38 resultados para Field-effect
em Universidad Politécnica de Madrid
Resumo:
In this paper, we show room temperature operation of a quantum well infrared photodetector (QWIP) using lateral conduction through ohmic contacts deposited at both sides of two n-doped quantum wells. To reduce the dark current due to direct conduction in the wells, we apply an electric field between the quantum wells and two pinch-off Schottky gates, in a fashion similar to a field effect device. Since the normal incidence absorption is strongly reduced in intersubband transitions in quantum wells, we first analyze the response of a detector based on quantum dots (QD). This QD device shows photocurrent signal up to 150 K when it is processed in conventional vertical detector. However, it is possible to observe room temperature signal when it is processed in a lateral structure. Finally, the room temperature photoresponse of the QWIP is demonstrated, and compared with theory. An excellent agreement between the estimated and measured characteristics of the device is found
Resumo:
The pH response of GaN/AlInN/AlN/GaN ion-sensitive field effect transistor (ISFET) on Si substrates has been characterized. We analyzed the variation of the surface potential (ΔVsp/ΔpH) and current (ΔIds/ΔpH) with solution pH in devices with the same indium content (17%, in-plane lattice-matched to GaN) and different AlInN thickness (6 nm and 10 nm), and compared with the literature. The shrinkage of the barrier, that has the effect to increase the transconductance of the device, makes the 2-dimensional electron density (2DEG) at the interface very sensitive to changes in the surface. Although the surface potential sensitivity to pH is similar in the two devices, the current change with pH (ΔIds/ΔpH), when biasing the ISFET by a Ag/AgCl reference electrode, is almost 50% higher in the device with 6 nm AlInN barrier, compared to the device with 10 nm barrier. When measuring the current response (ΔIds/ΔpH) without reference electrode, the device with thinner AlInN layer has a larger response than the thicker one, of a factor of 140%, and that current response without reference electrode is only 22% lower than its maximum response obtained using reference electrode.
Resumo:
n this work, we explain a method to characterize graphene using electrical measurements in graphene field-effect transistors (GFET) devices. Our goal is to obtain the material electronic properties from the output characteristics of one GFET device. For the previous purpose, we will need to apply a physical model that allows us to correlate the electronic behavior of a GFET with the material properties.
Resumo:
The façade is the visible part of a building, and generally consists of various different constructive systems. The sound reduction index of the closing elements for the openings on a room’s façade is a determining factor in the sound insulation from airborne noise inside the space. Windows are the transparent part of the façade, and to improve their thermal behaviour and control solar radiation, they are often fitted with a series of external and internal protections such as shutters, slats and blinds. This work contains a summary of studies carried out using field measurements of airborne sound insulation on façades in rooms, in application of the standard UNE-EN ISO 140-5:1999. In all the rooms the windows were fitted with shutter boxes and rolling shutters, and the acoustic tests were made with the shutter in two positions (extended and fully retracted). The results were analysed considering the window opening system (openable or sliding) and the type of glass pane (monolithic or insulating glass unit, IGU). In the case of sliding windows, the airborne sound insulation of façades is greater when the shutter is extended than when it is retracted, and this should be taken into account when applying the aforementioned standard.
Resumo:
The influence of a strong, high‐frequency electric field on the ion‐ion correlations in a fully ionized plasma is investigated in the limit of infinite ion mass, starting with the Bogoliubov‐Born‐Green‐Kirkwood‐Yvon hierarchy of equations; a significant departure from the thermal correlations is found. It is shown that the above effect may substantially modify earlier results on the nonlinear high‐frequency plasma conductivity.
Resumo:
Engineering of devices and systems such as magnets, fault current limiters or cables, based on High Temperature Superconducting wires requires a deep characterization of the possible degradation of their properties by handling at room temperature as well as during the service life thus establishing the limits for building up functional devices and systems. In the present work we report our study regarding the mechanical behavior of spliced joints between commercial HTS coated conductors based on YBCO at room temperature and service temperature, 77 K. Tensile tests under axial stress and the evolution of the critical current and the electric resistance of the joints have been measured. The complete strain contour for the tape and the joint has been obtained by using Digital Image Correlation. Also, tensile tests under external magnetic field have been performed and the effect of the applied field on the critical current and the electric resistance of the joints has been studied. Finally, a preliminary numerical study by means of Finite Element Method (FEM) of the mechanical behavior of the joints between commercial HTS is presented.
Resumo:
Engineering of devices and systems such as magnets, fault current limiters or cables, based on High Temperature Superconducting wires requires a deep characterization of the possible degradation of their properties by handling at room temperature as well as during the service life thus establishing the limits for building up functional devices and systems. In the present work we report our study regarding the mechanical behavior of spliced joints between commercial HTS coated conductors based on YBCO at room temperature and service temperature, 77 K. Tensile tests under axial stress and the evolution of the critical current and the electric resistance of the joints have been measured. The complete strain contour for the tape and the joints has been obtained by using Digital Image Correlation. Also, tensile tests under external magnetic field have been performed and the effect of the applied field on the critical current and the electric resistance of the joints has been studied. Additionally, fatigue tests under constant cyclic stress and loading-unloading ramps have been carried out in order to evaluate the electromechanical behavior of the joints and the effect of maximum applied stress on the critical current. Finally, a preliminary numerical study by means of the Finite Element Method (FEM) of the electromechanical behavior of the joints between commercial HTS is presented.
Resumo:
An eiectrodynamic Tether is a long thin conductive string deployed from a spacecraft. A part of the ED tether near one end, which is rendered positive by the Electromotive force (EMF)along the tether, collects electrons from the ambient plasma. In the frame of reference moving with theter, ions flow toward the tether, get deflected near the tether by its high positive potential and create a wake. Due to the asymmetry of plasma distribution and the weak but significant Geomagnetic field, the conventional probe theory becomes almost inapplicable. Computational work for the prediction of current collection is thus necessiated.. In this paper, we analyze effects of magnetic field on velocity distribution funtion at a point that is far from the tether, and discuss a new way to treat electrons at computational boundary. Three cases with different magnetic field are simulated and compiled so as to provide a part of the pre-flight prediction of the space experiment by NASA ProSEDS, which is planned September 2002.
Resumo:
Multi-stacked InAs/AlGaAs quantum dot solar cells (QDSCs) introduced with field damping layers (FDL) which sustain the junction built-in potential have been studied. Without an external bias condition, the external quantum efficiency (EQE) of QD layers are reduced by introducing the thick FDL, because the carrier escape due to built-in electric field was suppressed. On the other hand, the photocurrent production due to two-step absorption is increased by the formation of flat-band QD structure for QDSC with thick FDL.
Resumo:
This doctoral thesis explores some of the possibilities that near-field optics can bring to photovoltaics, and in particular to quantum-dot intermediate band solar cells (QD-IBSCs). Our main focus is the analytical optimization of the electric field distribution produced in the vicinity of single scattering particles, in order to produce the highest possible absorption enhancement in the photovoltaic medium in their surroundings. Near-field scattering structures have also been fabricated in laboratory, allowing the application of the previously studied theoretical concepts to real devices. We start by looking into the electrostatic scattering regime, which is only applicable to sub-wavelength sized particles. In this regime it was found that metallic nano-spheroids can produce absorption enhancements of about two orders of magnitude on the material in their vicinity, due to their strong plasmonic resonance. The frequency of such resonance can be tuned with the shape of the particles, allowing us to match it with the optimal transition energies of the intermediate band material. Since these metallic nanoparticles (MNPs) are to be inserted inside the cell photovoltaic medium, they should be coated by a thin insulating layer to prevent electron-hole recombination at their surface. This analysis is then generalized, using an analytical separation-of-variables method implemented in Mathematica7.0, to compute scattering by spheroids of any size and material. This code allowed the study of the scattering properties of wavelengthsized particles (mesoscopic regime), and it was verified that in this regime dielectric spheroids perform better than metallic. The light intensity scattered from such dielectric spheroids can have more than two orders of magnitude than the incident intensity, and the focal region in front of the particle can be shaped in several ways by changing the particle geometry and/or material. Experimental work was also performed in this PhD to implement in practice the concepts studied in the analysis of sub-wavelength MNPs. A wet-coating method was developed to self-assemble regular arrays of colloidal MNPs on the surface of several materials, such as silicon wafers, amorphous silicon films, gallium arsenide and glass. A series of thermal and chemical tests have been performed showing what treatments the nanoparticles can withstand for their embedment in a photovoltaic medium. MNPs arrays are then inserted in an amorphous silicon medium to study the effect of their plasmonic near-field enhancement on the absorption spectrum of the material. The self-assembled arrays of MNPs constructed in these experiments inspired a new strategy for fabricating IBSCs using colloidal quantum dots (CQDs). Such CQDs can be deposited in self-assembled monolayers, using procedures similar to those developed for the patterning of colloidal MNPs. The use of CQDs to form the intermediate band presents several important practical and physical advantages relative to the conventional dots epitaxially grown by the Stranski-Krastanov method. Besides, this provides a fast and inexpensive method for patterning binary arrays of QDs and MNPs, envisioned in the theoretical part of this thesis, in which the MNPs act as antennas focusing the light in the QDs and therefore boosting their absorption
Resumo:
This study investigated the changes in cardiorespiratory response and running performance of 9 male ?Talent Identification? (TID) and 6 male Senior Elite (SE) Spanish National Squad triathletes during a specific cycle-run test. The TID and SE triathletes (initial age 15.2±0.7 vs. 23.8±5.6 years, p=0.03; tests through the competitive period and the preparatory period, respectively, of two consecutive seasons: Test 1 was an incremental cycle test to determine the ventilatory threshold (Thvent); Test 2 (C-R) was 30 min constant load cycling at the Thvent power output followed by a 3-km time trial run; and Test 3 (R) was an isolated 3-km time trial control run, in randomized counterbalanced order. In both seasons the time required to complete the C-R 3-km run was greater than for R in TID (11:09±00:24 vs. 10:45±00:16 min:ss, pmenor que 0.01; and 10:24±00:22 vs. 10:04±00:14, p=0.006, for season 2005/06 and 2006/07, respectively) and SE (10:15±00:19 vs. 09:45±00:30, pmenor que 0.001 and 09:51±00:26 vs. 09:46±00:06, p= 0.02 for season 2005/06 and 2006/07, respectively). Compared to the first season, completion of the time trial run was faster in the second season (6.6%, pmenor que 0.01 and 6.4%, pmenor que 0.01, for C-R and R test, respectively) only in TID. Changes in post-cycling run performance were accompanied by changes in pacing strategy but only slight or non-significant changes in the cardiorespiratory response. Thus, the negative effect of cycling on performance may persist, independently of the period, over two consecutive seasons in TID and SE triathletes; however A improvements over time suggests that monitoring running pacing strategy after cycling may be a useful tool to control performance and training adaptations in TID. O2max 77.0±5.6 vs. 77.8±3.6 mL·kg-1·min-1, NS) underwent three TE D EP C C
Resumo:
This paper describes two methods to cancel the effect of two kinds of leakage signals which may be presented when an antenna is measured in a planar near-field range. One method tries to reduce leakage bias errors from the receiver¿s quadrature detector and it is based on estimating the bias constant added to every near-field data sample. Then, that constant is subtracted from the data, removing its undesired effect on the far-field pattern. The estimation is performed by back-propagating the field from the scan plane to the antenna under test plane (AUT) and averaging all the data located outside the AUT aperture. The second method is able to cancel the effect of the leakage from faulty transmission lines, connectors or rotary joints. The basis of this method is also a reconstruction process to determine the field distribution on the AUT plane. Once this distribution is known, a spatial filtering is applied to cancel the contribution due to those faulty elements. After that, a near-field-to-far-field transformation is applied, obtaining a new radiation pattern where the leakage effects have disappeared. To verify the effectiveness of both methods, several examples are presented.
Resumo:
La Directiva 2003/10/CE del Parlamento Europeo y del Consejo, del 6 de febrero de 2003, específica con arreglo al apartado 1 del artículo 16 de la Directiva 89/391/CEE las disposiciones mínimas de seguridad y de salud relativas a la exposición de los trabajadores a los riesgos derivados de los agentes físicos (ruido). En la industria musical, y en concreto en los músicos de orquesta, una exposición de más de ocho horas al día a un nivel de presión sonora de 80dB(A) o más es algo muy común. Esta situación puede causar a los trabajadores daños auditivos como la hiperacusia, hipoacusia, tinitus o ruptura de la membrana basilar entre otros. Esto significa que deben tomarse medidas para implementar las regulaciones de la forma más razonable posible para que la interpretación del músico, la dinámica y el concepto musical que se quiere transmitir al público se vea lo menos afectada posible. Para reducir la carga auditiva de los músicos de orquesta frente a fuertes impactos sonoros provenientes de los instrumentos vecinos, se está investigando sobre el uso de unos paneles acústicos que colocados en puntos estratégicos de la orquesta pueden llegar a reducir el impacto sonoro sobre el oído hasta 20dB. Los instrumentos de viento metal y de percusión son los responsables de la mayor emisión de presión sonora. Para proteger el oído de los músicos frente a estos impactos, se colocan los paneles en forma de barrera entre dichos instrumentos y los músicos colocados frente a ellos. De esta forma se protege el oído de los músicos más afectados. Para ver el efecto práctico que producen estos paneles en un conjunto orquestal, se realizan varias grabaciones en los ensayos y conciertos de varias orquestas. Los micrófonos se sitúan a la altura del oído y a una distancia de no más de 10cm de la oreja de varios de los músicos más afectados y de los músicos responsables de la fuerte emisión sonora. De este modo se puede hacer una comparación de los niveles de presión sonora que percibe cada músico y evaluar las diferencias de nivel existentes entre ambos. Así mismo se utilizan configuraciones variables de los paneles para comparar las diferencias de presión sonora que existen entre las distintas posibilidades de colocarlos y decidir así sobre la mejor ubicación y configuración de los mismos. A continuación, una vez obtenidos las muestras de audio y los diferentes archivos de datos medidos con un analizador de audio en distintas posiciones de la orquesta, todo ello se calibra y analiza utilizando un programa desarrollado en Matlab, para evaluar el efecto de los paneles sobre la percepción auditiva de los músicos, haciendo especial hincapié en el análisis de las diferencias de nivel de presión sonora (SPL). Mediante el cálculo de la envolvente de las diferencias de nivel, se evalúa de un modo estadístico el efecto de atenuación de los paneles acústicos en los músicos de orquesta. El método está basado en la probabilidad estadística de varias muestras musicales ya que al tratarse de música tocada en directo, la dinámica y la sincronización entre los músicos varía según el momento en que se toque. Estos factores junto con el hecho de que la partitura de cada músico es diferente dificulta la comparación entre dos señales grabadas en diferentes puntos de la orquesta. Se necesita por lo tanto de varias muestras musicales para evaluar el efecto de atenuación de los paneles en las distintas configuraciones mencionadas anteriormente. El estudio completo del efecto de los paneles como entorno que influye en los músicos de orquesta cuando están sobre el escenario, tiene como objetivo la mejora de sus condiciones de trabajo. Abstract For several years, the European Union has been adopting many laws and regulations to protect and give more security to people who are exposed to some risk in their job. Being exposed to a loud sound pressure level during many hours in the job runs the risk of hearing damage. Particularly in the field of music, the ear is the most important working tool. Not taking care of the ear can cause some damage such as hearing loss, tinnitus, hyperacusis, diplacusis, etc. This could have an impact on the efficiency and satisfaction of the musicians when they are playing, which could also cause stress problems. Orchestra musicians, as many other workers in this sector, are usually exposed to a sound level of 80dB(A) or more during more than eight hours per day. It means that they must satisfy the law and their legal obligations to avoid health problems proceeding from their job. Putting into practice the new regulations is a challenge for orchestras. They must make sure that the repertoire, with its dynamic, balance and feeling, is not affected by the reduction of sound levels imposed by the law. This study tries to investigate the benefits and disadvantages of using shields as a hearing protector during rehearsals and orchestral concerts.
Resumo:
La termografía infrarroja (TI) es una técnica no invasiva y de bajo coste que permite, con el simple acto de tomar una fotografía, el registro sin contacto de la energía que irradia el cuerpo humano (Akimov & Son’kin, 2011, Merla et al., 2005, Ng et al., 2009, Costello et al., 2012, Hildebrandt et al., 2010). Esta técnica comenzó a utilizarse en el ámbito médico en los años 60, pero debido a los malos resultados como herramienta diagnóstica y la falta de protocolos estandarizados (Head & Elliot, 2002), ésta se dejó de utilizar en detrimento de otras técnicas más precisas a nivel diagnóstico. No obstante, las mejoras tecnológicas de la TI en los últimos años han hecho posible un resurgimiento de la misma (Jiang et al., 2005, Vainer et al., 2005, Cheng et al., 2009, Spalding et al., 2011, Skala et al., 2012), abriendo el camino a nuevas aplicaciones no sólo centradas en el uso diagnóstico. Entre las nuevas aplicaciones, destacamos las que se desarrollan en el ámbito de la actividad física y el deporte, donde recientemente se ha demostrado que los nuevos avances con imágenes de alta resolución pueden proporcionar información muy interesante sobre el complejo sistema de termorregulación humana (Hildebrandt et al., 2010). Entre las nuevas aplicaciones destacan: la cuantificación de la asimilación de la carga de trabajo físico (Čoh & Širok, 2007), la valoración de la condición física (Chudecka et al., 2010, 2012, Akimov et al., 2009, 2011, Merla et al., 2010), la prevención y seguimiento de lesiones (Hildebrandt et al., 2010, 2012, Badža et al., 2012, Gómez Carmona, 2012) e incluso la detección de agujetas (Al-Nakhli et al., 2012). Bajo estas circunstancias, se acusa cada vez más la necesidad de ampliar el conocimiento sobre los factores que influyen en la aplicación de la TI en los seres humanos, así como la descripción de la respuesta de la temperatura de la piel (TP) en condiciones normales, y bajo la influencia de los diferentes tipos de ejercicio. Por consiguiente, este estudio presenta en una primera parte una revisión bibliográfica sobre los factores que afectan al uso de la TI en los seres humanos y una propuesta de clasificación de los mismos. Hemos analizado la fiabilidad del software Termotracker, así como su reproducibilidad de la temperatura de la piel en sujetos jóvenes, sanos y con normopeso. Finalmente, se analizó la respuesta térmica de la piel antes de un entrenamiento de resistencia, velocidad y fuerza, inmediatamente después y durante un período de recuperación de 8 horas. En cuanto a la revisión bibliográfica, hemos propuesto una clasificación para organizar los factores en tres grupos principales: los factores ambientales, individuales y técnicos. El análisis y descripción de estas influencias deben representar la base de nuevas investigaciones con el fin de utilizar la TI en las mejores condiciones. En cuanto a la reproducibilidad, los resultados mostraron valores excelentes para imágenes consecutivas, aunque la reproducibilidad de la TP disminuyó ligeramente con imágenes separadas por 24 horas, sobre todo en las zonas con valores más fríos (es decir, zonas distales y articulaciones). Las asimetrías térmicas (que normalmente se utilizan para seguir la evolución de zonas sobrecargadas o lesionadas) también mostraron excelentes resultados pero, en este caso, con mejores valores para las articulaciones y el zonas centrales (es decir, rodillas, tobillos, dorsales y pectorales) que las Zonas de Interés (ZDI) con valores medios más calientes (como los muslos e isquiotibiales). Los resultados de fiabilidad del software Termotracker fueron excelentes en todas las condiciones y parámetros. En el caso del estudio sobre los efectos de los entrenamientos de la velocidad resistencia y fuerza en la TP, los resultados muestran respuestas específicas según el tipo de entrenamiento, zona de interés, el momento de la evaluación y la función de las zonas analizadas. Los resultados mostraron que la mayoría de las ZDI musculares se mantuvieron significativamente más calientes 8 horas después del entrenamiento, lo que indica que el efecto del ejercicio sobre la TP perdura por lo menos 8 horas en la mayoría de zonas analizadas. La TI podría ser útil para cuantificar la asimilación y recuperación física después de una carga física de trabajo. Estos resultados podrían ser muy útiles para entender mejor el complejo sistema de termorregulación humano, y por lo tanto, para utilizar la TI de una manera más objetiva, precisa y profesional con visos a mejorar las nuevas aplicaciones termográficas en el sector de la actividad física y el deporte Infrared Thermography (IRT) is a safe, non-invasive and low-cost technique that allows the rapid and non-contact recording of the irradiated energy released from the body (Akimov & Son’kin, 2011; Merla et al., 2005; Ng et al., 2009; Costello et al., 2012; Hildebrandt et al., 2010). It has been used since the early 1960’s, but due to poor results as diagnostic tool and a lack of methodological standards and quality assurance (Head et al., 2002), it was rejected from the medical field. Nevertheless, the technological improvements of IRT in the last years have made possible a resurgence of this technique (Jiang et al., 2005; Vainer et al., 2005; Cheng et al., 2009; Spalding et al., 2011; Skala et al., 2012), paving the way to new applications not only focused on the diagnose usages. Among the new applications, we highlighted those in physical activity and sport fields, where it has been recently proven that a high resolution thermal images can provide us with interesting information about the complex thermoregulation system of the body (Hildebrandt et al., 2010), information than can be used as: training workload quantification (Čoh & Širok, 2007), fitness and performance conditions (Chudecka et al., 2010, 2012; Akimov et al., 2009, 2011; Merla et al., 2010; Arfaoui et al., 2012), prevention and monitoring of injuries (Hildebrandt et al., 2010, 2012; Badža et al., 2012, Gómez Carmona, 2012) and even detection of Delayed Onset Muscle Soreness – DOMS- (Al-Nakhli et al., 2012). Under this context, there is a relevant necessity to broaden the knowledge about factors influencing the application of IRT on humans, and to better explore and describe the thermal response of Skin Temperature (Tsk) in normal conditions, and under the influence of different types of exercise. Consequently, this study presents a literature review about factors affecting the application of IRT on human beings and a classification proposal about them. We analysed the reliability of the software Termotracker®, and also its reproducibility of Tsk on young, healthy and normal weight subjects. Finally, we examined the Tsk thermal response before an endurance, speed and strength training, immediately after and during an 8-hour recovery period. Concerning the literature review, we proposed a classification to organise the factors into three main groups: environmental, individual and technical factors. Thus, better exploring and describing these influence factors should represent the basis of further investigations in order to use IRT in the best and optimal conditions to improve its accuracy and results. Regarding the reproducibility results, the outcomes showed excellent values for consecutive images, but the reproducibility of Tsk slightly decreased with time, above all in the colder Regions of Interest (ROI) (i.e. distal and joint areas). The side-to-side differences (ΔT) (normally used to follow the evolution of some injured or overloaded ROI) also showed highly accurate results, but in this case with better values for joints and central ROI (i.e. Knee, Ankles, Dorsal and Pectoral) than the hottest muscle ROI (as Thigh or Hamstrings). The reliability results of the IRT software Termotracker® were excellent in all conditions and parameters. In the part of the study about the effects on Tsk of aerobic, speed and strength training, the results of Tsk demonstrated specific responses depending on the type of training, ROI, moment of the assessment and the function of the considered ROI. The results showed that most of muscular ROI maintained warmer significant Tsk 8 hours after the training, indicating that the effect of exercise on Tsk last at least 8 hours in most of ROI, as well as IRT could help to quantify the recovery status of the athlete as workload assimilation indicator. Those results could be very useful to better understand the complex skin thermoregulation behaviour, and therefore, to use IRT in a more objective, accurate and professional way to improve the new IRT applications for the physical activity and sport sector.
Resumo:
El Zn es un elemento esencial para el crecimiento saludable y reproducción de plantas, animales y humanos. La deficiencia de Zn es una de las carencias de micronutrientes más extendidas en muchos cultivos, afectando a grandes extensiones de suelos en diferentes áreas agrícolas. La biofortificación agronómica de diferentes cultivos, incrementando la concentración de micronutriente Zn en la planta, es un medio para evitar la deficiencia de Zn en animales y humanos. Tradicionalmente se han utilizado fertilizantes de Zn inorgánicos, como el ZnSO4, aunque en los últimos años se están utilizado complejos de Zn como fuentes de este micronutriente, obteniéndose altas concentraciones de Zn soluble y disponible en el suelo. Sin embargo, el envejecimiento de la fuente en el suelo puede causar cambios importantes en su disponibilidad para las plantas. Cuando se añaden al suelo fuentes de Zn inorgánicas, las formas de Zn más solubles pierden actividad y extractabilidad con el paso del tiempo, transformándose a formas más estables y menos biodisponibles. En esta tesis se estudia el efecto residual de diferentes complejos de Zn de origen natural y sintético, aplicados en cultivos previos de judía y lino, bajo dos condiciones de riego distintas (por encima y por debajo de la capacidad de campo, respectivamente) y en dos suelos diferentes (ácido y calizo). Los fertilizantes fueron aplicados al cultivo previo en tres dosis diferentes (0, 5 y 10 mg Zn kg-1 suelo). El Zn fácilmente lixiviable se estimó con la extracción con BaCl2 0,1M. Bajo condiciones de humedad por encima de la capacidad de campo se obtuvieron mayores porcentajes de Zn lixiviado en el suelo calizo que en el suelo ácido. En el caso del cultivo de judía realizado en condiciones de humedad por encima de la capacidad de campo se compararon las cantidades extraídas con el Zn lixiviado real. El análisis de correlación entre el Zn fácilmente lixiviable y el estimado sólo fue válido para complejos con alta movilidad y para cada suelo por separado. Bajo condiciones de humedad por debajo de la capacidad de campo, la concentración de Zn biodisponible fácilmente lixiviable presentó correlaciones positivas y altamente significativas con la concentración de Zn disponible en el suelo. El Zn disponible se estimó con varios métodos de extracción empleados habitualmente: DTPA-TEA, DTPA-AB, Mehlich-3 y LMWOAs. Estas concentraciones fueron mayores en el suelo ácido que en el calizo. Los diferentes métodos utilizados para estimar el Zn disponible presentaron correlaciones positivas y altamente significativas entre sí. La distribución del Zn en las distintas fracciones del suelo fue estimada con diferentes extracciones secuenciales. Las extracciones secuenciales mostraron un descenso entre los dos cultivos (el anterior y el actual) en la fracción de Zn más lábil y un aumento en la concentración de Zn asociado a fracciones menos lábiles, como carbonatos, óxidos y materia orgánica. Se obtuvieron correlaciones positivas y altamente significativas entre las concentraciones de Zn asociado a las fracciones más lábiles (WSEX y WS+EXC, experimento de la judía y lino, respectivamente) y las concentraciones de Zn disponible, estimadas por los diferentes métodos. Con respecto a la planta se determinaron el rendimiento en materia seca y la concentración de Zn en planta. Se observó un aumento del rendimiento y concentraciones con el efecto residual de la dosis mayores (10 mg Zn kg-1) con respecto a la dosis inferior (5 mg Zn 12 kg-1) y de ésta con respecto a la dosis 0 (control). El incremento de la concentración de Zn en todos los tratamientos fertilizantes, respecto al control, fue mayor en el suelo ácido que en el calizo. Las concentraciones de Zn en planta indicaron que, en el suelo calizo, serían convenientes nuevas aplicaciones de Zn en posteriores cultivos para mantener unas adecuadas concentraciones en planta. Las mayores concentraciones de Zn en la planta de judía, cultivada bajo condiciones de humedad por encima de la capacidad de campo, se obtuvieron en el suelo ácido con el efecto residual del Zn-HEDTA a la dosis de 10 mg Zn kg-1 (280,87 mg Zn kg-1) y en el suelo calizo con el efecto residual del Zn-DTPA-HEDTA-EDTA a la dosis de 10 mg Zn kg-1 (49,89 mg Zn kg-1). En el cultivo de lino, cultivado bajo condiciones de humedad por debajo de la capacidad de campo, las mayores concentraciones de Zn en planta ese obtuvieron con el efecto residual del Zn-AML a la dosis de 10 mg Zn kg-1 (224,75 mg Zn kg-1) y en el suelo calizo con el efecto residual del Zn-EDTA a la dosis de 10 mg Zn kg-1 (99,83 mg Zn kg-1). El Zn tomado por la planta fue determinado como combinación del rendimiento y de la concentración en planta. Bajo condiciones de humedad por encima de capacidad de campo, con lixiviación, el Zn tomado por la judía disminuyó en el cultivo actual con respecto al cultivo anterior. Sin embargo, en el cultivo de lino, bajo condiciones de humedad por debajo de la capacidad de campo, se obtuvieron cantidades de Zn tomado superiores en el cultivo actual con respecto al anterior. Esta tendencia también se observó, en ambos casos, con el porcentaje de Zn usado por la planta. Summary Zinc is essential for healthy growth and reproduction of plants, animals and humans. Zinc deficiency is one of the most widespread micronutrient deficiency in different crops, and affect different agricultural areas. Agronomic biofortification of crops produced by an increased of Zn in plant, is one way to avoid Zn deficiency in animals and humans Sources with inorganic Zn, such as ZnSO4, have been used traditionally. Although, in recent years, Zn complexes are used as sources of this micronutrient, the provide high concentrations of soluble and available Zn in soil. However, the aging of the source in the soil could cause significant changes in their availability to plants. When an inorganic source of Zn is added to soil, Zn forms more soluble and extractability lose activity over time, transforming into forms more stable and less bioavailable. This study examines the residual effect of different natural and synthetic Zn complexes on navy bean and flax crops, under two different moisture conditions (above and below field capacity, respectively) and in two different soils (acid and calcareous). Fertilizers were applied to the previous crop in three different doses (0, 5 y 10 mg Zn kg-1 soil). The easily leachable Zn was estimated by extraction with 0.1 M BaCl2. Under conditions of moisture above field capacity, the percentage of leachable Zn in the calcareous soil was higher than in acid soil. In the case of navy bean experiment, performed in moisture conditions of above field capacity, amounts extracted of easily leachable Zn were compared with the real leachable Zn. Correlation analysis between the leachable Zn and the estimate was only valid for complex with high mobility and for each soil separately. Under moisture conditions below field capacity, the concentration of bioavailable easily leachable Zn showed highly significant positive correlations with the concentration of available soil Zn. The available Zn was estimated with several commonly used extraction methods: DTPA-TEA, AB-DTPA, Mehlich-3 and LMWOAs. These concentrations were higher in acidic soil than in the calcareous. The different methods used to estimate the available Zn showed highly significant positive correlations with each other. The distribution of Zn in the different fractions of soil was estimated with different sequential extractions. The sequential extractions showed a decrease between the two crops (the previous and current) at the most labile Zn fraction and an increase in the concentration of Zn associated with the less labile fractions, such as carbonates, oxides and organic matter. A positive and highly significant correlation was obtained between the concentrations of Zn associated with more labile fractions (WSEX and WS + EXC, navy bean and flax experiments, respectively) and available Zn concentrations determined by the different methods. Dry matter yield and Zn concentration in plants were determined in plant. Yield and Zn concentration in plant were higher with the residual concentrations of the higher dose applied (10 mg Zn kg-1) than with the lower dose (5 mg Zn kg-1), also these parameters showed higher values with application of this dose than with not Zn application. The increase of Zn concentration in plant with Zn treatments, respect to the control, was greater in the acid soil than in the calcareous. The Zn concentrations in plant indicated that in the calcareous soil, new applications of Zn are desirable in subsequent crops to maintain suitable concentrations in plant. 15 The highest concentrations of Zn in navy bean plant, performed under moisture conditions above the field capacity, were obtained with the residual effect of Zn-HEDTA at the dose of 10 mg Zn kg-1 (280.87 mg Zn kg-1) in the acid soil, and with the residual effect of Zn- DTPA-HEDTA-EDTA at a dose of 10 mg Zn kg-1 (49.89 mg Zn kg-1) in the calcareous soil. In the flax crop, performed under moisture conditions below field capacity, the highest Zn concentrations in plant were obtained with the residual effect of Zn-AML at the dose of 10 mg Zn kg-1 (224.75 Zn mg kg-1) and with the residual effect of Zn-EDTA at a dose of 10 mg Zn kg-1 (99.83 mg Zn kg-1) in the calcareous soil. The Zn uptake was determined as a combination of yield and Zn concentration in plant. Under moisture conditions above field capacity, with leaching, Zn uptake by navy bean decreased in the current crop, respect to the previous crop. However, in the flax crop, under moisture conditions below field capacity, Zn uptake was higher in the current crop than in the previous. This trend is also observed in both cases, with the percentage of Zn used by the plant