Resumo:
It has long been known that various ignition criteria of energetic materials have been limited in applicability to small regions. In order to explore the physical nature of ignition, we calculated how much thermal energy per unit mass of energetic materials was absorbed under different external stimuli. Hence, data of several typical sensitivity tests were analyzed by order of magnitude estimation. Then a new concept on critical thermal energy density was formulated. Meanwhile, the chemical nature of ignition was probed into by chemical kinetics.
Resumo:
Self-ignition tests of a model scramjet combustor were conducted by using parallel sonic injection of gaseous hydrogen from the base of a blade-like strut into a supersonic vitiated airstream. The range of stagnation pressure and temperature studied varied from 1.0 to 4.5 MPa and from 1300 to 2200 K, respectively. Experimental results show that the self-ignition limit, in terms of either global or local quantities of pressure and temperature, exhibits a nonmonotonic behavior resembling the classical homogeneous explosion limit of the hydrogen-oxygen system. Specifically, for a given temperature, increasing pressure from a low value can render a nonignitable mixture to first become ignitable, then nonignitable again, This correspondence shows that, despite the globally supersonic nonpremixed configuration studied herein, ignition is strongly influenced by the intricate chemical reaction mechanism and thereby exhibits the homogeneous explosion character. Consequently, self-ignition criteria based on a global reaction rate approximating the complex chemistry are inadequate. An auxiliary computational study on counterflow ignition was also conducted to systematically investigate the contamination effects of vitiated air. Results indicate that the net contamination effects for the present experimental data are expected to be substantially smaller than contributions from the individual contamination species because of the counterbalancing influences of the H2O-inhibition and NO-promotion reactions in effecting ignition.
Resumo:
A series of experiments were conducted to characterize the self-ignition and combustion of thermally cracked kerosene in both a Mach 2.5 model combustor with a combustor entrance height of 51 mm and a Mach 3.0 model combustor with an entrance height of 70 mm. A unique kerosene heating and delivery system was developed, which can prepare heated kerosene up to 950 K at a pressure of 5.5 MPa with negligible fuel coking. The extent of China no. 3 kerosene conversion under supercritical conditions was measured using a specially designed system. The compositions of gaseous products as a result of thermal cracking were analyzed using gas chromatography. The mass flow rates of cracked kerosene were also calibrated and measured using sonic nozzles. With the injection of thermally cracked kerosene, the ability to achieve enhanced combustion performance was demonstrated under a variety of airflow and fuel conditions. Furthermore, self-ignition tests of cracked kerosene in a Mach 2.5 model combustor over a range of fuel injection conditions and with the help of different amounts of pilot hydrogen were conducted and discussed.
Resumo:
Smoldering constitutes a significant fire risk both in normal gravity and in microgravity. This space experiment has been conducted aboard the China Recoverable Satellite SJ-8 to investigate smoldering characteristics of flexible polyurethane foam with central ignition in a forced flow of oxidizer. This configuration resulted in a combination of opposed and forward flow smolder. The microgravity experiment is rather unique in that it was performed at constant pressure, and with a relatively high ambient oxygen concentration (35% by volume). The smoldering characteristics are inferred from measurements of temperature histories at several locations along the foam sample. Particularly important is the discovery that there is a transition from smoldering to flaming near the sample end in the opposed smoldering. This transition seems to be caused by strong acceleration of the smoldering reaction. The observed transition serves to initiate a vigorous forward-propagating oxidation reaction in the char left behind by the smoldering reaction. The secondary char oxidation reaction propagates through the sample and consumes most of the remaining char. In forward flow smoldering, the oxidizer depletion by the upstream opposed smolder prevents an exothermic oxidation reaction from being established in the foam until this preceding reaction is completed. Once fresh oxidizer flows in the sample, the existing conditions are sufficient for a self-sustained forward smoldering reaction to take place.
Resumo:
JP-10 (exo-tetrahydrodicyclopentadiene, C10H16) ignition delay times were measured in a preheated shock tube. The vapor pressures of the JP-10 were measured directly by using a high-precision vacuum gauge, to remedy the difficulty in determining the gaseous concentrations of heavy hydrocarbon fuel arising from the adsorption on the wall in shock tube experiments. The whole variation of pressure and emission of the OH or CH radicals were observed in the ignition process by a pressure transducer and a photomultiplier with a monochromator. The emission of the OH or CH radicals was used to identify the time to ignition. Experiments were performed over the pressure range of 151-556 kPa, temperature range of 1000-2100 K, fuel concentrations of 0.1%-0.55% mole fraction, and stoichiometric ratios of 0.25, 0.5, 1.0 and 2.0. The experimental results show that for the lower and higher temperature ranges, there are different dependency relationships of the ignition time on the temperature and the concentrations of JP-10 and oxygen.
Resumo:
Self-ignition tests of a model scramjet combustor were conducted by using parallel sonic injection of gaseous hydrogen from the base of a blade-like strut into a supersonic airstream, The vitiated air was produced by burning H-2, O-2, and air to a stagnation temperature of 1000-2100 K and a stagnation pressure of 0.8-1.6 MPa, The effects of different parameters on the self-ignition limits were analyzed, In addition, the effects of the combustor's different wall configurations on self-ignition limits were specifically studied. It was found that the wall configurations of the combustor had a significant effect on self-ignition limits, which might have variations of 420-840 K deg in stagnation temperature; however, the local static temperature in the recirculation zones for different wall configurations remained the same at approximately 1100 K, It was found that self-ignition could initiate at the exit of the combustor and this can be considered as a weak self-ignition characteristic.
Resumo:
Experiments of direct initiation of hydrogen-oxygen by means of a hot turbulent jet were made. Results indicate that the length of ignition tube is the dominant factor in determining the ignition capability of hot turbulent jet, and that the ignition capability of turbulence jet increases with the length of ignition tube. Because this ignition capability can meet the demands of a gas-detonation-driver shock tunnel and it doesn't require additional facilities, the hot turbulent jet initiation method can be applied to large hydrogen-oxygen detonation-driver shock tunnels. Influences of obstacles on the ignition capability were also studied. It was found that the presence of obstacles weakens the ignition capability of a hot turbulent jet.
Resumo:
A hot particle jet is induced as a laser pulse from a free oscillated Nd:YAG laser focused on a coal target. The particle jet successfully initiates combustion in a premixed combustible gas consisting of hydrogen, oxygen, and air. The experiment reveals that the ionization of the particle jet is enhanced during the laser pulse. This characteristic is attributed to the electron cascade process and the ionization of the particles or molecules of the target. The initial free electrons, which are ablated from the coal target, are accelerated by the laser pulse through the inverse Bremsstrahlung process and then collide with the neutrals in the jet, causing the latter to be ionized.
Resumo:
In this paper, the first Chinese microgravity (μ-g) experimental study on coal combustion was introduced. An experimental system used to study the ignition process of single coal particles was built up, complying with the requirements of the 3.5 s drop tower in the National Microgravity Laboratory of China (NMLC). High volatile bituminous and lignite coal particles with diameter of 1.5 and 2.0 mm were tested. The ignition and combustion process was recorded by a color CCD and the particle surface temperature before and at the ignition was determined by the RGB colorimetric method. Comparative experiments were conducted at normal gravity (1-g). The experiments revealed that at different gravity levels, the ignition of all tested coal particles commenced in homogeneous phase, while the shape, structure, brightness and development of the flames, as well as the volatile matter release during the ignition process are different. At μ-g, the part of volatile was released as a jet, while such a phenomenon was barely observed at 1-g. Also, after ignition, flames were more spherical, thicker, laminated and dimmer at μ-g. It was confirmed that ignition temperature decreased as the particle size or volatile content increased. However, contradicted to existing experimental results, provided other experimental conditions except gravity level were the same, ignition temperature of coal particles was about 50–80 K lower at μ-g than that at 1-g.
Resumo:
We propose a foam cone-in-shell target design aiming at optimum hot electron production for the fast ignition. A thin low-density foam is proposed to cover the inner tip of a gold cone inserted in a fuel shell. An intense laser is then focused on the foam to generate hot electrons for the fast ignition. Element experiments demonstrate increased laser energy coupling efficiency into hot electrons without increasing the electron temperature and beam divergence with foam coated targets in comparison with solid targets. This may enhance the laser energy deposition in the compressed fuel plasma.
Resumo:
We report an experimental observation suggesting plasma channel formation by focusing a relativistic laser pulse into a long-scale-length preformed plasma. The channel direction coincides with the laser axis. Laser light transmittance measurement indicates laser channeling into the high-density plasma with relativistic self-focusing. A three-dimensional particle-in-cell simulation reproduces the plasma channel and reveals that the collimated hot-electron beam is generated along the laser axis in the laser channeling. These findings hold the promising possibility of fast heating a dense fuel plasma with a relativistic laser pulse.
Resumo:
We propose to utilize the leading pulse of a petawatt class laser to create a conic plasma channel in the dense plasmas. This plasma channel could serve as a natural cone to guide the main pulse to the cone tip, as behaves similarly to the physical Au cone. We estimate that the leading pulse of a petawatt laser could create a natural cone with cone tip only about 100 mu m away from the edge of compressed core plasma. The natural cone formation should be compatible for a good uniform compression and efficient fast heating of the imploded fuel.
Resumo:
An experimental study on ignition and combustion of single particles was conducted at normal gravity (1-g) and microgravity (l-g) for three high volatile coals with initial diameter of 1.5 and 2.0 mm, respectively. The non-intrusive twin-color pyrometry method was used to retrieve the surface temperature of the coal particle through processing the images taken by a color CCD camera. At the same time, a mathematical model considering thermal conduction inside the coal particle was developed to simulate the ignition process. Both experiments and modeling found that ignition occurred homogeneously at the beginning and then heterogeneously for the testing coal particles burning at l-g. Experimental results confirmed that ignition temperature decreased with increasing volatile content and increasing particle size. However, contradicted to previous studies, this study found that for a given coal with certain particle size, ignition temperature was about 50–80 K lower at l-g than that at 1-g. The model predictions agreed well with the l-g experimental data on ignition temperature. The criterion that the temperature gradient in the space away from the particle surface equaled to zero was validated to determine the commence of homogeneous ignition. Thermal conduction inside the particle could have a noticeable effect for determining the ignition temperature. With the consideration of thermal conduction, the critical size for the phase transient from homogeneous to heterogeneous is about 700 lm at ambient temperature 1500 K and oxygen concentration 0.23. 2009 The Combustion Institute. Published by Elsevier Inc. All rights reserved.
Resumo:
An improved method for the determination of phosphorus in natural waters, aquatic organisms and sediments by ignition method is proposed. The recoveries of phosphorus (P) from selected inorganic and organic P-containing compound standards after ignition with different auxiliaries, such as MgSO4, Mg(NO3)(2), MgO2, Mg(Ac-2) and CaCl2, were compared. We found that the phosphorus from most compound standards could not be completely recovered when these compounds were ignited (450-500degreesC) with the MgSO4 as auxiliary and the baked residue was extracted with 0.2 mol l(-1) HCl for 30min at 80degreesC or at room temperature. P recoveries, for example, were poor, less than 85%, if pyrophosphate and metaphosphate were ignited with the addition Of MgSO4 prior to the extraction of the baked residue with 0.2 mol l(-1) HCl at 80degreesC for 30 min. In contrast, MgO2, Mg(Ac)(2) and CaCl2, as well as Mg(NO3)(2), could all yield complete P recoveries at routine ashing temperatures (450-500degreesC). The results demonstrate that MgC12 is a more effective auxiliary agent for the determination of phosphorus in natural waters, aquatic organisms and sediments by ignition method than MgSO4 which is commonly used. (C) 2003 Elsevier Science Ltd. All rights reserved.