179 resultados para repertory grid technique


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simultaneous electrochemiluminescence (ECL) and electrochemical (EC) detection scheme for NACE was presented for fast analysis of tertiary amines. Both ECL and EC signals were generated at the same Pt electrode. Triethylamine (TEA), tripropylamine (TPrA), chlorpromazine, promethazine, and dioxopromethazine (DPZ) were selected to validate NACE-ECL/EC dual detection strategy. The linear ranges for TEA and TPrA were 0.01-500 and 0.01-10 mu M with the detection limits of 8.0 and 5.0 nM (S/N=3), respectively. The RSDs (n = 6) of the migration time and the ECL intensity for 1 mu M TEA and 0.5 mu M TPrA were 0.1 and 2.8%, and 0.2 and 1.8% with theoretical plate numbers of 180 000 and 700 000 per meter, respectively. These two analytes could be separated within 92 s and the Pt electrode did not need reactivation during the experiments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work herein reports the approach for the simultaneous determination of heavy metal ions including cadmium (Cd(II)), lead (Pb(II)), and chromium (Cr(VI)) using a bismuth film electrode (BFE) by anodic stripping voltammertry (ASV). The BFE used was plated in situ. Due to the reduction of Cr(VI) with H2O2 in the acid medium, on one hand, the Cr(III) was produced and Cr(VI) was indirectly detected by monitoring the content of Cr(III) using square-wave ASV. On the other hand, Pb(II) was also released from the complex between Pb(II) and Cr(VI). Furthermore, the coexistence of the Cd(II) was also simultaneously detected with Pb(II) and Cr(VI) in this system as a result of the formation of an alloy with Bi. The detection limits of this method were 1.39 ppb for Cd(II), 2.47 ppb for Pb(II) and 5.27 ppb for Cr(VI) with a preconcentration time of 120 s under optimal conditions (S/N = 3), respectively. Furthermore, the sensitivity of this method can be improved by controlling the deposition time or by using a cation-exchange polymer (such as Nafion) modified electrode.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new approach for the synthesis of polyaniline nanofibers under pseudo-high dilute conditions in aqueous system has been developed. High yield nanoscale polyaniline fibers with 18-110 nm in diameter are readily prepared by a high aniline concentration 0.4 M oxidation polymerization using ammonium persulfate (APS) as an oxidant in the presence of hydrochloric acid (HCl), perchloric acid (HClO4), (1S)-(+)-10-camphorsulfonic acid (CSA), acidic phosphate PAEG120 (PA120) and sulfuric acid (H2SO4) as the dopants. The novel pathway always produces polyaniline nanofibers of tunable diameters, high conductivity (from 10(0) to 10(1) S/cm) and crystallinity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Investigation of a heterogeneous electron-transfer (ET) reaction at the water/1,2-dichloroethane interface employing a double-barrel micropipet technique is reported. The chosen system was the reaction between Fe(CN)(6)(3-) in the aqueous phase (W) and ferrocene in 1,2-dichloroethane (DCE). According to the generation and the collection currents as well as collection efficiency, the ET-ion-transfer (IT) coupling process at such an interface and competing reactions with the organic supporting electrolyte in the organic phase can be studied. In addition, this technique has been found to be an efficient method to distinguish and measure the charge-transfer coupling reaction between two ions (IT-IT) processes occurring simultaneously at a liquid/liquid interface. On this basis, the formal Gibbs energies of transfer of some ions across the W/DCE interface, such as NO3-, NO2-, Cl-, COO-, TBA(+), IPAs+, Cs+, Rb+, K+, Na+, and Li+, for which their direct transfers are usually difficult to obtain because of the IT-IT coupling processes, were quantitatively evaluated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new method for the fabrication of an integrated microelectrode for electrochemical detection (ECD) on an electrophoresis microchip is described. The pattern of the microelectrode was directly made on the surface of a microscope slide through an electroless deposition procedure. The surface of the slide was first selectively coated with a thin layer of sodium silicate through a micromolding in capillary technique provided by a poly(dimethylsiloxane) (PDMS) microchannel; this left a rough patterned area for the anchoring of catalytic particles. A metal layer was deposited on the pattern guided by these catalytic particles and was used as the working electrode. Factors influencing the fabrication procedure were discussed. The whole chip was built by reversibly sealing the slide to another PDMS layer with electrophoresis microchannels at room temperature. This approach eliminates the need of clean room facilities and expensive apparatus such as for vacuum deposition or sputtering and makes it possible to produce patterned electrodes suitable for ECD on microchip under ordinary chemistry laboratory conditions. Also once the micropattern is ready, it allows the researchers to rebuild the electrode in a short period of time when an electrode failure occurs. Copper and gold microelectrodes were fabricated by this technique. Glucose, dopamine, and catechol as model analytes were tested.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The compositions of the extracted complexes of La, Gd, Er and Y with sec-octyl-phenoxy acetic acid in heptane and the related apparent extraction equilibrium constants K-M were determined using two-phase titration technique. The stoichiometric compounds for La, Gd, Er and Y should be LaA(3) . 2.5HA, GdA(3) . 3HA, ErA(3) . 3.1HA and YA(3) . 4.3HA respectively. And their pK(M) are 3.43, 3.46, 3.08 and 2.58 respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

capillary electrophoresis (CE) is characterized. A 300 mum diameter Pt working electrode was used to directly couple with a 75 mum inner diameter separation capillary without an electric field decoupler. The hydrodynamic cyclic voltammogram (CV) of Ru(bpy)(3)(2+) showed that electrophoretic current did not affect the ECL reaction. The presence of high-voltage (HV) field only resulted in the shift of the ECL detection potential. The distance of capillary to electrode was an important parameter for optimizing detection performance as it determined the characteristics of mass transport toward the electrode and the actual concentration of Ru(bpy)(3)(2+) in the detection region. The optimum distance of capillary to electrode was decided by the inner diameter of the capillary, too. For a 75 mum capillary, the working electrode should be placed away from the capillary outlet at a distance within the range of 20-260 mum. The effects of pH value of ECL solution and molecular structure of analytes on peak height and theoretical plate numbers were discussed. Using the 75 mum capillary, under the optimum conditions, the method provided a linear range for tripropylamine (TPA) between 1 x 10(-10) and 1 X 10(-5) mol/L with correlation coefficient of 0.998. The detection limit (signal-to-noise ratio S/N = 3) was 5.0 x 10(-11) mol/L. The relative standard deviation in peak height for eight consecutive injections was 5.6%. By this new technique lidocaine spiked in a urine sample was determined. The method exhibited the linear range for lidocaine from 5.0 x 10(-8) to 1.0 X 10(-5) mol/L with correlation efficient of 0.998. The limit of detection (S/N = 3) was 2.0 x 10(-1) mol/L.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A kind of simple atomic force microscopy (AFM) relocated technique, which takes advantage of homemade sample locator system, is used for investigating repeatedly imaging of some specific species on the whole substrate (over 1 x 1 cm(2)) with resolution about 400 nm. As applications of this sample locator system, single extended DNA molecules and plasmid DNA network are shown in different AFM operational modes: tapping mode and contact mode with different tips after the substrates have been moved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new electrochemiluminescence (ECL) microoptoprobe with simple structure. small sampling volume and high efficiency was developed. It was constructed by fixing the transparent gold mini-grid on the end surface of the optical fiber, and by surrounding the fiber with the counter- and reference electrodes to form a self-contained three-electrode system. The use of mini-grid electrode increased the surface area and collection efficiency. which resulted in higher ECL signal and better sensitivity. The counter electrode together with one end of the fiber formed a mini-vessel, which eliminated the need of additional container and allowed to perform ECL detection in a very small volume (about 10 mul). The microoptoprobe obtained was characterized with the Ru(bpy)(3)(2-)-tripropylamine system and was applied for the determination of oxalate and chlorpromazine (CPZ). Detection limits (S/N = 3) were 5 x 10(-7) and 1 x 10(-6) mol l(-1) for oxalate and CPZ. respectively. The linear range for oxalate and CPZ extended from 1 x 10(-6) to 1 x 10(-3) mol l(-1), and from 5 x 10(-6) to 5 x 10(-4) mol l(-1). respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this article, the polydispersity of the ethylene sequence length (ESL) in ethylene/alpha-olefin copolymers was studied by atomic force microscopy (AFM) and the thermal-fractionation technique. The crystal morphology observation by AFM showed that morphology changed gradually with decreasing average ESL from complete lamellae over shorter and more curved lamellae to a granular-like morphology, and the mixed morphology was observed after stepwise crystallization from phase-separated melt. This result indicated that the ethylene sequence with different lengths crystallized into a crystalline phase with a different size and stability at the copolymer systems. The thermal-fractionation technique was used to characterize the polydispersity of ESL. Three of the following statistical terms were introduced to describe the distribution of ESL and the lamellar thickness: the arithmetic mean (L) over bar (n), the weight mean (L) over bar (w), and the broadness index I = (L) over bar (w)/(L) over bar (n). It was concluded that the polydispersity of ESL could be quantitatively characterized by the thermal-fractionation technique. The effects of temperature range, temperature-dependent specific heat capacity C-p of copolymer, and the molecular weight on the results of thermal fractionation were discussed,

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mixed monolayer films of octadecylamine (ODA) and oligo-DNA were prepared by Langmuir-Blodgett technique and the monolayer films were used as template to direct the formation of different CdS nanostructures. It was found that CdS nanowire was observed when the monolayer film prepared at low surface pressure was used as template, and aggregate of CdS spheres was obtained when the monolayer film deposited at high surface pressure was used as template.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this report, we describe an improved thermal fractionation technique used to characterize the polydispersity of crystalline ethylene sequence length (CESL) of ethylene/alpha -olefin copolymers. After stepwise isothermal crystallization, the crystalline ethylene sequences are sorted into groups by their lengths. The CESLs are estimated using melting points of known hydrocarbons. The content of each group is determined using the calibrated peak area. The statistical terms: the arithmetic mean (L) over bar (n), the weighted mean (L) over bar (w) and the broadness index I = (L) over bar (w)/(L) over bar (n) are used to describe the distribution of CESL. Results show that improved thermal fractionation technique can quantitatively characterize the polydispersity of CESL with a high degree of accuracy.