19 resultados para impedance audiometry

em Archivo Digital para la Docencia y la Investigación - Repositorio Institucional de la Universidad del País Vasco


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nanostructured FeNi-based multilayers are very suitable for use as magnetic sensors using the giant magneto-impedance effect. New fields of application can be opened with these materials deposited onto flexible substrates. In this work, we compare the performance of samples prepared onto a rigid glass substrate and onto a cyclo olefin copolymer flexible one. Although a significant reduction of the field sensitivity is found due to the increased effect of the stresses generated during preparation, the results are still satisfactory for use as magnetic field sensors in special applications. Moreover, we take advantage of the flexible nature of the substrate to evaluate the pressure dependence of the giant magneto-impedance effect. Sensitivities up to 1 Omega/Pa are found for pressures in the range of 0 to 1 Pa, demostrating the suitability of these nanostructured materials deposited onto flexible substrates to build sensitive pressure sensors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recent advances in technology involving magnetic materials require development of novel advanced magnetic materials with improved magnetic and magneto-transport properties and with reduced dimensionality. Therefore magnetic materials with outstanding magnetic characteristics and reduced dimensionality have recently gained much attention. Among these magnetic materials a family of thin wires with reduced geometrical dimensions (of order of 1-30 mu m in diameter) have gained importance within the last few years. These thin wires combine excellent soft magnetic properties (with coercivities up to 4 A/m) with attractive magneto-transport properties (Giant Magneto-impedance effect, GMI, Giant Magneto-resistance effect, GMR) and an unusual re-magnetization process in positive magnetostriction compositions exhibiting quite fast domain wall propagation. In this paper we overview the magnetic and magneto-transport properties of these microwires that make them suitable for microsensor applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: The main goals of the present study were: 1) to review some recommendations about how to increase lean body mass; 2) to analyse whether following scientific sources of current recommendations, visible changes can be shown or not in a participant (body composition, strength and blood analyses). METHODS: One male athlete completed 12 weeks of resistance training program and following a diet protocol. Some test were determined such as, strength 6RM, blood analyses, skindfold measurements, body perimeters and impedance test. Body composition measurements were taken 3 times during the program (before-T1, after 6 weeks of intervention period-T2 and at the end of the program-T3). On the other hand, strength tests and blood analyses were performed twice (before and after the program). RESULTS: Strength was increased in general; blood analyses showed that Creatine kinase was increased a 104% and Triglycerides level was decreased a 22.5%; in the impedance test, body mass (1.6%), lean body mass (3.5%) and Body mass index (1.7%) were increased, whereas fat mass was decreased (15.5%); relaxed and contracted biceps perimeters were also increased. CONCLUSION: A muscle hypertrophy training program mixed with an appropriate diet during 12 weeks leads to interesting adaptations related to increase in body weight, lean body mass, biceps perimeters, strength and creatine kinase levels, and a decrease in fat mass.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La revista permite a los autores reutilizar su fichero para depositarlo en su web o repositorio institucional, sin ánimo de lucro y mencionando la fuente original.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tesis leida en la Universidad de Aberdeen. 178 p.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

[EU]Proiektu honetan bihotz-biriketako berpizte masajearen bular-sakadek elektrokardiograman eta bular-inpedantziaren seinaleetan eragindako interferentziaren azterketa egiten da. Helburu nagusia bi interferentzia hauen arteko erlazioa aztertzea da, horretarako tresna garatuz. Erlazio hau definitzeak interferentziaren eragina txikitzeko modua aurkitzen lagunduko luke, eta honek berpizteko aukerak handituko lituzke. Proiektua gauzatzeko ospitalez kanpoko geldialdien erregistro multzo batetik abiatuta datu-base propioa garatu da ezarritako irizpide batzuk jarraituz. Datu-base berri hau 37 pazienteren 237 mozketak osatzen dute, 10 segundotako luzera minimoarekin non pazienteek asistolia bitarteko kanpoko bular masajea jasotzen duten. Bestalde, interferentzia ezaugarritzeko interfaze grafiko bat garatu da, elektrokardiograma eta bular-inpedantziaren seinaleak denboran eta maiztasunean erakutsi eta hauen parametro esanguratsuak automatikoki zein eskuz ateratzeko aukera ematen duena. Parametroak seinaleen sakada bakoitzeko maximo eta minimoak, beraien kokapenak eta oinarrizko maiztasuna, bere harmonikoak eta hauen anplitudeak dira. Tresna hau erabiliz aipatutako datu-baseko episodioen prozesaketa egin da. Bukatzeko, lortutako emaitzak tratatzeko bigarren interfaze grafiko bat garatu da, non emaitzen banaketa estatistikoa eta hauen arteko erlazio lineala aztertzen diren. Proiektuaren ekarpen nagusia, beraz, bihotz-biriketako berpizte masajeak eragindako interferentzia aztertzeko tresna ahaltsuaren garapena da, jatorri desberdineko bestelako berpizte episodioak aztertzeko ere balio duena.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

[ES]Hoy en día las muertes por parada cardiorrespiratoria superan en número a otras más mediáticas como aquellas que se producen por incendios o en accidentes de tráfico, y sin embargo su repercusión es mucho menor. Este hecho debe ser motivo de preocupación ya que, con una correcta formación de la población en materia de resucitación cardíaca, muchas de estas muertes podrían ser evitadas. Con el objetivo de reducir estas estadísticas han surgido multitud de estudios y proyectos de investigación consistentes en tratar de mejorar las herramientas disponibles tanto para personal sanitario como no sanitario. En este marco se encuadra el proyecto presentado en este documento, consistente en la sensorización de un maniquí de entrenamiento para episodios de parada cardiorrespiratoria, el cual ofrecerá la posibilidad de analizar con detalle el artifact o interferencia generada por el rescatador sobre el paciente en el momento de efectuar la maniobra de resucitación, así como la interferencia causada por el contacto electrodo-piel. Paralelamente podrá ser utilizado como mero instrumento de entrenamiento para posibles situaciones reales. El porqué de la utilización de este tipo de maniquíes reside principalmente en la imposibilidad de emplear personas debido a las posibles lesiones torácicas que pueden ocurrir por las compresiones realizadas. Finalmente debe citarse el hecho de que no es imprescindible tener conocimientos médicos para poder aplicar las técnicas básicas de resucitación cardíaca, acción que incrementa las posibilidades de supervivencia de un paciente de manera excepcional, ya que cada minuto que pasa desde la parada cardiorrespiratoria la probabilidad de supervivencia disminuye en un porcentaje significativamente elevado. Tomando como base lo descrito hasta ahora, en este documento se detalla la solución técnica de la sensorización de un maniquí genérico para la adquisición de las señales de fuerza de compresión, aceleración sufrida por el pecho en tres ejes ortogonales, profundidad de compresión, impedancia entre los dos electrodos colocados sobre el pecho del paciente y señal electrocardiográfica emitida por el corazón; además, se incluye la posibilidad de inyectar una señal electrocardiográfica previamente grabada. La base de registros obtenida de estos ensayos podrá ser utilizada posteriormente para su análisis, ya que su similitud con señales extraídas en un caso real es máxima.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A central question in Neuroscience is that of how the nervous system generates the spatiotemporal commands needed to realize complex gestures, such as handwriting. A key postulate is that the central nervous system (CNS) builds up complex movements from a set of simpler motor primitives or control modules. In this study we examined the control modules underlying the generation of muscle activations when performing different types of movement: discrete, point-to-point movements in eight different directions and continuous figure-eight movements in both the normal, upright orientation and rotated 90 degrees. To test for the effects of biomechanical constraints, movements were performed in the frontal-parallel or sagittal planes, corresponding to two different nominal flexion/abduction postures of the shoulder. In all cases we measured limb kinematics and surface electromyographic activity (EMB) signals for seven different muscles acting around the shoulder. We first performed principal component analysis (PCA) of the EMG signals on a movement-by-movement basis. We found a surprisingly consistent pattern of muscle groupings across movement types and movement planes, although we could detect systematic differences between the PCs derived from movements performed in each sholder posture and between the principal components associated with the different orientations of the figure. Unexpectedly we found no systematic differences between the figute eights and the point-to-point movements. The first three principal components could be associated with a general co-contraction of all seven muscles plus two patterns of reciprocal activatoin. From these results, we surmise that both "discrete-rhythmic movements" such as the figure eight, and discrete point-to-point movement may be constructed from three different fundamental modules, one regulating the impedance of the limb over the time span of the movement and two others operating to generate movement, one aligned with the vertical and the other aligned with the horizontal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

[EU]Inpedantzia altuko babes sistema teknika sinplea da non korronte transformadoreak behar dituen babes eskema osatzeko. Korronte transformadore hauek ukondoko tentsio altua, magnetizazio ezaugarri antzekoak eta transformazio erlazio berdina izan behar dute. KT guztiak babestutako objektuaren amaieran jarri behar dira. Fase bakoitzari dagozkion KT guztiak paraleloan konektatu behar dira eta KT guztien juntura puntuan neurri adarra jarri behar da.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

[ES]El objetivo del presente trabajo es realizar un estado del arte sobre las faltas de alta impedancia en sistemas de distribución, sus características, causas y consecuencias. El estudio se acompaña con simulaciones software que se llevarán a cabo mediante el software Matlab a través de un modelo que represente su carácter no lineal y aleatorio.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

[ES]El objetivo principal de TFG es analizar y comparar el funcionamiento de las protecciones diferenciales de baja impedancia de generador y de transformador de potencia. Para ello, se describirán sus características principales de forma teórica y se realizarán simulaciones mediante el módulo SimPowersSystems contenido en Matlab.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

[Es]En este proyecto se analizan el diseño y la evaluación de dos métodos para la supresión de la interferencia generada por las compresiones torácicas proporcionadas por el dispositivo mecánico LUCAS, en el electrocardiograma (ECG) durante el masaje de resucitación cardiopulmonar. El objetivo es encontrar un método que elimine el artefacto generado en el ECG de una manera efectiva, que permita el diagnóstico fiable del ritmo cardiaco. Encontrar un método eficaz sería de gran ayuda para no tener que interrumpir el masaje de resucitación para el análisis correcto del ritmo cardiaco, lo que supondría un aumento en las probabilidades de resucitación. Para llevar a cabo el proyecto se ha generado una base de datos propia partiendo de registros de paradas cardiorrespiratorias extra-hospitalarias. Esta nueva base de datos contiene 410 cortes correspondientes a 86 pacientes, siendo todos los episodios de 30 segundos de duración y durante los cuales el paciente, recibe masaje cardiaco. Por otro lado, se ha desarrollado una interfaz gráfica para caracterizar los métodos de supresión del artefacto. Esta, muestra las señales del ECG, de impedancia torácica y del ECG tras eliminar el artefacto en tiempo. Mediante esta herramienta se han procesado los registros aplicando un filtro adaptativo y un filtro de coeficientes constantes. La evaluación de los métodos se ha realizado en base a la sensibilidad y especificidad del algoritmo de clasificación de ritmos con las señales ECG filtradas. La mayor aportación del proyecto, por tanto, es el desarrollo de una potente herramienta eficaz para evaluar métodos de supresión del artefacto causado en el ECG por las compresiones torácicas al realizar el masaje de resucitación cardiopulmonar, y su posterior diagnóstico. Un instrumento que puede ser implementado para analizar episodios de resucitación de cualquier tipo de procedencia y capaz de integrar nuevos métodos de supresión del artefacto.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

[EN]Hyperventilation, which is common both in-hospital and out-of-hospital cardiac arrest, decreases coronary and cerebral perfusion contributing to poorer survival rates in both animals and humans. Current resucitation guidelines recommend continuous monitoring of exhaled carbon dioxide (CO2) during cardiopulmonary resucitation (CPR) and emphasize good quality of CPR, including ventilations at 8-10 min1. Most of commercial monitors/de- brilators incorporate methods to compute the respiratory rate based on capnography since it shows uctuations caused by ventilations. Chest compressions may induce artifacts in this signal making the calculation of the respiratory rate di cult. Nevertheless, the accuracy of these methods during CPR has not been documented yet. The aim of this project is to analyze whether the capnogram is reliable to compute ventilation rate during CPR. A total of 91 episodes, 63 out-of-hospital cardiac arrest episodes ( rst database) and 28 in-hospital cardiac arrest episodes (second database) were used to develop an algorithm to detect ventilations in the capnogram, and the nal aim is to provide an accurate ventilation rate for feedback purposes during CPR. Two graphic user interfaces were developed to make the analysis easier and another two were adapted to carry out this project. The use of this interfaces facilitates the managment of the databases and the calculation of the algorithm accuracy. In the rst database, as gold standard every ventilation was marked by visual inspection of both the impedance, which shows uctuations with every ventilation, and the capnography signal. In the second database, volume of the respiratory ow signal was used as gold standard to mark ventilation instants since it is not a ected by chest compressions. The capnogram was preprocessed to remove high frequency noise, and the rst di erence was computed to de ne the onset of inspiration and expiration. Then, morphological features were extracted and a decission algorithm built based on the extracted features to detect ventilation instants. Finally, ventilation rate was calculated using the detected instants of ventilation. According to the results obtained in this project, the capnogram can be reliably used to give feedback ventilation rate, and therefore, on hyperventilation in a resucitation scenario.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ES]El proyecto descrito en este documento consiste en la investigación sobre la viabilidad de detección automática de pulso y respiración a partir de la señal de aceleración, medida mediante un acelerómetro posicionado bien en la carótida o en el pecho del paciente. El motivo de la utilización de la aceleración está principalmente en el bajo costo y por la tecnología sencilla de los acelerómetros. En este documento se explica cómo se ha montado una plataforma para la adquisición de las señales de aceleración y el electrocardiograma emitido por el corazón, en sujetos sanos. Con la base de señales adquirida se ha diseñado un método basado en el dominio de la frecuencia para detectar la presencia de pulso y respiración. Los resultados son prometedores y confirman la posibilidad de desarrollar estos detectores. Las herramientas desarrolladas podrán ser utilizadas para análisis futuros y para seguir avanzando en este estudio.