2 resultados para Vaporization, Heats of

em CaltechTHESIS


Relevância:

90.00% 90.00%

Publicador:

Resumo:

The disolvated proton, H(OH2)2+ is employed as a chemical reagent in low pressure (˂ 10-5 torr) investigations by ion cyclotron resonance spectroscopy. Since termolecular reactions are absent at low pressure, disolvated protons are not generally observed. However H(OH2)2+ is produced in a sequence of bimolecular reactions in mixtures containing H2O and one of a small number of organohalide precursors. Then a series of hydrated Lewis bases is produced by H3O+ transfer from H(OH2)2+. In Chapter II, the relative stability of hydrated bases containing heteroatoms of both first and second row elements is determined from the preferred direction of H3O+ transfer between BH(OH2)+ complexes. S and P containing bases are shown to bind H3O+ more weakly than O and N bases with comparable proton affinities. A simple model of hydrogen bonding is proposed to account for these observations.

H+ transfer from H(OH2)2+ to several Lewis bases also occurs at low pressure. In Chapter III the relative importance of H3O+ transfer and H+ transfer from H(OH2)2+ to a series of bases is observed to be a function of base strength. Beginning with CH3COOH, the weakest base for which H+ transfer is observed, the importance of H+ transfer increases with increasing proton affinity of the acceptor base. The nature of neutral products formed from H(OH2)2+ by loss of H+ is also considered.

Chapters IV and V deal with thermochemistry of small fluorocarbons determined by photoionization mass spectrometry. The enthalpy of formation of CF2 is considered in Chapter IV. Photoionization of perfluoropropylene, perfluorocyclopropane, and trifluoromethyl benzene yield onsets for ions formed by loss of a CF2 neutral fragment. Earlier determinations of ΔH°f298 (CF2) are reinterpreted using updated thermochemical values and compared with results of this study. The heat of formation of neutral perfluorocyclopropane is also derived. Finally, the energetics of interconversion of perfluoropropylene and perfluorocyclopropane are considered for both the neutrals and their molecular ions.

In Chapter V the heats of formation of CF3+ and CF3I+are derived from photoionization of CF3I. These are considered with respect to ion-molecule reactions observed in CF3I monitored by the techniques of ion cyclotron resonance spectroscopy. Results obtained in previous experiments are also compared.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Part I

The latent heat of vaporization of n-decane is measured calorimetrically at temperatures between 160° and 340°F. The internal energy change upon vaporization, and the specific volume of the vapor at its dew point are calculated from these data and are included in this work. The measurements are in excellent agreement with available data at 77° and also at 345°F, and are presented in graphical and tabular form.

Part II

Simultaneous material and energy transport from a one-inch adiabatic porous cylinder is studied as a function of free stream Reynolds Number and turbulence level. Experimental data is presented for Reynolds Numbers between 1600 and 15,000 based on the cylinder diameter, and for apparent turbulence levels between 1.3 and 25.0 per cent. n-heptane and n-octane are the evaporating fluids used in this investigation.

Gross Sherwood Numbers are calculated from the data and are in substantial agreement with existing correlations of the results of other workers. The Sherwood Numbers, characterizing mass transfer rates, increase approximately as the 0.55 power of the Reynolds Number. At a free stream Reynolds Number of 3700 the Sherwood Number showed a 40% increase as the apparent turbulence level of the free stream was raised from 1.3 to 25 per cent.

Within the uncertainties involved in the diffusion coefficients used for n-heptane and n-octane, the Sherwood Numbers are comparable for both materials. A dimensionless Frössling Number is computed which characterizes either heat or mass transfer rates for cylinders on a comparable basis. The calculated Frössling Numbers based on mass transfer measurements are in substantial agreement with Frössling Numbers calculated from the data of other workers in heat transfer.