are preferentially bound to the oxygen atoms (MIO) have no effect on the intensity of ECL except for Al3+ and Y3+, whereas metal ions that are preferentially bound to the nitrogen atoms (MIN) preclude the oxidation of EDTA and decrease the ECL intensity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A tyrosinase-based amperometric biosensor using a self-gelatinizable graft copolymer of poly(vinyl alcohol) with 4-vinylpyridine (PVA-g-PVP) as an immobilization matrix was constructed. The 4-vinylpyridine component of PVA-g-PVP enhances the adherence to a glassy carbon electrode surface. The content of 4-vinylpyridine in this immobilization matrix plays a key role in retaining the activity of tyrosinase. A simple, milder method was adopted by simply syringing the copolymer-tyrosinase aqueous solution on to the electrode surface and allowing water to evaporate at 4 degrees C in a refrigerator. Several parameters, including copolymer composition; pH, applied potential and enzyme membrane composition, ware optimized. The enzyme membrane composition can be varied to obtain higher sensitivity or a wider linear detection range. The biosensor was used for the determination of phenol, p-cresol and catechol. The biosensor exhibited excellent reproducibility, stability and sensitive response and can be used in flow injection analysis. The biosensor showed an extended linear range in hydrophilic organic solvents and it can be used in monitoring organic reaction processes. The analytical performance demonstrated this immobilization matrix is suitable for the immobilization of tyrosinase.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Capillary electrophoresis (CE) with end-column electrochemical detection (EC) of sulfadiazine (SDZ) and sulfamethoxazole (SMZ) is described. Under the optimum conditions, SDZ and SMZ were separated satisfactorily, and a highly sensitive and stable response was obtained at a potential of 1.1 V versus Ag/AgCl. Optimized end-column detection provides detection limits as low as 0.1 mu M for both compounds, which corresponds to 0.024 and 0.021 fmol with peak efficiencies of 394000 and 335000 theoretical plates for SDZ arid SMZ, respectively. The calibration graph was linear over three orders of magnitude. The relative standard deviations (n = 12) of peak currents and migration times were 2.3 and 2.7%, and 0.8 and 1.3%, respectively, for the two compounds. The proposed method was applied to the analysis of tablets and human urine samples with satisfactory results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A novel poly(vinyl alcohol) grafting 4-vinylpyridine self-gelatinizable copolymer was adapted to immobilize glucose oxidase. The reduction of hydrogen peroxide (H2O2) was detected at a Prussian Blue (PB) modified graphite electrode. A stable and sensitive glucose amperometric biosensor is described. The copolymer is a good biocompatible polymer in which the glucose oxidase retains high activity. Moreover, the copolymer can adhere firmly to the inorganic PB membrane. The sensor showed an apparent Michaelis-Menten constant of 18 +/- 0.2 mM and a maximum current density of 1.14 mu A cm(-2) mM(-1). The linear range is from 5 mu M to 4.5 mM glucose and the detection limit is 0.5. mu M glucose. The catalytic efficiency of PB for the reduction of H2O2 is higher than that for the oxidation of H2O2. Glucose concentrations in serum samples from healthy persons and diabetic patients were determined using the sensor. The results compared well with those provided by the hospital using a spectroscopy method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The determination of benzoic acid, thiourea and 2-mercaptoethanol in three pure organic solvents, viz., chloroform, chlorobenzene and 1,2-dichlorobenzene, by using an amperometric cryohydrogel tyrosinase biosensor is described. Measurements were carried out with phenol as the enzyme substrate. Kinetic parameters (K-i and I-50) were determined in the three solvents for various inhibitors. The sensor showed the most sensitive measurements to these inhibitors in pure chloroform. The solvent-induced deviation of the biosensor to thiourea was evaluated by means of Hill coefficients. The smallest deviation as observed in 1,2-dichlorobenzene, owing to the high hydrophobicity of this solvent. The nature of the inhibition process and its reversibility mere also examined.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An acetylcholinesterase (AChE) activity detection system was fabricated based on the electrocatalysis of cobalt(II) tetraphenylporphyrin of the electrooxidation of thiocholine chloride, which is the product of the hydrolysis of acetylthiocholine chloride by AChE. A simple modified method was used to form the base electrode. AChE was cross-linked on the base electrode by glutaraldehyde. The optimum working conditions are discussed and the characteristics of the detection system are evaluated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A reversed-phase high-performance liquid chromatographic method with amperometric detection is described for the separation and quantification of uric acid, guanine, hypoxanthine and xanthine. The isocratic separation of a standard mixture of the compounds was achieved in 5 min on a Spherisorb 5 C-18 reversed-phase column, with a mobile phase of NaH2PO4 (300 mmol dm(-3) pH 3.0)-methanol-acetonitrile-tetrahydrofuran (97.8 + 0.5 + 1.5 + 0.2). Uric acid, guanine, hypoxanthine and xanthine were completely separated, with detection limits in the range 2-20 pmol per injection. The effect of pH and the composition of the mobile phase on the separation are described. The hydrodynamic voltammograms of these compounds were recorded at a glassy carbon electrode. The linear range of the calibration graph for each compound was: uric acid; 1-5000 mu mol dm(-3); guanine, 0.5-2000 mu mol dm(-3); hypoxanthine, 0.1-500 mu mol dm(-3) and xanthine, 0.5-5000 mu mol dm(-3). The within- and between-day precision was good. The uric acid and hypoxanthine content in human plasma was measured using the proposed method. Good recoveries of uric acid (97.9-103%), hypoxanthine (98.0-99.2%), guanine (96.0-98.3%) and xanthine (96.0-102%) were obtained from human plasma. The results of electrochemical detection were in good agreement with those of UV detection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

G chemically modified electrode (CME) was prepared by electrochemical copolymerization of pyrrole and Methylene Blue. The resulting CME exhibits effective electrocatalytic activity towards the oxidation of reduced nicotinamide coenzymes (NADH and NADPH),

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two M(n+)-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol systems for the simultaneous determination of the valence states of Cr and Fe using factor analysis were studied. (1) At pH 4.0, Cr(III) and Cr(VI) react with the reagent to form stable complexes and a slight difference in the wavelengths of maximum absorption (lambda(max.)) between the two complexes is observed when the sodium lauryl sulfate, which also acts as a solubilizing and sensitizing agent, is added, viz., 590 nm for Cr(III) and 593 nm for Cr(VI) complexes. (2) In the presence of ethanol, both Fe(II) and Fe(III) form 1:2 complexes with the reagent at pH 2.5-3.5 and the lambda(max.) of the Fe(II) and Fe(III) complexes is at 557 and 592 nm, respectively. In the target transformation factor analysis, the K coefficients calculated from the standard mixtures by classical least-squares analysis and a non-zero intercept added to each wavelength are used as the target vector instead of the pure component standards; this can decrease the analysis errors introduced by the interaction between the two species and by deviations from Beer's law.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

基于GIS和DEM的流域地表水文模拟可为分布式水文模型提供下垫面数据输入.本文采用内嵌于ArcGIS的地表水文分析工具Arc Hydro Tools,结合ArcGIS及其扩展模块Spatial Analyst,以贵州省内乌江流域为例,进行了流域水文模拟分析.运用Arc Hydro Tools进行地表水文模拟分析,主要包括以下4个流程:DEM的预处理、水流方向的确定、汇流栅格图的生成、自动提取河网和子流域边界.试验结果表明,提取河网的空间分布接近实际分布情况,数字流域界线的确定与水文部门基本相符.