The cells of the specialized mating structures of the nematode Caenorhabditis elegans adult male tail develop from sex-specific divisions of postembryonic blast cells. One male-specific blast cell, B, is the precursor to all the cells of the copulatory spicules. Both cell interactions and autonomous fate specification mechanisms are utilized in the B lineage to specify fate.

During development the anterior daughter of B, B.a, generates four distinct pairs of cells. Cell ablation experiments indicate that the cells of each pair respond to positional cues provided by other male-specific blast cells. F and U promote anterior fates, Y.p promotes some posterior fates, and the B.a progeny promote posterior fates. The cells within each pair may also interact.

The lin-3/let-23 signalling pathway, identified for its function in C. elegans hermaphrodite vulval induction, mediates the signal from F and U. Reduction-of-function mutations in lin-3 (EGF-like signal), let-23 (receptor), sem-5 (adaptor), let-60 (ras), or lin-45 (raf) disrupt the fates of the anterior cells, and mimic F and U ablation. In addition, ectopically expressed lin-3 disrupts the fates of the posterior cells, and can promote anterior fates even in the absence of F and U.

A genetic screen of over 9000 mutagenized gametes recovered 22 mutations in 20 loci that disrupt fate specification in male tail lineages. Seven of these mutations may represent new genes that play a role in male tail development.

The first division of the B cell is asymmetric. The gene vab-3 is required for specification of B.a fates, and it may represent a factor whose activity is localized to the B.a cell via the gene lin-17. lin-17 acts both at the first division of the B cell and at specific other cell divisions in the lineage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Among the branches of astronomy, radio astronomy is unique in that it spans the largest portion of the electromagnetic spectrum, e.g., from about 10 MHz to 300 GHz. On the other hand, due to scientific priorities as well as technological limitations, radio astronomy receivers have traditionally covered only about an octave bandwidth. This approach of "one specialized receiver for one primary science goal" is, however, not only becoming too expensive for next-generation radio telescopes comprising thousands of small antennas, but also is inadequate to answer some of the scientific questions of today which require simultaneous coverage of very large bandwidths.

This thesis presents significant improvements on the state of the art of two key receiver components in pursuit of decade-bandwidth radio astronomy: 1) reflector feed antennas; 2) low-noise amplifiers on compound-semiconductor technologies. The first part of this thesis introduces the quadruple-ridged flared horn, a flexible, dual linear-polarization reflector feed antenna that achieves 5:1-7:1 frequency bandwidths while maintaining near-constant beamwidth. The horn is unique in that it is the only wideband feed antenna suitable for radio astronomy that: 1) can be designed to have nominal 10 dB beamwidth between 30 and 150 degrees; 2) requires one single-ended 50 Ohm low-noise amplifier per polarization. Design, analysis, and measurements of several quad-ridged horns are presented to demonstrate its feasibility and flexibility.

The second part of the thesis focuses on modeling and measurements of discrete high-electron mobility transistors (HEMTs) and their applications in wideband, extremely low-noise amplifiers. The transistors and microwave monolithic integrated circuit low-noise amplifiers described herein have been fabricated on two state-of-the-art HEMT processes: 1) 35 nm indium phosphide; 2) 70 nm gallium arsenide. DC and microwave performance of transistors from both processes at room and cryogenic temperatures are included, as well as first-reported measurements of detailed noise characterization of the sub-micron HEMTs at both temperatures. Design and measurements of two low-noise amplifiers covering 1--20 and 8—50 GHz fabricated on both processes are also provided, which show that the 1--20 GHz amplifier improves the state of the art in cryogenic noise and bandwidth, while the 8--50 GHz amplifier achieves noise performance only slightly worse than the best published results but does so with nearly a decade bandwidth.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Optical microscopy is an essential tool in biological science and one of the gold standards for medical examinations. Miniaturization of microscopes can be a crucial stepping stone towards realizing compact, cost-effective and portable platforms for biomedical research and healthcare. This thesis reports on implementations of bright-field and fluorescence chip-scale microscopes for a variety of biological imaging applications. The term “chip-scale microscopy” refers to lensless imaging techniques realized in the form of mass-producible semiconductor devices, which transforms the fundamental design of optical microscopes.

Our strategy for chip-scale microscopy involves utilization of low-cost Complementary metal Oxide Semiconductor (CMOS) image sensors, computational image processing and micro-fabricated structural components. First, the sub-pixel resolving optofluidic microscope (SROFM), will be presented, which combines microfluidics and pixel super-resolution image reconstruction to perform high-throughput imaging of fluidic samples, such as blood cells. We discuss design parameters and construction of the device, as well as the resulting images and the resolution of the device, which was 0.66 µm at the highest acuity. The potential applications of SROFM for clinical diagnosis of malaria in the resource-limited settings is discussed.

Next, the implementations of ePetri, a self-imaging Petri dish platform with microscopy resolution, are presented. Here, we simply place the sample of interest on the surface of the image sensor and capture the direct shadow images under the illumination. By taking advantage of the inherent motion of the microorganisms, we achieve high resolution (~1 µm) imaging and long term culture of motile microorganisms over ultra large field-of-view (5.7 mm × 4.4 mm) in a specialized ePetri platform. We apply the pixel super-resolution reconstruction to a set of low-resolution shadow images of the microorganisms as they move across the sensing area of an image sensor chip and render an improved resolution image. We perform longitudinal study of Euglena gracilis cultured in an ePetri platform and image based analysis on the motion and morphology of the cells. The ePetri device for imaging non-motile cells are also demonstrated, by using the sweeping illumination of a light emitting diode (LED) matrix for pixel super-resolution reconstruction of sub-pixel shifted shadow images. Using this prototype device, we demonstrate the detection of waterborne parasites for the effective diagnosis of enteric parasite infection in resource-limited settings.

Then, we demonstrate the adaptation of a smartphone’s camera to function as a compact lensless microscope, which uses ambient illumination as its light source and does not require the incorporation of a dedicated light source. The method is also based on the image reconstruction with sweeping illumination technique, where the sequence of images are captured while the user is manually tilting the device around any ambient light source, such as the sun or a lamp. Image acquisition and reconstruction is performed on the device using a custom-built android application, constructing a stand-alone imaging device for field applications. We discuss the construction of the device using a commercial smartphone and demonstrate the imaging capabilities of our system.

Finally, we report on the implementation of fluorescence chip-scale microscope, based on a silo-filter structure fabricated on the pixel array of a CMOS image sensor. The extruded pixel design with metal walls between neighboring pixels successfully guides fluorescence emission through the thick absorptive filter to the photodiode layer of a pixel. Our silo-filter CMOS image sensor prototype achieves 13-µm resolution for fluorescence imaging over a wide field-of-view (4.8 mm × 4.4 mm). Here, we demonstrate bright-field and fluorescence longitudinal imaging of living cells in a compact, low-cost configuration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RTKs-mediated signaling systems and the pathways with which they interact (e.g., those initiated by G protein-mediated signaling) involve a highly cooperative network that sense a large number of cellular inputs and then integrate, amplify, and process this information to orchestrate an appropriate set of cellular responses. The responses include virtually all aspects of cell function, from the most fundamental (proliferation, differentiation) to the most specialized (movement, metabolism, chemosensation). The basic tenets of RTK signaling system seem rather well established. Yet, new pathways and even new molecular players continue to be discovered. Although we believe that many of the essential modules of RTK signaling system are rather well understood, we have relatively little knowledge of the extent of interaction among these modules and their overall quantitative importance.

My research has encompassed the study of both positive and negative signaling by RTKs in C. elegans. I identified the C. elegans S0S-1 gene and showed that it is necessary for multiple RAS-mediated developmental signals. In addition, I demonstrated that there is a SOS-1-independent signaling during RAS-mediated vulval differentiation. By assessing signal outputs from various triple mutants, I have concluded that this SOS-1-independent signaling is not mediated by PTP-2/SHP-2 or the removal of inhibition by GAP-1/ RasGAP and it is not under regulation by SLI-1/Cb1. I speculate that there is either another exchange factor for RASor an as yet unidentified signaling pathway operating during RAS-mediated vulval induction in C. elegans.

In an attempt to uncover the molecular mechanisms of negative regulation of EGFR signaling by SLI-1/Cb1, I and two other colleagues codiscovered that RING finger domain of SLI-1 is partially dispensable for activity. This structure-function analysis shows that there is an ubiquitin protein ligase-independent activity for SLI-1 in regulating EGFR signaling. Further, we identified an inhibitory tyrosine of LET-23/ EGFR requiring sli-1(+)for its effects: removal of this tyrosine closely mimics loss of sli-1 but not loss of other negative regulator function.

By comparative analysis of two RTK pathways with similar signaling mechanisms, I have found that clr-1, a previously identified negative regulator of egl-15 mediated FGFR signaling, is also involved in let-23 EGFR signaling. The success of this approach promises a similar reciprocal test and could potentially extend to the study of other signaling pathways with similar signaling logic.

Finally, by correlating the developmental expression of lin-3 EGF to let-23 EGFR signaling activity, I demonstrated the existence of reciprocal EGF signaling in coordinating the morphogenesis of epithelia. This developmental logic of EGF signaling could provide a basis to understand a universal mechanism for organogenesis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An investigation was conducted to estimate the error when the flat-flux approximation is used to compute the resonance integral for a single absorber element embedded in a neutron source.

The investigation was initiated by assuming a parabolic flux distribution in computing the flux-averaged escape probability which occurs in the collision density equation. Furthermore, also assumed were both wide resonance and narrow resonance expressions for the resonance integral. The fact that this simple model demonstrated a decrease in the resonance integral motivated the more detailed investigation of the thesis.

An integral equation describing the collision density as a function of energy, position and angle is constructed and is subsequently specialized to the case of energy and spatial dependence. This equation is further simplified by expanding the spatial dependence in a series of Legendre polynomials (since a one-dimensional case is considered). In this form, the effects of slowing-down and flux depression may be accounted for to any degree of accuracy desired. The resulting integral equation for the energy dependence is thus solved numerically, considering the slowing down model and the infinite mass model as separate cases.

From the solution obtained by the above method, the error ascribable to the flat-flux approximation is obtained. In addition to this, the error introduced in the resonance integral in assuming no slowing down in the absorber is deduced. Results by Chernick for bismuth rods, and by Corngold for uranium slabs, are compared to the latter case, and these agree to within the approximations made.