46 resultados para GENERATORS

em Universidad Politécnica de Madrid


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The increasing penetration of wind energy into power systems has pushed grid operators to set new requirements for this kind of generating plants in order to keep acceptable and reliable operation of the system. In addition to the low voltage ride through capability, wind farms are required to participate in voltage support, stability enhancement and power quality improvement. This paper presents a solution for wind farms with fixed-speed generators based on the use of STATCOM with braking resistor and additional series impedances, with an adequate control strategy. The focus is put on guaranteeing the grid code compliance when the wind farm faces an extensive series of grid disturbances.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Among all the different types of electric wind generators, those that are based on doubly fed induction generators, or DFIG technology, are the most vulnerable to grid faults such as voltage sags. This paper proposes a new control strategy for this type of wind generator, that allows these devices to withstand the effects of a voltage sag while following the new requirements imposed by grid operators. This new control strategy makes the use of complementary devices such as crowbars unnecessary, as it greatly reduces the value of currents originated by the fault. This ensures less costly designs for the rotor systems as well as a more economic sizing of the necessary power electronics. The strategy described here uses an electric generator model based on space-phasor theory that provides a direct control over the position of the rotor magnetic flux. Controlling the rotor magnetic flux has a direct influence on the rest of the electrical variables enabling the machine to evolve to a desired work point during the transient imposed by the grid disturbance. Simulation studies have been carried out, as well as test bench trials, in order to prove the viability and functionality of the proposed control strategy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In weak grids, an important problem with voltage stability and protections coordination of power plants exists. This problem appears because all the generation groups are connected to the same bus bar. As a result, if a fault occurs in any of the generation groups, or in the bus bar that connect them, the system voltage will have large oscillations. Hence, in weak grids the correct adjustment of AVR (Automatic Voltage Regulator) is critical. In this work an experimental study of differents AVR adjustments against fault in weak grids is described.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Locating stator-winding ground faults accurately is a very difficult task. In this paper the grounding circuit measurements are evaluated in order to obtain information about the stator ground-fault location in synchronous generators. In power generators grounded through a high impedance, the relation between the neutral voltage and the phase voltage provide a first estimation of the fault location. The location error by using this ratio depends on the fault resistance and the value of the capacitance to ground of the stator winding. However, the error added by ignoring the value of the fault resistance is the most relevant term. This location estimation and the location error have been evaluated through the data of a real synchronous machine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The generator differential protection is one of the most important electrical protections of synchronous generator stator windings. Its operation principle is based on the comparison of the input current and output current at each phase winding. Unwanted trip commands are usually caused by CT saturation, wrong CT selection, or the fact that they may come from different manufacturers. In generators grounded through high impedance, only phase-to-phase or three-phase faults can be detected by the differential protection. This kind of fault causes differential current to flow in, at least, two phases of the winding. Several cases of unwanted trip commands caused by the appearance of differential current in only one phase of the generator have been reported. In this paper multi-phase criterion is proposed for generator differential protection algorithm when applied to high impedance grounded generators.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The search for new energy models arises as a necessity to have a sustainable power supply. The inclusion of distributed generation sources (DG) allows to reduce the cost of facilities, increase the security of the grid or alleviate problems of congestion through the redistribution of power flows. In remote microgrids it is needed in a particular way a safe and reliable supply, which can cover the demand for a low cost; due to this, distributed generation is an alternative that is being widely introduced in these grids. But the remote microgrids are especially weak grids because of their small size, low voltage level, reduced network mesh and distribution lines with a high ratio R/X. This ratio affects the coupling between grid voltages and phase shifts, and stability becomes an issue of greater importance than in interconnected systems. To ensure the appropriate behavior of generation sources inserted in remote microgrids -and, in general, any electrical equipment-, it is essential to have devices for testing and certification. These devices must, not only faithfully reproduce disturbances occurring in remote microgrids, but also to behave against the equipment under test (EUT) as a real weak grid. This also makes the device commercially competitive. To meet these objectives and based on the aforementioned, it has been designed, built and tested a voltage disturbances generator, in order to provide a simple, versatile, full and easily scalable device to manufacturers and laboratories in the sector.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Offshore wind farms are beginning to form part of coastal and marine landscapes located in dynamic surroundings. An integral management model must therefore be applied to achieve not only technical and economic viability of the project but also respect for the environment. Amongst other aspects, the latter calls for an analysis of the possible impact these facilities may have on littoral processes and this requires the differences between littoral processes prior and subsequent to the facility’s construction to be known. The maritime climate, the composition of the coast, lay-out distribution and characteristics of the facility’s components need to be known, particularly foundations as they are the main obstacles waves and currents meet. This article first addresses different aspects related to an offshore wind farm’s influence on the analysis of how it affects littoral dynamics and, because of their importance in this study, pays special attention to foundations. Coastal erosion due to this type of facility is then examined. The main conclusion of this article is that, whilst there are certain opinions claiming the coast is not affected by the presence of this kind of facility since the distance from location to coast and between wind turbine generators themselves is long, the impact must be analysed in each specific case, at least until experience proves otherwise and criteria are adopted in this respect.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article analyses the long-term performance of collective off-grid photovoltaic (PV) systems in rural areas. The use of collective PV systems for the electrification of small medium-size villages in developing countries has increased in the recent years. They are basically set up as stand-alone installations (diesel hybrid or pure PV) with no connection with other electrical grids. Their particular conditions (isolated) and usual installation places (far from commercial/industrial centers) require an autonomous and reliable technology. Different but related factors affect their performance and the energy supply; some of them are strictly technical but others depend on external issues like the solar energy resource and users’ energy and power consumption. The work presented is based on field operation of twelve collective PV installations supplying the electricity to off-grid villages located in the province of Jujuy, Argentina. Five of them have PV generators as unique power source while other seven include the support of diesel groups. Load demand evolution, energy productivity and fuel consumption are analyzed. Besides, energy generation strategies (PV/diesel) are also discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The main objective of this paper is to review the state of the art of residential PV systems in Belgium by the analysis of the operational data of 993 installations. For that, three main questions are posed: how much energy do they produce? What level of performance is associated to their production? Which are the key parameters that most influence their quality? This work brings answers to these questions. A middling commercial PV system, optimally oriented, produces a mean annual energy of 892 kWh/kWp. As a whole, the orientation of PV generators causes energy productions to be some 6% inferior to optimally oriented PV systems. The mean performance ratio is 78% and the mean performance index is 85%. That is to say, the energy produced by a typical PV system in Belgium is 15% inferior to the energy produced by a very high quality PV system. Finally, on average, the real power of the PV modules falls 5% below its corresponding nominal power announced on the manufacturer's datasheet. Differences between real and nominal power of up to 16% have been detected.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The main objective of this paper is to review the state of the art of residential PV systems in France. This is done analyzing the operational data of 6868 installations. Three main questions are posed. How much energy do they produce? What level of performance is associated to their production? Which are the key parameters that most influence their quality? During the year 2010, the PV systems in France have produced a mean annual energy of 1163 kWh/kWp. As a whole, the orientation of PV generators causes energy productions to be some 7% inferior to optimally oriented PV systems. The mean Performance Ratio is 76% and the mean Performance Index is 85%. That is to say, the energy produced by a typical PV system in France is 15% inferior to the energy produced by a very high quality PV system. On average, the real power of the PV modules falls 4.9% below its corresponding nominal power announced on the manufacturer's datasheet. A brief analysis by PV modules technology has led to relevant observations about two technologies in particular. On the one hand, the PV systems equipped with heterojunction with intrinsic thin layer (HIT) modules show performances higher than average. On the other hand, the systems equipped with the copper indium (di)selenide (CIS) modules show a real power that is 16% lower than their nominal value.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The main objective of this paper is to review the state of the art of residential PV systems in France and Belgium. This is done analyzing the operational data of 10650 PV systems (9657 located in France and 993 in Belgium). Three main questions are posed. How much energy do they produce? What level of performance is associated to their production? Which are the key parameters that most influence their quality? During the year 2010, the PV systems in France have produced a mean annual energy of 1163 kWh/kWp in France and 852 kWh/kWp in Belgium. As a whole, the orientation of PV generators causes energy productions to be some 7% inferior to optimally oriented PV systems. The mean Performance Ratio is 76% in France and 78% in Belgium, and the mean Performance Index is 85% in both countries. On average, the real power of the PV modules falls 4.9% below its corresponding nominal power announced on the manufacturer?s datasheet. A brief analysis by PV modules technology has lead to relevant observations about two technologies in particular. On the one hand, the PV systems equipped with Heterojunction with Intrinsic. Thin layer (HIT) modules show performances higher than average. On the other hand, the systems equipped with Copper Indium (di)Selenide (CIS) modules show a real power that is 16 % lower than their nominal value.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work is focused on building and configuring a measurement test bench for non linear High Power Amplifiers, more precisely those ones based on the Envelope Elimination and Restoration. At first sight the test bench is composed of several arbitrary waveform generators, an oscilloscope, a vector signal generator and a spectrum analyzer all of them controlled remotely. The test bench works automatically, that is why several software control programs have been developed in order to control all this equipment. The control programs have been developed in Matlab/Octave Scripting language and at last chance in a more low level language as C. The signal processing algorithms, taking into account that the time alignment one is the most important, have been developed in Matlab/Octave Scripting too. An improvement of 10dB in the ACPR(Adjacent Channel Power Ratio) has been obtained just by applying the time alignment algorithm developed in this work

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cellular ferroelectrets exhibit interesting electromechanical- acoustical characteristics. Their recent appearance and remarkable properties open up new possibilities for the design and development of ultrasonic transducers. In particular, the feasibility of fabricating ultrasonic vortex generators using ferroelectret films is demonstrated in this work. To this end, a transducer prototype was built by gluing the material onto a tangential-helical surface (outer diameter: 40 mm, pitch: 3.45 mm). Experimental results agree well with the theoretical estimation of the pressure and phase of the acoustic field in the near field and far field, which corroborates the potential of ferroelectrets to customize special acoustic fields. Furthermore, the proposed fabrication procedure is inexpensive and represents a new alternative for exploring and analyzing the special characteristics of acoustical helical wavefronts

Relevância:

10.00% 10.00%

Publicador:

Resumo:

En la actualidad, el interés por las plantas de potencia de ciclo combinado de gas y vapor ha experimentado un notable aumento debido a su alto rendimiento, bajo coste de generación y rápida construcción. El objetivo fundamental de la tesis es profundizar en el conocimiento de esta tecnología, insuficientemente conocida hasta el momento debido al gran número de grados de libertad que existen en el diseño de este tipo de instalaciones. El estudio se realizó en varias fases. La primera consistió en analizar y estudiar las distintas tecnologías que se pueden emplear en este tipo de centrales, algunas muy recientes o en fase de investigación, como las turbinas de gas de geometría variable, las turbinas de gas refrigeradas con agua o vapor del ciclo de vapor o las calderas de paso único que trabajan con agua en condiciones supercríticas. Posteriormente se elaboraron los modelos matemáticos que permiten la simulación termodinámica de cada uno de los componentes que integran las plantas, tanto en el punto de diseño como a cargas parciales. Al mismo tiempo, se desarrolló una metodología novedosa que permite resolver el sistema de ecuaciones que resulta de la simulación de cualquier configuración posible de ciclo combinado. De esa forma se puede conocer el comportamiento de cualquier planta en cualquier punto de funcionamiento. Por último se desarrolló un modelo de atribución de costes para este tipo de centrales. Con dicho modelo, los estudios se pueden realizar no sólo desde un punto de vista termodinámico sino también termoeconómico, con lo que se pueden encontrar soluciones de compromiso entre rendimiento y coste, asignar costes de producción, determinar curvas de oferta, beneficios económicos de la planta y delimitar el rango de potencias donde la planta es rentable. El programa informático, desarrollado en paralelo con los modelos de simulación, se ha empleado para obtener resultados de forma intensiva. El estudio de los resultados permite profundizar ampliamente en el conocimiento de la tecnología y, así, desarrollar una metodología de diseño de este tipo de plantas bajo un criterio termoeconómico. ABSTRACT The growing energy demand and the need of shrinking costs have led to the design of high efficiency and quick installation power plants. The success of combined cycle gas turbine power plants lies on their high efficiency, low cost and short construction lead time. The main objective of the work is to study in detail this technology, which is not thoroughly known owing to the great number of degrees of freedom that exist in the design of this kind of power plants. The study is divided into three parts. Firstly, the different technologies and components that could be used in any configuration of a combined cycle gas turbine power plant are studied. Some of them could be of recent technology, such as the variable inlet guide vane compressors, the H-technology for gas turbine cooling or the once-through heat recovery steam generators, used with water at supercritical conditions. Secondly, a mathematical model has been developed to simulate at full and part load the components of the power plant. At the same time, a new methodology is proposed in order to solve the equation system resulting for any possible power plant configuration. Therefore, any combined cycle gas turbine could be simulated at any part load condition. Finally a themoeconomic model is proposed. This model allows studying the power plant not only from a thermodynamic point of view but also from a thermoeconomic one. Likewise, it allows determining the generating costs or the cash flow, thus achieving a trade off between efficiency and cost. Likewise, the model calculates the part load range where the power plant is profitable. Once the thermodynamic and thermoeconomic models are developed, they are intensively used in order to gain knowledge in the combined cycle gas turbine technology and, in this way, to propose a methodology aimed at the design of this kind of power plants from a thermoeconomic point of view.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RESUMEN Los procesos de diseño de zonas o diseño del territorio implican la partición de un espacio geográfico, organizado en un conjunto de unidades de área, en diferentes regiones o zonas según un conjunto especifico de criterios que varían en función del campo de aplicación. En la mayoría de los casos, el objetivo fundamental consiste en crear zonas de tamaño aproximadamente igual respecto a uno o varios atributos de medida -de carácter cuantitativo- (zonas con igual número de habitantes, igual promedio de ventas...). Sin embargo, están apareciendo nuevas aplicaciones, algunas en el contexto de las políticas de desarrollo sostenible, cuya finalidad es la definición de regiones con un tamaño predeterminado, no necesariamente similar. Además, en estos casos las zonas han de formarse en torno a un conjunto específico de posiciones, semillas o generadores. Este tipo de particiones no han sido lo suficientemente investigadas, de manera que no se conocen modelos de solución para la delimitación automática de las zonas. En esta tesis se ha diseñado un nuevo método basado en una versión discreta del diagrama de Voronoi con peso aditivo adaptativo (DVPAA), que permite la partición de un espacio bidimensional en zonas de un tamaño específico, considerando tanto la posición como el peso de cada uno de los generadores. El método consiste en resolver repetidamente un tradicional diagrama de Voronoi con peso aditivo, de forma que los pesos de cada generador se actualizan en cada iteración. En el proceso de cálculo de distancias se usa una métrica basada en el camino más corto, lo que garantiza que la partición obtenida esté formada por un conjunto de zonas conexas. La heurística diseñada se integra en una aplicación prototipo, desarrollada en un entorno SIG (Sistemas de Información Geográfica), que permite el trazado automático de zonas según los criterios anteriormente expuestos. Para analizar la viabilidad del método se ha utilizado como caso de estudio la gestión de los recursos pastorales para la ganadería extensiva en tres municipios de Castilla-La Mancha. Las pruebas realizadas ponen de manifiesto que la heurística diseñada, adaptada a los criterios que se plantean en el contexto de la gestión de sistemas extensivos agropecuarios, es válida para resolver este tipo de problemas de partición. El método propuesto se caracteriza por su eficacia en el tratamiento de un gran número de unidades superficiales en formato vectorial, generando soluciones que convergen con relativa rapidez y verifican los criterios establecidos. En el caso estudiado, aunque la posición prefijada de los generadores reduce considerablemente la complejidad del problema, existen algunas configuraciones espaciales de estos elementos para las que el algoritmo no encuentra una solución satisfactoria, poniéndose de manifiesto una de las limitaciones de este modelo. Tal y como se ha podido comprobar, la localización de los generadores puede tener un considerable impacto en la zonificación resultante, por lo que, de acuerdo con Kalcsics et al. (2005), una selección "inadecuada" difícilmente puede generar regiones válidas que verifiquen los criterios establecidos. ABSTRACT Tenitory or zone design processes entail partitioning a geographic space, organized as a set of basic areal units, into different regions or zones according to a specific set of entena that are dependent on the application context. In most cases the aim is to create zones that have approximately equal sizes with respect to one or several measure attributes (zones with equal numbers of inhabitants, same average sales, etc). However, some of the new applications that have emerged, particularly in the context of sustainable development policies, are aimed at defining zones of a predetermined, though not necessarily similar, size. In addition, the zones should be built around a given set of positions, seeds or generators. This type of partitioning has not been sufñciently researched; therefore there are no known approaches for automated zone delimitation. This thesis proposes a new method based on a discrete versión of the Adaptive Additively Weighted Voronoi Diagram (AAWVD) that makes it possible to partition a 2D space into zones of specific sizes, taking both the position and the weight of each (seed) generator into account. The method consists of repeatedly solving a traditional additively weighted Voronoi diagram, so that the weights of each generator are updated at every iteration. The partition s zones are geographically connected nsing a metric based 011 the shortest path. The proposed heuristic lias been included in an application, developed in a GIS environment that allows the automated zone delimitation according to the mentioned criteria. The management of the extensive farming system of three municipalities of Castilla-La Mancha (Spain) has been used as study case to analyze the viability of the method. The tests carried out have established that the proposed method, adapted to the criteria of this application field, is valid for solving this type of partition problem. The applied algorithm is capable of handling a high number of vector areal units, generating solutions that converge in a reasonable CPU time and comply with the imposed constraints. Although the complexity of this problem is greatly reduced when the generator's positions are fixed, in many cases, these positions impose a spatial confignration that the algorithm proposed is unable to solve, thus revealing one of the limitations of this method. It has been shown that the location of the generators has a considerable impact on the final solution, so that, as Kalcsics et al. (2005) observed, an "inadequate" selection can hardly generate valid zones that comply with the established criteria.