40 resultados para Rotter I-E test

em Universidad Politécnica de Madrid


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The A.T.I, method is based on the control theory and is the result of the author's personal experiences and observations. The academic year 1971-72 has so far shown that the practical results that may be expected from it can not as yet be evaluated ; all we can do for the present is to look at how it is being applied. However, as the reader will later perceive, most of our arguments are based on general theories,as it is felt that those which relate to the system are not as important as those which refer to the means, since it is the latter which later condition the application of the method to other systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This Doctoral Thesis entitled Contribution to the analysis, design and assessment of compact antenna test ranges at millimeter wavelengths aims to deepen the knowledge of a particular antenna measurement system: the compact range, operating in the frequency bands of millimeter wavelengths. The thesis has been developed at Radiation Group (GR), an antenna laboratory which belongs to the Signals, Systems and Radiocommunications department (SSR), from Technical University of Madrid (UPM). The Radiation Group owns an extensive experience on antenna measurements, running at present four facilities which operate in different configurations: Gregorian compact antenna test range, spherical near field, planar near field and semianechoic arch system. The research work performed in line with this thesis contributes the knowledge of the first measurement configuration at higher frequencies, beyond the microwaves region where Radiation Group features customer-level performance. To reach this high level purpose, a set of scientific tasks were sequentially carried out. Those are succinctly described in the subsequent paragraphs. A first step dealed with the State of Art review. The study of scientific literature dealed with the analysis of measurement practices in compact antenna test ranges in addition with the particularities of millimeter wavelength technologies. Joint study of both fields of knowledge converged, when this measurement facilities are of interest, in a series of technological challenges which become serious bottlenecks at different stages: analysis, design and assessment. Thirdly after the overview study, focus was set on Electromagnetic analysis algorithms. These formulations allow to approach certain electromagnetic features of interest, such as field distribution phase or stray signal analysis of particular structures when they interact with electromagnetic waves sources. Properly operated, a CATR facility features electromagnetic waves collimation optics which are large, in terms of wavelengths. Accordingly, the electromagnetic analysis tasks introduce an extense number of mathematic unknowns which grow with frequency, following different polynomic order laws depending on the used algorithmia. In particular, the optics configuration which was of our interest consisted on the reflection type serrated edge collimator. The analysis of these devices requires a flexible handling of almost arbitrary scattering geometries, becoming this flexibility the nucleus of the algorithmia’s ability to perform the subsequent design tasks. This thesis’ contribution to this field of knowledge consisted on reaching a formulation which was powerful at the same time when dealing with various analysis geometries and computationally speaking. Two algorithmia were developed. While based on the same principle of hybridization, they reached different order Physics performance at the cost of the computational efficiency. Inter-comparison of their CATR design capabilities was performed, reaching both qualitative as well as quantitative conclusions on their scope. In third place, interest was shifted from analysis - design tasks towards range assessment. Millimetre wavelengths imply strict mechanical tolerances and fine setup adjustment. In addition, the large number of unknowns issue already faced in the analysis stage appears as well in the on chamber field probing stage. Natural decrease of dynamic range available by semiconductor millimeter waves sources requires in addition larger integration times at each probing point. These peculiarities increase exponentially the difficulty of performing assessment processes in CATR facilities beyond microwaves. The bottleneck becomes so tight that it compromises the range characterization beyond a certain limit frequency which typically lies on the lowest segment of millimeter wavelength frequencies. However the value of range assessment moves, on the contrary, towards the highest segment. This thesis contributes this technological scenario developing quiet zone probing techniques which achieves substantial data reduction ratii. Collaterally, it increases the robustness of the results to noise, which is a virtual rise of the setup’s available dynamic range. In fourth place, the environmental sensitivity of millimeter wavelengths issue was approached. It is well known the drifts of electromagnetic experiments due to the dependance of the re sults with respect to the surrounding environment. This feature relegates many industrial practices of microwave frequencies to the experimental stage, at millimeter wavelengths. In particular, evolution of the atmosphere within acceptable conditioning bounds redounds in drift phenomena which completely mask the experimental results. The contribution of this thesis on this aspect consists on modeling electrically the indoor atmosphere existing in a CATR, as a function of environmental variables which affect the range’s performance. A simple model was developed, being able to handle high level phenomena, such as feed - probe phase drift as a function of low level magnitudes easy to be sampled: relative humidity and temperature. With this model, environmental compensation can be performed and chamber conditioning is automatically extended towards higher frequencies. Therefore, the purpose of this thesis is to go further into the knowledge of millimetre wavelengths involving compact antenna test ranges. This knowledge is dosified through the sequential stages of a CATR conception, form early low level electromagnetic analysis towards the assessment of an operative facility, stages for each one of which nowadays bottleneck phenomena exist and seriously compromise the antenna measurement practices at millimeter wavelengths.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A small Positron Emission Tomography demonstrator based on LYSO slabs and Silicon Photomultiplier matrices is under construction at the University and INFN of Pisa. In this paper we present the characterization results of the read-out electronics and of the detection system. Two SiPM matrices, composed by 8 × 8 SiPM pixels, 1.5 mm pitch, have been coupled one to one to a LYSO crystals array. Custom Front-End ASICs were used to read the 64 channels of each matrix. Data from each Front-End were multiplexed and sent to a DAQ board for the digital conversion; a motherboard collects the data and communicates with a host computer through a USB port. Specific tests were carried out on the system in order to assess its performance. Futhermore we have measured some of the most important parameters of the system for PET application.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Underground coal mines explosions generally arise from the inflammation of a methane/air mixture. This explosion can also generate a subsequent coal dust explosion. Traditionally such explosions have being fought eliminating one or several of the factors needed by the explosion to take place. Although several preventive measures are taken to prevent explosions, other measures should be considered to reduce the effects or even to extinguish the flame front. Unlike other protection methods that remove one or two of the explosion triangle elements, namely; the ignition source, the oxidizing agent and the fuel, explosion barriers removes all of them: reduces the quantity of coal in suspension, cools the flame front and the steam generated by vaporization removes the oxygen present in the flame. Passive water barriers are autonomous protection systems against explosions that reduce to a satisfactory safety level the effects of methane and/or flammable dust explosions. The barriers are activated by the pressure wave provoked in the explosion destroying the barrier troughs and producing a uniform dispersion of the extinguishing agent throughout the gallery section in quantity enough to extinguish the explosion flame. Full scale tests have been carried out in Polish Barbara experimental mine at GIG Central Mining Institute in order to determine the requirements and the optimal installation conditions of these devices for small sections galleries which are very frequent in the Spanish coal mines. Full scale tests results have been analyzed to understand the explosion timing and development, in order to assess on the use of water barriers in the typical small crosssection Spanish galleries. Several arrangements of water barriers have been designed and tested to verify the effectiveness of the explosion suppression in each case. The results obtained demonstrate the efficiency of the water barriers in stopping the flame front even with smaller amounts of water than those established by the European standard. According to the tests realized, water barriers activation times are between 0.52 s and 0.78 s and the flame propagation speed are between 75 m/s and 80 m/s. The maximum pressures (Pmax) obtained in the full scale tests have varied between 0.2 bar and 1.8 bar. Passive barriers protect effectively against the spread of the flame but cannot be used as a safeguard of the gallery between the ignition source and the first row of water troughs or bags, or even after them, as the pressure could remain high after them even if the flame front has been extinguished.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Models based on degradation are powerful and useful tools to evaluate the reliability of those devices in which failure happens because of degradation in the performance parameters. This paper presents a procedure for assessing the reliability of concentrator photovoltaic (CPV) modules operating outdoors in real-time conditions. With this model, the main reliability functions are predicted. This model has been applied to a real case with a module composed of GaAs single-junction solar cells and total internal reflection (TIR) optics

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper is a first step of a research about the analysis of the richness of the existing sounds in the Plaza Mayor, due to the old and traditional shops and bars under its porticoes together with the huge daily affluence of people. In this paper we study the sound preferences of the salesmen and bar tenders at those traditional shops. These sound preferences include particular sounds, time of occurrence and date of specific annoying and pleasant sounds perceived at the square and the shops surrounding it. To carry out this study, several noise level measurements and socio-acoustic surveys were held. We will also try to correlate sound preferences and annoyance with noise levels of specific events existing at this particular square.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Communications Based Train Control Systems require high quality radio data communications for train signaling and control. Actually most of these systems use 2.4GHz band with proprietary radio transceivers and leaky feeder as distribution system. All them demand a high QoS radio network to improve the efficiency of railway networks. We present narrow band, broad band and data correlated measurements taken in Madrid underground with a transmission system at 2.4 GHz in a test network of 2 km length in subway tunnels. The architecture proposed has a strong overlap in between cells to improve reliability and QoS. The radio planning of the network is carefully described and modeled with narrow band and broadband measurements and statistics. The result is a network with 99.7% of packets transmitted correctly and average propagation delay of 20ms. These results fulfill the specifications QoS of CBTC systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work is based on the prototype High Engineering Test Reactor (HTTR) of the Japan Agency of Energy Atomic (JAEA). Its objective is to describe an adequate deterministic model to be used in the assessment of its design safety margins via damage domains. The concept of damage domain is defined and it is shown its relevance in the ongoing effort to apply dynamic risk assessment methods and tools based on the Theory of Stimulated Dynamics (TSD). To illustrate, we present results of an abnormal control rod (CR) withdrawal during subcritical condition and its comparison with results obtained by JAEA. No attempt is made yet to actually assess the detailed scenarios, rather to show how the approach may handle events of its kind

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Photovoltaic modules based on thin film technology are gaining importance in the photovoltaic market, and module installers and plant owners have increasingly begun to request methods of performing module quality control. These modules pose additional problems for measuring power under standard test conditions (STC), beyond problems caused by the temperature of the module and the ambient variables. The main difficulty is that the modules’ power rates may vary depending both on the amount of time they have been exposed to the sun during recent hours and on their history of sunlight exposure. In order to assess the current state of the module, it is necessary to know its sunlight exposure history. Thus, an easily accomplishable testing method that ensures the repeatability of the measurements of the power generated is needed. This paper examines different tests performed on commercial thin film PV modules of CIS, a-Si and CdTe technologies in order to find the best way to obtain measurements. A method for obtaining indoor measurements of these technologies that takes into account periods of sunlight exposure is proposed. Special attention is paid to CdTe as a fast growing technology in the market.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A three node, displacement based, acoustic element is developed. In order to avoid spurious rotational modes, a higher order stiffness is introduced. The higher order stiffness is developed from an incompatible strain field which computes element volume changes under nodal rotational displacements fields. The higher order strain satisfies the IET requirements, non affecting convergence. The higher order stiffness is modulated, element by element, with a factor. Thus, the displacement based formulation is capable of placing the spurious rotational modes over the range of physical compressional modes that can be accurately captured by the mesh.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Una de mis muchas preocupaciones en el campo de la enseñanza, es y será, el sistema o procedimiento de evaluación a utilizar. Las observaciones efectuadas en mi localidad (Salamanca) me llevaron a la conclusión de que en un alto porcentaje de centros escolares, los profesores, guiados por unos criterios siempre personales, calificaban a sus alumnos con métodos totalmente subjetivos. Continuando con las observaciones a nivel provincial, los hechos son más evidentes, estamos acostumbrados a administrar programas y actividades, cuya evaluación se basa en la asistencia, la victoria o la derrota, etc. En octubre de 1977, el Consejo Superior de Deportes a través de su Delegación Provincial en Salamanca, inició un Plan Experimental de Promoción Físico-Deportiva Escolar, con la participación de más de medio centenar de centros de E.G.B. correspondiente a la capital y 11 localidades de la provincia. Se me propuso la dirección del mismo y con la colaboración de otros compañeros, comenzamos a elaborar su administración. Fué entonces, cuando al abordar nuevamente el problema de la evaluación, nos propusimos en un primer intento, que fuera lo más objetiva posible, para lo cual determinamos las medidas que teníamos que efectuar de cara a la consecución de los objetivos prefijados. La falta de personas especializadas y las dudas en cuanto a la autenticidad y objetividad en la recogida de los datos, nos obligó a desestimar las muestras recogidas y a plantearnos nuevamente el problema. En septiembre de 1979, después de estudiados todos los aspectos que más nos interesaban para la buena marcha del trabajo, nos dedicamos fundamentalmente a la formación y preparación del grupo de jueces (ocho personas especializadas), al objeto de conseguir una uniformidad de criterios a la hora de la aplicación de las pruebas. La finalidad del trabajo es establecer "standars" de la población escolar de los colegios nacionales de Educación General Básica de la localidad de Salamanca, en las edades comprendidas entre los 11 y 14 años, en forma de tablas de percentiles, basados en la edad y sexo, de forma que en el futuro nos sirvan: a) Como baremo calificador, ya que - hay que establecer con justeza los niveles a alcanzar. - nos podemos fiar de la justa interpretación que se dé a las respuestas del examinando, ya que son elementos de la máxima objetividad -el cronómetro y el metro-, los que interpretan y valoran dichas respuestas. b) Como elemento básico, para las futuras planificaciones del mencionado Plan Experimental. Al valorar el conjunto de una serie de pruebas motoras, los profesores, tendrán un índice determinador, que les servirá como fundamento de trabajo a desarrollar en el futuro. c) Como estudio comparativo entre otras poblaciones. En el Capitulo I, expongo brevemente, los fundamentos teóricos sobre el estudio de la medida y evaluación de la aptitud física, pues lo considero imprescindible para un buen enfoque del trabajo en general. El Capitulo II, se refiere a la metodología empleada: determinación de la muestra, justificación de la batería de pruebas empleada, instrumentos de medida y técnicas de aplicación. Los resultados de las medidas obtenidas, los hemos elaborado estadísticamente con los siguientes criterios: 1) trabajar con datos agrupados. 2) la tabulación, la hemos realizado formando el mayor número de intervalos posible, al objeto de únicamente confeccionar una tabla de frecuencias para cada prueba en las cuatro edades. Las medidas estadísticas que hemos obtenido han sido: Medidas de tendencia central (media); Medidas de dispersión (desviación típica); Al objeto de que los resultados estén más claros, hemos realizado las gráficas de distribución de frecuencias, para cada prueba y edad. En el Capitulo IV, hacemos un análisis de los resultados obtenidos por prueba y edad, al mismo tiempo que los compara con datos correspondientes a niños de las mismas edades de muestras obtenidas en otros países.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Pseudo-Dynamic Test Method (PDTM) is being developped currently as an alternative to the shaking table testing of large size models. However, the stepped slow execution of the former type of test has been found to be the source of important errors arising from the stress relaxation. A new continuous test method, wich allows the selection of a suitable time-scale factor in the response in order to control these errors, es proposed here. Such scaled-time response is theoretically obtained by simply augmenting the mass of the structure for wich some practical solutions are proposed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A methodology is presented to measure the fiber/matrix interface shear strength in composites. The strategy is based on performing a fiber push-in test at the central fiber of highly-packed fiber clusters with hexagonal symmetry which are often found in unidirectional composites with a high volume fraction of fibers. The mechanics of this test was analyzed in detail by means of three-dimensional finite element simulations. In particular, the influence of different parameters (interface shear strength, toughness and friction as well as fiber longitudinal elastic modulus and curing stresses) on the critical load at the onset of debonding was established. From the results of the numerical simulations, a simple relationship between the critical load and the interface shear strength is proposed. The methodology was validated in an unidirectional C/epoxy composite and the advantages and limitations of the proposed methodology are indicated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Specific tests to assess reliability of high luminosity AlInGaP LED for outdoor applications are needed. In this paper tests to propose a model involving three parameters: temperature, humidity and current have been carried out. Temperature, humidity and current accelerated model has been proposed to evaluate the reliability of this type of LED. Degradation and catastrophic failure mechanisms have been analyzed. Finally we analyze the effect of serial resistance in power luminosity degradation.