353 resultados para Laser induced poling
Resumo:
The time of flight mass spectrometric technique was used to determine the initial mean kinetic energy of small fragment ions C-n(+) (n <= 11) produced from C-60 excited by 532 nm nanosecond laser pulses. The measured kinetic energy shows little variation with the fragment mass and the laser fluence in a broad range. Based on the assumption that C-30(+) is produced predominantly by a single electron emission followed by successive C-2 evaporation from hot C-60 in the nanosecond laser field, the formation of small fragments is interpreted as the complete breakup of the unstable C-30(+) cage structure. The interpretation is consistent with the previously observed results.
Resumo:
本文利用Nd:YAG纳秒激光器与配有CCD探测器的四通道光纤光谱仪建立了一套可用于植物样品激光诱导击穿光谱(LIBS)测量的实验装置。基于该实验装置,论文着重开展了激光参数、探测角度、延迟时间等对LIBS 光谱影响以及植物样品LIBS光谱定性、定量分析两方面的实验研究工作。通过实验研究发现:1、在某一激光能量点处,LIBS有最大的相对光谱强度;2、红外(IR)激光击穿阈值要高于紫外(UV)激光,并且IR激光产生的LIBS光谱中连续谱强度也强于UV激光;3、粒子谱线信噪比随时间演化的方式与其产生机制有密切关系;4、光纤与样品表面法线方向夹角越小越容易获得信噪比大的光谱。对所获得的植物样品LIBS光谱分析得到以下结论:1、在230~1080nm范围内,从苹果表皮样品的LIBS中观测到了380余条谱线,鉴别分析出二十多种元素和分子;2、对经过真空冻干处理的三种水果和两种蔬菜样品中的K、Ca、Fe、Na、Mg、Al六种微量元素相对含量分别进行了比较。实验结果表明LIBS技术是分析比较植物样品中微量元素含量的一种有效方法
Resumo:
We have developed a new experimental system based on a microfluidic chip to determine severe acute respiratory syndrome coronavirus (SARS-Cov). The system includes a laser-induced fluorescence microfluidic chip analyzer, a glass microchip for both polymerase chain reaction (PCR) and capillary electrophoresis, a chip thermal cycler based on dual Peltier thermoelectric elements, a reverse transcription-polymerase chain reaction (RT-PCR) SARS diagnostic kit, and a DNA electrophoretic sizing kit. The system allows efficient cDNA amplification of SARS-CoV followed by electrophoretic sizing and detection on the same chip. To enhance the reliability of RT-PCR on SARS-CoV detection, duplex PCR was developed on the microchip. The assay was carried out on a home-made microfluidic chip system. The positive and the negative control were cDNA fragments of SARS-CoV and parainfluenza virus, respectively. The test results showed that 17 positive samples were obtained among 18 samples of nasopharyngeal swabs from clinically diagnosed SARS patients. However, 12 positive results from the same 18 samples were obtained by the conventional RT-PCR with agarose gel electrophoresis detection. The SARS virus species can be analyzed with high positive rate and rapidity on the microfluidic chip system.
Resumo:
Bond distances, vibrational frequencies, electron affinities, ionization potentials, dissociation energies, and dipole moments of the title molecules in neutral, positively, and negatively charged ions were studied using density functional method. Ground electronic state was assigned for each molecule. The bonding patterns were analyzed and compared with both the available data and across the series. It was found that, besides ionic component, covalent bonds are formed between the metal s, d orbitals, and the p orbital of S, Se, and Te. For neutral and cationic molecules, the covalent character increases from ScX to CrX and from FeX to CuX with an exception of decrease at MnX and ZnX, while for anionic molecules, the trend is not obvious. For both neutral and charged molecules, the sulfides have the shortest bond distance and largest vibrational frequency, while tellurides have the largest bond distance and smallest vibrational frequency. For neutral and anionic molecules, the dissociation energy of sulfides is the largest, that of tellurides is the smallest, while this only remains true for cationic molecules from ScX+ to FeX+.
Resumo:
Bond distances, vibrational frequencies, dipole moments, dissociation energies, electron affinities, and ionization potentials of NIX (XM = Y-Cd, X = F, Cl, Br, I) molecules in neutral, positively, and negatively charged ions were studied by density functional method, B3LYP. The bonding patterns were analyzed and compared with both the available data and across the series. It was found that besides ionic component, covalent bonds are formed between the 4d transition metal s, d orbitals, and the p orbital of halogen. For both neutral and charged molecules, the fluorides have the shortest bond distance, iodides the longest. Although the opposite situation is observed for vibrational frequency, that is, fluorides have the largest value, iodides the smallest. For neutral and anionic species, the dissociation energy tends to decrease with the increasing atomic number from Y to Cd, suggesting the decreasing or weakening of the bond strength. For cationic species, the trend is observed from Y to Ag.
CE coupling with end-column electrochemiluminescence detection for chiral separation of disopyramide
Resumo:
CE with electrochemiluminescence, (ECL) detection technique was successfully applied for the chiral separation of a kind of class IA antiarrhythmic racemic drug. To the best of our knowledge, this is the first report of ECL detection used in chiral CE. To get better detection sensitivity and good enantioresolution at the same time, the conditions of capillary inlet and outlet buffer were systematically optimized. Unlike the traditional chiral separation method, the buffers we used in the capillary inlet and outlet differed from each other in terms of buffer pH, ionic strength, type of BGE as well as buffer composition. Under the optimum conditions, baseline enantioseparation and highly sensitive detection of the enantiomers were achieved. Wide linear relationship of each enantiomer was achieved in the range of 5 x 10(-7) to 2 x 10(-5) mol/L with relative coefficients of 0.996 and 0.997, respectively. The detection limits were estimated to be 8 x 10(-8) and 1.0 X 10(-7) mol/L (S/N = 3) for the enantiomers, respectively. In addition, a successful application of this new method to the chiral separation of the racemic drug in spiked plasma samples confirmed the validity and applicability of the chiral CE-ECL method.
Resumo:
Graft copolymerization in the molten state is of fundamental importance as a probe of chemical modification and reactive compatibilization. However, few grafting kinetics studies on reactive extrusion were carried out for the difficulties as expected. In this work, the macromolecular peroxide-induced grafting of acrylic acid and methyl methacrylate onto linear low density polyethylene by reactive extrusion was chosen as the model system for the kinetics study; the samples were taken out from the barrel at five ports along screw axis and analyzed by FTIR, H-1 NMR, and ESR. For the first time, the time-evolution of reaction rate, the reaction order, and the activation energy of graft copolymerization and homopolymerization in the twin screw extruder were directly obtained. On the basis of these results, the general reaction mechanism was tentatively proposed. It was demonstrated that an amount of chain propagation free radicals could keep alive for several minutes even the peroxides completely decomposed and the addition of monomer to polymeric radicals was the rate-controlled step for the graft copolymerization.
Resumo:
The biogenic amines, putrescine, cadaverine, spermidine and spermine were separated and quantified by capillary electrophoresis with pulsed amperometric detection. Detection potential of the pulsed amperometric detection was optimized as 0.6 V Optimal separation of the biogenic amines was achieved using a separation buffer of 30 mM citrate at pH 3.5, while keeping the buffer in the detection cell as 20 mM NaOH. Using these conditions, the four biogenic amines were baseline separated. Extrapolated limits of detection for putrescine, cadaverime, spermidine and spermine were 400, 200, 100 and 400 nM for the standard mixture (polyamines dissolved in running buffer), respectively. These are lower than ultraviolet detection and comparable or even lower than laser-induced fluorescence detection results as reported in the literature. The number of theoretical plates was maintained at the 105 level, which is absolutely higher than any reported method. When applying capillary electrophoresis-pulsed amperometric detection to milk analysis, only spermidine was found in amounts varying between 0.1 and 0.5 mg/kg.
Resumo:
We propose a laser induced sensitized fluorescence spectrometry for measuring the spontaneous emission branching ratios o?the transitions from the ten levels 5f36d7s7p-7M7, 5f36d7s7p-7L6, 5f37s27p-5K6, 5f26d27s2 - 5L7, 5f46d7s - 7L6, (17,070cm-1)-5L6, 5f26d27s2-5K6, 6d7s7p-7L5, 5f36d7s7p-7K5 and 5f26d27s2-5I5 to the ground state of atomic uranium (UI) for the first time. Their relative oscillator strengths have been measured by means of hollow cathode discharge (HCD) emission spectrometry. The radiative...
Resumo:
激光诱导击穿光谱技术(LIBS)具有无需样品制备,原位快速分析,可进行实时控制的特点使其在钢铁冶炼控制中具有巨大的实际应用价值。本文以波长为1 064 nm的Nd∶YAG调Q固体激光器为激发光源,CCD为探测器,高合金钢GBW01605—01609系列为样品,在建立的LIBS实验装置上研究激光与合金钢之间的相互作用。系统地研究了观测距离、激光能量对高合金钢样品中激光诱导击穿谱特性的影响,并分析了LIBS信号的时间分辨特性,确定了将LIBS用于合金钢微量元素定量分析时的最佳实验条件。
Resumo:
利用激光诱导击穿光谱定量分析了铝合金中多种元素的成分。采用Nd∶YAG脉冲激光器,在空气环境下烧蚀铝合金固体样品获得等离子体。利用多通道光栅光谱仪和CCD检测器对200~980nm波长范围的光谱进行同时检测。研究了检测时延、激光脉冲能量、元素深度分布对光谱强度的影响,考虑这些因素之后对实验参数进行了优化。在优化的实验参数下对国家标准铝合金样品中的八种元素Si,Fe,Cu,Mn,Mg,Zn,Sn及Ni进行了定标,并利用定标曲线对一种铝合金样品进行了定量分析。实验结果表明,测量结果的相对标准偏差(RSD)最大为5.89%,相对误差在-20.99%~15%范围内,说明对铝合金样品成分进行定量分析,激光诱导击穿光谱是一种有效的光谱分析工具,但是分析结果的准确度仍需要提高。
Resumo:
This payer presents a concrete theoretical treatment which can be used for transforming the laser-induced fluorescence (LIF) intensity into the population and alignment parameters of a symmetric top molecule, The molecular population and alignment are described by molecular state multipoles. The results are presented in a general excitation-detection geometry and then specialized in some special geometries. The problem how to extract the initial molecular state multipoles from the rotationally resolved LIF intensity is discussed in detail. (C) 1999 Elsevier Science B.V. All rights reserved.
Resumo:
General expressions used for transforming raw laser-induced fluorescence (LIF) intensity into the population and alignment parameters of a symmetric top molecule are derived by employing the density matrix approach. The molecular population and alignment are described by molecular state multipoles. The results are presented for a general excitation-detection geometry and then applied to some special geometries. In general cases, the LIF intensity is a complex function of the initial molecular state multipoles, the dynamic factors and the excitation-detection geometrical factors. It contains a population and 14 alignment multipoles. How to extract all initial state multipoles from the rotationally unresolved emission LIF intensity is discussed in detail.
Resumo:
Expressions used for extracting the population and alignment parameters of a symmetric top molecule from (n + 1) laser-induced fluorescence (LIF) are derived by employing the tensor density matrix method. The molecular population and alignment are described by molecular state multipoles. The LIF intensity is a complex function of the initial molecular state multipoles, the dynamic factors, and the excitation-detection geometrical factors. The problem of how to extract the initial molecular state multipoles from (2 + 1) LIF, as an example, is discussed in detail. (C) 2000 American Institute of Physics. [S0021-9606(00)30744-9].
Resumo:
A microchip electrophoresis method coupled with laser-induced fluorescence (LIF) detection was established for simultaneous determination of two kinds of intracellular signaling molecules (reactive oxygen species, ROS, and reduced glutathione, GSH) related to apoptosis and oxidative stress. As the probe dihydrorhodamine-123 (DHR123) can be converted intracellularly by ROS to the fluorescent rhodamine-123 (Rh123), and the probe naphthalene-2,3-dicarboxaldehyde (NDA) can react quickly with GSH to produce a fluorescent adduct, rapid determination of Rh-123 and GSH was achieved on a glass microchip within 27 s using a 20 mm borate buffer (pH 9.2). The established method was tested to measure the intracellular ROS and GSH levels in acute promyelocytic leukemia (APL)-derived NB4 cells. An elevation of intracellular ROS and depletion of GSH were observed in apoptotic N134 cells induced by arsenic trioxide (AS(2)O(3)) at low concentration (1-2 mu m). Buthionine sulfoximine (BSO), in combination with AS(2)O(3) enhanced the decrease of reduced GSH to a great extent. The combined treatment of AS(2)O(3) and hydrogen peroxide (H2O2) led to an inverse relationship between the concentrations of ROS and GSH obtained, showing the proposed method can readily evaluate the generation of ROS, which occurs simultaneously with the consumption of the inherent antioxidant.