7 resultados para internal stress

em Archivo Digital para la Docencia y la Investigación - Repositorio Institucional de la Universidad del País Vasco


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new smart concrete aggregate design as a candidate for applications in structural health monitoring (SHM) of critical elements in civil infrastructure is proposed. The cement-based stress/strain sensor was developed by utilizing the stress/strain sensing properties of a magnetic microwire embedded in cement-based composite (MMCC). This is a contact-less type sensor that measures variations of magnetic properties resulting from stress variations. Sensors made of these materials can be designed to satisfy the specific demand for an economic way to monitor concrete infrastructure health. For this purpose, we embedded a thin magnetic microwire in the core of a cement-based cylinder, which was inserted into the concrete specimen under study as an extra aggregate. The experimental results show that the embedded MMCC sensor is capable of measuring internal compressive stress around the range of 1-30 MPa. Two stress sensing properties of the embedded sensor under uniaxial compression were studied: the peak amplitude and peak position of magnetic switching field. The sensitivity values for the amplitude and position within the measured range were 5 mV/MPa and 2.5 mu s/MPa, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Revised 2006-06

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We studied the effect of magnetoelastic anisotropy on domain wall (DW) dynamics and remagnetization process of magnetically bistable Fe-Co-rich microwires with metallic nucleus diameters (from 1.4 to 22 mu m). We manipulated the magnetoelastic anisotropy applying the tensile stresses and changing the magnetostriction constant and strength of the internal stresses. Microwires of the same composition of metallic nucleus but with different geometries exhibit different magnetic field dependence of DW velocity with different slopes. Application of stresses resulted in decrease of the DW velocity, v, and DW mobility, S. Quite fast DW propagation (v until 2,500 m/s at H about 30 A/m) has been observed in low magnetostrictive magnetically bistable Co56Fe8Ni10Si10B16 microwires. Consequently, we observed certain correlation between the magnetoelastic energy and DW dynamics in microwires: decreasing the magnetoelastic energy, K (me), DW velocity increases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Overactivation of ionotropic glutamate receptors in oligodendrocytes induces cytosolic Ca2+ overload and excitotoxic death, a process that contributes to demyelination and multiple sclerosis. Excitotoxic insults cause well-characterized mitochondrial alterations and endoplasmic reticulum (ER) dysfunction, which is not fully understood. In this study, we analyzed the contribution of ER-Ca2+ release through ryanodine receptors (RyRs) and inositol triphosphate receptors (IP(3)Rs) to excitotoxicity in oligodendrocytes in vitro. First, we observed that oligodendrocytes express all previously characterized RyRs and IP(3)Rs. Blockade of Ca2+-induced Ca2+ release by TMB-8 following alpha-amino-3-hydroxyl-5-methyl-4-isoxazole-propionate (AMPA) receptor-mediated insults attenuated both oligodendrocyte death and cytosolic Ca2+ overload. In turn, RyR inhibition by ryanodine reduced as well the Ca2+ overload whereas IP3R inhibition was ineffective. Furthermore, AMPA-triggered mitochondrial membrane depolarization, oxidative stress and activation of caspase-3, which in all instances was diminished by RyR inhibition. In addition, we observed that AMPA induced an ER stress response as revealed by alpha subunit of the eukaryotic initiation factor 2 alpha phosphorylation, overexpression of GRP chaperones and RyR-dependent cleavage of caspase-12. Finally, attenuating ER stress with salubrinal protected oligodendrocytes from AMPA excitotoxicity. Together, these results show that Ca2+ release through RyRs contributes to cytosolic Ca2+ overload, mitochondrial dysfunction, ER stress and cell death following AMPA receptor-mediated excitotoxicity in oligodendrocytes. Cell Death and Disease (2010) 1, e54; doi:10.1038/cddis.2010.31; published online 15 July 2010

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The evaluation and comparison of internal cluster validity indices is a critical problem in the clustering area. The methodology used in most of the evaluations assumes that the clustering algorithms work correctly. We propose an alternative methodology that does not make this often false assumption. We compared 7 internal cluster validity indices with both methodologies and concluded that the results obtained with the proposed methodology are more representative of the actual capabilities of the compared indices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La actividad aseguradora supone la transferencia de riesgos del asegurado al asegurador. El asegurador se compromete al pago de una prestación si el riesgo se realiza. Se produce un cambio en el ciclo productivo. El asegurador vende una cobertura sin conocer el momento y el coste exacto de dicha cobertura. Esta particularidad de la actividad aseguradora explica la necesidad para una entidad aseguradora de ser solvente en cada momento y ante cualquier imprevisto. Por ello, la solvencia de las entidades aseguradoras es un aspecto que se ha ido recogiendo en las distintas normativas que han regulado la actividad aseguradora y al que se ha ido dando cada vez más importancia. Actualmente la legislación vigente en materia de solvencia de las aseguradoras esta regulada por la directiva europea Solvencia I. Esta directiva establece dos conceptos para garantizar la solvencia: las provisiones técnicas y el margen de solvencia. Las provisiones técnicas son las calculadas para garantizar la solvencia estática de la compañía, es decir aquella que hace frente, en un instante temporal determinado, a los compromisos asumidos por la entidad. El margen de solvencia se destina a cubrir la solvencia dinámica, aquella que hace referencia a eventos futuros que puedan afectar la capacidad del asegurador. Sin embargo en una corriente de gestión global del riesgo en la que el sector bancario ya se había adelantado al sector asegurador con la normativa Basilea II, se decidió iniciar un proyecto europeo de reforma de Solvencia I y en noviembre del 2009 se adoptó la directiva 2009/138/CE del parlamento europeo y del consejo, sobre el seguro de vida, el acceso a la actividad de seguro y de reaseguro y su ejercicio mas conocida como Solvencia II. Esta directiva supone un profundo cambio en las reglas actuales de solvencia para las entidades aseguradoras. Este cambio persigue el objetivo de establecer un marco regulador común a nivel europeo que sea más adaptado al perfil de riesgo de cada entidad aseguradora. Esta nueva directiva define dos niveles distintos de capital: el SCR (requerimiento estándar de capital de solvencia) y el MCR (requerimiento mínimo de capital). Para el calculo del SCR se ha establecido que el asegurador tendrá la libertad de elegir entre dos modelos. Un modelo estándar propuesto por la Autoridad Europea de Seguros y Pensiones de Jubilación (EIOPA por sus siglas en inglés), que permitirá un calculo simple, y un modelo interno desarrollado por la propia entidad que deberá ser aprobado por las autoridades competentes. También se contempla la posibilidad de utilizar un modelo mixto que combine ambos, el estándar y el interno. Para el desarrollo del modelo estándar se han realizado una serie de estudios de impacto cuantitativos (QIS). El último estudio (QIS 5) ha sido el que ha planteado de forma más precisa el cálculo del SCR. Plantea unos shocks que se deberán de aplicar al balance de la entidad con el objetivo de estresarlo, y en base a los resultados obtenidos constituir el SCR. El objetivo de este trabajo es realizar una síntesis de las especificaciones técnicas del QIS5 para los seguros de vida y realizar una aplicación práctica para un seguro de vida mixto puro. En la aplicación práctica se determinarán los flujos de caja asociados a este producto para calcular su mejor estimación (Best estimate). Posteriormente se determinará el SCR aplicando los shocks para los riesgos de mortalidad, rescates y gastos. Por último, calcularemos el margen de riesgo asociado al SCR. Terminaremos el presente TFG con unas conclusiones, la bibliografía empleada así como un anexo con las tablas empleadas.