280 resultados para Mass shift


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three known flavonoids, quercetin, quercitrin (quercetin-3-0-rhamnoside) and rutin (quercetin-3-0-rutinoside), have been identified for the first time in the leaves of Acanthopanax senticosus Harms by using electrospray tandem mass spectrometry techniques (ESI-MSn). The flavonoid hyperin (quercetin-3-0-beta-galactoside), already known to be present, was also investigated. The diagnostic fragment ions of the aglycone quercetin were obtained in the ESI-MSn experiments, and a fragmentation mechanism proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fragmentation pathways of aconitine-type alkaloids were investigated by electrospray ionization/ion trap multistage tandem mass spectrometry. Low-energy collision-induced dissociation of protonated aconitines follows a dominant first step, the elimination of the C-8-substituent as acetic acid or fatty acid in MS2 spectra. Successive losses of 1-4 CH3OH molecules, 1-3 H2O, CO, benzoic acid, and CH3 or C2H5 (N-substituents) are all fragmentation pathways observed in MS3 and MS4 spectra. By applying knowledge of these fragmentation pathways to the aconitines in the ethanolic extract of aconite roots, all the known aconitines were detected and also 23 unknown aconitine-type alkaloids, in which the lipo-alkaloids containing residues of 15C, 17C and 19C saturated or unsaturated fatty acids were characterized. These odd-carbon-number fatty acid substituents have not been reported previously.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Matrix effects in now injection (FI) inductively coupled plasma mass spectrometry has been studied,and the results have been compared with those of continuous nebulization. The matrix element As and nu with higher ionization potential ( > 9eV) have enhancement effect on the analyte signal,and the heavier the analyte mass, the smaller the enhancement effects by Fl. The matrix elements Cu, In, Li, Na and Pb with lower ionization potential have suppression effect on the analyte signal. The heavier the matrix element mass, the more severe the suppression effects. The heavier the analyte mass, the smaller the suppression effects. The higher ionization potential of analyte, the more severe the suppression effects. Compared with continuous nebulization, the degree of suppression effect is smaller and the degree of the enhancement effect is larger by Fl.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mica, as a bridge of the study for combining between quartz crystal microbalance (QCM) and atomic force microscope (AFM), was successfully modified onto the piezoelectric quartz crystal (PQC). This mica-modified piezoelectric quartz crystal (mica-PQC) can be stably oscillated with a shift frequency of +/-1 Hz per half an hour in air. Using this mica-PQC, the processes of DNA adsorbed onto the mica surface were studied in liquid phase. The results show that a bivalent cation, such as Mn2+, can be used as an ionic bridge to immobilize DNA on mica surface. The image of DNA on the mica surface was also obtained by AFM. Mica-PQC gives the possibility of a combination between QCM and AFM in situ.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Procedures that allow the realization of resonance electron capture (REC) mode on a commercial triple-quadrupole mass spectrometer, after some simple modifications, are described, REC mass spectrometry (MS) and tandem mass spectrometry (MS/MS) experiments were performed and spectra for some compounds were recorded. In particular, the charge-remote fragmentation (CRF) spectra of [M - H](-) ions of docosanoic and docosenoic acids under low-energy collisionally activated dissociation (CAD) conditions were obtained, and showed that there were no significant differences for [M - H](-) ions produced at different resonances (i,e. for [M - H](-) ions with different structures). This observation was explained on the basis of results obtained from deuterium-labeled fatty acids, which showed that different CRF ions (but with the same m/z value in the absence of labels) could be produced by different mechanisms, and all of them were obviously realized under CAD conditions that made spectra practically indistinguishable. The other example, which compared the REC-MS/MS spectrum of [M - H](-) ions and EI-MS/MS spectrum of M+. ions of daidzein, demonstrated the potential of the REC-MS/MS technique for more complex structure elucidation. Copyright (C) 2000 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The influence of swelling and stripping acidity on the mass transfer coefficient based on water phase and the inner diameters of membranes were studied with P507-HCl-Sm as working system in the two different kinds of hollow fiber membranes. Effects of extractant concentration, H+ concentration in aqueous phase and Sm3+ concentration on extraction rate were discussed and the corresponding reaction series were obtained. According to the investigations on the interfacial kinetics, the reaction kinetics equation and reaction rate constant were obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Matrix effects arising from ethanol, propanol, glycerol, acetic acid, ethylenediamine and triethanolamine in inductively coupled plasma mass spectrometry have been studied. Addition of ethanol, propanol, glycerol, acetic acid, ethylenediamine and triethanolamine into solution has an enhancement effect on the signal intensity of analyte with ionization potential between 9 and 11 eV. The ethylenediamine and triethanolamine have higher enhancement effect on the signal intensity of Hg than that of ethanol, propanol, glycerol and acetic acid. Addition of ethylenediamine and triethanolamine into solution has a suppression effect on the signal intensity of Ph and Sr. The mechanism of the enhancement or suppression was investigated. The signal enhancement of Hg in the presence of ethylenediamine and triethanolamine is not caused by improved degree of ionization of Hg and nebulization efficiency. The suppression effects of Ph and Sr in the presence of ethylenediamine and triethanolamine are due to decrease of atomization efficiency of these elements. A method for the determination of Hg in the biological standard samples Ly ICP-MS was developed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monodispersed polyaniline oligomers was studied by matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF-MS), It is found that MALDI-TOF-MS is not only a direct, accurate and rapid tool for the analysis of monodispersed polyaniline oligomers, but also a useful technique for the design of synthetic route.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Single-colour and two-colour multiphoton resonant ionization spectra of uranium atom were studied extensively with a Nd: YAG laser-pumped dye laser atomic beam apparatus time-of-flight mass spectrometer in our laboratory. The energy locations of high-lying odd-parity levels in the region 33 003-34 264 cm(-1),mearured by a two-colour three-step ionization technique, were reported here. The angular momentum quantum number J was uniquely assigned for these levels by using angular momentum selection rules.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Inductively coupled plasma mass spectrometry (ICP-MS),a highly sensitive inorgnic analytic technique,fits to determine ultra-nace rare-earth elements in human plasma. Under the optimized conditions detection limits for 15 rare-earth elements are in the range of 0.7 (for Eu)-5.4 (for Gd) ng.L-1. Indium as an internal standard element is used to compensate for matrix suppression effect and sensitivity drift. Three kinds of preparation methods, diluted with 1% HNO3, digested with HNO3-H2O2 and with HNO3-HClO4, are checked and compared,and the former is the simplest way to be measured. The samples diluted with 1% HNO3, stored in 4 degrees C, are very steady for 16 days. With the method, 11 healthy plasma samples in Changchun area of China are analysed.