7 resultados para Office equipment and supplies

em Universidad Politécnica de Madrid


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Actual system performance of a PV system can differ from its expected behaviour.. This is the main reason why the performance of PV systems should be monitored, analyzed and, if needed, improved on. Some of the current testing procedures relating to the electrical behaviour of PV systems are appropriated for detecting electrical performance losses, but they are not well-suited to reveal hidden defects in the modules of PV plants and BIPV, which can lead to future losses. This paper reports on the tests and procedures used to evaluate the performance of PV systems, and especially on a novel procedure for quick on-site measurements and defect recognition caused by overheating in PV modules located in operating PV installations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Information Technologies are complex and this is true even in the smallest piece of equipment. But this kind of complexity is nothing comparejwith the one that arises when this technology interact with society. Office Automation has been traditionally considered as a technical field but there is no way to find solutions from a technical point of view when the problems are primarily social in their origin. Technology management has to change its focus from a pure technical perspective to a sociotechnical point of view. To facilitate this change, we propose a model that allows a better understanding between the managerial and the technical world, offering a coherent, complete and integrated perspective of both. The base for this model is an unfolding of the complexity found in information Technologies and a matching of these complexities with several levels considered within the Office, Office Automation and Human Factors dimensions. Each one of these domains is studied trough a set of distinctions that create a new and powerful understanding of its reality. Using this model we build up a map of Office Automation to be use^not only by managers but also by technicians because the primaty advantage of such a framework is that it allows a comprehensive evaluation of technology without requhing extensive technical knowledge. Thus, the model can be seen as principle for design and diagnosis of Office Automation and as a common reference for managers and specialist avoiding the severe limitations arising from the language used by the last

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Office automation is one of the fields where the complexity related with technologies and working environments can be best shown. This is the starting point we have chosen to build up a theoretical model that shows us a scene quite different from the one traditionally considered. Through the development of the model, the levels of complexity associated with office automation and office environments have been identified, establishing a relationship between them. Thus, the model allows to state a general principle for sociotechnical design of office automation systems, comprising the ontological distinctions needed to properly evaluate each particular technology and its virtual contribution to office automation. From this fact comes the model's taxonomic ability to draw a global perspective of the state-of-art in office automation technologies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Radar technologies have been developed to improve the efficiency when detecting targets. Radar is a system composed by several devices connected and working together. Depending on the type of radar, the improvements are focused on different functionalities of the radar. One of the most important devices composing a radar is the antenna, that sends the radio-frequency signal to the space in order to detect targets. This project is focused on a specific type of radar called phased array radar. This type of radar is characterized by its antenna, which consist on a linear array of radiating elements, in this particular case, eight dipoles working at the frequency band S. The main advantage introduced by the phased array antenna is that using the fundamentals of arrays, the directivity of the antenna can change by shifting the phase of the signal at the input of each radiating element. This can be done using phase shifters. Phase shifter consists on a device which produces a phase shift in the radio-frequency input signal depending on a control DC voltage. Using a phased array antenna allows changing the directivity of the antenna without a mechanical rotating system. The objective of this project is to design the feed network and the bias network of the phased antenna. The feed network consists on a parallel-fed network composed by power dividers that sends the radio-frequency signal from the source to each radiating element of the antenna. The bias network consists on a system that generates the control DC voltages supplied to the phase shifters in order to change the directivity. The architecture of the bias network is composed by a software, implemented in Matlab and run in a laptop which is connected to a micro-controller by a serial communication port. The software calculates the control DC voltages needed to obtain a determined directivity or scan angle. These values are sent by the serial communication port to the micro-controller as data. Then the micro-controller generates the desired control DC voltages and supplies them to the phase shifters. In this project two solutions for bias network are designed. Each one is tested and final conclusions are obtained to determine the advantages and disadvantages. Finally a graphic user interface is developed in order to make the system easy to use. RESUMEN. Las tecnologías empleadas por lo dispositivos radar se han ido desarrollando para mejorar su eficiencia y usabilidad. Un radar es un sistema formado por varios subsistemas conectados entre sí. Por lo que dependiendo del tipo de radar las mejoras se centran en los subsistemas correspondientes. Uno de los elementos más importantes de un radar es la antena. Esta se emplea para enviar la señal de radiofrecuencia al espacio y así poder detectar los posibles obstáculos del entorno. Este proyecto se centra en un tipo específico de radar llamado phased array radar. Este tipo de radar se caracteriza por la antena que es un array de antenas, en concreto para este proyecto se trata de un array lineal de ocho dipolos en la banda de frequencia S. El uso de una antena de tipo phased array supone una ventaja importante. Empleando los fundamentos de radiación aplicado a array de antenas se obtiene que la directividad de la antena puede ser modificada. Esto se consigue aplicando distintos desfasajes a la señal de radiofrecuencia que alimenta a cada elemento del array. Para aplicar los desfasajes se emplea un desplazador de fase, este dispositivo aplica una diferencia de fase a su salida con respecto a la señal de entrada dependiendo de una tensión continua de control. Por tanto el empleo de una antena de tipo phased array supone una gran ventaja puesto que no se necesita un sistema de rotación para cambiar la directividad de la antena. El objetivo principal del proyecto consiste en el diseño de la red de alimentación y la red de polarización de la antena de tipo phased array. La red de alimentación consiste en un circuito pasivo que permite alimentar a cada elemento del array con la misma cantidad de señal. Dicha red estará formada por divisores de potencia pasivos y su configuración será en paralelo. Por otro lado la red de polarización consiste en el diseño de un sistema automático que permite cambiar la directividad de la antena. Este sistema consiste en un programa en Matlab que es ejecutado en un ordenador conectado a un micro-controlador mediante una comunicación serie. El funcionamiento se basa en calcular las tensiones continuas de control, que necesitan los desplazadores de fase, mediante un programa en Matlab y enviarlos como datos al micro-controlador. Dicho micro-controlador genera las tensiones de control deseadas y las proporciona a cada desplazador de fase, obteniendo así la directividad deseada. Debido al amplio abanico de posibilidades, se obtienen dos soluciones que son sometidas a pruebas. Se obtienen las ventajas y desventajas de cada una. Finalmente se implementa una interfaz gráfica de usuario con el objetivo de hacer dicho sistema manejable y entendible para cualquier usuario.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Good results evaluating material properties using non-destructive testing (NDT) techniques have been achieved for decades. Several studies to understand the influence of temperature and moisture content on NDT have concluded different effects. In this study, NDT parameters were measured on the principal structural Spanish sawn timber species, Scots pine (Pinus sylvestris L.). NDT were conducted on 216 specimens of nominal dimensions 20 by 20 by 400 mm. Specimens were divided into several groups and studied at six different temperatures and four different moisture contents. Commercial equipment and techniques applied were Sylvatest Duo (ultrasonic wave technique), Steinkamp BPV (ultrasonic wave technique), and Grindo Sonic Mk5 "Industrial" (vibration analysis technique). Differences in NDT values within specimens at different temperatures and moisture contents were obtained. Main results of this study and relationships that describe changes in NDT values by effect of temperature and moisture content are presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

When the fresh fruit reaches the final markets from the suppliers, its quality is not always as good as it should, either because it has been mishandled during transportation or because it lacks an adequate quality control at the producer level, before being shipped. This is why it is necessary for the final markets to establish their own quality assessment system if they want to ensure to their customers the quality they want to sell. In this work, a system to control fruit quality at the last level of the distribution channel has been designed. The system combines rapid control techniques with laboratory equipment and statistical sampling protocols, to obtain a dynamic, objective process, which can substitute advantageously the quality control inspections carried out visually by human experts at the reception platform of most hypermarkets. Portable measuring equipment have been chosen (firmness tester, temperature and humidity sensors...) as well as easy-to-use laboratory equipment (texturometer, colorimeter, refractometer..,) combining them to control the most important fruit quality parameters (firmness, colour, sugars, acids). A complete computer network has been designed to control all the processes and store the collected data in real time, and to perform the computations. The sampling methods have been also defined to guarantee the confidence of the results. Some of the advantages of a quality assessment system as the proposed one are: the minimisation of human subjectivity, the ability to use modern measuring techniques, and the possibility of using it also as a supplier's quality control system. It can be also a way to clarify the quality limits of fruits among members of the commercial channel, as well as the first step in the standardisation of quality control procedures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Los Centros de Datos se encuentran actualmente en cualquier sector de la economía mundial. Están compuestos por miles de servidores, dando servicio a los usuarios de forma global, las 24 horas del día y los 365 días del año. Durante los últimos años, las aplicaciones del ámbito de la e-Ciencia, como la e-Salud o las Ciudades Inteligentes han experimentado un desarrollo muy significativo. La necesidad de manejar de forma eficiente las necesidades de cómputo de aplicaciones de nueva generación, junto con la creciente demanda de recursos en aplicaciones tradicionales, han facilitado el rápido crecimiento y la proliferación de los Centros de Datos. El principal inconveniente de este aumento de capacidad ha sido el rápido y dramático incremento del consumo energético de estas infraestructuras. En 2010, la factura eléctrica de los Centros de Datos representaba el 1.3% del consumo eléctrico mundial. Sólo en el año 2012, el consumo de potencia de los Centros de Datos creció un 63%, alcanzando los 38GW. En 2013 se estimó un crecimiento de otro 17%, hasta llegar a los 43GW. Además, los Centros de Datos son responsables de más del 2% del total de emisiones de dióxido de carbono a la atmósfera. Esta tesis doctoral se enfrenta al problema energético proponiendo técnicas proactivas y reactivas conscientes de la temperatura y de la energía, que contribuyen a tener Centros de Datos más eficientes. Este trabajo desarrolla modelos de energía y utiliza el conocimiento sobre la demanda energética de la carga de trabajo a ejecutar y de los recursos de computación y refrigeración del Centro de Datos para optimizar el consumo. Además, los Centros de Datos son considerados como un elemento crucial dentro del marco de la aplicación ejecutada, optimizando no sólo el consumo del Centro de Datos sino el consumo energético global de la aplicación. Los principales componentes del consumo en los Centros de Datos son la potencia de computación utilizada por los equipos de IT, y la refrigeración necesaria para mantener los servidores dentro de un rango de temperatura de trabajo que asegure su correcto funcionamiento. Debido a la relación cúbica entre la velocidad de los ventiladores y el consumo de los mismos, las soluciones basadas en el sobre-aprovisionamiento de aire frío al servidor generalmente tienen como resultado ineficiencias energéticas. Por otro lado, temperaturas más elevadas en el procesador llevan a un consumo de fugas mayor, debido a la relación exponencial del consumo de fugas con la temperatura. Además, las características de la carga de trabajo y las políticas de asignación de recursos tienen un impacto importante en los balances entre corriente de fugas y consumo de refrigeración. La primera gran contribución de este trabajo es el desarrollo de modelos de potencia y temperatura que permiten describes estos balances entre corriente de fugas y refrigeración; así como la propuesta de estrategias para minimizar el consumo del servidor por medio de la asignación conjunta de refrigeración y carga desde una perspectiva multivariable. Cuando escalamos a nivel del Centro de Datos, observamos un comportamiento similar en términos del balance entre corrientes de fugas y refrigeración. Conforme aumenta la temperatura de la sala, mejora la eficiencia de la refrigeración. Sin embargo, este incremente de la temperatura de sala provoca un aumento en la temperatura de la CPU y, por tanto, también del consumo de fugas. Además, la dinámica de la sala tiene un comportamiento muy desigual, no equilibrado, debido a la asignación de carga y a la heterogeneidad en el equipamiento de IT. La segunda contribución de esta tesis es la propuesta de técnicas de asigación conscientes de la temperatura y heterogeneidad que permiten optimizar conjuntamente la asignación de tareas y refrigeración a los servidores. Estas estrategias necesitan estar respaldadas por modelos flexibles, que puedan trabajar en tiempo real, para describir el sistema desde un nivel de abstracción alto. Dentro del ámbito de las aplicaciones de nueva generación, las decisiones tomadas en el nivel de aplicación pueden tener un impacto dramático en el consumo energético de niveles de abstracción menores, como por ejemplo, en el Centro de Datos. Es importante considerar las relaciones entre todos los agentes computacionales implicados en el problema, de forma que puedan cooperar para conseguir el objetivo común de reducir el coste energético global del sistema. La tercera contribución de esta tesis es el desarrollo de optimizaciones energéticas para la aplicación global por medio de la evaluación de los costes de ejecutar parte del procesado necesario en otros niveles de abstracción, que van desde los nodos hasta el Centro de Datos, por medio de técnicas de balanceo de carga. Como resumen, el trabajo presentado en esta tesis lleva a cabo contribuciones en el modelado y optimización consciente del consumo por fugas y la refrigeración de servidores; el modelado de los Centros de Datos y el desarrollo de políticas de asignación conscientes de la heterogeneidad; y desarrolla mecanismos para la optimización energética de aplicaciones de nueva generación desde varios niveles de abstracción. ABSTRACT Data centers are easily found in every sector of the worldwide economy. They consist of tens of thousands of servers, serving millions of users globally and 24-7. In the last years, e-Science applications such e-Health or Smart Cities have experienced a significant development. The need to deal efficiently with the computational needs of next-generation applications together with the increasing demand for higher resources in traditional applications has facilitated the rapid proliferation and growing of data centers. A drawback to this capacity growth has been the rapid increase of the energy consumption of these facilities. In 2010, data center electricity represented 1.3% of all the electricity use in the world. In year 2012 alone, global data center power demand grew 63% to 38GW. A further rise of 17% to 43GW was estimated in 2013. Moreover, data centers are responsible for more than 2% of total carbon dioxide emissions. This PhD Thesis addresses the energy challenge by proposing proactive and reactive thermal and energy-aware optimization techniques that contribute to place data centers on a more scalable curve. This work develops energy models and uses the knowledge about the energy demand of the workload to be executed and the computational and cooling resources available at data center to optimize energy consumption. Moreover, data centers are considered as a crucial element within their application framework, optimizing not only the energy consumption of the facility, but the global energy consumption of the application. The main contributors to the energy consumption in a data center are the computing power drawn by IT equipment and the cooling power needed to keep the servers within a certain temperature range that ensures safe operation. Because of the cubic relation of fan power with fan speed, solutions based on over-provisioning cold air into the server usually lead to inefficiencies. On the other hand, higher chip temperatures lead to higher leakage power because of the exponential dependence of leakage on temperature. Moreover, workload characteristics as well as allocation policies also have an important impact on the leakage-cooling tradeoffs. The first key contribution of this work is the development of power and temperature models that accurately describe the leakage-cooling tradeoffs at the server level, and the proposal of strategies to minimize server energy via joint cooling and workload management from a multivariate perspective. When scaling to the data center level, a similar behavior in terms of leakage-temperature tradeoffs can be observed. As room temperature raises, the efficiency of data room cooling units improves. However, as we increase room temperature, CPU temperature raises and so does leakage power. Moreover, the thermal dynamics of a data room exhibit unbalanced patterns due to both the workload allocation and the heterogeneity of computing equipment. The second main contribution is the proposal of thermal- and heterogeneity-aware workload management techniques that jointly optimize the allocation of computation and cooling to servers. These strategies need to be backed up by flexible room level models, able to work on runtime, that describe the system from a high level perspective. Within the framework of next-generation applications, decisions taken at this scope can have a dramatical impact on the energy consumption of lower abstraction levels, i.e. the data center facility. It is important to consider the relationships between all the computational agents involved in the problem, so that they can cooperate to achieve the common goal of reducing energy in the overall system. The third main contribution is the energy optimization of the overall application by evaluating the energy costs of performing part of the processing in any of the different abstraction layers, from the node to the data center, via workload management and off-loading techniques. In summary, the work presented in this PhD Thesis, makes contributions on leakage and cooling aware server modeling and optimization, data center thermal modeling and heterogeneityaware data center resource allocation, and develops mechanisms for the energy optimization for next-generation applications from a multi-layer perspective.