6 resultados para Atomic contacts
em CaltechTHESIS
Resumo:
I. HgSe is deposited on various semiconductors, forming a semimetal/semiconductor "Schottky barrier" structure. Polycrystalline, evaporated HgSe produces larger Schottky barrier heights on n-type semiconductors than does Au, the most electronegative of the elemental metals. The barrier heights are about 0.5 eV greater than those of Au on ionic semiconductors such as ZnS, and 0.1 to 0.2 eV greater for more covalently bonded semiconductors. A novel structure,which is both a lattice matched heterostructure and a Schottky barrier, is fabricated by epitaxial growth of HgSe on CdSe using hydrogen transport CVD. The Schottky barrier height for this structure is 0.73 ± 0.02 eV, as measured by the photoresponse method. This uncertainty is unusually small; and the magnitude is greater by about a quarter volt than is achievable with Au, in qualitative agreement with ionization potential arguments.
II . The Schottky barrier height of Au on chemically etched n-Ga1-x AlxAs was measured as a function of x. As x increases, the barrier height rises to a value of about 1.2 eV at x ≈ 0.45 , then decreases to about 1.0 eV as x approaches 0.83. The barrier height deviates in a linear way from the value predicted by the "common anion" rule as the AlAs mole fraction increases. This behavior is related to chemical reactivity of the Ga1-x AlxAs surface.
Resumo:
Improved measurement of the neutrino mass via β decay spectroscopy requires the development of new energy measurement techniques and a new β decay source. A promising proposal is to measure the β energy by the frequency of the cyclotron radiation emitted in a magnetic field and to use a high purity atomic tritium source. This thesis examines the feasibility of using a magnetic trap to create and maintain such a source. We demonstrate that the loss rate due to β decay heating is not a limiting factor for the design. We also calculate the loss rate due to evaporative cooling and propose that the tritium can be cooled sufficiently during trap loading as to render this negligible. We further demonstrate a design for the magnetic field which produces a highly uniform field over a large fraction of the trap volume as needed for cyclotron frequency spectroscopy while still providing effective trapping.
Resumo:
G-protein coupled receptors (GPCRs) form a large family of proteins and are very important drug targets. They are membrane proteins, which makes computational prediction of their structure challenging. Homology modeling is further complicated by low sequence similarly of the GPCR superfamily.
In this dissertation, we analyze the conserved inter-helical contacts of recently solved crystal structures, and we develop a unified sequence-structural alignment of the GPCR superfamily. We use this method to align 817 human GPCRs, 399 of which are nonolfactory. This alignment can be used to generate high quality homology models for the 817 GPCRs.
To refine the provided GPCR homology models we developed the Trihelix sampling method. We use a multi-scale approach to simplify the problem by treating the transmembrane helices as rigid bodies. In contrast to Monte Carlo structure prediction methods, the Trihelix method does a complete local sampling using discretized coordinates for the transmembrane helices. We validate the method on existing structures and apply it to predict the structure of the lactate receptor, HCAR1. For this receptor, we also build extracellular loops by taking into account constraints from three disulfide bonds. Docking of lactate and 3,5-dihydroxybenzoic acid shows likely involvement of three Arg residues on different transmembrane helices in binding a single ligand molecule.
Protein structure prediction relies on accurate force fields. We next present an effort to improve the quality of charge assignment for large atomic models. In particular, we introduce the formalism of the polarizable charge equilibration scheme (PQEQ) and we describe its implementation in the molecular simulation package Lammps. PQEQ allows fast on the fly charge assignment even for reactive force fields.
Resumo:
The electron diffraction investigation of the following compounds has been carried out: sulfur, sulfur nitride, realgar, arsenic trisulfide, spiropentane, dimethyltrisulfide, cis and trans lewisite, methylal, and ethylene glycol.
The crystal structures of the following salts have been determined by x-ray diffraction: silver molybdateand hydrazinium dichloride.
Suggested revisions of the covalent radii for B, Si, P, Ge, As, Sn, Sb, and Pb have been made, and values for the covalent radii of Al, Ga, In, Ti, and Bi have been proposed.
The Schomaker-Stevenson revision of the additivity rule for single covalent bond distances has been used in conjunction with the revised radii. Agreement with experiment is in general better with the revised radii than with the former radii and additivity.
The principle of ionic bond character in addition to that present in a normal covalent bond has been applied to the observed structures of numerous molecules. It leads to a method of interpretation which is at least as consistent as the theory of multiple bond formation.
The revision of the additivity rule has been extended to double bonds. An encouraging beginning along these lines has been made, but additional experimental data are needed for clarification.
Resumo:
The cataphoretic purification of helium was investigated for binary mixtures of He with Ar, Ne, N2, O2, CO, and CO2 in DC glow discharge. An experimental technique was developed to continuously measure the composition in the anode end-bulb without sample withdrawal. Discharge currents ranged from 10 ma to 100 ma. Total gas pressure ranged from 2 torr to 9 torr. Initial compositions of the minority component in He ranged from 1.2 mole percent to 7.5 mole percent.
The cataphoretic separation of Ar and Ne from He was found to be in agreement with previous investigators. The cataphoretic separation of N2, O2, and CO from He was found to be similar to noble gas systems in that the steady-state separation improved with (1) increasing discharge current, (2) increasing gas pressure, and (3) decreasing initial composition of the minority component. In the He-CO2 mixture, the CO2 dissociated to CO plus O2. The fraction of CO2 dissociated was directly proportional to the current and pressure and independent of initial composition.
The experimental results for the separation of Ar, Ne, N2, O2, and CO from He were interpreted in the framework of a recently proposed theoretical model involving an electrostatic Peclet number. In the model the electric field was assumed to be constant. This assumption was checked experimentally and the maximum variation in electric field was 35% in time and 30% in position. Consequently, the assumption of constant electric field introduced no more than 55% variation in the electrostatic Peclet number during a separation.
To aid in the design of new cataphoretic systems, the following design criteria were developed and tested in detail: (1) electric field independent of discharge current, (2) electric field directly proportional to total pressure, (3) ion fraction of impurity directly proportional to discharge current, and (4) ion fraction of impurity independent of total pressure. Although these assumptions are approximate, they enabled the steady-state concentration profile to be predicted to within 25% for 75% of the data. The theoretical model was also tested with respect to the characteristic time associated with transient cataphoresis. Over 80% of the data was within a factor of two of the calculated characteristic times.
The electrostatic Peclet number ranged in value from 0.13 to 4.33. Back-calculated ion fractions of the impurity component ranged in value from 4.8x10-6 to 178x10-6.
Resumo:
Absolute f-values for 7 transitions in the first spectra of 4 elements have been measured using the atomic beam absorption technique. The equivalent widths of the absorption lines are measured with a photoelectric scanner and the atomic beam density is determined by continuously weighing a part of it with a sensitive automatic microbalance. The complete theory is presented and corrections are calculated to cope with gas absorption by the deposit on the microbalance pan and atoms which do not stick to the pan. An additional correction for the failure of the assumption of effusive flow in the formation of the atomic beam at large densities has been measured experimentally.
The following f-values were measured:
Fe: fλ3720 = 0.0430 ± 8%
Cu: fλ3247 = 0.427 ± 4.5%, fλ3274 = 0.206 ± 4.7%, fλ2492 = 0.0037 ± 9%
Cd: fλ3261 = 0.00190 ± 7%, fλ2288 = 1.38 ± 12%
Au: fλ2428 = 0.283 ± 5.3%
Comparison with other accurately measured f-values, where they exist, shows agreement within experimental errors.