3 resultados para comparison method

em CaltechTHESIS


Relevância:

30.00% 30.00%

Publicador:

Resumo:

With the installation by the Pacific Electric Railway of a bus system in Pasadena to supplant most of its trolley lines, the problem of the comparison of the costs of the two systems naturally presented itself. The study here undertaken was originally started as just a comparison of the motor bus and Birney Safety Car, but as the work progressed it seemed advisable to include the trolley bus as well - a method of transportation that is comparatively new as far as development is concerned, but which seems to be finding increasing favor in the East.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This report presents the results of an investigation of a method of underwater propulsion. The propelling system utilizes the energy of a small mass of expanding gas to accelerate the flow of a large mass of water through an open ended duct of proper shape and dimensions to obtain a resultant thrust. The investigation was limited to making a large number of runs on a hydroduct of arbitrary design, varying between wide limits the water flow and gas flow through the device, and measuring the net thrust caused by the introduction and expansion of the gas.

In comparison with the effective exhaust velocity of about 6,000 feet per second observed in rocket motors, this hydroduct model attained a maximum effective exhaust velocity of more than 27,000 feet per second, using nitrogen gas. Using hydrogen gas, effective exhaust velocities of 146,000 feet per second were obtained. Further investigation should prove this method of propulsion not only to be practical but very efficient.

This investigation was conducted at Project No. 1, Guggenheim Aeronautical Laboratory, California Institute of Technology, Pasadena, California.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Absolute f-values for 7 transitions in the first spectra of 4 elements have been measured using the atomic beam absorption technique. The equivalent widths of the absorption lines are measured with a photoelectric scanner and the atomic beam density is determined by continuously weighing a part of it with a sensitive automatic microbalance. The complete theory is presented and corrections are calculated to cope with gas absorption by the deposit on the microbalance pan and atoms which do not stick to the pan. An additional correction for the failure of the assumption of effusive flow in the formation of the atomic beam at large densities has been measured experimentally.

The following f-values were measured:

Fe: fλ3720 = 0.0430 ± 8%

Cu: fλ3247 = 0.427 ± 4.5%, fλ3274 = 0.206 ± 4.7%, fλ2492 = 0.0037 ± 9%

Cd: fλ3261 = 0.00190 ± 7%, fλ2288 = 1.38 ± 12%

Au: fλ2428 = 0.283 ± 5.3%

Comparison with other accurately measured f-values, where they exist, shows agreement within experimental errors.