4 resultados para Foam Prototyping

em Archivo Digital para la Docencia y la Investigación - Repositorio Institucional de la Universidad del País Vasco


Relevância:

10.00% 10.00%

Publicador:

Resumo:

[EU]Hiru dimentsioko inprimaketa etorkizun handiko teknologia bezala azaltzen zaigu gaur egun. Esate baterako, biomedikuntza arloan aukera berritzaileak ekar ditzake, baina baita hezkuntza, heziketa eta ikerketa munduetan ere. Teknologia berri honen abantailarik nagusiena prototipatze azkarrean datza, eta honi esker, mikro- eta makro- egitura definituak dituzten objektuak diseinatu eta fabrikatu daitezke modu lehiakorrean. Lan honen helburua 3D inprimagailu baten bitartez inprimaturiko polimero biobateragarri eta biodegradagarrietan oinarrituriko ereduen garapen eta fabrikazioan datza. Hala ere, lehenik eta behin, lehengaiak bai fisikoki eta bai termikoki karakterizatu behar dira, ondoren, 3D inprimagailuaren parametroen arteko erlazioa ezarri, eta azkenik, produktu finalaren egitura propietateak eta kalitatea aztertu. Aipaturiko lana aurrera eramateko erabili den materiala polilaktida (PLA) izan da, zeinen erabilera oso zabaldua dagoen medikuntza arloan inplante (torloju, iltze, plaka eta abar) moduan eta ehun ingeniaritzaren munduan.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: Aerosol delivery holds potential to release surfactant or perfluorocarbon (PFC) to the lungs of neonates with respiratory distress syndrome with minimal airway manipulation. Nevertheless, lung deposition in neonates tends to be very low due to extremely low lung volumes, narrow airways and high respiratory rates. In the present study, the feasibility of enhancing lung deposition by intracorporeal delivery of aerosols was investigated using a physical model of neonatal conducting airways. Methods: The main characteristics of the surfactant and PFC aerosols produced by a nebulization system, including the distal air pressure and air flow rate, liquid flow rate and mass median aerodynamic diameter (MMAD), were measured at different driving pressures (4-7 bar). Then, a three-dimensional model of the upper conducting airways of a neonate was manufactured by rapid prototyping and a deposition study was conducted. Results: The nebulization system produced relatively large amounts of aerosol ranging between 0.3 +/- 0.0 ml/min for surfactant at a driving pressure of 4 bar, and 2.0 +/- 0.1 ml/min for distilled water (H(2)Od) at 6 bar, with MMADs between 2.61 +/- 0.1 mu m for PFD at 7 bar and 10.18 +/- 0.4 mu m for FC-75 at 6 bar. The deposition study showed that for surfactant and H(2)Od aerosols, the highest percentage of the aerosolized mass (similar to 65%) was collected beyond the third generation of branching in the airway model. The use of this delivery system in combination with continuous positive airway pressure set at 5 cmH(2)O only increased total airway pressure by 1.59 cmH(2)O at the highest driving pressure (7 bar). Conclusion: This aerosol generating system has the potential to deliver relatively large amounts of surfactant and PFC beyond the third generation of branching in a neonatal airway model with minimal alteration of pre-set respiratory support.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

[ES]El objetivo principal de este proyecto consiste en desarrollar una librería en Matlab- Simulink correspondiente a un OBD (Sistema de diagnóstico a bordo) para el vehículo eléctrico. Se pretende comprobar el correcto funcionamiento de la librería ejecutando el software en tiempo real mediante un PLC proporcionado por Tecnalia, realizando la comunicación entre PLC y PC mediante bus CAN. En este contexto, la ejecución del proyecto seguiría la metodología de software del ciclo en V con las siguientes fases principales: Desarrollo de las comunicaciones en Simulink (Plataforma PC).Implementación del software en plataformas de prototipado rápido (Dspace). Validación y testeo. Implementación final en DSP.