162 resultados para Intracytoplasmic sperm injection


Relevância:

20.00% 20.00%

Publicador:

Resumo:

G chemically modified electrode (CME) was prepared by electrochemical copolymerization of pyrrole and Methylene Blue. The resulting CME exhibits effective electrocatalytic activity towards the oxidation of reduced nicotinamide coenzymes (NADH and NADPH),

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Amperometic flow measurements were made at +0.55 V (vs. Ag/AgCl) in 0.1 mol l-1 KOH electrolyte with an Ni(II) chemically modified electrode (CME) with an Eastman-AQ polymer film. The use and characteristics of a Ni(II)-containing crystalline and polymer-modified electrode obtained by a double coating step as a detector for amino acids in a flow-injection system using reversed-phase liquid chromatography are described. The detection of these analytes is based on the higher oxidation state of nickel (NiOOH) controlled by the applied potential. The electroanalytical parameters and the detection current for a series of amines and amino acids were investigated. The use of such a CME in the flow-injection technique was found to be suitable in a solution at low pH. The linear range for glycine is 5 X 10(-6)-0.1 mol 1-1 with a detection limit of 1.0 X 10(-6) mol l-1. A 1 X 10(-4) mol 1-1 mixture of serine and tyrosine was also detected after separation on an Nucleosil C18 column.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A glassy carbon electrode (GCE) modified with palladium provides excellent electrocatalytic oxidation of hydrogen peroxide. When the electrolyte contains palladium chloride and glucose oxidase, the GCE can be modified by electrochemical codeposition at a given potential. The resulting modified surface was coated with a thin film of Nation to form a glucose sensor. Such a glucose sensor was successfully used in the flow-injection analysis of glucose with high stability and anti-poisoning ability. It gave a detection limit of 1 X 10(-7) M injected glucose, with a linear concentration range of 0.001-8 mM. There is no obvious interference from substances such as ascorbate and saccharides.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Prussian Blue-modified glassy carbon electrode prepared by simple adsorption exhibited excellent electrocatalytic activity in the oxidation of hydrazine in acidic media. A film of the perfluorosulphonic acid polymer Nafion coated on top of the Prussian Blue-modified glassy carbon electrode can improve the mechanical stability of the Prussian Blue layer in the flow stream. Hydrazine was detected by flow-injection analysis at the modified electrode with high sensitivity. The limit of detection was 0.6 ng.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chemically modified electrodes prepared by treating the cobalt tetraphenylporphyrin modified glassy-carbon electrode at 750-degrees (HCME) are shown to catalyze the electrooxidation of hydrazine. The oxidation occurred at +0.63 V vs. Ag/AgCl (saturated potassium chloride) in pH 2.5 media. The catalytic response is evaluated with respect to solution pH, potential scan-rate, concentration dependence and flow-rate. The catalytic stability of the HCME is compared with that of the cobalt tetraphenylporphyrin adsorbed glassy-carbon electrode. The stability of the HCME was excellent in acidic solution and even in solutions containing organic solvent (50% CH3OH). When used as the sensing electrode in amperometric detection in flow-injection analysis, the HCME permitted sensitive detection of hydrazine at 0.5 V. The limit of detection was 0.1 ng. The linear range was from 50 ng to 2.4-mu-g. The method is very sensitive and selective.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel Eastman-AQ/Ni(II) chemically modified electrode (CME) produced by "double coating step" deposition of a poly(ester sulphonic acid) polymer film and Ni2+-containing crystalline species onto glassy carbon instead of a metallic nickel electrode exhibited stable electrocatalytic oxidation of numerous alpha-hydrogen compounds including carbohydrates, amines and amino acids. In cyclic voltammetry, the electrocatalysis appeared with an irreversible anodic wave at +0.55 V (vs. Ag/AgCl). The CME was adapted for constant-potential amperometric detection of these compounds in flow injection analysis. Using the CME, the linear response concentration range was between 1.0 x 10(-5) and 5.0 x 10(-2) mol/l and the detection limit was 5.0 x 10(-6) mol/l for glucose. The stability of the CME was adequate for routine quantitative application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An electrochemical detector based on a polyaniline conducting polymer chemically modified electrode (PAn CME) was developed for use in flow-injection analysis and ion chromatography. Iodide, bromide, thiocyanate and thiosulphate are detected by using ion chromatography with a PAn CME electrochemical detector. The detection limits are 1, 5, 10 and 10 mgl-1, respectively. The CME response for electroinactive anions varies selectively with the mobile phase composition in flow-injection analysis. By this approach, perchlorate, sulphate, nitrate, iodide, acetate and oxalate can be detected conveniently and reproducibly over a linear concentration range of at least 3 orders of magnitude. The electrode is stable for over 2 weeks with no evidence of chemical or mechanical deterioration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrodeposition of the phenothiazine mediator titrant toluidine blue onto a glassy carbon substrate at an appropriate potential was used to construct a toluidine blue chemically modified electrode (CME) exhibiting electrocatalytic reduction for myoglobin and hemoglobin. The CME catalyzed the hemoprotein electroreduction at the reduction potential of the mediator molecule. When the CME as used as a detector for flow injection analysis at a constant applied potential of -0.30 V vs. a saturated calomel electrode, it gave detection limits of 20 and 50 ng (1.2 and 0.78 pmol) injected myoglobin and hemoglobin, respectively, with a dynamic linear concentration range over 2 orders of magnitude. After a brief equilibration period, the CME retained nearly 90% of its initial myoglobin response over 8 hours of continuous exposure to the flow-through system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of chemically modified electrodes (CMEs) for liquid chromatography and flow-injection analysis is reviewed. Electrochemical detection with CMEs based on electrocatalysis, permselectivity, ion flow in redox films, and ion transfer across the water-solidified nitrobenzene interface is discussed in terms of improving the stability, selectivity, and scope of electrochemical detectors, and the detection of electroinactive substances. More than 90 references are included.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examined the effects of storage time and cryoprotectant concentrations on the post-thaw sperm of red seabream, Pagrus major. Sperm treated with 12%, 15%, 18% and 21% DMSO were cryopreserved for 10, 30, 60 and 360 days, and fertilization and hatching rates were analysed. For all groups, there were no differences in the fertilization rates and hatching rates between sperm cryopreserved for < 60 days and fresh sperm (98.8 +/- 0.8%, 96.4 +/- 1.3%). However, for sperm cryopreserved for 360 days, both fertilization rates (88.6 +/- 3.0% to 7.0 +/- 1.9%) and hatching rates (79.4 +/- 7.2% to 3.3 +/- 0.8%) decreased drastically. Furthermore, the cryoprotectant concentrations affected sperm quality significantly (P < 0.05). When cryopreserved for 360 days, sperm treated with 15% DMSO obtained the best results compared with other concentrations. We suggest that 15% DMSO may be an effective cryoprotectant for long-term sperm cryopreservation of red seabream.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and convenient protocol for the cryopreservation of the flounder (Paralichthys olivaceus) sperm was established for "on the spot" cryopreservation of large quantities of semen. The use of three cryoprotectants, dimethyl sulphoxide (DMSO), glycerol (Gly) and methanol was tested in the method. The percentage of motile sperm present in semen after it had been frozen and thawed in the presence of DMSO, Gly or methanol was 60.5 +/- 3.6, 79.17 +/- 4.5 and 13.25 +/- 4.7%, respectively. The fertilization rates of this sperm were 67.06 +/- 15.1, 76.20 +/- 10.0 and 44.93 +/- 22.6%, while the hatching rates of eggs fertilized with this sperm were 37.40 +/- 8.3, 48.18 +/- 25.7 and 23.35 +/- 10.8%, respectively. It was found that Gly and DMSO were better cryoprotectants than methanol, with Gly giving the best overall results. Under scanning electron microscopy, it could be seen that while the majority of the frozen-thawed sperm remained morphologically normal, some exhibited lost or dilated mitochondria, swollen mid-pieces, broken tails, or damaged cell membrane, which probably caused the decrease in motility and fertility of the frozen-thawed sperm. (C) 2003 Elsevier Science Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Large yellow croaker, Pseudosciaena crocea, exhibit sexually dimorphic growth, with females growing faster and reaching larger adult sizes than males. Thus, development of techniques for preferentially producing females is necessary to optimize production of these species. We have established a protocol to produce all-female croaker P. crocea through induction of meiotic gynogenesis with homologous sperm. The first set of experiments investigated the ultra-violet (UV) irradiation on sperm motility and duration of sperm activity to determine the optimal UV dosage for genetic inactivation of sperm, yet retaining adequate motility for activation of eggs. Milt from several males was diluted 1: 100 with Ringer's solution and UV irradiated with doses ranging from 0-150 J cm (-2). The results indicated that motility and duration of activity generally decreased with increased UV doses. At UV doses greater than 105 J cm(-2), after fertilization, motility was < 10% and fertilization rates were significantly lower. Highest hatching rate was obtained at 75 J cm -2. A second set of experiments was carried out to determine appropriate conditions of cold shock for retention of the 2nd polar body in P. crocea eggs after fertilization with UV-inactivated sperm by altering the timing, temperature and duration of shock. At 208 degrees C, shock applied at 3 min after fertilization resulted in higher survival rate of larvae at 6 h after hatching. Results of different combinations of three shock temperatures ( 28 degrees C, 38 degrees C or 48 degrees C) and five shock durations ( 4 min, 8 min, 12 min, 16 min or 20 min) at 3 min after fertilization demonstrated that shocks of 12 min gave highest production of diploid gynogens. Statistical analysis revealed that maximum production of diploid gynogens (44.55 +/- 2.99%) were obtained at 38 degrees C. The results of this study indicate that the use of UV-irradiated homologous sperm for activation of P. crocea eggs and cold shock for polar body retention is an effective method for producing gynogenetic offspring.