10 resultados para operation mode
em Universidad Politécnica de Madrid
Resumo:
The optical and radio-frequency spectra of a monolithic master-oscillator power-amplifier emitting at 1.5 ?m have been analyzed in a wide range of steady-state injection conditions. The analysis of the spectral maps reveals that, under low injection current of the master oscillator, the device operates in two essentially different operation modes depending on the current injected into the amplifier section. The regular operation mode with predominance of the master oscillator alternates with lasing of the compound cavity modes allowed by the residual reflectance of the amplifier front facet. The quasi-periodic occurrence of these two regimes as a function of the amplifier current has been consistently interpreted in terms of a thermally tuned competition between the modes of the master oscillator and the compound cavity modes.
Resumo:
This paper presents an automatic modulation classifier for electronic warfare applications. It is a pattern recognition modulation classifier based on statistical features of the phase and instantaneous frequency. This classifier runs in a real time operation mode with sampling rates in excess of 1 Gsample/s. The hardware platform for this application is a Field Programmable Gate Array (FPGA). This AMC is subsidiary of a digital channelised receiver also implemented in the same platform.
Resumo:
Analysis of big amount of data is a field with many years of research. It is centred in getting significant values, to make it easier to understand and interpret data. Being the analysis of interdependence between time series an important field of research, mainly as a result of advances in the characterization of dynamical systems from the signals they produce. In the medicine sphere, it is easy to find many researches that try to understand the brain behaviour, its operation mode and its internal connections. The human brain comprises approximately 1011 neurons, each of which makes about 103 synaptic connections. This huge number of connections between individual processing elements provides the fundamental substrate for neuronal ensembles to become transiently synchronized or functionally connected. A similar complex network configuration and dynamics can also be found at the macroscopic scales of systems neuroscience and brain imaging. The emergence of dynamically coupled cell assemblies represents the neurophysiological substrate for cognitive function such as perception, learning, thinking. Understanding the complex network organization of the brain on the basis of neuroimaging data represents one of the most impervious challenges for systems neuroscience. Brain connectivity is an elusive concept that refers to diferent interrelated aspects of brain organization: structural, functional connectivity (FC) and efective connectivity (EC). Structural connectivity refers to a network of physical connections linking sets of neurons, it is the anatomical structur of brain networks. However, FC refers to the statistical dependence between the signals stemming from two distinct units within a nervous system, while EC refers to the causal interactions between them. This research opens the door to try to resolve diseases related with the brain, like Parkinson’s disease, senile dementia, mild cognitive impairment, etc. One of the most important project associated with Alzheimer’s research and other diseases are enclosed in the European project called Blue Brain. The center for Biomedical Technology (CTB) of Universidad Politecnica de Madrid (UPM) forms part of the project. The CTB researches have developed a magnetoencephalography (MEG) data processing tool that allow to visualise and analyse data in an intuitive way. This tool receives the name of HERMES, and it is presented in this document. Analysis of big amount of data is a field with many years of research. It is centred in getting significant values, to make it easier to understand and interpret data. Being the analysis of interdependence between time series an important field of research, mainly as a result of advances in the characterization of dynamical systems from the signals they produce. In the medicine sphere, it is easy to find many researches that try to understand the brain behaviour, its operation mode and its internal connections. The human brain comprises approximately 1011 neurons, each of which makes about 103 synaptic connections. This huge number of connections between individual processing elements provides the fundamental substrate for neuronal ensembles to become transiently synchronized or functionally connected. A similar complex network configuration and dynamics can also be found at the macroscopic scales of systems neuroscience and brain imaging. The emergence of dynamically coupled cell assemblies represents the neurophysiological substrate for cognitive function such as perception, learning, thinking. Understanding the complex network organization of the brain on the basis of neuroimaging data represents one of the most impervious challenges for systems neuroscience. Brain connectivity is an elusive concept that refers to diferent interrelated aspects of brain organization: structural, functional connectivity (FC) and efective connectivity (EC). Structural connectivity refers to a network of physical connections linking sets of neurons, it is the anatomical structur of brain networks. However, FC refers to the statistical dependence between the signals stemming from two distinct units within a nervous system, while EC refers to the causal interactions between them. This research opens the door to try to resolve diseases related with the brain, like Parkinson’s disease, senile dementia, mild cognitive impairment, etc. One of the most important project associated with Alzheimer’s research and other diseases are enclosed in the European project called Blue Brain. The center for Biomedical Technology (CTB) of Universidad Politecnica de Madrid (UPM) forms part of the project. The CTB researches have developed a magnetoencephalography (MEG) data processing tool that allow to visualise and analyse data in an intuitive way. This tool receives the name of HERMES, and it is presented in this document.
Resumo:
La posibilidad de utilizar sistemas cuánticos para procesar y transmitir información ha impulsado la aparición de tecnologías de información cuántica, p. ej., distribución cuántica de claves. Aunque prometedoras, su uso fuera del laboratorio es actualmente demasiado costoso y complicado. En este trabajo mostramos como utilizarlas en redes ópticas de telecomunicaciones. Al utilizar una infraestructura existente y pervasiva, y compartirla con otras señales, tanto clásicas como cuánticas, el coste se reduce drásticamente y llega a un mayor público. Comenzamos integrando señales cuánticas en los tipos más utilizados de redes ópticas pasivas, por su simplicidad y alcance a usuarios finales. Luego ampliamos este estudio, proponiendo un diseño de red óptica metropolitana basado en la división en longitud de onda para multiplexar y direccionar las señales. Verificamos su funcionamiento con un prototipo. Posteriormente, estudiamos la distribución de pares de fotones entrelazados entre los usuarios de dicha red con el objetivo de abarcar más tecnologías. Para ampliar la capacidad de usuarios, rediseñamos la red troncal, cambiando tanto la topología como la tecnología utilizada en los nodos. El resultado es una red metropolitana cuántica que escala a cualquier cantidad de usuarios, a costa de una mayor complejidad y coste. Finalmente, tratamos el problema de la limitación en distancia. La solución propuesta está basada en codificación de red y permite, mediante el uso de varios caminos y nodos, modular la cantidad de información que tiene cada nodo, y así, la confianza depositada en él. ABSTRACT The potential use of quantum systems to process and transmit information has impulsed the emergence of quantum information technologies such as quantum key distribution. Despite looking promising, their use out of the laboratory is limited since they are a very delicate technology due to the need of working at the single quantum level. In this work we show how to use them in optical telecommunication networks. Using an existing infrastructure and sharing it with other signals, both quantum and conventional, reduces dramatically the cost and allows to reach a large group of users. In this work, we will first integrate quantum signals in the most common passive optical networks, for their simplicity and reach to final users. Then, we extend this study by proposing a quantum metropolitan optical network based on wavelength-division multiplexing and wavelengthaddressing, verifying its operation mode in a testbed. Later, we study the distribution of entangled photon-pairs between the users of the network with the objective of covering as much different technologies as possible. We further explore other network architectures, changing the topology and the technology used at the nodes. The resulting network scales better at the cost of a more complex and expensive infrastructure. Finally, we tackle the distance limitation problem of quantum communications. The solution offered is based on networkcoding and allows, using multiple paths and nodes, to modulate the information leaked to each node, and thus, the degree of trust placed in them.
Resumo:
Las sondas eléctricas se emplean habitualmente en la diagnosis de plasmas. La presente tesis aborda la operación de las sondas colectoras y emisoras de Langmuir en plasmas fríos de baja densidad. El estudio se ha centrado en la determinación del potencial de plasma, Vsp, mediante el potencial flotante de una sonda emisora. Esta técnica consiste en la medida del potencial de la sonda correspondiente a la condición de corriente neta igual a cero, el cual se denomina potencial flotante, VF. Este potencial se desplaza hacia el potencial del plasma según aumenta la emisión termoiónica de la sonda, hasta que se satura cerca de Vsp. Los experimentos llevados a cabo en la pluma de plasma de un motor iónico y en un plasma de descarga de glow muestran que la corriente de electrones termoiónicos es mayor que la corriente de electrones recogidos para una sonda polarizada por debajo del potencial del plasma, resultado inconsistente con la teoría tradicionalmente aceptada. Para investigar estos resultados se ha introducido el parámetro R, definido como el cociente entre la corriente de electrones emitidos y recogidos por la sonda. Este parámetro, que está relacionado con la diferencia de potencial VF - Vsp, también es útil para la descripción de los modos de operación de la sonda emisora (débil, fuerte y más allá del fuerte). Los resultados experimentales evidencian que, al contrario de lo que indica la teoría, R es mayor que la unidad. Esta discrepancia se puede solucionar introduciendo una población efectiva de electrones. Con dicha población, el nuevo modelo para la corriente total de la sonda reproduce los datos experimentales. El origen de este grupo electrónico es todavía una cuestión abierta, pero podría estar originada por una nueva estructura de potencial cerca de la sonda cuando ésta trabaja en el régimen de emisión fuerte. Para explicar dicha estructura de potencial, se propone un modelo unidimensional compuesto por un mínimo de potencial cerca de la superficie de la sonda. El análisis numérico indica que este pozo de potencial aparece para muy altas temperaturas de la sonda, reduciendo la cantidad de electrones emitidos que alcanzan el plasma y evitando así cualquier posible perturbación de éste. Los aspectos experimentales involucrados en el método del potencial flotante también se han estudiado, incluyendo cuestiones como las diferentes técnicas de obtención del VF, el cociente señal-ruido, el acoplamiento de la señal de los equipos utilizados para la obtención de las curvas I-V o la evidencia experimental de los diferentes modos de operación de la sonda. Estas evidencias empíricas se encuentran en todos los aspectos de operación de la sonda: la recolección de electrones, el potencial flotante, la precisión en las curvas I-V y la emisión electrónica. Ésta última también se estudia en la tesis, debido a que un fenómeno de super emisión tiene lugar en el régimen de emisión fuerte. En este modo de operación, las medidas experimentales indican que las corrientes termoiónicas de electrones son mayores que aquéllas predichas por la ecuación de Richardson-Dushman clásica. Por último, la diagnosis de plasmas usando sondas eléctrica bajo presencia de granos de polvo (plasmas granulares) en plasmas fríos de baja densidad también se ha estudiado, mediante la aplicación numérica de la técnica del potencial flotante de la sonda emisora en un plasma no convencional. Los resultados apuntan a que el potencial flotante de una sonda emisora se vería afectado por altas densidades de polvo o grandes partículas. ABSTRACT Electric probes are widely employed for plasma diagnostics. This dissertation concerns the operation of collecting and emissive Langmuir probes in low density cold plasmas. The study is focused on the determination of the plasma potential, Vsp, by means of the floating potential of emissive probes. This technique consists of the measurement of the probe potential, corresponding to the zero net probe current, which is the so-called floating potential, VF . This potential displaces towards the plasma potential as the thermionic electron emission increases, until it saturates near Vsp. Experiments carried out in the plasma plume of an ion thruster and in a glow discharge plasma show the thermionic electron current of the emissive Langmuir probe is higher than the collected electron current, for a probe with a bias potential below Vsp, which is inconsistent with the traditional accepted theory. To investigate these results, a parameter R is introduced as the ratio between the emitted and the collected electron current. This parameter, which is related to the difference VF - Vsp, is also useful for the description of the operation modes of the emissive Langmuir probe (weak, strong and beyond strong). The experimental results give an inconsistency of R > 1, which is solved by a modification of the theory for emissive probes, with the introduction of an effective electron population. With this new electron group, the new model for the total probe current agrees with the experimental data. The origin of this electron group remains an open question, but it might be originated by a new potential structure near the emissive probe when it operates in the strong emission regime. A simple one-dimension model composed by a minimum of potential near the probe surface is discussed for strongly emitting emissive probes. The results indicate that this complex potential structure appears for very high probe temperatures and the potential well might reduce the emitted electrons population reaching the plasma bulk. The experimental issues involved in the floating potential method are also studied, as the different obtaining techniques of VF, the signal-to-noise ratio, the signal coupling of the I-V curve measurement system or the experimental evidence of the probe operation modes. These empirical proofs concern all the probe operation aspects: the electron collection, the floating potential, the I-V curve accuracy as well as the electron emission. This last issue is also investigated in this dissertation, because a super emission takes place in the strong emission regime. In this operation mode, the experimental results indicate that the thermionic electron currents might be higher than those predicted by the classical Richardson-Dushman equation. Finally, plasma diagnosis using electric probes in the presence of dust grains (dusty plasmas) in low density cold plasmas is also addressed. The application of the floating potential technique of the emissive probe in a non-conventional complex plasma is numerically investigated, whose results point out the floating potential of the emissive probe might be shifted for high dust density or large dust particles.
Resumo:
Rms voltage regulation may be an attractive possibility for controlling power inverters. Combined with a Hall Effect sensor for current control, it keeps its parallel operation capability while increasing its noise immunity, which may lead to a reduction of the Total Harmonic Distortion (THD). Besides, as voltage regulation is designed in DC, a simple PI regulator can provide accurate voltage tracking. Nevertheless, this approach does not lack drawbacks. Its narrow voltage bandwidth makes transients last longer and it increases the voltage THD when feeding non-linear loads, such as rectifying stages. On the other hand, the implementation can fall into offset voltage error. Furthermore, the information of the output voltage phase is hidden for the control as well, making the synchronization of a 3-phase setup not trivial. This paper explains the concept, design and implementation of the whole control scheme, in an on board inverter able to run in parallel and within a 3-phase setup. Special attention is paid to solve the problems foreseen at implementation level: a third analog loop accounts for the offset level is added and a digital algorithm guarantees 3-phase voltage synchronization.
Resumo:
El diagnóstico y detección temprana de enfermedades son clave para reducir la tasa de mortalidad, las hospitalizaciones de larga duración y el desaprovechamiento de recursos. En los últimos años se ha impulsado, mediante un aumento de la financiación, el desarrollo de nuevos biosensores de bajo coste capaces de detectar y cuantificar cantidades muy pequeñas de especies biológicas de una forma barata y sencilla. El trabajo presentado en esta Tesis Doctoral describe la investigación llevada a cabo en el desarrollo de sensores gravimétricos basados en resonadores de ondas acústicas de volumen (BAW) de estructura maciza (SMR). Los dispositivos emplean películas delgadas de A1N como material piezoeléctrico y operan en modo de cizalladura, para así poder detectar especies biológicas en medio líquido. El principio de funcionamiento de estos sensores se basa en la variación que experimenta la frecuencia de resonancia al quedar una pequeña masa adherida a su superficie. Necesitan operar en modo de cizalladura para que su resonancia no se atenúe al trabajar en medio líquido, así como ofrecer una superficie capaz de ser funcionalizada específicamente para la especie biológica a detectar. El reto planteado en esta tesis requiere un acercamiento pluridisciplinar al problema que incluye el estudio de los diferentes materiales que constituyen la estructura multicapa que forma un SMR, el diseño y fabricación del dispositivo y del sistema de fluídica, la funcionalización bioquímica de la superficie del sensor, la demostración de la capacidad de detección de especies biológicas y finalmente el diseño y fabricación de la electrónica asociada para la detección de la señal eléctrica. Todas esas tareas han sido abordadas en las distintas etapas del desarrollo de esta tesis y las contribuciones más relevantes se describen en el documento. En el campo de desarrollo de los materiales, se propone un proceso en dos etapas para la pulverización reactiva de capas de A1N que contengan microcristales inclinados capaces de excitar el modo de cizalladura. Se caracteriza la velocidad acústica del modo de cizalladura en todos los materiales que componen la estructura, con el fin de poder obtener un diseño más adecuado del reflector acústico. Se propone un nuevo tipo de material aislante de alta impedancia acústica consistente en capas de W03 pulverizadas que presenta ciertas ventajas tecnológicas frente a las capas convencionales de Ta205. Respecto del diseño del transductor, se estudia la influencia que tienen los con tactos eléctricos extendidos del resonador necesarios para poder adaptar el sistema de fluídica a la estructura. Los resultados indican que es necesario trabajar sobre sustratos aislantes (tanto el soporte como el espejo acústico) para evitar efectos parásitos asociados al uso de capas metálicas bajo los electrodos del resonador que dañan su resonancia. Se analiza la influencia de las diferentes capas del dispositivo en el coeficiente de temperatura de la frecuencia (TCF) del resonador llegando a la conclusión de que las dos últimas capas del reflector acústico afectan significativamente al TCF del SMR, pudiendo reducirse ajusfando adecuadamente sus espesores. De acuerdo con los resultados de estos estudios, se han diseñado finalmente resonadores SMR operando a f .3 GHz en modo de cizalladura, con un área activa de 65000 /xm2, contactos eléctricos que se extienden f .7 mm y factores de calidad en líquido de f 50. Las extensiones eléctricas permiten adaptar el resonador a un sistema de fluídica de metacrilato. Para la detección de especies biológicas se realiza un montaje experimental que permite circular 800 ¡A por la superficie del sensor a través de un circuito cerrado que trabaja a volumen constante. La circulación de soluciones iónicas sobre el sensor descubierto pone de manifiesto que las altas frecuencias de operación previenen los cortocircuitos y por tanto el aislamiento de los electrodos es prescindible. Se desarrolla un protocolo ad-hoc de funcionalización basado en el proceso estándar APTESGlutaraldehído. Se proponen dos alternativas novedosas para la funcionalización de las áreas activas del sensor basadas en el uso de capas de oxidación de Ir02 y su activación a través de un plasma de oxígeno que no daña al dispositivo. Ambos procesos contribuyen a simplificar notablemente la funcionalización de los sensores gravimétricos. Se utilizan anticuerpos y aptámeros como receptores para detectar trombina, anticuerpo monoclonal IgG de ratón y bacteria sonicadas. Una calibración preliminar del sensor con depósitos de capas finas de Si02 de densidad y espesor conocidos permite obtener una sensibilidad de 1800 kHz/pg-cm2 y un límite de detección of 4.2 pg. Finalmente se propone el prototipo de un circuito electrónico de excitación y lectura de bajo coste diseñado empleando teoría de circuitos de microondas. Aunque su diseño y funcionamiento admite mejoras, constituye la última etapa de un sistema completo de bajo coste para el diagnóstico de especies biológicas basado en resonadores SMR de A1N. ABSTRACT Early diagnosis and detection of diseases are essential for reducing mortality rate and preventing long-term hospitalization and waste of resources. These requirements have boosted the efforts and funding on the research of accurate and reliable means for detection and quantification of biological species, also known as biosensors. The work presented in this thesis describes the development and fabrication of gravimetric biosensors based on piezoelectric AlN bulk acoustic wave (BAW) solidly mounted resonators (SMRs) for detection of biological species in liquid media. These type of devices base their sensing principles in the variation that their resonant frequency suffers when a mass is attached to their surface. They need to operate in the shear mode to maintain a strong resonance in liquid and an adequate functionalisation of their sensing area to guarantee that only the targeted molecules cause the shift. The challenges that need to be overcome to achieve piezoelectric BAW resonators for high sensitivity detection in fluids require a multidisciplinary approach, that include the study of the materials involved, the design of the device and the fluidic system, the biochemical functionalisation of the active area, the experimental proof-of-concept with different target species and the design of an electronic readout circuit. All this tasks have been tackled at different stages of the thesis and the relevant contributions are described in the document. In the field of materials, a two-stage sputtering deposition process has been developed to obtain good-quality AlN films with uniformly tilted grains required to excite the shear mode. The shear acoustic velocities of the materials composing the acoustic reflector have been accurately studied to ensure an optimum design of the reflector stack. WO3 sputtered films have been proposed as high acoustic impedance material for insulating acoustic reflectors. They display several technological advantages for the processing of the resonators. Regarding the design, a study of the influence of the electrical extensions necessary to fit a fluidic system on the performance of the devices has been performed. The results indicate that high resistivity substrates and insulating reflectors are necessary to avoid the hindering of the resonance due to the parasitic effects induced by the extensions. The influence of the different layers of the stack on the resultant TCF of the SMRs has also been investigated. The two layers of the reflector closer to the piezoelectric layer have a significant influence on the TCF, which can be reduced by modifying their thicknesses accordingly. The data provided by these studies has led to the final design of the devices, which operate at 1.3 GHz in the shear mode and display an active area of 65000 /xm2 and electrical extensions of 1.7 mm while keeping a Qahear=150 in liquid. The extensions enable to fit a custom-made fluidic system made of methacrylate. To perform the biosensing experiments, an experimental setup with a liquid closed circuit operating at constant flow has been developed. Buffers of ionic characteristics have been tested on non-isolated devices, revealing that high operation frequencies prevent the risk of short circuit. An ad-hoc functionalisation protocol based on the standard APTES - Glutaraldehyde process has been developed. It includes two new processes that simplify the fabrication of the transducers: the use of IrO2 as oxidation layer and its functionalisation through an O2 plasma treatment that does not damage the resonators. Both antibodies and aptamers are used as receptors. In liquid sensing proof-of-concept experiments with thrombin, IgG mouse monoclonal antibody and sonicated bacteria have been displayed. A preliminary calibration of the devices using SiO2 layers reveals a sensitivity of 1800 kHz/pg-cm2 and a limit of detection of 4.2 pg. Finally, a first prototype of a low-cost electronic readout circuit designed using a standard microwave approach has been developed. Although its performance can be significantly improved, it is an effective first approach to the final stage of a portable low-cost diagnostic system based on shear mode AlN SMRs.
Resumo:
A procedure for measuring the overheating temperature (ΔT ) of a p-n junction area in the structure of photovoltaic (PV) cells converting laser or solar radiations relative to the ambient temperature has been proposed for the conditions of connecting to an electric load. The basis of the procedure is the measurement of the open-circuit voltage (VO C ) during the initial time period after the fast disconnection of the external resistive load. The simultaneous temperature control on an external heated part of a PV module gives the means for determining the value of VO C at ambient temperature. Comparing it with that measured after switching OFF the load makes the calculation of ΔT possible. Calibration data on the VO C = f(T ) dependences for single-junction AlGaAs/GaAs and triple-junction InGaP/GaAs/Ge PV cells are presented. The temperature dynamics in the PV cells has been determined under flash illumination and during fast commutation of the load. Temperature measurements were taken in two cases: converting continuous laser power by single-junction cells and converting solar power by triple-junction cells operating in the concentrator modules.
Resumo:
We have studied the thermo-mechanical response and atomistic degradation of final lenses in HiPER project. Final silica lenses are squares of 75 × 75 cm2 with a thickness of 5 cm. There are two scenarios where lenses are located at 8 m from the centre: •HiPER 4a, bunches of 100 shots (maximum 5 DT shots <48 MJ at ≈0.1 Hz). No blanket in chamber geometry. •HiPER 4b, continuous mode with shots ≈50 MJ at 10 Hz to generate 0.5 GW. Liquid metal blanket in chamber design.
Resumo:
The main objective of this work is the design and implementation of the digital control stage of a 280W AC/DC industrial power supply in a single low-cost microcontroller to replace the analog control stage. The switch-mode power supply (SMPS) consists of a PFC boost converter with fixed frequency operation and a variable frequency LLC series resonant DC/DC converter. Input voltage range is 85VRMS-550VRMS and the output voltage range is 24V-28V. A digital controller is especially suitable for this kind of SMPS to implement its multiple functionalities and to keep the efficiency and the performance high over the wide range of input voltages. Additional advantages of the digital control are reliability and size. The optimized design and implementation of the digital control stage it is presented. Experimental results show the stable operation of the controlled system and an estimation of the cost reduction achieved with the digital control stage.