7 resultados para Bruininks-Oseretsky Test of Motor Proficiency II
em Universidad Politécnica de Madrid
Resumo:
The new requirement placed on students in tertiary settings in Spain to demonstrate a B1 or a B2 proficiency level of English, in accordance with the Common European Framework of Reference for Languages (CEFRL), has led most Spanish universities to develop a program of certification or accreditation of the required level. The first part of this paper aims to provide a rationale for the type of test that has been developed at the Universidad Politécnica de Madrid for the accreditation of a B2 level, a multiple choice version, and to describe how it was constructed and validated. Then, in the second part of the paper, the results from its application to 924 students enrolled in different degree courses at a variety of schools and faculties at the university are analyzed based on a final test version item analysis. To conclude, some theoretical as well as practical conclusions about testing grammar that affect the teaching and learning process are drawn. RESUMEN. Las nuevas exigencias sobre niveles de competencia B1 y B2 en inglés según el Marco Común Europeo de Referencia para las Lenguas (MCERL) que se imponen sobre los estudiantes de grado y posgrado han llevado a la mayoría de las universidades españolas a desarrollar programas de acreditación o de certificación de estos niveles. La primera parte de este trabajo trata sobre las razones que fundamentan la elección de un tipo concreto de examen para la acreditación del nivel B2 de lengua inglesa en la Universidad Politécnica de Madrid. Se trata de un test de opción múltiple y en esta parte del trabajo se describe cómo fue diseñado y validado. En la segunda parte, se analizan los resultados de la aplicación del test a gran escala a un total de 924 estudiantes matriculados en varias escuelas y Facultades de la Universidad. Para terminar, se apuntan una serie de conclusiones teóricas y prácticas sobre la evaluación de la gramática y de qué modo influye en los procesos de enseñanza y aprendizaje.
Resumo:
A small Positron Emission Tomography demonstrator based on LYSO slabs and Silicon Photomultiplier matrices is under construction at the University and INFN of Pisa. In this paper we present the characterization results of the read-out electronics and of the detection system. Two SiPM matrices, composed by 8 × 8 SiPM pixels, 1.5 mm pitch, have been coupled one to one to a LYSO crystals array. Custom Front-End ASICs were used to read the 64 channels of each matrix. Data from each Front-End were multiplexed and sent to a DAQ board for the digital conversion; a motherboard collects the data and communicates with a host computer through a USB port. Specific tests were carried out on the system in order to assess its performance. Futhermore we have measured some of the most important parameters of the system for PET application.
Resumo:
This study investigated the changes in cardiorespiratory response and running performance of 9 male ?Talent Identification? (TID) and 6 male Senior Elite (SE) Spanish National Squad triathletes during a specific cycle-run test. The TID and SE triathletes (initial age 15.2±0.7 vs. 23.8±5.6 years, p=0.03; tests through the competitive period and the preparatory period, respectively, of two consecutive seasons: Test 1 was an incremental cycle test to determine the ventilatory threshold (Thvent); Test 2 (C-R) was 30 min constant load cycling at the Thvent power output followed by a 3-km time trial run; and Test 3 (R) was an isolated 3-km time trial control run, in randomized counterbalanced order. In both seasons the time required to complete the C-R 3-km run was greater than for R in TID (11:09±00:24 vs. 10:45±00:16 min:ss, pmenor que 0.01; and 10:24±00:22 vs. 10:04±00:14, p=0.006, for season 2005/06 and 2006/07, respectively) and SE (10:15±00:19 vs. 09:45±00:30, pmenor que 0.001 and 09:51±00:26 vs. 09:46±00:06, p= 0.02 for season 2005/06 and 2006/07, respectively). Compared to the first season, completion of the time trial run was faster in the second season (6.6%, pmenor que 0.01 and 6.4%, pmenor que 0.01, for C-R and R test, respectively) only in TID. Changes in post-cycling run performance were accompanied by changes in pacing strategy but only slight or non-significant changes in the cardiorespiratory response. Thus, the negative effect of cycling on performance may persist, independently of the period, over two consecutive seasons in TID and SE triathletes; however A improvements over time suggests that monitoring running pacing strategy after cycling may be a useful tool to control performance and training adaptations in TID. O2max 77.0±5.6 vs. 77.8±3.6 mL·kg-1·min-1, NS) underwent three TE D EP C C
Resumo:
Communications Based Train Control Systems require high quality radio data communications for train signaling and control. Actually most of these systems use 2.4GHz band with proprietary radio transceivers and leaky feeder as distribution system. All them demand a high QoS radio network to improve the efficiency of railway networks. We present narrow band, broad band and data correlated measurements taken in Madrid underground with a transmission system at 2.4 GHz in a test network of 2 km length in subway tunnels. The architecture proposed has a strong overlap in between cells to improve reliability and QoS. The radio planning of the network is carefully described and modeled with narrow band and broadband measurements and statistics. The result is a network with 99.7% of packets transmitted correctly and average propagation delay of 20ms. These results fulfill the specifications QoS of CBTC systems.
Resumo:
Specific tests to assess reliability of high luminosity AlInGaP LED for outdoor applications are needed. In this paper tests to propose a model involving three parameters: temperature, humidity and current have been carried out. Temperature, humidity and current accelerated model has been proposed to evaluate the reliability of this type of LED. Degradation and catastrophic failure mechanisms have been analyzed. Finally we analyze the effect of serial resistance in power luminosity degradation.
Resumo:
This research investigates the ultimate earthquake resistance of typical RC moment resisting frames designed accordingly to current standards, in terms of ultimate energy absorption/dissipation capacity. Shake table test of a 2/5 scale model, under several intensities of ground motion, are carried out. The loading effect of the earthquake is expressed as the total energy that the quake inputs to the structure, and the seismic resistance is interpreted as the amount of energy that the structure dissipates in terms of cumulative inelastic strain energy.
Resumo:
Los pernos conectores aportan múltiples ventajas de uso, entre las que se encuentra el elevado margen de seguridad que ofrecen sus soldaduras ejecutadas mediante arco eléctrico. Estas soldaduras, aunque ampliamente fiables, son difícilmente comprobadas mediante ensayos no destructivos. Aparte de la inspección visual, que aporta gran información sobre la calidad de ejecución de la soldadura, el resto de ensayos no destructivos (líquidos penetrantes, partículas magnéticas, ultrasonidos, radiografías, etc.) resultan inviables en estos elementos. Por otro lado, los ensayos acústicos de piezas metálicas han existido siempre. Su comprobación se basaba en el análisis por medio de ¿un oído fino¿ del sonido resultante tras ser golpeado el elemento a evaluar. Con estas premisas se plantea el presente estudio de inspección de las soldaduras en pernos conectores mediante su espectro acústico. Analíticamente, la investigación se ha centrado en el cálculo informático de los primeros modos propios de vibración mediante elementos finitos. Se han modelizado diferentes grados de penetración de la soldadura mediante la modificación de las condiciones de contorno. Se ha observado que variando el número de movimientos coaccionados en los nodos pertenecientes a la soldadura se produce una reducción en su frecuencia de vibración.