An untuned MA-loaded cavity for HIRFL-CSR


Autoria(s): Mei, LR; Xu, Z; Yuan, YJ; Zhang, SH; Zhang, ZL; Zhang, C; Sun, LP; Jin, P; Yue, WM
Data(s)

2010

Resumo

In order to realize high energy density physics and plasma physics research at HIRFL-CSR, a magnetic alloy (MA)-loaded cavity has been studied. According to the theoretical calculation and simulation for the MA-loaded cavity, we achieved a better result. The MA-loaded cavity had a higher mu Q f value, with a higher shunt impedance and a higher accelerating gradient. The accelerating gradient was about 95 kV/m at 1.8003 MHz, 130 kV/m at 0.9000 MHz. Compared with the ferrite-loaded cavities that are used at HIRFL-CSR, with about 10 kV/m accelerating gradient, the MA-loaded cavity obviously has an advantage. The results of the theoretical calculation and the simulation, which meet the design requirements are in good agreement.

Identificador

http://ir.impcas.ac.cn/handle/113462/8079

http://www.irgrid.ac.cn/handle/1471x/133116

Idioma(s)

英语

Fonte

Mei, LR; Xu, Z; Yuan, YJ; Zhang, SH; Zhang, ZL; Zhang, C; Sun, LP; Jin, P; Yue, WM.An untuned MA-loaded cavity for HIRFL-CSR,CHINESE PHYSICS C,2010,34(8):1132-1135

Palavras-Chave #RF CAVITY
Tipo

期刊论文