2 resultados para 301
em CaltechTHESIS
Resumo:
The influence upon the basic viscous flow about two axisymmetric bodies of (i) freestream turbulence level and (ii) the injection of small amounts of a drag-reducing polymer (Polyox WSR 301) into the test model boundary layer was investigated by the schlieren flow visualization technique. The changes in the type and occurrence of cavitation inception caused by the subsequent modifications in the viscous flow were studied. A nuclei counter using the holographic technique was built to monitor freestream nuclei populations and a few preliminary tests investigating the consequences of different populations on cavitation inception were carried out.
Both test models were observed to have a laminar separation over their respective test Reynolds number ranges. The separation on one test model was found to be insensitive to freestream turbulence levels of up to 3.75 percent. The second model was found to be very susceptible having its critical velocity reduced from 30 feet per second at a 0.04 percent turbulence level to 10 feet per second at a 3.75 percent turbulence level. Cavitation tests on both models at the lowest turbulence level showed the value of the incipient cavitation number and the type of cavitation were controlled by the presence of the laminar separation. Cavitation tests on the second model at 0.65 percent turbulence level showed no change in the inception index, but the appearance of the developed cavitation was altered.
The presence of Polyox in the boundary layer resulted in a cavitation suppression comparable to that found by other investigators. The elimination of the normally occurring laminar separation on these bodies by a polymer-induced instability in the laminar boundary layer was found to be responsible for the suppression of inception.
Freestream nuclei populations at test conditions were measured and it was found that if there were many freestream gas bubbles the normally present laminar separation was elminated and travelling bubble type cavitation occurred - the value of the inception index then depended upon the nuclei population. In cases where the laminar separation was present it was found that the value of the inception index was insensitive to the free stream nuclei populations.
Resumo:
Measurements of friction and heat transfer coefficients were obtained with dilute polymer solutions flowing through electrically heated smooth and rough tubes. The polymer used was "Polyox WSR-301", and tests were performed at concentrations of 10 and 50 parts per million. The rough tubes contained a close-packed, granular type of surface with roughness-height-to-diameter ratios of 0.0138 and 0.0488 respectively. A Prandtl number range of 4.38 to 10.3 was investigated which was obtained by adjusting the bulk temperature of the solution. The Reynolds numbers in the experiments were varied from =10,000 (Pr= 10.3) to 250,000 (Pr= 4.38).
Friction reductions as high as 73% in smooth tubes and 83% in rough tubes were observed, accompanied by an even more drastic heat transfer reduction (as high as 84% in smooth tubes and 93% in rough tubes). The heat transfer coefficients with Polyox can be lower for a rough tube than for a smooth one.
The similarity rules previously developed for heat transfer with a Newtonian fluid were extended to dilute polymer solution pipe flows. A velocity profile similar to the one proposed by Deissler was taken as a model to interpret the friction and heat transfer data in smooth tubes. It was found that the observed results could be explained by assuming that the turbulent diffusivities are reduced in smooth tubes in the vicinity of the wall, which brings about a thickening of the viscous layer. A possible mechanism describing the effect of the polymer additive on rough pipe flow is also discussed.