3 resultados para Electric lines.

em Universidad Politécnica de Madrid


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The location of ground faults in railway electric lines in 2 × 5 kV railway power supply systems is a difficult task. In both 1 × 25 kV and transmission power systems it is common practice to use distance protection relays to clear ground faults and localize their positions. However, in the particular case of this 2 × 25 kV system, due to the widespread use of autotransformers, the relation between the distance and the impedance seen by the distance protection relays is not linear and therefore the location is not accurate enough. This paper presents a simple and economical method to identify the subsection between autotransformers and the conductor (catenary or feeder) where the ground fault is happening. This method is based on the comparison of the angle between the current and the voltage of the positive terminal in each autotransformer. Consequently, after the identification of the subsection and the conductor with the ground defect, only the subsection where the ground fault is present will be quickly removed from service, with the minimum effect on rail traffic. This method has been validated through computer simulations and laboratory tests with positive results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A quasisteady model for the plasma ablated from a thick foil by a laser pulse, at low $lln $ and R /A i within a low, narrow range, is given (4, is absorbed intensity, /zL wavelength, R focalspot radius). An approximate analytical solution is given for the two-dimensional plasma dynamics. At large magnetic Reynolds number Rm, the morphology of the magnetic field shows features in agreement with recent results for high intensities. Current lines are open: electric current flows toward the spot near its axis, then turns and flows away. The efficiency of converting light energy into electric energy peaks at Rm- 1, both the validity of the model. and accuracy of the solution are discussed, The neighborhood of the spot boundary is analyzed in detail by extending classical Prandtl-Meyer results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Damages -reduced in fruit packing lines is a major cause of grace reduction and quality loos in fresh marks: fruit. Fruit must be treated gently during in sir handling to improve their qualityin order to get a good price in a competitive market. The correct post-hardvest handling in fruit packing lines is a prerequisite to cut down the heavy post-harvest losses. Fruit packing lines must be evaluated, studying their design, the impacts applied to the fruits, the characteristics of the materials, etc. This study establishes the possibility of carrying out modifications and tests in a packing line during a long period of time. For this purpose, an experimental fruit packing line has been designed and located in the Agricultural Engineering Department of the Polythecnic University of Madrid with the aim of improving mechanical devices and fruit handling conditions to minimize damage to fruit. The experimental line consists of several transporting belts, one rollers transporter, one sizer, one elevator, one singularizer, and three trays to receive the calibrated fruit. The line has a length of 6.15 m and a width cf 1.9 m. Movement of the different components is regulated by electric motors with variable velocity electronically controlled. The height of the transfer points is variable and can be easily modified. The experimental line has been calibrated using two instrumented spheres IS 100 (8.8 cm Ø and6.2cm Ø). Average acceleration values obtained in all the transfers of the experimental line lay under 80 g's, although there is big variation for some of them being some values above 100 g's.