261 resultados para 320-U1336B
Resumo:
Single crystal sapphire (Al2O3) samples implanted with 110 keV He and irradiated at 320 K by Pb-208(27), ions with energy of 1.1 MeV/u to the fluences ranging from 1 X 10(12) to 5 X 10(14) ion/cm(2) and subsequently annealed at 600, 900 and 1100 K. The obtained PL spectra showed that emission peaks centred at 375, 390, 413, and 450 nm appeared in irradiated samples. The peak of 390 ran became very intense after 600 K annealing. The peak of 390 nm weakened and 510 nm peak started to build up at 900 K annealing, the peak of 390 nm vanished and 510 nm peak increased with the annealing temperature rising to 1100 K. Infrared spectra showed a broadening of the absorption band between 460 cm(-1), and 510 cm(-1) indicating strongly damaged regions being formed in the Al2O3 samples and position shift of the absorption band at 1000-1300 cm(-1) towards higher wavenumber after Pb irradiation.
Resumo:
In the present work the photoluminescence (PL) character of sapphire implanted with 110-keV He, Ar or Ne ions and subsequently irradiated with 230-MeV Pb was studied. The implantation was performed at 320 and 600 K using fluences from 5.0 x 10(16) to 2.0 x 10(17) ions/cm(2). The Pb ion irradiation was carried out at 320 K. The obtained PL spectra showed peaks at 375, 413 and 450 nm with maximum intensity at an implantation fluence of 5.0 x 10(16) ions/cm(2) and a new peak at 390 nm appeared in the He-implanted and subsequently Pb-irradiated samples. Infrared spectra showed a broadening of the absorption band between 460 and 510 nm indicating strongly damaged regions formed in the Al2O3 samples. A possible PL mechanism is discussed.
Resumo:
简要介绍兰州重离子加速器国家实验室320 kV高压ECR实验平台原子分子物理终端上使用的一维位置灵敏法拉第筒的数据获取系统。该系统硬件由64通道电流/电压转换放大器和PCI-6224数据采集卡构成,并通过编写LabVIEW程序,实现数据的准确、同步、实时与高速采集。经验证,该获取系统简单易用,可靠性高,完全符合设计要求。
Resumo:
Polypyrrole nanostructure arrays, including simultaneously large quantities of nanowires and small quantities of partially filled nanotubules have been electrochemically synthesized in home-made etched ion-track polycarbonate (PC) templates. Diameter of the prepared nanostructures varies from 45 to 320 nm with their lengths up to 30 microns. Morphological studies of these nanostructures were performed by field emission scanning electron microscopy (FESEM), high resolution transmission electron microscopy (HRTEM) and Raman spectroscopy. While optical absorption properties were studied by ultraviolet-visible-near infrared spectrophotometry (UV-vis-NIR). It has been observed that the absorption maximum of polypyrrole shifts to the longer wavelength side as the diameter of these nanostructures (nanowires and nanotubules) increases. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
本文论述了高电荷态ECR离子源的最新进展和原理;介绍了10GHz ECR2高电荷态离子源的设计特点和调试结果。在此离子源上发现了ECR离子源的新工作模式和新约束场形,新工作模式不同于传统工作模式的地方是在ECR离子源引出端注入低能电子;推动等离子体电极到更靠近高电荷态离子的约束区域;移动等磁压面使ECR等离子体向引出区域移动。新工作模式使ECR离子束流强度大为提高,得到Ar8+离子430μA、Ar9+离子320μA、O6+离子450μA;微波利用系数增加;工作气体气耗量减少。本文对新工作模式原理进行了详细的分析和讨论,得出高电荷态ECR离子源的一个重要结论,即引出端低能电子的注入比在注入端注入更有效。 本文还进行了将连续激光蒸发技术应用到ECR离子源中的研究。在10GHz ECR2离子源中使用50W连续CO2激光蒸发金属铝,得到Al6+离子约50μA。在此基础上根据ECR离子源新工作模式原理,提出了在ECR离子源引出端使用热阴极电子枪的设想,并阐述了其工作原理和设计。在激光离子源实验中发现强激光产生的等离子体具有独特的性质,如方向性、脉冲性和漂移性。在实验中使用磁场约束激光等离子体而使离子总束流提高了5倍,并首次使用了高频再游离措施,发现效果很明显,使得离子总束流提高了3倍。由此可见,可以利用脉冲激光产生等离子体的一些特殊性质来研究和改善ECR离子源的一些基本性质。 此外,在本论文中还介绍了2.45GHz ECR离子源实验台的设计和初步调试。
Resumo:
A packed-bed electroosmotic pump (EOP) was constructed and evaluated. The EOP consisted of three capillary columns packed in parallel, a gas-releasing device, Pt electrodes and a high-voltage power supply. The EOP could generate output pressure above 5.0 MPa and constant flow rate in the range of nl/min to a few mul/min for pure water, pure methanol, 2 mM potassium dihydrogenphosphate buffer, the buffer-methanol mixture and the pure water-methanol mixture at applied potentials less than 20 W The composition of solvent before/after pumping was quantitatively determined by using a gas chromatograph equipped with both flame ionization detector and thermal conductivity detector. It was found that there were no apparent changes in composition and relative concentrations after pumping process for a methanol-ethanol-acetonitrile mixture and a methanol-water mixture. Theoretical aspect of the EOP was discussed in detail. An capillary HPLC system consisting of the EOP, an injection valve, a 15 cm x 320 mum i.d., 5 mum Spherigel C(18) stainless steel analytical column, and an on-column UV detector was connected to evaluate the performance of the EOP. A comparative study was also carried out with a mechanical capillary HPLC pump on the same system. The results demonstrated that the reproducibility of flow rate and the pulsation-free flow property of the EOP are superior to that of mechanical pump in capillary HPLC application. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
Long methacrylate monolithic columns (100 cm x 320 mum i.d.) were prepared from silanized fused-silica capillaries of 320 mum i.d. by in situ copolymerization of butyl methacrylate (BMA) with ethylene dimethacrylate (EDMA) in the presence of a suitable porogen. The separation performance and selectivity of the column were evaluated and compared with a 25 cm x 320 mum i.d. column prepared in the same way by capillary high-performance liquid chromatography (mu-HPLC) The results showed that the 1 m long monolithic column can generate 33 x 10(3) plate number and exhibited good permeability, higher sample loadability, and separation capability. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
The molar heat capacity of the azeotropic mixture composed of water and benzene was measured by an adiabatic calorimeter in the temperature range from 80 to 320 K. The phase transitions took place in the temperature range from 265.409 to 275.165 K and 275.165 to 279.399 K. The phase transition temperatures were determined to be 272.945 and 278.339 K, which were corresponding to the solid-liquid phase transitions of water and benzene, respectively. The thermodynamic functions and the excess thermodynamic functions of the mixture relative to standard temperature 298.15 K were derived from the relationships of the thermodynamic functions and the function of the measured heat capacity with respect to temperature.
Resumo:
应用梯度格局法在长白山北坡海拔700m-2600m的坡面上每100 m海拔设置一样地,共计20块样地,通过对同一群落各样方间的相异性测定,对各海拔植物群落的复杂性进行了分析。结果表明,以主林层乔木种的二元数据计算的结果,除亚高山岳桦林外,其它各海拔群落的样方间均表现出较高的相异性,特别是低海拔的阔叶红松林平均相异系数达0.74,明显高于其它植被类型;暗针叶林各群落间差异不大,相对而言1400 m群落样方间的相异性略高于其它群落,表现出过渡性群落树种组成的复杂性;岳桦林树种组成简单,样[(\267\275\274\344\322\262\261\355\317\326\263\366\275\317\270\337\265\304\\317\340\313\306\320\324\241\243)-0.1(\322\324\271\340\304\276\326\326\265\304\266\376\324\252\312\375\276\335\\274\306\313\343\265\304\310\272)]落内的相异性,虽低海拔的阔叶红松林总体上高于其它群落,但差异趋势并不像乔木种那么明显。以各草本植物与所有植物种的二元数据计算的各海拔群落内样方间的相异性,表现出非常相近的趋势,群落内样方间草本植物及所有植物种均以阔叶红松林及高山冻原差异最大,暗针叶林基本稳定于比较相近的水平。图3表1参8。
Resumo:
An electroosmotic pump (EOP) capable of generating pressure above 3 MPa and mul/min flow rate with reverse phase mobile phases of HPLC was constructed and evaluated. The pump consisted of three parallel connected fused silica capillary columns (25 cm x 320 mum I.D.) packed with 2 mum silica materials, hollow electrodes, a high voltage DC power supply, and. a liquid pressure transducer. The EOP was applied in a capillary liquid chromatographic system for mobile phase delivery instead of a mechanical pump. Standard samples containing thiourea, naphthalene, anthracene, phenanthrene and acetonitrile were separated on a 15 cm x 320 mum I.D. 5 mum Chromasil C-18 packed capillary column with acetonitrile/water as mobile phase. (C) 2003 Elsevier Science B.V. All rights reserved.
Resumo:
选用沉积物中5种典型氧化物矿物:针铁矿、磁铁矿、三水铝石、氧化铝、二氧化锰,以水培法和单一矿物吸附Cd为培养介质,以芦苇为受试植物,研究环境中不同化学形态Cd(即吸附在不同矿物表面)的生物有效性差别.经过45 d的培养,发现矿物吸附的Cd被芦苇吸收富集,不同形态Cd的富集强度不同,根组织富集量72.70~320.44 mg.kg-1,并遵循以下规律:Al(OH)3>Al2O3>Fe3O4>MnO2>FeOOH.Cd的富集特征反映了不同矿物吸附Cd能力和稳定性的差异,通过采用3种低分子量有机酸对Cd的解吸,评价了这几种矿物对镉的吸附强度.结果表明,Cd的解吸量遵循如下规律,乙酸、苹果酸:Al(OH)3>Fe3O4>Al2O3>FeOOH>MnO2;柠檬酸:Al(OH)3>Al2O3>Fe3O4>FeOOH>MnO2,这与芦苇对各种矿物吸附镉的富集程度顺序基本一致.Cd的化学形态是影响其生物有效性的重要因素.