2 resultados para Disagreement

em CaltechTHESIS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

While some of the deepest results in nature are those that give explicit bounds between important physical quantities, some of the most intriguing and celebrated of such bounds come from fields where there is still a great deal of disagreement and confusion regarding even the most fundamental aspects of the theories. For example, in quantum mechanics, there is still no complete consensus as to whether the limitations associated with Heisenberg's Uncertainty Principle derive from an inherent randomness in physics, or rather from limitations in the measurement process itself, resulting from phenomena like back action. Likewise, the second law of thermodynamics makes a statement regarding the increase in entropy of closed systems, yet the theory itself has neither a universally-accepted definition of equilibrium, nor an adequate explanation of how a system with underlying microscopically Hamiltonian dynamics (reversible) settles into a fixed distribution.

Motivated by these physical theories, and perhaps their inconsistencies, in this thesis we use dynamical systems theory to investigate how the very simplest of systems, even with no physical constraints, are characterized by bounds that give limits to the ability to make measurements on them. Using an existing interpretation, we start by examining how dissipative systems can be viewed as high-dimensional lossless systems, and how taking this view necessarily implies the existence of a noise process that results from the uncertainty in the initial system state. This fluctuation-dissipation result plays a central role in a measurement model that we examine, in particular describing how noise is inevitably injected into a system during a measurement, noise that can be viewed as originating either from the randomness of the many degrees of freedom of the measurement device, or of the environment. This noise constitutes one component of measurement back action, and ultimately imposes limits on measurement uncertainty. Depending on the assumptions we make about active devices, and their limitations, this back action can be offset to varying degrees via control. It turns out that using active devices to reduce measurement back action leads to estimation problems that have non-zero uncertainty lower bounds, the most interesting of which arise when the observed system is lossless. One such lower bound, a main contribution of this work, can be viewed as a classical version of a Heisenberg uncertainty relation between the system's position and momentum. We finally also revisit the murky question of how macroscopic dissipation appears from lossless dynamics, and propose alternative approaches for framing the question using existing systematic methods of model reduction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The growth of bulky and platelet shaped α-monoclinic crystals is discussed. A simple method is devised for identifying and orienting them.

The density, previously in disagreement with the value calculated from x-ray studies, is carefully redetermined, and found to be in good agreement with the latter.

The relative dielectric constant is determined, an effort being made to eliminate errors inherent in previous measurements, which have not been in agreement. A two parameter model is derived which explains the anisotropy in the relative dielectric constant of orthorhombic sulfur, which is also composed of 8-atom puckered ring molecules. The model works less well for α-monoclinic selenium. The relative dielectric constant anisotropy is quite noticeable, being 6.06 along the crystal b axis, and 8.52-8.93 normal to the axis.

Thin crystal platelets of α-monoclinic selenium (less than 1µ thick) are used to extend optical transmission measurements up to 4.5eV. Previously the measurements extended up to 2.1 eV, limited by the thickness of the available crystals. The absorption edge is at 2.20 eV, with changes in slope of the absorption coefficient occurring at 2.85 eV and 3.8 eV. Measurement of transmission through solutions of selenium in CS_2 and trichlorethylene yield an absorption edge of 2.75 eV. There is evidence the selenium exists in solution partly as Se_8 rings, the building block of monoclinic selenium. Transmission is measured at low temperatures (80°K and 10°K) using the platelets. The absorption edge is at 2.38 eV and 2.39 eV, respectively, for the two temperatures. Measurements at low temperatures with polarized and unpolarized light reveal interesting absorption anisotropy near 2.65 eV.