237 resultados para LP-Sasakian Manifold


Relevância:

10.00% 10.00%

Publicador:

Resumo:

为实现对现场设备的远程监测,采用内嵌RTOS(Nut/OS)和TCP/lP协议的嵌入式电源控制器。自行设计部分软、硬件,通过以太网编程实现系统的远程控制。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

阐述了位置灵敏探测器在核物理实验中的作用,同时详细叙述了低气压多丝室(LP-MWPC)的工作机理及时间、位置特性。描述了用于较高能量轻粒子的次级束实验的LP-MWPC的结构和测试结果,得到ΔX=ΔY=0.7mm的位置分辨。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study is aimed at observing the apoptosis and Bcl-2/Bax gene expression of mammalian cells following heavy-ion and X-ray irradiations. Exponentially growing human hepatoma SMMC-7721 cells cultured in vitro were irradiated with a C-12 ion beam of 50 MeV/u (corresponding to a LET value of 44.56 keV/mu m) from Heavy Ion Research Facility in Lanzhou (HIRFL) at doses varying from 0 to 3 Gy. The X-ray irradiation (8 MV) was performed in the therapy unit of the General Hospital of the Lanzhou Military Area. Survival fractions of irradiated cells at various doses were measured by means of MTT assay. Apoptotic cells after irradiation were analyzed with fluorescence microscope and flow cytometer (FCM). Immuno-histological assay were applied to detect the expression of Bcl-2/Bax genes in the irradiated cells. The survival fraction of SMMC-7721 cells decreased gradually (vs. control p<0.05) with increasing the dose of the carbon ion beam more obviously than X-ray irradiation, and the carbon ion irradiation efficiently induced cell apoptosis and significantly promoted the expression of Bax gene while Bcl-2 gene expression was restrained. High-LET heavy ion beam would induce cell apoptosis effectively than low-LET X-ray, and the apoptosis rate is correlated with the transcription of Bcl-2/Bax and the ratio of Bcl-2/Bax in human hepatoma SMMC-7721 cells after irradiation to heavy ion beam.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Here we study fermionic zero modes in gauge and gravity backgrounds taking a two-dimensional compact manifold T-2 as extra dimensions. The result is that there exist massless Dirac fermions which have normalizable zero modes under quite general assumptions about these backgrounds on the bulk. Several special cases of gauge background on the torus are discussed and some simple fermionic zero modes axe obtained.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Superconducting quarter-wave resonators, due to their compactness and their convenient shape for tuning and coupling, are very attractive for low-beta beam acceleration. In this paper, two types of cavities with different geometry have been numerically simulated: the first type with larger capacitive load in the beam line and the second type of lollipop-shape for 100 MHz, beta=0.06 beams; then the relative electromagnetic parameters and geometric sizes have been compared. It is found that the second type, whose structural design is optimized with the conical stem and shaping drift-tube, can support the better accelerating performance. At the end of the paper, some structural deformation effects on frequency shifts and appropriate solutions have been discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In order to realize high energy density physics and plasma physics research at HIRFL-CSR, a magnetic alloy (MA)-loaded cavity has been studied. According to the theoretical calculation and simulation for the MA-loaded cavity, we achieved a better result. The MA-loaded cavity had a higher mu Q f value, with a higher shunt impedance and a higher accelerating gradient. The accelerating gradient was about 95 kV/m at 1.8003 MHz, 130 kV/m at 0.9000 MHz. Compared with the ferrite-loaded cavities that are used at HIRFL-CSR, with about 10 kV/m accelerating gradient, the MA-loaded cavity obviously has an advantage. The results of the theoretical calculation and the simulation, which meet the design requirements are in good agreement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A high current RFQ (radio frequency quadrupole) is being studied at the Institute of Modern Physics, CAS for the direct plasma injection scheme. Shunt impedance is air important parameter when designing a 4-rod RFQ cavity, it reflects the RF efficiency of the cavity, and has a direct influence on the cost of the structure. Voltage distribution of a RFQ cavity has an effect on beam transmission, and particles would be lost if the actual voltage distribution is not as what, it should be. The influence of cell length, stern thickness and height on Shunt impedance and voltage distribution have been studied, in particular the effect of projecting electrodes has been investigated in detail.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

本文根据反冲质子法中子探头灵敏度标定实验和分层分块模型(LP)理论计算的局限性,提出了一个计算PIN中了探头高灵敏度的方法,即分层分块蒙特卡罗模拟联合模型(LPMC)。文中首先概述了灵敏度标定实验的原理、装置、方法、部分测量结果及其误差。接着分析了分层分块模型的使用范围。最后着重论述了用分层分块蒙特卡罗模拟联合模型计算反冲质子能谱和中子探头灵敏度的方法,并且与分层分块模型计算结果和实验测量结果进行了比较。根据计算过程,用FORTRAN77语言缩写了计算程序LPMC,其计算方法本身的误差不大于1.8%。LPMC计算结果与实验值在相对误差范围内符合,解决了LP理论对高灵敏度计算结果与实验值偏差过大的问题

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We have developed a new experimental system based on a microfluidic chip to determine severe acute respiratory syndrome coronavirus (SARS-Cov). The system includes a laser-induced fluorescence microfluidic chip analyzer, a glass microchip for both polymerase chain reaction (PCR) and capillary electrophoresis, a chip thermal cycler based on dual Peltier thermoelectric elements, a reverse transcription-polymerase chain reaction (RT-PCR) SARS diagnostic kit, and a DNA electrophoretic sizing kit. The system allows efficient cDNA amplification of SARS-CoV followed by electrophoretic sizing and detection on the same chip. To enhance the reliability of RT-PCR on SARS-CoV detection, duplex PCR was developed on the microchip. The assay was carried out on a home-made microfluidic chip system. The positive and the negative control were cDNA fragments of SARS-CoV and parainfluenza virus, respectively. The test results showed that 17 positive samples were obtained among 18 samples of nasopharyngeal swabs from clinically diagnosed SARS patients. However, 12 positive results from the same 18 samples were obtained by the conventional RT-PCR with agarose gel electrophoresis detection. The SARS virus species can be analyzed with high positive rate and rapidity on the microfluidic chip system.