This paper proposes a first study in-depth of solar-fossil hybridization from a general perspective. It develops a set of useful parameters for analyzing and comparing hybrid plants, it studies the case of hybridizing Brayton cycles with current solar technologies and shows a tentative extrapolation of the results to integrated combined cycle systems (ISCSS). In particular, three points have been analyzed: the technical requirements for solar technologies to be hybridized with Brayton cycles, the temperatures and pressures at which hybridization would produce maximum power per unit of fossil fuel, and their mapping to current solar technologies and Brayton cycles. Major conclusions are that a hybrid plant works in optimum conditions which are not equal to those of the solar or power blocks considered independently, and that hybridizing at the Brayton cycle of a combined cycle could be energetically advantageous.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The study of the performance of an innovative receiver for linear Fresnel reflectors is carried out in this paper, and the results are analyzed with a physics perspective of the process. The receiver consists of a bundle of tubes parallel to the mirror arrays, resulting on a smaller cross section for the same receiver width as the number of tubes increases, due to the diminution of their diameter. This implies higher heat carrier fluid speeds, and thus, a more effective heat transfer process, although it conveys higher pumping power as well. Mass flow is optimized for different tubes diameters, different impinging radiation intensities and different fluid inlet temperatures. It is found that the best receiver design, namely the tubes diameter that maximizes the exergetic efficiency for given working conditions, is similar for the cases studied. There is a range of tubes diameters that imply similar efficiencies, which can drive to capital cost reduction thanks to the flexibility of design. In addition, the length of the receiver is also optimized, and it is observed that the optimal length is similar for the working conditions considered. As a result of this study, it is found that this innovative receiver provides an optimum design for the whole day, even though impinging radiation intensity varies notably. Thermal features of this type of receiver could be the base of a new generation of concentrated solar power plants with a great potential for cost reduction, because of the simplicity of the system and the lower weigh of the components, plus the flexibility of using the receiver tubes for different streams of the heat carrier fluid.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Reducing energy consumption and eliminating wastage are among the main goals of the European Union (EU) [2]. In order to satisfy all challenges arising from the Kyoto protocol, improving energy efficiency is a very important factor to take into account. There is significant potential for reducing consumption with cost-effective measures. Some studies show that 40% of our energy is consumed in buildings, and the EU has introduced legislation that aims to ensure that less energy is consumed in this way in the future.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The thermal and mechanical behaviour of isotactic polypropylene (iPP) nanocomposites reinforced with different loadings of inorganic fullerene-like tungsten disulfide (IF-WS2) nanoparticles was investigated. The IF-WS2 noticeably enhanced the polymer stiffness and strength, ascribed to their uniform dispersion, the formation of a large nanoparticle?matrix interface combined with a nucleating effect on iPP crystallization. Their reinforcement effect was more pronounced at high temperatures. However, a drop in ductility and toughness was found at higher IF-WS2 concentrations. The tensile behaviour of the nanocomposites was extremely sensitive to the strain rate and temperature, and their yield strength was properly described by the Eyring s equation. The activation energy increased while the activation volume decreased with increasing nanoparticle loading, indicating a reduction in polymer chain motion. The nanoparticles improved the thermomechanical properties of iPP: raised the glass transition and heat deflection temperatures while decreased the coefficient of thermal expansion. The nanocomposites also displayed superior flame retardancy with longer ignition time and reduced peak heat release rate. Further, a gradual rise in thermal conductivity was found with increasing IF-WS2 loading both in the glassy and rubbery states. The results presented herein highlight the benefits and high potential of using IF-nanoparticles for enhancing the thermomechanical properties of thermoplastic polymers compared to other nanoscale fillers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents different test alternatives which can be used on-site in a PV installation to detect potential induced degradation (PID) in modules. The testing procedures proposed are: thermal imaging; electroluminescence imaging; open circuit voltage measurements; operating voltage measurements; IV curve measurements; and dark IV curve measurements. Advantages and disadvantages of each test are reported.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Poly(3-hydroxybutyrate) (PHB) nanocomposites containing environmentally-friendly tungsten disulphide inorganic nanotubes (INTeWS2) have been successfully prepared by a simple solution blending method. The dynamic and isothermal crystallization studies by differential scanning calorimetry (DSC) demonstrated that the INTeWS2 exhibits much more prominent nucleation activity on the crystallization of PHB than specific nucleating agents or other nanoscale fillers. Both crystallization rate and crystallinity significantly increase in the nanocomposites compared to neat PHB. These changes occur without modifying the crystalline structure of PHB in the nanocomposites, as shown by wide-angle X-ray diffraction (WAXS) and infrared/Raman spectroscopy. Other parameters such as the Avrami exponent, the equilibrium melting temperature, global rate constant and the fold surface free energy of PHB chains in the nanocomposites were obtained from the calorimetric data in order to determine the influence of the INTeWS2 filler. The addition of INTeWS2 remarkably influences the energetics and kinetics of nucleation and growth of PHB, reducing the fold surface free energy by up to 20%. Furthermore, these nanocomposites also show an improvement in both tribological and mechanical (hardness and modulus) properties with respect to pure PHB evidenced by friction and nanoindentation tests, which is of important potential interest for industrial and medical applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Los muros cortina modulares están constituidos por paneles prefabricados que se fijan al edificio a través de anclajes a lo largo del borde del forjado. El proceso de prefabricación garantiza buena calidad y control de los acabados y el proceso de instalación es rápido y no requiere andamiaje. Por estas razones su uso está muy extendido en torres. Sin embargo, el diseño de los marcos de aluminio podría ser más eficiente si se aprovechara la rigidez de los vidrios para reducir la profundidad estructural de los montantes. Asimismo, se podrían reducir los puentes térmicos en las juntas si se sustituyeran los marcos por materiales de menor conductividad térmica que el aluminio. Esta investigación persigue desarrollar un muro cortina alternativo que reduzca la profundidad estructural, reduzca la transmisión térmica en las juntas y permita un acabado enrasado al interior, sin que sobresalgan los montantes. La idea consiste en conectar un marco de material compuesto de fibra de vidrio a lo largo del borde del vidrio aislante a través de adhesivos estructurales para así movilizar una acción estructural compuesta entre los dos vidrios y lograr una baja transmitancia térmica. El marco ha de estar integrado en la profundidad del vidrio aislante. En una primera fase se han efectuado cálculos estructurales y térmicos preliminares para evaluar las prestaciones a un nivel esquemático. Además, se han realizado ensayos a flexión en materiales compuestos de fibra de vidrio y ensayos a cortante en las conexiones adhesivas entre vidrio y material compuesto. Con la información obtenida se ha seleccionado el material del marco y del adhesivo y se han efectuado cambios sobre el diseño original. Los análisis numéricos finales demuestran una reducción de la profundidad estructural de un 80% y una reducción de la transmisión térmica de un 6% en comparación con un sistema convencional tomado como referencia. El sistema propuesto permite obtener acabados enrasados. ABSTRACT Unitised curtain wall systems consist of pre manufactured cladding panels which can be fitted to the building via pre fixed brackets along the edge of the floor slab. They are universally used for high rise buildings because the factory controlled assembly of units ensures high quality and allows fast installation without external access. However, its frame is structurally over-dimensioned because it is designed to carry the full structural load, failing to take advantage of potential composite contribution of glass. Subsequently, it is unnecessarily deep, occupying valuable space, and protrudes to the inside, causing visual disruption. Moreover, it is generally made of high thermal conductivity metal alloys, contributing to substantial thermal transmission at joints. This research aims to develop a novel frame-integrated unitised curtain wall system that will reduce thermal transmission at joints, reduce structural depth significantly and allow an inside flush finish. The idea is to adhesively bond a Fibre Reinforced Polymer (FRP) frame to the edge of the Insulated Glass Unit (IGU), thereby achieving composite structural behaviour and low thermal transmittance. The frame is to fit within the glazing cavity depth. Preliminary analytical structural and numerical thermal calculations are carried out to assess the performance of an initial schematic design. 4-point bending tests on GFRP and single-lap shear tests on bonded connections between GFRP and glass are performed to inform the frame and adhesive material selection process and to characterise these materials. Based on the preliminary calculations and experimental tests, some changes are put into effect to improve the performance of the system and mitigate potential issues. Structural and thermal numerical analysis carried out on the final detail design confirm a reduction of the structural depth to almost one fifth and a reduction of thermal transmission of 6% compared to a benchmark conventional system. A flush glazed appearance both to the inside and the outside are provided while keeping the full functionality of a unitised system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of thermal shields to reduce radiation heat loss in Siemens-type CVD reactors is analyzed, both theoretically and experimentally. The potential savings from the use of the thermal shields is first explored using a radiation heat model that takes emissivity variations with wavelength into account, which is important for materials that do not behave as grey bodies. The theoretical calculations confirm that materials with lower surface emissivity lead to higher radiation savings. Assuming that radiation heat loss is responsible for around 50% of the total power consumption, a reduction of 32.9% and 15.5% is obtained if thermal shields with constant emissivities of 0.3 and 0.7 are considered, respectively. Experiments considering different thermal shields are conducted in a laboratory CVD reactor, confirming that the real materials do not behave as grey bodies, and proving that significant energy savings in the polysilicon deposition process are obtained. Using silicon as a thermal shield leads to energy savings of between 26.5-28.5%. For wavelength-dependent emissivities, the model shows that there are significant differences in radiation heat loss, of around 25%, when compared to that of constant emissivity. The results of the model highlight the importance of having reliable data on the emissivities within the relevant range of wavelengths, and at deposition temperatures, which remains a pending issue.