2 resultados para storage control

em CaltechTHESIS


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Diffusible proteins regulate neural development at a variety of stages. Using a novel neuronal culture assay, I have identified several cytokines that regulate the expression of neurotransmitters and neuropeptides in sympathetic neurons. These cytokines fall into two families. The first group is termed the neuropoietic cytokines, while including CDF/LIF, CNTF, OSM and GPA, induces expression of the same set of neuropeptide mRNAs in cultured sympathetic neurons. These four factors not only exhibit similar biological activities; they also share a predicted secondary structure and bind to a signal-transducing receptor subunit in common with IL-6 and IL-11. The latter two cytokines display a weaker activity in this assay. In addition, I find that several members of the TGF-β superfamily, activin A, BMP-2, and BMP-6, have a selective overlap with the neuropoietic family in the spectrum of neuropeptides that these cytokines induce in sympathetic neurons. Different patterns of neuropeptides induced by the TGF-β family members, however, demonstrate that the activities of these cytokines are distinct from those of the neuropoietic family. Another 30 cytokines are without detectable effect in this neuronal assay.

Activin A induces a set of neurotransmitters and neuropeptides that is somewhat similar to the phenotype of sympathetic neurons innervating sweat glands in rat footpads. In situ hybridization and RNase protection were carried out to test whether activins were involved in the phenotypic transition when sympathetic neurons contact sweat glands. I find that activin mRNA is present in both cholinergic and noradrenergic targets. Moreover, homogenates of footpads do not contain activin-like activity in the neuronal assay in vitro. Taken together, these data do not support activins as the best candidates for the sweat gland factor.

Several novel factors that regulate neuropeptide expression exist in heart cell conditioned medium. I attempted to purify these factors in collaboration with Dr. Jane Talvenheimo. Our results suggest that these factors are sensitive to the storage conditions used. Several modifications of purification strategy are discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Two trends are emerging from modern electric power systems: the growth of renewable (e.g., solar and wind) generation, and the integration of information technologies and advanced power electronics. The former introduces large, rapid, and random fluctuations in power supply, demand, frequency, and voltage, which become a major challenge for real-time operation of power systems. The latter creates a tremendous number of controllable intelligent endpoints such as smart buildings and appliances, electric vehicles, energy storage devices, and power electronic devices that can sense, compute, communicate, and actuate. Most of these endpoints are distributed on the load side of power systems, in contrast to traditional control resources such as centralized bulk generators. This thesis focuses on controlling power systems in real time, using these load side resources. Specifically, it studies two problems.

(1) Distributed load-side frequency control: We establish a mathematical framework to design distributed frequency control algorithms for flexible electric loads. In this framework, we formulate a category of optimization problems, called optimal load control (OLC), to incorporate the goals of frequency control, such as balancing power supply and demand, restoring frequency to its nominal value, restoring inter-area power flows, etc., in a way that minimizes total disutility for the loads to participate in frequency control by deviating from their nominal power usage. By exploiting distributed algorithms to solve OLC and analyzing convergence of these algorithms, we design distributed load-side controllers and prove stability of closed-loop power systems governed by these controllers. This general framework is adapted and applied to different types of power systems described by different models, or to achieve different levels of control goals under different operation scenarios. We first consider a dynamically coherent power system which can be equivalently modeled with a single synchronous machine. We then extend our framework to a multi-machine power network, where we consider primary and secondary frequency controls, linear and nonlinear power flow models, and the interactions between generator dynamics and load control.

(2) Two-timescale voltage control: The voltage of a power distribution system must be maintained closely around its nominal value in real time, even in the presence of highly volatile power supply or demand. For this purpose, we jointly control two types of reactive power sources: a capacitor operating at a slow timescale, and a power electronic device, such as a smart inverter or a D-STATCOM, operating at a fast timescale. Their control actions are solved from optimal power flow problems at two timescales. Specifically, the slow-timescale problem is a chance-constrained optimization, which minimizes power loss and regulates the voltage at the current time instant while limiting the probability of future voltage violations due to stochastic changes in power supply or demand. This control framework forms the basis of an optimal sizing problem, which determines the installation capacities of the control devices by minimizing the sum of power loss and capital cost. We develop computationally efficient heuristics to solve the optimal sizing problem and implement real-time control. Numerical experiments show that the proposed sizing and control schemes significantly improve the reliability of voltage control with a moderate increase in cost.