24 resultados para infrared thermal imaging
em Universidad Politécnica de Madrid
Resumo:
Measuring skin temperature (TSK) provides important information about the complex thermal control system and could be interesting when carrying out studies about thermoregulation. The most common method to record TSK involves thermocouples at specific locations; however, the use of infrared thermal imaging (IRT) has increased. The two methods use different physical processes to measure TSK, and each has advantages and disadvantages. Therefore, the objective of this study was to compare the mean skin temperature (MTSK) measurements using thermocouples and IRT in three different situations: pre-exercise, exercise and post-exercise. Analysis of the residual scores in Bland-Altman plots showed poor agreement between the MTSK obtained using thermocouples and those using IRT. The averaged error was -0.75 °C during pre-exercise, 1.22 °C during exercise and -1.16 °C during post-exercise, and the reliability between the methods was low in the pre- (ICC = 0.75 [0.12 to 0.93]), during (ICC = 0.49 [-0.80 to 0.85]) and post-exercise (ICC = 0.35 [-1.22 to 0.81] conditions. Thus, there is poor correlation between the values of MTSK measured by thermocouples and IRT pre-exercise, exercise and post-exercise, and low reliability between the two forms of measurement.
Resumo:
The use of a common environment for processing different powder foods in the industry has increased the risk of finding peanut traces in powder foods. The analytical methods commonly used for detection of peanut such as enzyme-linked immunosorbent assay (ELISA) and real-time polymerase chain reaction (RT-PCR) represent high specificity and sensitivity but are destructive and time-consuming, and require highly skilled experimenters. The feasibility of NIR hyperspectral imaging (HSI) is studied for the detection of peanut traces down to 0.01% by weight. A principal-component analysis (PCA) was carried out on a dataset of peanut and flour spectra. The obtained loadings were applied to the HSI images of adulterated wheat flour samples with peanut traces. As a result, HSI images were reduced to score images with enhanced contrast between peanut and flour particles. Finally, a threshold was fixed in score images to obtain a binary classification image, and the percentage of peanut adulteration was compared with the percentage of pixels identified as peanut particles. This study allowed the detection of traces of peanut down to 0.01% and quantification of peanut adulteration from 10% to 0.1% with a coefficient of determination (r2) of 0.946. These results show the feasibility of using HSI systems for the detection of peanut traces in conjunction with chemical procedures, such as RT-PCR and ELISA to facilitate enhanced quality-control surveillance on food-product processing lines.
Resumo:
The scientific objectives, design, and implementation of the Optical, Spectroscopic, and Infrared Remote Imaging System (OSIRIS) for the International Rosetta Mission are described. The instrument comprises two camera systems with a common electronics box. A narrow angle camera will provide high resolution images of the structure and morphology of the nucleus of a comet. A wide angle camera with high straylight rejection and dynamic range will be used to investigate the innermost coma and the emission process at the surface of the comet. An infrared imaging system, which dramatically enhances the scientific return has been included in the narrow angle camera at little extra cost.
Resumo:
From the last decades, infrared thermography is quite often associated with things other than clinical medicine. For example, the chemical, automobile, aeronautic industries and civil engineering. However, thermography is where infrared images of the breast are analyzed by board certified thermographers and an abnormal thermogram is reported as the significant risk for the existence of breast tumor (Ng, 2009). Thermography is a painless, noninvasive, no radiation, as well as being cheaper and faster, easier access. The aim of this review was to identify the views of clinicians on the use of thermography for quantifying the risk of breast cancer. We used articles published recently in a reliable database. Thermography has been convicted over the years; it has been labeled by subjective interpretation. Most of the reviewed articles agree that mammography is currently the main examination chosen by doctors for the screening of breast cancer (Acharya et al., 2010; Kennedy et al., 2009). However, several studies have reported promising results for the technique (Wang et al., 2010). Additionally, some authors suggest that thermography is complementary to other diagnostic methods, and that the best strategy for the early detection of breast cancer would be to use them together (Kennedy et al., 2009; Hersh, 2004). The combination of thermal imaging with other tests would increase accuracy, sensitivity and specificity of the evaluation and allow a better quantification of the risk of breast cancer.
Resumo:
La termografía es un método de inspección y diagnóstico basado en la radiación infrarroja que emiten los cuerpos. Permite medir dicha radiación a distancia y sin contacto, obteniendo un termograma o imagen termográfica, objeto de estudio de este proyecto. Todos los cuerpos que se encuentren a una cierta temperatura emiten radiación infrarroja. Sin embargo, para hacer una inspección termográfica hay que tener en cuenta la emisividad de los cuerpos, capacidad que tienen de emitir radiación, ya que ésta no sólo depende de la temperatura del cuerpo, sino también de sus características superficiales. Las herramientas necesarias para conseguir un termograma son principalmente una cámara termográfica y un software que permita su análisis. La cámara percibe la emisión infrarroja de un objeto y lo convierte en una imagen visible, originalmente monocromática. Sin embargo, después es coloreada por la propia cámara o por un software para una interpretación más fácil del termograma. Para obtener estas imágenes termográficas existen varias técnicas, que se diferencian en cómo la energía calorífica se transfiere al cuerpo. Estas técnicas se clasifican en termografía pasiva, activa y vibrotermografía. El método que se utiliza en cada caso depende de las características térmicas del cuerpo, del tipo de defecto a localizar o la resolución espacial de las imágenes, entre otros factores. Para analizar las imágenes y así obtener diagnósticos y detectar defectos, es importante la precisión. Por ello existe un procesado de las imágenes, para minimizar los efectos provocados por causas externas, mejorar la calidad de la imagen y extraer información de las inspecciones realizadas. La termografía es un método de ensayo no destructivo muy flexible y que ofrece muchas ventajas. Por esta razón el campo de aplicación es muy amplio, abarcando desde aplicaciones industriales hasta investigación y desarrollo. Vigilancia y seguridad, ahorro energético, medicina o medio ambiente, son algunos de los campos donde la termografía aportaimportantes beneficios. Este proyecto es un estudio teórico de la termografía, donde se describen detalladamente cada uno de los aspectos mencionados. Concluye con una aplicación práctica, creando una cámara infrarroja a partir de una webcam, y realizando un análisis de las imágenes obtenidas con ella. Con esto se demuestran algunas de las teorías explicadas, así como la posibilidad de reconocer objetos mediante la termografía. Thermography is a method of testing and diagnosis based on the infrared radiation emitted by bodies. It allows to measure this radiation from a distance and with no contact, getting a thermogram or thermal image, object of study of this project. All bodies that are at a certain temperature emit infrared radiation. However, making a thermographic inspection must take into account the emissivity of the body, capability of emitting radiation. This not only depends on the temperature of the body, but also on its surface characteristics. The tools needed to get a thermogram are mainly a thermal imaging camera and software that allows analysis. The camera sees the infrared emission of an object and converts it into a visible image, originally monochrome. However, after it is colored by the camera or software for easier interpretation of thermogram. To obtain these thermal images it exists various techniques, which differ in how heat energy is transferred to the body. These techniques are classified into passive thermography, active and vibrotermografy. The method used in each case depends on the thermal characteristics of the body, the type of defect to locate or spatial resolution of images, among other factors. To analyze the images and obtain diagnoses and defects, accuracy is important. Thus there is a image processing to minimize the effects caused by external causes, improving image quality and extract information from inspections. Thermography is a non-‐destructive test method very flexible and offers many advantages. So the scope is very wide, ranging from industrial applications to research and development.Surveillance and security, energy saving, environmental or medicine are some of the areas where thermography provides significant benefits. This project is a theoretical study of thermography, which describes in detail each of these aspects. It concludes with a practical application, creating an infrared camera from a webcam, and making an analysis of the images obtained with it. This will demonstrate some of the theories explained as well as the ability to recognize objects by thermography.
Resumo:
Thermal imaging has been used to evaluate the response to drought and warm temperatures in a collection of Brachypodium distachyon lines adapted to varied environmental conditions. Thermographic records were able to separate lines from contrasting rainfall regimes. Genotypes from dryer environments showed warmer leaves under water deficit, which suggested that decreased evapotranspiration was related to a more intense stomatal closure. When irrigated and under high temperature conditions, drought-adapted lines showed cooler leaves than lines from wetter zones. The consistent, inverse thermographic response of lines to water stress and heat validates the reliability of this method to assess drought tolerance in this model cereal. It additionally supports the hypothesis that stomatal-based mechanisms are involved in natural variation for drought tolerance in Brachypodium. The study further suggests that these mechanisms are not constitutive but likely related to a more efficient closing response to avoid dehydration in adapted genotypes. Higher leaf temperature under water deficit seems a dependable criterion of drought tolerance, not only in B. distachyon but also in the main cereal crops and related grasses where thermography can facilitate high-throughput preliminary screening of tolerant materials.
Resumo:
This paper presents different test alternatives which can be used on-site in a PV installation to detect potential induced degradation (PID) in modules. The testing procedures proposed are: thermal imaging; electroluminescence imaging; open circuit voltage measurements; operating voltage measurements; IV curve measurements; and dark IV curve measurements. Advantages and disadvantages of each test are reported.
Resumo:
The Optical, Spectroscopic, and Infrared Remote Imaging System OSIRIS is the scientific camera system onboard the Rosetta spacecraft (Figure 1). The advanced high performance imaging system will be pivotal for the success of the Rosetta mission. OSIRIS will detect 67P/Churyumov-Gerasimenko from a distance of more than 106 km, characterise the comet shape and volume, its rotational state and find a suitable landing spot for Philae, the Rosetta lander. OSIRIS will observe the nucleus, its activity and surroundings down to a scale of ~2 cm px−1. The observations will begin well before the onset of cometary activity and will extend over months until the comet reaches perihelion. During the rendezvous episode of the Rosetta mission, OSIRIS will provide key information about the nature of cometary nuclei and reveal the physics of cometary activity that leads to the gas and dust coma. OSIRIS comprises a high resolution Narrow Angle Camera (NAC) unit and a Wide Angle Camera (WAC) unit accompanied by three electronics boxes. The NAC is designed to obtain high resolution images of the surface of comet 7P/Churyumov-Gerasimenko through 12 discrete filters over the wavelength range 250–1000 nm at an angular resolution of 18.6 μrad px−1. The WAC is optimised to provide images of the near-nucleus environment in 14 discrete filters at an angular resolution of 101 μrad px−1. The two units use identical shutter, filter wheel, front door, and detector systems. They are operated by a common Data Processing Unit. The OSIRIS instrument has a total mass of 35 kg and is provided by institutes from six European countries
Resumo:
Quantum dot infrared photodetectors (QDIPs) are very attractive for many applications such as infrared imaging, remote sensing and gas sensing, thanks to its promising features such as high temperature operation, normal incidence response and low dark current [1]. However, the key issue is to obtain a high-quality active region which requires an optimization of the nanostructure. By using GaAsSb capping layer, InAs QDs have improved their optical emission in the range between 1.15 and 1.3 m (at Sb composition of 14 %), due to a reduction of a compressive strain in QD and an increment of a QD height [2]. In this work, we have demonstrated strong and narrow intraband photoresponses at ~ 5 m from GaAsSb-capped InAs/GaAs QDIPs under normal light-incidence.
Resumo:
The Bioinstrumentation Laboratory belongs to the Centre for Biomedical Technology (CTB) of the Technical University of Madrid and its main objective is to provide the scientific community with devices and techniques for the characterization of micro and nanostructures and consequently finding their best biomedical applications. Hyperthermia (greek word for “overheating”) is defined as the phenomenon that occurs when a body is exposed to an energy generating source that can produce a rise in temperature (42-45ºC) for a given time [1]. Specifically, the aim of the hyperthermia methods used in The Bioinstrumentation Laboratory is the development of thermal therapies, some of these using different kinds of nanoparticles, to kill cancer cells and reduce the damage on healthy tissues. The optical hyperthermia is based on noble metal nanoparticles and laser irradiation. This kind of nanoparticles has an immense potential associated to the development of therapies for cancer on account of their Surface Plasmon Resonance (SPR) enhanced light scattering and absorption. In a short period of time, the absorbed light is converted into localized heat, so we can take advantage of these characteristics to heat up tumor cells in order to obtain the cellular death [2]. In this case, the laboratory has an optical hyperthermia device based on a continuous wave laser used to kill glioblastoma cell lines (1321N1) in the presence of gold nanorods (Figure 1a). The wavelength of the laser light is 808 nm because the penetration of the light in the tissue is deeper in the Near Infrared Region. The first optical hyperthermia results show that the laser irradiation produces cellular death in the experimental samples of glioblastoma cell lines using gold nanorods but is not able to decrease the cellular viability of cancer cells in samples without the suitable nanorods (Figure 1b) [3]. The generation of magnetic hyperthermia is performed through changes of the magnetic induction in magnetic nanoparticles (MNPs) that are embedded in viscous medium. The Figure 2 shows a schematic design of the AC induction hyperthermia device in magnetic fluids. The equipment has been manufactured at The Bioinstrumentation Laboratory. The first block implies two steps: the signal selection with frequency manipulation option from 9 KHz to 2MHz, and a linear output up to 1500W. The second block is where magnetic field is generated ( 5mm, 10 turns). Finally, the third block is a software control where the user can establish initial parameters, and also shows the temperature response of MNPs due to the magnetic field applied [4-8]. The Bioinstrumentation Laboratory in collaboration with the Mexican company MRI-DT have recently implemented a new research line on Nuclear Magnetic Resonance Hyperthermia, which is sustained on the patent US 7,423,429B2 owned by this company. This investigation is based on the use of clinical MRI equipment not only for diagnosis but for therapy [9]. This idea consists of two main facts: Magnetic Resonance Imaging can cause focal heating [10], and the differentiation in resonant frequency between healthy and cancer cells [11]. To produce only heating in cancer cells when the whole body is irradiated, it is necessary to determine the specific resonant frequency of the target, using the information contained in the spectra of the area of interest. Then, special RF pulse sequence is applied to produce fast excitation and relaxation mechanism that generates temperature increase of the tumor, causing cellular death or metabolism malfunction that stops cellular division
Resumo:
Infrared thermography IR is a technique, which allows us to get rapidly and non-invasive thermal images from objects or human beings. (Barnes, 1967). In Medicine, its usefulness as diagnosis tool was accepted decades ago (BenEliyahu, 1990), but other techniques with a higher efficiency -such as magnetic resonance or x-rays- ousted it. Nevertheless, the technological improvements on thermographic cameras and new studies on sport injuries are reinforcing new applications (Ring, 2006)
Resumo:
Thermal response of skin temperature (Tsk) has been studied during exercise and immediately after (Merla, 2010). However, more studies about the influence of exercise on Tsk through the time are required to understand the impact of physical activity on thermoregulatory system and metabolism
Resumo:
La termografía infrarroja (TI) es una técnica no invasiva y de bajo coste que permite, con el simple acto de tomar una fotografía, el registro sin contacto de la energía que irradia el cuerpo humano (Akimov & Son’kin, 2011, Merla et al., 2005, Ng et al., 2009, Costello et al., 2012, Hildebrandt et al., 2010). Esta técnica comenzó a utilizarse en el ámbito médico en los años 60, pero debido a los malos resultados como herramienta diagnóstica y la falta de protocolos estandarizados (Head & Elliot, 2002), ésta se dejó de utilizar en detrimento de otras técnicas más precisas a nivel diagnóstico. No obstante, las mejoras tecnológicas de la TI en los últimos años han hecho posible un resurgimiento de la misma (Jiang et al., 2005, Vainer et al., 2005, Cheng et al., 2009, Spalding et al., 2011, Skala et al., 2012), abriendo el camino a nuevas aplicaciones no sólo centradas en el uso diagnóstico. Entre las nuevas aplicaciones, destacamos las que se desarrollan en el ámbito de la actividad física y el deporte, donde recientemente se ha demostrado que los nuevos avances con imágenes de alta resolución pueden proporcionar información muy interesante sobre el complejo sistema de termorregulación humana (Hildebrandt et al., 2010). Entre las nuevas aplicaciones destacan: la cuantificación de la asimilación de la carga de trabajo físico (Čoh & Širok, 2007), la valoración de la condición física (Chudecka et al., 2010, 2012, Akimov et al., 2009, 2011, Merla et al., 2010), la prevención y seguimiento de lesiones (Hildebrandt et al., 2010, 2012, Badža et al., 2012, Gómez Carmona, 2012) e incluso la detección de agujetas (Al-Nakhli et al., 2012). Bajo estas circunstancias, se acusa cada vez más la necesidad de ampliar el conocimiento sobre los factores que influyen en la aplicación de la TI en los seres humanos, así como la descripción de la respuesta de la temperatura de la piel (TP) en condiciones normales, y bajo la influencia de los diferentes tipos de ejercicio. Por consiguiente, este estudio presenta en una primera parte una revisión bibliográfica sobre los factores que afectan al uso de la TI en los seres humanos y una propuesta de clasificación de los mismos. Hemos analizado la fiabilidad del software Termotracker, así como su reproducibilidad de la temperatura de la piel en sujetos jóvenes, sanos y con normopeso. Finalmente, se analizó la respuesta térmica de la piel antes de un entrenamiento de resistencia, velocidad y fuerza, inmediatamente después y durante un período de recuperación de 8 horas. En cuanto a la revisión bibliográfica, hemos propuesto una clasificación para organizar los factores en tres grupos principales: los factores ambientales, individuales y técnicos. El análisis y descripción de estas influencias deben representar la base de nuevas investigaciones con el fin de utilizar la TI en las mejores condiciones. En cuanto a la reproducibilidad, los resultados mostraron valores excelentes para imágenes consecutivas, aunque la reproducibilidad de la TP disminuyó ligeramente con imágenes separadas por 24 horas, sobre todo en las zonas con valores más fríos (es decir, zonas distales y articulaciones). Las asimetrías térmicas (que normalmente se utilizan para seguir la evolución de zonas sobrecargadas o lesionadas) también mostraron excelentes resultados pero, en este caso, con mejores valores para las articulaciones y el zonas centrales (es decir, rodillas, tobillos, dorsales y pectorales) que las Zonas de Interés (ZDI) con valores medios más calientes (como los muslos e isquiotibiales). Los resultados de fiabilidad del software Termotracker fueron excelentes en todas las condiciones y parámetros. En el caso del estudio sobre los efectos de los entrenamientos de la velocidad resistencia y fuerza en la TP, los resultados muestran respuestas específicas según el tipo de entrenamiento, zona de interés, el momento de la evaluación y la función de las zonas analizadas. Los resultados mostraron que la mayoría de las ZDI musculares se mantuvieron significativamente más calientes 8 horas después del entrenamiento, lo que indica que el efecto del ejercicio sobre la TP perdura por lo menos 8 horas en la mayoría de zonas analizadas. La TI podría ser útil para cuantificar la asimilación y recuperación física después de una carga física de trabajo. Estos resultados podrían ser muy útiles para entender mejor el complejo sistema de termorregulación humano, y por lo tanto, para utilizar la TI de una manera más objetiva, precisa y profesional con visos a mejorar las nuevas aplicaciones termográficas en el sector de la actividad física y el deporte Infrared Thermography (IRT) is a safe, non-invasive and low-cost technique that allows the rapid and non-contact recording of the irradiated energy released from the body (Akimov & Son’kin, 2011; Merla et al., 2005; Ng et al., 2009; Costello et al., 2012; Hildebrandt et al., 2010). It has been used since the early 1960’s, but due to poor results as diagnostic tool and a lack of methodological standards and quality assurance (Head et al., 2002), it was rejected from the medical field. Nevertheless, the technological improvements of IRT in the last years have made possible a resurgence of this technique (Jiang et al., 2005; Vainer et al., 2005; Cheng et al., 2009; Spalding et al., 2011; Skala et al., 2012), paving the way to new applications not only focused on the diagnose usages. Among the new applications, we highlighted those in physical activity and sport fields, where it has been recently proven that a high resolution thermal images can provide us with interesting information about the complex thermoregulation system of the body (Hildebrandt et al., 2010), information than can be used as: training workload quantification (Čoh & Širok, 2007), fitness and performance conditions (Chudecka et al., 2010, 2012; Akimov et al., 2009, 2011; Merla et al., 2010; Arfaoui et al., 2012), prevention and monitoring of injuries (Hildebrandt et al., 2010, 2012; Badža et al., 2012, Gómez Carmona, 2012) and even detection of Delayed Onset Muscle Soreness – DOMS- (Al-Nakhli et al., 2012). Under this context, there is a relevant necessity to broaden the knowledge about factors influencing the application of IRT on humans, and to better explore and describe the thermal response of Skin Temperature (Tsk) in normal conditions, and under the influence of different types of exercise. Consequently, this study presents a literature review about factors affecting the application of IRT on human beings and a classification proposal about them. We analysed the reliability of the software Termotracker®, and also its reproducibility of Tsk on young, healthy and normal weight subjects. Finally, we examined the Tsk thermal response before an endurance, speed and strength training, immediately after and during an 8-hour recovery period. Concerning the literature review, we proposed a classification to organise the factors into three main groups: environmental, individual and technical factors. Thus, better exploring and describing these influence factors should represent the basis of further investigations in order to use IRT in the best and optimal conditions to improve its accuracy and results. Regarding the reproducibility results, the outcomes showed excellent values for consecutive images, but the reproducibility of Tsk slightly decreased with time, above all in the colder Regions of Interest (ROI) (i.e. distal and joint areas). The side-to-side differences (ΔT) (normally used to follow the evolution of some injured or overloaded ROI) also showed highly accurate results, but in this case with better values for joints and central ROI (i.e. Knee, Ankles, Dorsal and Pectoral) than the hottest muscle ROI (as Thigh or Hamstrings). The reliability results of the IRT software Termotracker® were excellent in all conditions and parameters. In the part of the study about the effects on Tsk of aerobic, speed and strength training, the results of Tsk demonstrated specific responses depending on the type of training, ROI, moment of the assessment and the function of the considered ROI. The results showed that most of muscular ROI maintained warmer significant Tsk 8 hours after the training, indicating that the effect of exercise on Tsk last at least 8 hours in most of ROI, as well as IRT could help to quantify the recovery status of the athlete as workload assimilation indicator. Those results could be very useful to better understand the complex skin thermoregulation behaviour, and therefore, to use IRT in a more objective, accurate and professional way to improve the new IRT applications for the physical activity and sport sector.
Resumo:
El objeto de esta Tesis doctoral es el desarrollo de una metodologia para la deteccion automatica de anomalias a partir de datos hiperespectrales o espectrometria de imagen, y su cartografiado bajo diferentes condiciones tipologicas de superficie y terreno. La tecnologia hiperespectral o espectrometria de imagen ofrece la posibilidad potencial de caracterizar con precision el estado de los materiales que conforman las diversas superficies en base a su respuesta espectral. Este estado suele ser variable, mientras que las observaciones se producen en un numero limitado y para determinadas condiciones de iluminacion. Al aumentar el numero de bandas espectrales aumenta tambien el numero de muestras necesarias para definir espectralmente las clases en lo que se conoce como Maldicion de la Dimensionalidad o Efecto Hughes (Bellman, 1957), muestras habitualmente no disponibles y costosas de obtener, no hay mas que pensar en lo que ello implica en la Exploracion Planetaria. Bajo la definicion de anomalia en su sentido espectral como la respuesta significativamente diferente de un pixel de imagen respecto de su entorno, el objeto central abordado en la Tesis estriba primero en como reducir la dimensionalidad de la informacion en los datos hiperespectrales, discriminando la mas significativa para la deteccion de respuestas anomalas, y segundo, en establecer la relacion entre anomalias espectrales detectadas y lo que hemos denominado anomalias informacionales, es decir, anomalias que aportan algun tipo de informacion real de las superficies o materiales que las producen. En la deteccion de respuestas anomalas se asume un no conocimiento previo de los objetivos, de tal manera que los pixeles se separan automaticamente en funcion de su informacion espectral significativamente diferenciada respecto de un fondo que se estima, bien de manera global para toda la escena, bien localmente por segmentacion de la imagen. La metodologia desarrollada se ha centrado en la implicacion de la definicion estadistica del fondo espectral, proponiendo un nuevo enfoque que permite discriminar anomalias respecto fondos segmentados en diferentes grupos de longitudes de onda del espectro, explotando la potencialidad de separacion entre el espectro electromagnetico reflectivo y emisivo. Se ha estudiado la eficiencia de los principales algoritmos de deteccion de anomalias, contrastando los resultados del algoritmo RX (Reed and Xiaoli, 1990) adoptado como estandar por la comunidad cientifica, con el metodo UTD (Uniform Targets Detector), su variante RXD-UTD, metodos basados en subespacios SSRX (Subspace RX) y metodo basados en proyecciones de subespacios de imagen, como OSPRX (Orthogonal Subspace Projection RX) y PP (Projection Pursuit). Se ha desarrollado un nuevo metodo, evaluado y contrastado por los anteriores, que supone una variacion de PP y describe el fondo espectral mediante el analisis discriminante de bandas del espectro electromagnetico, separando las anomalias con el algortimo denominado Detector de Anomalias de Fondo Termico o DAFT aplicable a sensores que registran datos en el espectro emisivo. Se han evaluado los diferentes metodos de deteccion de anomalias en rangos del espectro electromagnetico del visible e infrarrojo cercano (Visible and Near Infrared-VNIR), infrarrojo de onda corta (Short Wavelenght Infrared-SWIR), infrarrojo medio (Meadle Infrared-MIR) e infrarrojo termico (Thermal Infrared-TIR). La respuesta de las superficies en las distintas longitudes de onda del espectro electromagnetico junto con su entorno, influyen en el tipo y frecuencia de las anomalias espectrales que puedan provocar. Es por ello que se han utilizado en la investigacion cubos de datos hiperepectrales procedentes de los sensores aeroportados cuya estrategia y diseno en la construccion espectrometrica de la imagen difiere. Se han evaluado conjuntos de datos de test de los sensores AHS (Airborne Hyperspectral System), HyMAP Imaging Spectrometer, CASI (Compact Airborne Spectrographic Imager), AVIRIS (Airborne Visible Infrared Imaging Spectrometer), HYDICE (Hyperspectral Digital Imagery Collection Experiment) y MASTER (MODIS/ASTER Simulator). Se han disenado experimentos sobre ambitos naturales, urbanos y semiurbanos de diferente complejidad. Se ha evaluado el comportamiento de los diferentes detectores de anomalias a traves de 23 tests correspondientes a 15 areas de estudio agrupados en 6 espacios o escenarios: Urbano - E1, Semiurbano/Industrial/Periferia Urbana - E2, Forestal - E3, Agricola - E4, Geologico/Volcanico - E5 y Otros Espacios Agua, Nubes y Sombras - E6. El tipo de sensores evaluados se caracteriza por registrar imagenes en un amplio rango de bandas, estrechas y contiguas, del espectro electromagnetico. La Tesis se ha centrado en el desarrollo de tecnicas que permiten separar y extraer automaticamente pixeles o grupos de pixeles cuya firma espectral difiere de manera discriminante de las que tiene alrededor, adoptando para ello como espacio muestral parte o el conjunto de las bandas espectrales en las que ha registrado radiancia el sensor hiperespectral. Un factor a tener en cuenta en la investigacion ha sido el propio instrumento de medida, es decir, la caracterizacion de los distintos subsistemas, sensores imagen y auxiliares, que intervienen en el proceso. Para poder emplear cuantitativamente los datos medidos ha sido necesario definir las relaciones espaciales y espectrales del sensor con la superficie observada y las potenciales anomalias y patrones objetivos de deteccion. Se ha analizado la repercusion que en la deteccion de anomalias tiene el tipo de sensor, tanto en su configuracion espectral como en las estrategias de diseno a la hora de registrar la radiacion prodecente de las superficies, siendo los dos tipos principales de sensores estudiados los barredores o escaneres de espejo giratorio (whiskbroom) y los barredores o escaneres de empuje (pushbroom). Se han definido distintos escenarios en la investigacion, lo que ha permitido abarcar una amplia variabilidad de entornos geomorfologicos y de tipos de coberturas, en ambientes mediterraneos, de latitudes medias y tropicales. En resumen, esta Tesis presenta una tecnica de deteccion de anomalias para datos hiperespectrales denominada DAFT en su variante de PP, basada en una reduccion de la dimensionalidad proyectando el fondo en un rango de longitudes de onda del espectro termico distinto de la proyeccion de las anomalias u objetivos sin firma espectral conocida. La metodologia propuesta ha sido probada con imagenes hiperespectrales reales de diferentes sensores y en diferentes escenarios o espacios, por lo tanto de diferente fondo espectral tambien, donde los resultados muestran los beneficios de la aproximacion en la deteccion de una gran variedad de objetos cuyas firmas espectrales tienen suficiente desviacion respecto del fondo. La tecnica resulta ser automatica en el sentido de que no hay necesidad de ajuste de parametros, dando resultados significativos en todos los casos. Incluso los objetos de tamano subpixel, que no pueden distinguirse a simple vista por el ojo humano en la imagen original, pueden ser detectados como anomalias. Ademas, se realiza una comparacion entre el enfoque propuesto, la popular tecnica RX y otros detectores tanto en su modalidad global como local. El metodo propuesto supera a los demas en determinados escenarios, demostrando su capacidad para reducir la proporcion de falsas alarmas. Los resultados del algoritmo automatico DAFT desarrollado, han demostrado la mejora en la definicion cualitativa de las anomalias espectrales que identifican a entidades diferentes en o bajo superficie, reemplazando para ello el modelo clasico de distribucion normal con un metodo robusto que contempla distintas alternativas desde el momento mismo de la adquisicion del dato hiperespectral. Para su consecucion ha sido necesario analizar la relacion entre parametros biofisicos, como la reflectancia y la emisividad de los materiales, y la distribucion espacial de entidades detectadas respecto de su entorno. Por ultimo, el algoritmo DAFT ha sido elegido como el mas adecuado para sensores que adquieren datos en el TIR, ya que presenta el mejor acuerdo con los datos de referencia, demostrando una gran eficacia computacional que facilita su implementacion en un sistema de cartografia que proyecte de forma automatica en un marco geografico de referencia las anomalias detectadas, lo que confirma un significativo avance hacia un sistema en lo que se denomina cartografia en tiempo real. The aim of this Thesis is to develop a specific methodology in order to be applied in automatic detection anomalies processes using hyperspectral data also called hyperspectral scenes, and to improve the classification processes. Several scenarios, areas and their relationship with surfaces and objects have been tested. The spectral characteristics of reflectance parameter and emissivity in the pattern recognition of urban materials in several hyperspectral scenes have also been tested. Spectral ranges of the visible-near infrared (VNIR), shortwave infrared (SWIR) and thermal infrared (TIR) from hyperspectral data cubes of AHS (Airborne Hyperspectral System), HyMAP Imaging Spectrometer, CASI (Compact Airborne Spectrographic Imager), AVIRIS (Airborne Visible Infrared Imaging Spectrometer), HYDICE (Hyperspectral Digital Imagery Collection Experiment) and MASTER (MODIS/ASTER Simulator) have been used in this research. It is assumed that there is not prior knowledge of the targets in anomaly detection. Thus, the pixels are automatically separated according to their spectral information, significantly differentiated with respect to a background, either globally for the full scene, or locally by the image segmentation. Several experiments on different scenarios have been designed, analyzing the behavior of the standard RX anomaly detector and different methods based on subspace, image projection and segmentation-based anomaly detection methods. Results and their consequences in unsupervised classification processes are discussed. Detection of spectral anomalies aims at extracting automatically pixels that show significant responses in relation of their surroundings. This Thesis deals with the unsupervised technique of target detection, also called anomaly detection. Since this technique assumes no prior knowledge about the target or the statistical characteristics of the data, the only available option is to look for objects that are differentiated from the background. Several methods have been developed in the last decades, allowing a better understanding of the relationships between the image dimensionality and the optimization of search procedures as well as the subpixel differentiation of the spectral mixture and its implications in anomalous responses. In other sense, image spectrometry has proven to be efficient in the characterization of materials, based on statistical methods using a specific reflection and absorption bands. Spectral configurations in the VNIR, SWIR and TIR have been successfully used for mapping materials in different urban scenarios. There has been an increasing interest in the use of high resolution data (both spatial and spectral) to detect small objects and to discriminate surfaces in areas with urban complexity. This has come to be known as target detection which can be either supervised or unsupervised. In supervised target detection, algorithms lean on prior knowledge, such as the spectral signature. The detection process for matching signatures is not straightforward due to the complications of converting data airborne sensor with material spectra in the ground. This could be further complicated by the large number of possible objects of interest, as well as uncertainty as to the reflectance or emissivity of these objects and surfaces. An important objective in this research is to establish relationships that allow linking spectral anomalies with what can be called informational anomalies and, therefore, identify information related to anomalous responses in some places rather than simply spotting differences from the background. The development in recent years of new hyperspectral sensors and techniques, widen the possibilities for applications in remote sensing of the Earth. Remote sensing systems measure and record electromagnetic disturbances that the surveyed objects induce in their surroundings, by means of different sensors mounted on airborne or space platforms. Map updating is important for management and decisions making people, because of the fast changes that usually happen in natural, urban and semi urban areas. It is necessary to optimize the methodology for obtaining the best from remote sensing techniques from hyperspectral data. The first problem with hyperspectral data is to reduce the dimensionality, keeping the maximum amount of information. Hyperspectral sensors augment considerably the amount of information, this allows us to obtain a better precision on the separation of material but at the same time it is necessary to calculate a bigger number of parameters, and the precision lowers with the increase in the number of bands. This is known as the Hughes effects (Bellman, 1957) . Hyperspectral imagery allows us to discriminate between a huge number of different materials however some land and urban covers are made up with similar material and respond similarly which produces confusion in the classification. The training and the algorithm used for mapping are also important for the final result and some properties of thermal spectrum for detecting land cover will be studied. In summary, this Thesis presents a new technique for anomaly detection in hyperspectral data called DAFT, as a PP's variant, based on dimensionality reduction by projecting anomalies or targets with unknown spectral signature to the background, in a range thermal spectrum wavelengths. The proposed methodology has been tested with hyperspectral images from different imaging spectrometers corresponding to several places or scenarios, therefore with different spectral background. The results show the benefits of the approach to the detection of a variety of targets whose spectral signatures have sufficient deviation in relation to the background. DAFT is an automated technique in the sense that there is not necessary to adjust parameters, providing significant results in all cases. Subpixel anomalies which cannot be distinguished by the human eye, on the original image, however can be detected as outliers due to the projection of the VNIR end members with a very strong thermal contrast. Furthermore, a comparison between the proposed approach and the well-known RX detector is performed at both modes, global and local. The proposed method outperforms the existents in particular scenarios, demonstrating its performance to reduce the probability of false alarms. The results of the automatic algorithm DAFT have demonstrated improvement in the qualitative definition of the spectral anomalies by replacing the classical model by the normal distribution with a robust method. For their achievement has been necessary to analyze the relationship between biophysical parameters such as reflectance and emissivity, and the spatial distribution of detected entities with respect to their environment, as for example some buried or semi-buried materials, or building covers of asbestos, cellular polycarbonate-PVC or metal composites. Finally, the DAFT method has been chosen as the most suitable for anomaly detection using imaging spectrometers that acquire them in the thermal infrared spectrum, since it presents the best results in comparison with the reference data, demonstrating great computational efficiency that facilitates its implementation in a mapping system towards, what is called, Real-Time Mapping.
Resumo:
The annual grass Brachypodium distachyon has been recently recognized as the model plant for functional genomics of temperate grasses, including cereals of economic relevance like wheat and barley. Sixty-two lines of B. distachyon were assessed for response to drought stress and heat tolerance. All these lines, except the reference genotype BD21, derive from specimens collected in 32 distinct locations of the Iberian Peninsula, covering a wide range of geo- climatic conditions. Sixteen lines of Brachypodium hybridum, an allotetraploid closely related to B. distachyon were used as reference of abiotic-stress well-adapted genotypes. Drought tolerance was assessed in a green-house trial. At the rosette-stage, no irrigation was applied to treated plants whereas their replicates at the control were maintained well watered during all the experiment. Thermographic images of treated and control plants were taken after 2 and 3 weeks of drought treatment, when stressed plants showed medium and extreme wilting symptoms. The mean leaf temperature of stressed (LTs) and control (LTc) plants was estimated based upon thermographic records from selected pixels (183 per image) that strictly correspond to leaf tissue. The response to drought was based on the analysis of two parameters: LTs and the thermal difference (TD) between stressed and control plants (LTs – LTc). The response to heat stress was based on LTc. Comparison of the mean values of these parameters showed that: 1) Genotypes better adapted to drought (B. hybridum lines) presented a higher LTs and TD than B. distachyon lines. 2) Under high temperature conditions, watered plants of B. hybridum lines maintained lower LTc than those of B. distachyon. Those results suggest that in these species adaptation to drought is linked to a more efficient stomata regulation: under water stress stomata are closed, increasing foliar temperature but also water use efficiency by reducing transpiration. With high temperature and water availability the results are less definite, but still seems that opening stomata allow plants to increase transpiration and therefore to diminish foliar temperature.