19 resultados para Floors

em Universidad Politécnica de Madrid


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The technique of reinforcement of wooden floors is a matter clearly multidisciplinary. The teaching of the subject using the "traditional" method, explaining the theory first and then proposing and solving problems has not been successful. This paper discusses the results of a teaching experiencie. It has been the teaching of the subject by the case method. The results are clearly superior to those obtained with the traditional methodology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

One of the common pathologies of brickwork masonry structural elements and walls is the cracking associated with the differential settlements and/or excessive deflections of the slabs along the life of the structure. The scarce capacity of the masonry in order to accompany the structural elements that surround it, such as floors, beams or foundations, in their movements makes the brickwork masonry to be an element that frequently presents this kind of problem. This problem is a fracture problem, where the wall is cracked under mixed mode fracture: tensile and shear stresses combination, under static loading. Consequently, it is necessary to advance in the simulation and prediction of brickwork masonry mechanical behaviour under tensile and shear loading. The quasi-brittle behaviour of the brickwork masonry can be studied using the cohesive crack model whose application to other quasibrittle materials like concrete has traditionally provided very satisfactory results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Knowledge of the uncertainty of measurement of testing results is important when results have to be compared with limits and specifications. In the measurement of sound insulation following standards UNE EN ISO 140-4 the uncertainty of the final magnitude is mainly associated to the average sound pressure levels L1 and L2 measured. A parameter that allows us to quantify the spatial variation of the sound pressure level is the standard deviation of the pressure levels measured at different points of the room. In this work, for a wide number of measurements following standards UNE EN ISO 140-4 we analyzed qualitatively the behaviour of the standard deviation for L1 and L2. The study of sound fields in enclosed spaces is very difficult. There are a wide variety of rooms with different sound fields depending on factors as volume, geometry and materials. In general, we observe that the L1 and L2 standard deviations contain peaks and dips independent on characteristics of the rooms at single frequencies that could correspond to critical frequencies of walls, floors and windows or even to temporal alterations of the sound field. Also, in most measurements according to UNE EN ISO 140-4 a large similitude between L1 and L2 standard deviation is found. We believe that such result points to a coupled system between source and receiving rooms, mainly at low frequencies the shape of the L1 and L2 standard deviations is comparable to the velocity level standard deviation on a wall

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El proyecto tiene como objetivo realizar el diseño de la cimentación de Torre Reforma. Torre Reforma se ubica en Av. Paseo de la Reforma No. 483, en la esquina con Rio Elba, en la ciudad de México. Dicha ubicación geotécnicamente corresponde a lo que se conoce como la Zona de Lago. La superficie construida será de 2780 m2 y el edificio contará con una altura de 244 m y un total de 57 plantas. Por debajo del nivel de calle el edificio constará de 10 niveles de sótano destinados a aparcamiento. Partiendo de los parámetros geotécnicos del terreno, el proyecto consistirá en calcular una parte de la cimentación empleada en este edificio. Este proyecto se podrá utilizar como guía para realizar cimentaciones parecidas para otros edificios. ABSTRACT The objective of this Project is to make the design of the foundation of Torre Reforma. Torre Reforma is located in Av. Paseo de la Reforma No. 483, on the corner with Río Elba in México City. Geotechnically this location corresponds to what it is known as “la Zona del Lago” or Lake Zone. The constructed area is of 2780 m2 and the building will have a height of 244 m and a total of 57 floors. Below street level the building will include ten basement levels for parking. Based on the geotechnical parameters of the site, the project will consist in calculating a part of the foundation used in this building. This project will be able to be used as a guide for future projects of foundations of buildings in similar conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Esta Tesis plantea la pregunta de si el uso de morteros con parafinas microencapsuladas combinado con colectores solares térmicos puede reducir el consumo de energías convencionales, en un sistema tradicional de suelo radiante. Se pretende contribuir al conocimiento acerca del efecto que produce en el edificio, el calor latente acumulado en suelos radiantes, utilizando morteros de cemento Portland con material de cambio de fase (PCM), en conjunto con la energía solar. Para cumplir con este propósito, la investigación se desarrolla considerando diversos aspectos. En primer lugar, se revisa y analiza la documentación disponible en la actualidad, de almacenamiento de energía mediante calor latente en la construcción, y en particular la aplicación de microcápsulas de PCM en morteros y suelos radiantes. También se revisa la documentación relacionada con la aplicación de la energía solar térmica y en suelo radiante. Se analiza la normativa vigente respecto al material, a los colectores solares y al suelo radiante. Se verifica que no hay normativa relacionada con mortero-PCM, debido a esto se aplica en la investigación una adaptación de la existente. La fase experimental desarrollada esta principalmente dirigida a la cuantificación, caracterización y evaluación de las propiedades físicas, mecánicas y térmicas del mortero de cemento Portland con parafinas microencapsuladas. Los resultados obtenidos y su análisis, permiten conocer el comportamiento de este tipo de morteros, con las diferentes variables aplicadas en la investigación. Además, permite disponer de la información necesaria, para crear una metodología para el diseño de morteros con parafina microencapsulada, tanto del punto de vista de su resistencia a la compresión y contenido de PCM, como de su comportamiento térmico como acumulador de calor. Esto se logra procesando la información obtenida y generando modelos matemáticos, para dosificar mezclas, y predecir la acumulación de calor en función de su composición. Se determinan los tipos y cantidades de PCM, y el cemento más adecuado. Se obtienen importantes conclusiones respecto a los aspectos constructivos a considerar en la aplicación de morteros con PCM, en suelo radiante. Se analiza y evalúa la demanda térmica que se puede cubrir con el suelo radiante, utilizando morteros con parafina microencapsulada, a través de la acumulación de energía solar producida por colectores solares, para condiciones climáticas, técnicas y tipologías constructivas específicas. Se determina que cuando los paneles cubren más de 60 % de la demanda por calefacción, se puede almacenar en los morteros con PCM, el excedente generado durante el día. Se puede cubrir la demanda de acumulación de energía con los morteros con PCM, en la mayoría de los casos analizados. Con esto, se determina que el uso de morteros con PCM, aporta a la eficiencia energética de los edificios, disminuyendo el consumo de energías convencionales, reemplazándola por energía solar térmica. En esta investigación, el énfasis está en las propiedades del material mortero de cemento-PCM y en poder generar metodologías que faciliten su uso. Se aborda el uso de la energía solar, para verificar que es posible su acumulación en morteros con PCM aplicados en suelo radiante, posibilitando el reemplazo de energías convencionales. Quedan algunos aspectos de la aplicación de energía solar a suelo radiante con morteros con PCM, que no han sido tratados con la profundidad que requieren, y que resultan interesantes de evaluar en este tipo de aplicaciones constructivas, como entre otros, los relacionados con la cuantificación de los ahorros de energía en las diferentes estaciones del año, de la estabilización de temperaturas internas, su análisis de costo y la optimización de este tipo de sistemas para utilización en verano, los que dan pie para otras Tesis o proyectos de investigación. ABSTRACT This Thesis proposes the question of whether the use of mortars with microencapsulated paraffin combined with solar thermal collectors can reduce conventional energy consumption in a traditional heating floor system. It aims to contribute to knowledge about the effect that it has on the building, the latent heat accumulated in heating floor, using Portland cement mortars with phase change material (PCM), in conjunction with solar energy. To fulfill this purpose, the research develops it considering various aspects. First, it reviews and analyzes the documentation available today, about energy storage by latent heat in the building, and in particular the application of PCM microcapsules in mortars and heating floors. It also reviews the documentation related to the application of solar thermal energy and heating floor. Additionally, it analyzes the current regulations regarding to material, solar collectors and heating floors. It verifies that there aren’t regulations related to PCM mortar, due to this, it applies an adaptation in the investigation. The experimental phase is aimed to the quantification, mainly, characterization and evaluation of physical, mechanical and thermal properties of Portland cement mortar with microencapsulated paraffin. The results and analysis, which allow us to know the behavior of this type of mortars with different variables applied in research. It also allows having the information necessary to create a methodology for designing mortars with microencapsulated paraffin, both from the standpoint of its resistance to compression and PCM content, and its thermal performance as a heat accumulator. This accomplishes by processing the information obtained, and generating mathematical models for dosing mixtures, and predicting heat accumulation depending on their composition. The research determines the kinds and amounts of PCM, and the most suitable cement. Relevant conclusions obtain it regarding constructive aspects to consider in the implementation of PCM mortars in heating floor. Also, it analyzes and evaluates the thermal demand that it can be covered in heating floor using microencapsulated paraffin mortars, through the accumulation of solar energy produced by solar collectors to weather conditions, technical and specific building typologies. It determines that if the panels cover more than 60% of the demand for heating, the surplus generated during the day can be stored in PCM mortars. It meets the demand of energy storage with PCM mortars, in most of the cases analyzed. With this, it determines that the use of PCM mortars contributes to building energy efficiency, reducing consumption of conventional energy, replacing it with solar thermal energy. In this research approaches the use of solar energy to determine that it’s possible to verify its accumulation in PCM mortars applied in heating floor, enabling the replacement of conventional energy. The emphasis is on material properties of PCM mortar and, in order to generate methodologies to facilitate their use. There are some aspects of solar energy application in PCM mortars in heating floor, which have not been discussed with the depth required, and that they are relevant to evaluate in this kind of construction applications, including among others: the applications related to the energy savings quantification in different seasons of the year, the stabilizing internal temperatures, its cost analysis and optimization of these systems for use in summer, which can give ideas for other thesis or research projects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

On Wednesday 11th May 2011 at 6:47 pm (local time) a magnitude 5.1 Mw earthquake occurred 6 km northeast of Lorca with a depth of around 2 km. As a consequence of the shallow depth and the small epicentral distance, important damage was produced in several masonry constructions and even led to the collapse of some of them. Pieces of the facades of several buildings fell down onto the sidewalk, being one of the reasons for the killing of a total of 9 people. The objective of this paper is to describe and analyze the failure patterns observed in unreinforced masonry buildings ranging from 3 to 8 floors in height. First, a brief description of the local building practices of masonry buildings is given. Then, the most important failure types of masonry buildings are described and discussed. After that, a more detailed analysis of one particular building is presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

During the last two decades the topic of human induced vibration has attracted a lot of attention among civil engineering practitioners and academics alike. Usually this type of problem may be encountered in pedestrian footbridges or floors of paperless offices. Slender designs are becoming increasingly popular, and as a consequence, the importance of paying attention to vibration serviceability also increases. This paper resumes the results obtained from measurements taken at different points of an aluminium catwalk which is 6 m in length by 0.6 m in width. Measurements were carried out when subjecting the structure to different actions:1)Static test: a steel cylinder of 35 kg was placed in the middle of the catwalk; 2)Dynamic test: this test consists of exciting the structure with singles impulses; 3)Dynamic test: people walking on the catwalk. Identification of the mechanical properties of the structure is an achievement of the paper. Indirect methods were used to estimate properties including the support stiffness, the beam bending stiffness, the mass of the structure (using Rayleigh method and iterative matrix method), the natural frequency (using the time domain and frequency domain analysis) and the damping ratio (by calculating the logarithmic decrement). Experimental results and numerical predictions for the response of an aluminium catwalk subjected to walking loads have been compared. The damping of this light weight structure depends on the amplitude of vibration which complicates the tuning of a structural model. In the light of the results obtained it seems that the used walking load model is not appropriate as the predicted transient vibration values (TTVs) are much higher than the measured ones.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este proyecto trata de completar un estudio sobre la viabilidad de una instalación de turbina de eje vertical, en una azotea de un edificio de 6 plantas en el centro de la ciudad de Madrid. Está basado en la comunidad de vecinos de la calle de Lagasca 106 de Madrid, y se realiza de forma global, con objeto de que sirva como ejemplo a futuros estudios a realizar en esta área, incluyendo todas las dificultades y problemas que este tipo de proyectos muestran en su viabilidad. Los aspectos que vamos a abordar son: Demostración de que una turbina de eje vertical es más indicada e idónea para estos casos que una turbina de eje horizontal. Capacidad de generación eléctrica de la instalación que proponemos. Problemas asociados con la actual legislación. Problemas relacionados con la instalación eléctrica: el inversor de corriente, la decisión de utilizar un sistema de baterías, conectar el aerogenerador a la red o buscar un sistema mixto. La viabilidad económica de la instalación. ABSTRACT This project tries to complete a study on the viability of a vertical axis turbines installation in the roof of a “standard” 6 floors building in the center of Madrid. Besides, the project is based on the building situated in Lagasca 106, it pretends to be done in a “global” mode, in order to be an example of future projects, and include as many usual problems and items that this kind of projects could have to afford. These problems and issues are: the substantiation of the choice of the vertical axis turbine instead of a usual horizontal axis turbine, the model and the power capacity of this turbine. The turbines installation energy saving capacity. Problems associated to the legislation that we may to afford. And problems related to the electric installation, such us, transformer associated to the turbine, the decision of link the turbine with batteries or joining it directly to the building electric system. Also we have to set a programming system in order to monitor the different situations that the turbine has to work

Relevância:

10.00% 10.00%

Publicador:

Resumo:

On Wednesday 11th May 2011 at 6:47 pm (local time) a magnitude 5.1 Mw earthquake occurred 6 km northeast of Lorca with a depth of around 5 km. As a consequence of the shallow depth and the small epicentral distance, important damage was produced in several masonry constructions and even led to the collapse of one of them. Pieces of the facades of several buildings fell down onto the sidewalk, being one of the reasons for the killing of a total of 9 people. The objective of this paper is to describe and analyze the failure patterns observed in reinforced concrete frame buildings with masonry infill walls ranging from 3 to 8 floors in height. Structural as well as non-structural masonry walls suffered important damage that led to redistributions of forces causing in some cases the failure of columns. The importance of the interaction between the structural frames and the infill panels is analyzed by means of non-linear Finite Element Models. The resulting load levels are compared with the member capacities and the changes of the mechanical properties during the seismic event are described and discussed. In the light of the results obtained the observed failure patterns are explained. Some comments are stated concerning the adequacy of the numerical models that are usually used during the design phase for the seismic analysis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El objetivo de este proyecto es realizar un estudio geotécnico para la edificación de una vivienda unifamiliar sobre un terreno expansivo en Gata de Gorgos (Alicante). El edificio consta de 3 plantas y una superficie construida de 220 mP. Se realizaron los trabajos de campo, se ensayaron en el laboratorio las muestras obtenidas y se definieron los diferentes niveles geotécnicos. Existiendo un riesgo por expansividad en uno de los niveles, se concluyo con la solución de cimentación mediante pozos, realizándose los cálculos necesarios para el posterior proyecto de la obra. ABSTRACT The object of this project is to realize a geotechnical study for the construction of a detached house over expansive terrain at Gata de Gorgos (Alicante). The building consists of three floors with a total area of 220 mP. Fieldworks were accomplished, obtained samples were tested in the laboratory and the different geotechnical levels were defined. Due to a risk of expansiveness in one of the levels, foundation solution will be done through wells. Finally, there were realized the calculations needed for the project of subsequent building.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Las piezas pretensadas de hormigón presentan zonas muy solicitadas correspondientes a la zona de transferencia. En muchos casos se ha detectado figuración en tales zonas cuyo origen está ligado a la transferencia de la fuerza de pretensado, pudiendo llegar a causar el rechazo de la pieza. En el caso de las piezas prefabricadas con armaduras pretesas adherentes, no siempre es posible disponer armado transversal para controlar esta fisuración, ya sea por el proceso constructivo, ya sea por disponer en general de secciones transversales muy optimizadas. Recientemente se desarrolló una nueva tipología de piezas de hormigón prefabricado para forjados unidireccionales pretensadas con armadura activa pretesa y sin armadura transversal. La tipología se asimila a una sección en PI invertida, con alas de gran envergadura en comparación con el ancho de nervio, y armadura activa distribuida en las alas. Este diseño parece propenso a la aparición de fisuración en el momento de la transferencia del pretensado. Así, se han producido fallos de carácter frágil: colapso de piezas ya colocadas en obra, separándose la losa inferior de los nervios y cayendo sobre el piso. Las herramientas de análisis usuales han resultado inútiles al aplicarse a la investigación de esta patología. Para afrontar el estudio de los problemas detectados en la tipología, se ha analizado el fenómeno de las tensiones de tracción en la zona de transferencia, usualmente denominadas exfoliación y estallido, así como los métodos de análisis aplicables a elementos pretesos sin armadura transversal. En algunas ocasiones se trata del resultado de trabajos desarrollados para piezas postesadas, o para calcular cuantías de armadura transversal, adaptados a posteriori. También existen métodos desarrollados específicamente para piezas pretesas sin armadura transversal. Junto a los factores considerados en los métodos existentes se han localizado otros, no tenidos en cuenta habitualmente, pero que pueden ser determinantes en piezas no convencionales, como son: la existencia de pretensado superior e inferior, la falta de simetría de la sección transversal, el ancho variable de las piezas, una relación entre el ancho del ala y el espesor de los nervios elevada, la distribución transversal del pretensado en relación al ancho variable. Además, la mayoría de los métodos se han basado en simplificaciones bidimensionales. Para tener en cuenta la influencia de estos factores, se han modelizado piezas en las que varían tanto la geometría de la sección transversal y la cuantía de pretensado, como la ley de adherencia o la distribución de armadura activa en la sección. Estos modelos se han analizado mediante el método de elementos finitos, efectuándose u análisis elástico lineal tridimensional. En general, los métodos existentes no han predicho adecuadamente las tensiones obtenidas mediante elementos finitos. Sobre los resultados obtenidos por elementos finitos se ha desarrollado un ajuste experimental, que presentan un alto grado de correlación y de significación, así como una reducida dispersión y error relativo. En consecuencia, se propone un método de obtención de la tensión máxima de exfoliación, consistente en varias ecuaciones, que tienen en cuenta las peculiaridades de la configuración de las piezas citadas y permiten considerar cualquier ley de adherencia, manteniendo la coherencia con la longitud de transmisión. Las ecuaciones se emplean para la obtención de la tensión máxima de exfoliación en piezas de la tipología estudiada cuya armadura activa se sitúe fuera del núcleo central de la sección transversal. Respecto al estallido, se propone una modificación de los métodos existentes que, comparado con los resultados del análisis por elementos finitos, mejora el valor medio y la dispersión a valores admisibles y del lado de la seguridad. El método considera la geometría de la sección y la distribución del pretensado en la losa inferior. Finalmente, se ofrecen estrategias de diseño para piezas de la tipología o semejantes. End zones of prestressed concrete members are highly stressed. Cracking have often appeared at end zone, and its beginning is related to prestress release. Some members become rejected because of these cracks. Sometimes it is not possible having transverse reinforcement in order to control cracking, when referring to pretensioned precast members. The reason may be the construction process or highly optimized crosssections. A new typology of precast concrete members designed for one-way composite floors was recently developed. The members, without transverse reinforcement, are prestressed with pretensioned wires or strands. This typology is similar to an inverted TT slab, with a large flange related to the web thickness and prestressing reinforcement spread across the flange. This design is highly susceptible to appear cracking at prestress release. Therefore, brittle failures have been reported: fail of slabs laid in place on a construction site, resulting in the separation of the flange from the webs,, and the subsequent fall on the lower floor. Usual analytical methods have been useless to study the failure. End zone tensile stresses have been analysed to study the detected typology problems. These tensile stresses are usually called spalling and bursting (also called splitting in the U.S.). Analysis methods applicable to pretensioned members without transverse reinforcement have been analysed too. Some methods were originally developed for postensioned concrete or for obtaining the amount of transverse reinforcement. In addition, there are methods developed specifically for pretensioned members without transverse reinforcement. Some factors, frequently ignored, have been found, such as lower and upper prestress, lack of symmetry in the cross section, variable width, a high ratio between flange width and web thickness or prestressing reinforcement location related to variable width. They can play a decisive role in non-conventional members. In addition, most methods are based on 2D simplifications. Finite Element modelling has been conducted in order to consider the influence of these factors. A linear 3D approach has been used. The modelled members vary according to cross section geometry, bond behaviour, or prestressing reinforcement location. In general, the obtained tensile stresses don’t agree with existing methods. An experimental adjustment has been conducted on the obtained results, with a high correlation ratio and significance level as well as a low dispersion and relative error. Therefore, a method to obtain the maximum spalling stress is proposed. The proposal consists on some equations that consider the special features of the typology and bond behaviour. Consistency between transmission length and bond behaviour is considered too. The equations are used to calculate maximum spalling stress for the studied typology members whose prestressing reinforcement is located out of the core of the cross section. In relation to bursting, a modification of existing methods is proposed. Compared to finite element results, the proposal improves mean value and dispersion, whose ranges are considered acceptable and secure. The method takes into account cross section geometry and location of prestressing reinforcement across the lower flange. Finally, strategies to design members of this typology or similar are proposed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to determine the effect of animal management and farm facilities on total feed intake (TFI), feed conversion ratio (FCR) and mortality rate (MORT) of grower-finishing pigs. In total, 310 batches from 244 grower-finishing farms, consisting of 454 855 Pietrain sired pigs in six Spanish pig companies were used. Data collection consisted of a survey on management practices (season of placement, split-sex by pens, number of pig origins, water source in the farm, initial or final BW) and facilities (floor, feeder, ventilation or number of animals placed) during 2008 and 2009. Results indicated that batches of pigs placed between January and March had higher TFI (P=0.006), FCR (P=0.005) and MORT (P=0.03) than those placed between July and September. Moreover, batches of pigs placed between April and June had lower MORT (P=0.003) than those placed between January and March. Batches which had split-sex pens had lower TFI (P=0.001) and better FCR (P<0.001) than those with mixed-sex in pens; pigs fed with a single-space feeder with incorporated drinker also had the lowest TFI (P<0.001) and best FCR (P<0.001) in comparison to single and multi-space feeders without a drinker. Pigs placed in pens with <50% slatted floors presented an improvement in FCR (P<0.05) than pens with 50% or more slatted floors. Batches filled with pigs from multiple origins had higher MORT (P<0.001) than those from a single origin. Pigs housed in barns that performed manual ventilation control presented higher MORT (P<0.001) in comparison to automatic ventilation. The regression analysis also indicated that pigs which entered to grower-finisher facilities with higher initial BW had lower MORT (P<0.05) and finally pigs which were sent to slaughterhouse with a higher final BW presented higher TFI (P<0.001). The variables selected for each dependent variable explained 61.9%, 24.8% and 20.4% of the total variability for TFI, FCR and MORT, respectively. This study indicates that farms can increase growth performance and reduce mortality by improving farm facilities and/or modifying management practices.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Las exigencias de calidad, tanto en el ámbito de la rehabilitación como en el de las obras de nueva planta, obligan a evitar la fisuración de la tabiquería. Una de sus principales causas es la deformación excesiva de los forjados. Aunque en la mayoría de los casos no tiene efectos estructurales sino solamente estéticos, es necesario tomar precauciones para evitar la fisuración, pues es una de las patologías más frecuentes y en muchos casos motivo de reclamación de los usuarios. El aumento del consumo de los paneles de placa de yeso laminado y lana de roca para la realización de tabiquerías, justifica la necesidad de ahondar en el conocimiento del comportamiento y del mecanismo de fisuración de este material, pues hasta la fecha no se ha encontrado ningún trabajo especificamente dedicado al estudio del comportamiento en fractura de paneles sandwich de placa de yeso laminado y lana de roca en su plano. A la hora de abordar el estudio del comportamiento en fractura del material objeto de esta tesis, es preciso tener en cuenta que se trata de un material compuesto y, como tal, sus propiedades mecánicas y resistentes dependen en gran medida de las de sus componentes. Por tanto, para poder explicar el comportamiento en fractura del panel sandwich, habrá que estudiar también el de sus componentes. Por otro lado, se considera también muy útil disponer de una herramienta de calculo para la simulación de la fractura de paneles sandwich que sea predictiva. Este modelo hará posible facilitar el diseño de tabiquerías que no se fisure con este material, al poder relacionar las flechas que pueden tomar los forjados con su potencial fisuración. Para contrastar y validar un modelo de este tipo, es necesario disponer de suficientes datos experimentales del comportamiento en fractura del panel sandwich de placa de yeso laminado y lana de roca, que se puedan simular numericamente con el mismo. A partir de lo anteriormente expuesto se plantea, en primer lugar, una campaña experimental con el fin de obtener los parámetros necesarios para caracterizar el comportamiento en fractura de los paneles sandwich y sus componentes: placa de yeso laminado y lana de roca, estudiando también, su comportamiento en fractura en Modo Mixto, y el efecto del tamaño en los parámetros del panel. Por otro lado se propone un modelo de cálculo para la simulación de la fractura en Modo Mixto de paneles sandwich de placa de yeso laminado y lana de roca, comprobando la validez del modelo numérico a partir de los resultados experimentales obtenidos en la campaña de ensayos. Finalmente, se aplica el modelo para estudiar la fisuración de tabiquería realizada con el panel sandwich producida por la deformación de forjados unidireccionales realizados con viguetas de hormigón y bovedilla cerámica, por ser esta tipología la más usual en obras de edificación de viviendas. The quality requirements in terms of rehabilitation and new Works, force to prevent cracking on partitions and one of the main causes is the excessive deformation of the floor. In most of the cases, there are any structural damages, only aesthetic effects, but it is necessary to take precautions to avoid cracking because it is one of the most common diseases and in addition is the main reason of user’s complaints. The increased consumption of plasterboard panels and mineral wool used to build partitions, justifies the need to develop a deeper understanding of the cracking behaviour and mechanism, because by now, any specifically work dedicated to the study of fractures behaviour of sandwich plasterboard panels and rock wool has been found. When approaching the study of the fracture behaviour of the material it must bear in mind that we are referring to a composite material and as such, its mechanical and strength properties depend heavily on its components. Therefore, to explain the fracture behaviour of sandwich panels its components must be studied as well. On the other hand, it is also considered very useful to have a calculation tool to simulate the more likely fractures of the sandwich panel in order to predict it. This model used to perform simulations will enable the design of partitions built with these materials without cracks because it will relate the deflections in decks with its potential cracking. To contrast and validate this type of model, it is necessary and imperative to have enough experimental data of the sandwich plasterboard and rock wool fractures in order to enable its numerical simulation with it. On the basis of the above, the question arises firstly an experimental campaign in order to obtain the necessary parameters to characterize the cracking behaviour of sandwich panels and its components: plasterboard and rock wool, studying also its cracking behaviour in a mixed mode fracture and the effect of size parameters of the panel. Furthermore, a calculation model to simulate fractures in mixed mode of the sandwich panels made of plasterboard and rock wool is proposed in order to check the validity of the numerical model, based on experimental results obtained from the test campaign. Finally, this model is applied to study cracking on partitions built with sandwich panels resulting from the unidirectional floor’s deformations built with prestressed concrete beams and slab pottery pieces being this typology the most common one on residential buildings works.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El riesgo de caída por deslizamiento en los edificios es un riesgo muy importante ya que supone numerosas muertes, perdida de días laborales y secuelas, así como importantes costes económicos. Se trata de accidentes difíciles de predecir debido al número de factores que intervienen para que se produzcan, muchos de los cuales son difícilmente controlables, como el calzado del usuario o su comportamiento. Para evitar un resbalón es necesario que la fricción del conjunto pavimento/calzado/contaminante supere el coeficiente de fricción requerido para la estabilidad y que depende de la forma de caminar, la longitud del paso, etc. Por ello, es necesario medir la contribución del pavimento al riesgo de deslizamiento y limitarla adecuadamente. A lo largo de la historia reciente se han diseñado y desarrollado multitud de aparatos con la intención de medir esta contribución en la forma de coeficientes de fricción —dinámicos, estáticos, de transición— sin llegar a un acuerdo sobre cuál es el método más apropiado. La reglamentación española de edificación, que ha sufrido un importante cambio recientemente con la adopción de un nuevo código basado en prestaciones, ha sido innovadora en este campo introduciendo por primera vez una medida contrastable de la contribución del pavimento al riesgo de deslizamiento mediante el ensayo del péndulo de fricción en húmedo. Sin embargo, el desacuerdo a nivel europeo sobre un ensayo único y las limitaciones en las normas de ensayo existentes derivadas de esta falta de consenso, han sido la causa de que la solución aportada por el Código Técnico de la Edificación (CTE) se cimentara en normas que no contemplaban todas las modalidades de ensayo. Esto ha generado algunos problemas de aplicación que han afectado fundamentalmente a los pavimentos pulidos, que han visto prácticamente vetada su utilización en los edificios incluso en las zonas donde, por no existir presencia de agua, el riesgo es menor. El objetivo de esta tesis es analizar estos problemas de aplicación, ligados al ensayo del péndulo de fricción, y tratar de resolverlos optimizando el procedimiento de ensayo empleado, modificando sus condiciones, para representar de forma mucho más adecuada el riesgo que se pretende limitar. Para ello se ha estudiado de forma exhaustiva la literatura científica y las normas y reglamentaciones, tanto españolas como extranjeras. Se han detectado los posibles problemas que podría plantear la introducción del ensayo del péndulo de fricción en seco y se ha diseñado una campaña de ensayos, tanto de coeficiente de fricción con el péndulo, como de la rugosidad superficial, para confirmarlos o desecharlos. El análisis de los resultados de la campaña de ensayos ha permitido validar la modalidad de ensayo planteada y proponer una medida complementaria de la rugosidad superficial que resulte útil para facilitar la evaluación de este riesgo no poco importante. Los resultados de esta tesis han permitido desarrollar una modificación del CTE de próxima aparición y un documento de apoyo que ya la adelanta, y con ello, resolver el problema de aplicación del CTE a los pavimentos pulidos. ABSTRACT Slipping accidents in building environments are a serious problem involving numerous fatal accidents, loss of work days, incapacity and great costs. Prediction of such accidents is difficult due to the number of factors involved, many of which are not controllable, like footwear or users behavior. To prevent a slip the coefficient of friction provided by the combination floor-footwear-contaminant must be greater than the required coefficient of friction for stability, that depends on the step length and the walking speed among other factors. It is then necessary to measure the contribution of the floor to the slipping risk so it can be limited to an adequate extent. In the recent history many apparatuses have been developed in order to measure this contribution in the form of friction coefficients —dynamic, static or even transition COFs— but none of them seems to be internationally accepted as sufficiently valid. The Spanish Building Code, which has recently undergone a big change to a performance based code, has been innovative in this area, introducing for the first time a measurement of this contribution by means of the friction pendulum test. However, due to the European disagreement about an unique test for slip resistance, and to the limitations of the European standards derived from it, the Spanish Building Code relies on standards that do not take into account all possible methods. As a consequence, smooth floors have been seriously affected and cannot be installed in almost any place, not even in dry areas where the risk of slipping is much lower. The aim of this research is to analyze these problems associated with the pendulum test and resolve them proposing some changes to the test conditions in order to represent in a proper manner the real risk that is to be considered: the slip in dry conditions. Relevant scientific literature has been studied as well as Spanish and foreign codes and standards. Potential problems of the pendulum test in dry conditions have been detected and an experiment has been designed to confirm or discard them, testing both friction coefficient and surface roughness. The results of the experiment have permitted to validate the pendulum test in dry conditions and to suggest a complementary measurement of the surface roughness to help evaluate the slip resistance of a floor. These results have also permitted to develop an amendment to the building code that will appear soon. In the meanwhile it has been included in a support document issued by the administration to resolve this urgent problem.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Existe un amplio catálogo de posibles soluciones para resolver la problemática de las zapatas de medianería así como, por extensión, las zapatas de esquina como caso particular de las anteriores. De ellas, las más habitualmente empleadas en estructuras de edificación son, por un lado, la utilización de una viga centradora que conecta la zapata de medianería con la zapata del pilar interior más próximo y, por otro, la colaboración de la viga de la primera planta trabajando como tirante. En la primera solución planteada, el equilibrio de la zapata de medianería y el centrado de la respuesta del terreno se consigue gracias a la colaboración del pilar interior con su cimentación y al trabajo a flexión de la viga centradora. La modelización clásica considera que se logra un centrado total de la reacción del terreno, con distribución uniforme de las tensiones de contacto bajo ambas zapatas. Este planteamiento presupone, por tanto, que la viga centradora logra evitar cualquier giro de la zapata de medianería y que el pilar puede, por ello, considerarse perfectamente empotrado en la cimentación. En este primer modelo, el protagonismo fundamental recae en la viga centradora, cuyo trabajo a flexión conduce frecuentemente a unas escuadrías y a unas cuantías de armado considerables. La segunda solución, plantea la colaboración de la viga de la primera planta, trabajando como tirante. De nuevo, los métodos convencionales suponen un éxito total en el mecanismo estabilizador del tirante, que logra evitar cualquier giro de la zapata de medianería, dando lugar a una distribución de tensiones también uniforme. Los modelos convencionales existentes para el cálculo de este tipo de cimentaciones presentan, por tanto, una serie de simplificaciones que permiten el cálculo de las mismas, por medios manuales, en un tiempo razonable, pero presentan el inconveniente de su posible alejamiento del comportamiento real de la cimentación, con las consecuencias negativas que ello puede suponer en el dimensionamiento de estos elementos estructurales. La presente tesis doctoral desarrolla un contraste de los modelos convencionales de cálculo de cimentaciones de medianería y esquina, mediante un análisis alternativo con modelos de elementos finitos, con el objetivo de poner de manifiesto las diferencias entre los resultados obtenidos con ambos tipos de modelización, analizar cuáles son las variables que más influyen en el comportamiento real de este tipo de cimentaciones y proponer un nuevo modelo de cálculo, de tipo convencional, más ajustado a la realidad. El proceso de investigación se desarrolla mediante una etapa experimental virtual que utiliza como modelo un pórtico tipo de edificación, ortogonal, de hormigón armado, con dos vanos y número variable de plantas. Tras identificar el posible giro de la cimentación como elemento clave en el comportamiento de las zapatas de medianería y de esquina, se adoptan como variables de estudio aquellas que mayor influencia puedan tener sobre el citado giro de las zapatas y sobre la rigidez del conjunto del elemento estructural. Así, se han estudiado luces de 3 m a 7 m, diferente número de plantas desde baja+1 hasta baja+4, resistencias del terreno desde 100 kN/m2 hasta 300 kN/m2, relaciones de forma de la zapata de medianería de 1,5 : 1 y 2 : 1, aumento y reducción de la cuantía de armado de la viga centradora y variación del canto de la viga centradora desde el mínimo canto compatible con el anclaje de la armadura de los pilares hasta un incremento del 75% respecto del citado canto mínimo. El conjunto de pórticos generados al aplicar las variables indicadas, se ha calculado tanto por métodos convencionales como por el método de los elementos finitos. Los resultados obtenidos ponen de manifiesto importantes discrepancias entre ambos métodos que conducen a importantes diferencias en el dimensionamiento de este tipo de cimentaciones. El empleo de los métodos tradicionales da lugar, por un lado, a un sobredimensionamiento de la armadura de la viga centradora y, por otro, a un infradimensionamiento, tanto del canto de la viga centradora, como del tamaño de la zapata de medianería y del armado de la viga de la primera planta. Finalizado el análisis y discusión de resultados, la tesis propone un nuevo método alternativo, de carácter convencional y, por tanto, aplicable a un cálculo manual en un tiempo razonable, que permite obtener los parámetros clave que regulan el comportamiento de las zapatas de medianería y esquina, conduciendo a un dimensionamiento más ajustado a las necesidades reales de este tipo de cimentación. There is a wide catalogue of possible solutions to solve the problem of party shoes and, by extension, corner shoes as a special case of the above. From all of them, the most commonly used in building structures are, on one hand, the use of a centering beam that connects the party shoe with the shoe of the nearest interior pillar and, on the other hand, the collaboration of the beam of the first floor working as a tie rod. In the first proposed solution, the balance of the party shoe and the centering of the ground response is achieved thanks to the collaboration of the interior pillar with his foundation along with the bending work of the centering beam. Classical modeling considers that a whole centering of the ground reaction is achieved, with uniform contact stress distribution under both shoes. This approach to the issue presupposes that the centering beam manages to avoid any rotation of the party shoe, so the pillar can be considered perfectly embedded in the foundation. In this first model, the leading role lies in the centering beam, whose bending work usually leads to important section sizes and high amounts of reinforced. The second solution, consideres the collaboration of the beam of the first floor, working as tie rod. Again, conventional methods involve a total success in the stabilizing mechanism of the tie rod, that manages to avoid any rotation of the party shoe, resulting in a stress distribution also uniform. Existing conventional models for calculating such foundations show, therefore, a series of simplifications which allow calculation of the same, by manual means, in a reasonable time, but have the disadvantage of the possible distance from the real behavior of the foundation, with the negative consequences this could bring in the dimensioning of these structural elements. The present thesis develops a contrast of conventional models of calculation of party and corner foundations by an alternative analysis with finite element models with the aim of bring to light the differences between the results obtained with both types of modeling, analysis which are the variables that influence the real behavior of this type of foundations and propose a new calculation model, conventional type, more adjusted to reality. The research process is developed through a virtual experimental stage using as a model a typical building frame, orthogonal, made of reinforced concrete, with two openings and variable number of floors. After identifying the possible spin of the foundation as the key element in the behavior of the party and corner shoes, it has been adopted as study variables, those that may have greater influence on the spin of the shoes and on the rigidity of the whole structural element. So, it have been studied lights from 3 m to 7 m, different number of floors from lower floor + 1 to lower floor + 4, máximum ground stresses from 100 kN/m2 300 kN/m2, shape relationships of party shoe 1,5:1 and 2:1, increase and decrease of the amount of reinforced of the centering beam and variation of the height of the centering beam from the minimum compatible with the anchoring of the reinforcement of pillars to an increase of 75% from the minimum quoted height. The set of frames generated by applying the indicated variables, is calculated both by conventional methods such as by the finite element method. The results show significant discrepancies between the two methods that lead to significant differences in the dimensioning of this type of foundation. The use of traditional methods results, on one hand, to an overdimensioning of the reinforced of the centering beam and, on the other hand, to an underdimensioning, both the height of the centering beam, such as the size of the party shoe and the reinforced of the beam of the first floor. After the analysis and discussion of results, the thesis proposes a new alternative method, conventional type and, therefore, applicable to a manual calculation in a reasonable time, that allows to obtain the key parameters that govern the behavior of party and corner shoes, leading to a dimensioning more adjusted to the real needings of this type of foundation.