14 resultados para Tests de non corrélation

em Universidad Politécnica de Madrid


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The use of seismic hysteretic dampers for passive control is increasing exponentially in recent years for both new and existing buildings. In order to utilize hysteretic dampers within a structural system, it is of paramount importance to have simplified design procedures based upon knowledge gained from theoretical studies and validated with experimental results. Non-linear Static Procedures (NSPs) are presented as an alternative to the force-based methods more common nowadays. The application of NSPs to conventional structures has been well established; yet there is a lack of experimental information on how NSPs apply to systems with hysteretic dampers. In this research, several shaking table tests were conducted on two single bay and single story 1:2 scale structures with and without hysteretic dampers. The maximum response of the structure with dampers in terms of lateral displacement and base shear obtained from the tests was compared with the prediction provided by three well-known NSPs: (1) the improved version of the Capacity Spectrum Method (CSM) from FEMA 440; (2) the improved version of the Displacement Coefficient Method (DCM) from FEMA 440; and (3) the N2 Method implemented in Eurocode 8. In general, the improved version of the DCM and N2 methods are found to provide acceptable accuracy in prediction, but the CSM tends to underestimate the response.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Contaminated soil reuse was investigated, with higher profusion, throughout the early 90’s, coinciding with the 1991 Gulf War, when efforts to amend large crude oil releases began in geotechnical assessment of contaminated soils. Isolated works referring to geotechnical testing with hydrocarbon ground contaminants are described in the state-of-the-art, which have been extended to other type of contaminated soil references. Contaminated soils by light non-aquous phase liquids (LNAPL) bearing capacity reduction has been previously investigated from a forensic point of view. To date, all the research works have been published based on the assumption of constant contaminant saturation for the entire soil mass. In contrast, the actual LNAPLs distribution plumes exhibit complex flow patterns which are subject to physical and chemical changes with time and distance travelled from the release source. This aspect has been considered along the present text. A typical Madrid arkosic soil formation is commonly known as Miga sand. Geotechnical tests have been carried out, with Miga sand specimens, in incremental series of LNAPL concentrations in order to observe the soil engineering properties variation due to a contamination increase. Results are discussed in relation with previous studies and as a matter of fact, soil mechanics parameters change in the presence of LNAPL, showing different tendencies according to each test and depending on the LNAPL content, as well as to the specimen’s initially planned relative density, dense or loose. Geotechnical practical implications are also commented on and analyzed. Variation on geotechnical properties may occur only within the external contour of contamination distribution plume. This scope has motivated the author to develop a physical model based on transparent soil technology. The model aims to reproduce the distribution of LNAPL into the ground due to an accidental release from a storage facility. Preliminary results indicate that the model is a potentially complementary tool for hydrogeological applications, site-characterization and remediation treatment testing within the framework of soil pollution events. A description of the test setup of an innovative three dimensional physical model for the flow of two or more phases, in porous media, is presented herein, along with a summary of the advantages, limitations and future applications for modeling with transparent material. En los primeros años de la década de los años 90, del siglo pasado, coincidiendo con la Guerra del Golfo en 1991, se investigó intensamente sobre la reutilización de suelos afectados por grandes volúmenes de vertidos de crudo, fomentándose la evaluación geotécnica de los suelos contaminados. Se describen, en el estado del arte de esta tésis, una serie de trabajos aislados en relación con la caracterización geotécnica de suelos contaminados con hidrocarburos, descripción ampliada mediante referencias relacionadas con otros tipos de contaminación de suelos. Existen estudios previos de patología de cimentaciones que analizan la reducción de la capacidad portante de suelos contaminados por hidrocarburos líquidos ligeros en fase no acuosa (acrónimo en inglés: LNAPL de “Liquid Non-Aquous Phase Liquid”). A fecha de redacción de la tesis, todas las publicaciones anteriores estaban basadas en la consideración de una saturación del contaminante constante en toda la extensión del terreno de cimentación. La distribución real de las plumas de contaminante muestra, por el contrario, complejas trayectorias de flujo que están sujetas a cambios físico-químicos en función del tiempo y la distancia recorrida desde su origen de vertido. Éste aspecto ha sido considerado y tratado en el presente texto. La arena de Miga es una formación geológica típica de Madrid. En el ámbito de esta tesis se han desarrollado ensayos geotécnicos con series de muestras de arena de Miga contaminadas con distintas concentraciones de LNAPL con el objeto de estimar la variación de sus propiedades geotécnicas debido a un incremento de contaminación. Se ha realizado una evaluación de resultados de los ensayos en comparación con otros estudios previamente analizados, resultando que las propiedades mecánicas del suelo, efectivamente, varían en función del contenido de LNAPL y de la densidad relativa con la que se prepare la muestra, densa o floja. Se analizan y comentan las implicaciones de carácter práctico que supone la mencionada variación de propiedades geotécnicas. El autor ha desarrollado un modelo físico basado en la tecnología de suelos transparentes, considerando que las variaciones de propiedades geotécnicas únicamente deben producirse en el ámbito interior del contorno de la pluma contaminante. El objeto del modelo es el de reproducir la distribución de un LNAPL en un terreno dado, causada por el vertido accidental de una instalación de almecenamiento de combustible. Los resultados preliminares indican que el modelo podría emplearse como una herramienta complementaria para el estudio de eventos contaminantes, permitiendo el desarrollo de aplicaciones de carácter hidrogeológico, caracterización de suelos contaminados y experimentación de tratamientos de remediación. Como aportación de carácter innovadora, se presenta y describe un modelo físico tridimensional de flujo de dos o más fases a través de un medio poroso transparente, analizándose sus ventajas e inconvenientes así como sus limitaciones y futuras aplicaciones.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Freezing of water or salt solution in concrete pores is a main cause for severe damage and significant reduction of the service life. Most of the freeze-thaw (F-T) accelerated tests measure the scaling of concrete by weighting. This paper presents complementary procedures based on the use of strain gages and ultrasonic pulse velocity (UPV) for measuring the deterioration of concrete due to freezing and thawing. These non-destructive testing (NDT) procedures are applied to two types of concretes, one susceptible to F-T damage and the other does not. The results show a good correlation between scaling and the measurements obtained with NDT. Showing NDT the advantage to detect before the damage and to perform continuous measurement

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a novel approach for detecting severe obstructive sleep apnea (OSA) cases by introducing non-linear analysis into sustained speech characterization. The proposed scheme was designed for providing additional information into our baseline system, built on top of state-of-the-art cepstral domain modeling techniques, aiming to improve accuracy rates. This new information is lightly correlated with our previous MFCC modeling of sustained speech and uncorrelated with the information in our continuous speech modeling scheme. Tests have been performed to evaluate the improvement for our detection task, based on sustained speech as well as combined with a continuous speech classifier, resulting in a 10% relative reduction in classification for the first and a 33% relative reduction for the fused scheme. Results encourage us to consider the existence of non-linear effects on OSA patients' voices, and to think about tools which could be used to improve short-time analysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We provide a method whereby, given mode and (upper approximation) type information, we can detect procedures and goals that can be guaranteed to not fail (i.e., to produce at least one solution or not termínate). The technique is based on an intuitively very simple notion, that of a (set of) tests "covering" the type of a set of variables. We show that the problem of determining a covering is undecidable in general, and give decidability and complexity results for the Herbrand and linear arithmetic constraint systems. We give sound algorithms for determining covering that are precise and efiicient in practice. Based on this information, we show how to identify goals and procedures that can be guaranteed to not fail at runtime. Applications of such non-failure information include programming error detection, program transiormations and parallel execution optimization, avoiding speculative parallelism and estimating lower bounds on the computational costs of goals, which can be used for granularity control. Finally, we report on an implementation of our method and show that better results are obtained than with previously proposed approaches.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Increasing attention is being paid to the possible development of non-invasive tests for the assessment of the quality of fruits We propose a novel non-destructive method for the measurement of the internal optical properties of fruits and vegetables by means of time resolved reflectance spectroscopy in the visible and NIR range. A fully automated instrumentation for time-resolved reflectance measurements was developed It is based on mode-locked laser sources and electronics for time-correlated single photon counting, and provides a time-resolution of 120-160 ps The system was used to probe the optical properties of several species and varieties of fruits and vegetables in the red and NIR range (650-1000 nm). In most fruits, the absorption line shape is dominated by the absorption peak of water, centred around 970 nm Generally, the absorption spectra also show the spectral features typical of chlorophyll, with maximum at 675 nm In particular, for what concerns apples, variations in peak intensity are observed depending on the variety, the degree of ripeness as well as the position on the apple. For all the species and varieties considered, the transport scattering coefficient decreases progressively upon increasing the wavelength.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Increasing attention is being paid to the possible development of non-invasive tests for the assessment of the quality of Fruits. We propose a novel non-destructive method for the measurement of the internal optical properties of fruits and vegetables by means of lime-resolved reflectance spectroscopy in the visible and NIR range. A Fully automated instrumentation for time-resolved reflectance measurements was developed. It is based on mode-locked laser sources and electronics for time-correlated single photon counting, and provides a time-resolution of 120-160 ps. The system was used to probe the optical properties of several species and varieties of Fruits and vegetables in the red and NIR range (650-1000 nm). In most Fruits, the absorption line shape is dominated by the absorption peak of water, centred around 970 nm. Generally, the absorption spectra also show the spectral features typical of chlorophyll, with maximum at 675 nm. In particular, for what concerns apples, variations in peak intensity are observed depending on the variety, the degree of ripeness as well as the position on the apple. For all the species and varieties considered, the transport scattering coefficient decreases progressively upon increasing the wavelength.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Woolliness (mealiness in other fruits) is a negative attribute of peach sensory texture that is a physiological disorder associated with inadequate cold storage. It is characterised by lack of crispness and juiciness without variation in the tissue water content (Harker and Hallet, 1992). Many attempts have been made to develop destructive instrumental procedures to detect mealiness and woolliness. Non-destructive procedures attempted include using nuclear magnetic resonance (Sonego et al., 1995). However, this technique has economical limitations and is not practical at present. Non-destructive impact tests and NIR are non-destructive techniques which have been used to assess internal characteristics of fruits (Chen and Sun, 1991). The objective of this study was to develop a novel non-destructive procedure to identify woolly peaches by combining impact and NIR approaches.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Un caloducto en bucle cerrado o Loop Heat Pipe (LHP) es un dispositivo de transferencia de calor cuyo principio de operación se basa en la evaporación/condensación de un fluido de trabajo, que es bombeado a través de un circuito cerrado gracias a fuerzas de capilaridad. Gracias a su flexibilidad, su baja masa y su mínimo (incluso nulo) consumo de potencia, su principal aplicación ha sido identificada como parte del subsistema de control térmico de vehículos espaciales. En el presente trabajo se ha desarrollado un LHP capaz de funcionar eficientemente a temperaturas de hasta 125 oC, siguiendo la actual tendencia de los equipos a bordo de satélites de incrementar su temperatura de operación. En la selección del diseño optimo para dicho LHP, la compatibilidad entre materiales y fluido de trabajo se identificó como uno de los puntos clave. Para seleccionar la mejor combinación, se llevó a cabo una exhaustiva revisión del estado del arte, además de un estudio especifico que incluía el desarrollo de un banco de ensayos de compatibilidad. Como conclusión, la combinación seleccionada como la candidata idónea para ser integrada en el LHP capaz de operar hasta 125 oC fue un evaporador de acero inoxidable, líneas de titanio y amoniaco como fluido de trabajo. En esa línea se diseñó y fabricó un prototipo para ensayos y se desarrolló un modelo de simulación con EcosimPro para evaluar sus prestaciones. Se concluyó que el diseño era adecuado para el rango de operación definido. La incompatibilidad entre el fluido de trabajo y los materiales del LHP está ligada a la generación de gases no condensables. Para un estudio más detallado de los efectos de dichos gases en el funcionamiento del LHP se analizó su comportamiento con diferentes cantidades de nitrógeno inyectadas en su cámara de compensación, simulando un gas no condensable formado en el interior del dispositivo. El estudio se basó en el análisis de las temperaturas medidas experimentalmente a distintos niveles de potencia y temperatura de sumidero o fuente fría. Adicionalmente, dichos resultados se compararon con las predicciones obtenidas por medio del modelo en EcosimPro. Las principales conclusiones obtenidas fueron dos. La primera indica que una cantidad de gas no condensable más de dos veces mayor que la cantidad generada al final de la vida de un satélite típico de telecomunicaciones (15 años) tiene efectos casi despreciables en el funcionamiento del LHP. La segunda es que el principal efecto del gas no condensable es una disminución de la conductancia térmica, especialmente a bajas potencias y temperaturas de sumidero. El efecto es más significativo cuanto mayor es la cantidad de gas añadida. Asimismo, durante la campaña de ensayos se observó un fenómeno no esperado para grandes cantidades de gas no condensable. Dicho fenómeno consiste en un comportamiento oscilatorio, detectado tanto en los ensayos como en la simulación. Este efecto es susceptible de una investigación más profunda y los resultados obtenidos pueden constituir la base para dicha tarea. ABSTRACT Loop Heat Pipes (LHPs) are heat transfer devices whose operating principle is based on the evaporation/condensation of a working fluid, and which use capillary pumping forces to ensure the fluid circulation. Thanks to their flexibility, low mass and minimum (even null) power consumption, their main application has been identified as part of the thermal control subsystem in spacecraft. In the present work, an LHP able to operate efficiently up to 125 oC has been developed, which is in line with the current tendency of satellite on-board equipment to increase their operating temperatures. In selecting the optimal LHP design for the elevated temperature application, the compatibility between the materials and working fluid has been identified as one of the main drivers. An extensive literature review and a dedicated trade-off were performed, in order to select the optimal combination of fluids and materials for the LHP. The trade-off included the development of a dedicated compatibility test stand. In conclusion, the combination of stainless steel evaporator, titanium piping and ammonia as working fluid was selected as the best candidate to operate up to 125 oC. An LHP prototype was designed and manufactured and a simulation model in EcosimPro was developed to evaluate its performance. The first conclusion was that the defined LHP was suitable for the defined operational range. Incompatibility between the working fluid and LHP materials is linked to Non Condensable Gas (NCG) generation. Therefore, the behaviour of the LHP developed with different amounts of nitrogen injected in its compensation chamber to simulate NCG generation, was analyzed. The LHP performance was studied by analysis of the test results at different temperatures and power levels. The test results were also compared to simulations in EcosimPro. Two additional conclusions can be drawn: (i) the effects of an amount of more than two times the expected NCG at the end of life of a typical telecommunications satellite (15 years) is almost negligible on the LHP operation, and (ii) the main effect of the NCG is a decrease in the LHP thermal conductance, especially at low temperatures and low power levels. This decrease is more significant with the progressive addition of NCG. An unexpected phenomenon was observed in the LHP operation with large NCG amounts. Namely, an oscillatory behaviour, which was observed both in the tests and the simulation. This effect provides the basis for further studies concerning oscillations in LHPs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper discusses the torsional response of a scaled reinforced concrete frame structure subjected to several uniaxial shaking table tests. The tested structure is nominally symmetric in the direction of shaking and exhibits torsion attributable to non-uniform yielding of structural components and uncertainties in the building process. Asymmetric behavior is analyzed in terms of displacement, strain in reinforcing bars, energy dissipated at plastic hinges, and damage at section and frame levels. The results show that for low levels of seismic hazard, for which the structure is expected to perform basically within the elastic range, the accidental eccentricity is not a concern for the health of the structure, but it significantly increases the lateral displacement demand in the frames (about 30%) and this might cause significant damage to non-structural components. For high levels of seismic hazard the effects of accidental torsion become less important. These results underline the need to consider accidental eccentricity in evaluating the performance of a structure for very frequent or frequent earthquakes, and suggest that consideration of torsion may be neglected for performance levels associated with rare or very rare earthquakes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The paper reports on a collaborative effort between the Swiss Federal Nuclear Safety Inspectorate (ENSI) and their consultants Principia and Stangenberg. As part of the IMPACT III project, reduced scale impact tests of reinforced concrete structures were carried out. The simulation of test X3 is presented here and the numerical results are compared with those obtained in the test, carried out in August 2013. The general object is to improve the safety of nuclear facilities and, more specifically, to demonstrate the capabilities of current simulation techniques to reproduce the behaviour of a reinforced concrete structure impacted by a soft missile. The missile is a steel tube with a mass of 50 kg and travelling at 140 m/s. The target is a 250 mm thick, 2,1 m by 2,1 m reinforced concrete wall, held in a stiff supporting frame. The reinforcement includes both longitudinal and transverse rebars. Calculations were carried out before and after the test with Abaqus (Principia) and SOFiSTiK (Stangenberg). In the Abaqus simulation the concrete is modelled using solid elements and a damaged plasticity formulation, the rebars with embedded beam elements, and the missile with shell elements. In SOFiSTiK the target is modelled with non-linear, layered shell elements for the reinforcement on both sides; non-linear shear deformations of shell/plate elements are approximately included. The results generally indicate a good agreement between calculations and measurements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Poly(L‐lactide) is a widely studied biomaterial, currently approved for use in a range of medical devices. Its mechanical properties can be tailored giving the material different crystallinity degrees. PLLA presents a complex non‐linear behaviour that depends not only on structural parameters such as crystallinity degree but also on external parameters such as strain rate and temperature. Failure of polymeric implants is attributed to their intrinsic time‐dependent performance under static loading conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a new selective and non-directional protection method to detect ground faults in neutral isolated power systems. The new proposed method is based on the comparison of the rms value of the residual current of all the lines connected to a bus, and it is able to determine the line with ground defect. Additionally, this method can be used for the protection of secondary substation. This protection method avoids the unwanted trips produced by wrong settings or wiring errors, which sometimes occur in the existing directional ground fault protections. This new method has been validated through computer simulations and experimental laboratory tests.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The paper proposes a new application of non-parametric statistical processing of signals recorded from vibration tests for damage detection and evaluation on I-section steel segments. The steel segments investigated constitute the energy dissipating part of a new type of hysteretic damper that is used for passive control of buildings and civil engineering structures subjected to earthquake-type dynamic loadings. Two I-section steel segments with different levels of damage were instrumented with piezoceramic sensors and subjected to controlled white noise random vibrations. The signals recorded during the tests were processed using two non-parametric methods (the power spectral density method and the frequency response function method) that had never previously been applied to hysteretic dampers. The appropriateness of these methods for quantifying the level of damage on the I-shape steel segments is validated experimentally. Based on the results of the random vibrations, the paper proposes a new index that predicts the level of damage and the proximity of failure of the hysteretic damper