11 resultados para AC generators

em Universidad Politécnica de Madrid


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The increasing penetration of wind energy into power systems has pushed grid operators to set new requirements for this kind of generating plants in order to keep acceptable and reliable operation of the system. In addition to the low voltage ride through capability, wind farms are required to participate in voltage support, stability enhancement and power quality improvement. This paper presents a solution for wind farms with fixed-speed generators based on the use of STATCOM with braking resistor and additional series impedances, with an adequate control strategy. The focus is put on guaranteeing the grid code compliance when the wind farm faces an extensive series of grid disturbances.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Renewable energy hybrid systems and mini-grids for electrification of rural areas are known to be reliable and more cost efficient than grid extension or only-diesel based systems. However, there is still some uncertainty in some areas, for example, which is the most efficient way of coupling hybrid systems: AC, DC or AC-DC? With the use of Matlab/Simulink a mini-grid that connects a school, a small hospital and an ecotourism hostel has been modelled. This same mini grid has been coupled in the different possible ways and the system’s efficiency has been studied. In addition, while keeping the consumption constant, the generation sources and the consumption profile have been modified and the effect on the efficiency under each configuration has also been analysed. Finally different weather profiles have been introduced and, again, the effect on the efficiency of each system has been observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper analyzes the correlation between the fluctuations of the electrical power generated by the ensemble of 70 DC/AC inverters from a 45.6 MW PV plant. The use of real electrical power time series from a large collection of photovoltaic inverters of a same plant is an impor- tant contribution in the context of models built upon simplified assumptions to overcome the absence of such data. This data set is divided into three different fluctuation categories with a clustering proce- dure which performs correctly with the clearness index and the wavelet variances. Afterwards, the time dependent correlation between the electrical power time series of the inverters is esti- mated with the wavelet transform. The wavelet correlation depends on the distance between the inverters, the wavelet time scales and the daily fluctuation level. Correlation values for time scales below one minute are low without dependence on the daily fluctuation level. For time scales above 20 minutes, positive high correlation values are obtained, and the decay rate with the distance depends on the daily fluctuation level. At intermediate time scales the correlation depends strongly on the daily fluctuation level. The proposed methods have been implemented using free software. Source code is available as supplementary material.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The cutoff frequencies of an EMI filter are normally given by the noise attenuation requirements the filter has to fulfill. In order to select the component values of the filter elements, i.e. inductances and capacitances, an additional design criterium is needed. In this paper the effect of the EMI filter input and output impedances are considered. The input impedance influences the filters effect on the system displacement power factor and the output impedance plays a key role in the system stability. The effect of filter element values, the number of filter stages as well as additional damping networks are considered and a design procedure is provided. For this analysis a two-port description of the input filters employing ABCD-parameters is used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El objeto de esta construcción es un Viaducto que permite salvar la carretera de Baños de Arteixo, ofreciendo una continuidad al trazado de la Tercera Ronda y separando el tráfico entre ambas. La Tercera Ronda es una vía de circulación que permite rodear la ciudad de A Coruña, comunicando diferentes zonas de la ciudad y permitiendo la conexión con la AC-552, AG-55 y A-6, desahogando así el tráfico de las principales calles de la ciudad y despejando el centro de la misma. Esta obra supone alcanzar una serie de objetivos generales que se pueden concretar en que constituye una nueva alternativa de circulación gratuita y un acceso rápido y cómodo al Centro Comercial Marineda, a cuantos allí acuden y a todas las empresas y compañías con sus negocios allí instalados.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Among all the different types of electric wind generators, those that are based on doubly fed induction generators, or DFIG technology, are the most vulnerable to grid faults such as voltage sags. This paper proposes a new control strategy for this type of wind generator, that allows these devices to withstand the effects of a voltage sag while following the new requirements imposed by grid operators. This new control strategy makes the use of complementary devices such as crowbars unnecessary, as it greatly reduces the value of currents originated by the fault. This ensures less costly designs for the rotor systems as well as a more economic sizing of the necessary power electronics. The strategy described here uses an electric generator model based on space-phasor theory that provides a direct control over the position of the rotor magnetic flux. Controlling the rotor magnetic flux has a direct influence on the rest of the electrical variables enabling the machine to evolve to a desired work point during the transient imposed by the grid disturbance. Simulation studies have been carried out, as well as test bench trials, in order to prove the viability and functionality of the proposed control strategy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a comprehensive review of stepup single-phase non-isolated inverters suitable for ac-module applications. In order to compare the most feasible solutions of the reviewed topologies, a benchmark is set. This benchmark is based on a typical ac-module application considering the requirements for the solar panels and the grid. The selected solutions are designed and simulated complying with the benchmark obtaining passive and semiconductor components ratings in order to perform a comparison in terms of size and cost. A discussion of the analyzed topologies regarding the obtained ratings as well as ground currents is presented. Recommendations for topological solutions complying with the application benchmark are provided.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In weak grids, an important problem with voltage stability and protections coordination of power plants exists. This problem appears because all the generation groups are connected to the same bus bar. As a result, if a fault occurs in any of the generation groups, or in the bus bar that connect them, the system voltage will have large oscillations. Hence, in weak grids the correct adjustment of AVR (Automatic Voltage Regulator) is critical. In this work an experimental study of differents AVR adjustments against fault in weak grids is described.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Locating stator-winding ground faults accurately is a very difficult task. In this paper the grounding circuit measurements are evaluated in order to obtain information about the stator ground-fault location in synchronous generators. In power generators grounded through a high impedance, the relation between the neutral voltage and the phase voltage provide a first estimation of the fault location. The location error by using this ratio depends on the fault resistance and the value of the capacitance to ground of the stator winding. However, the error added by ignoring the value of the fault resistance is the most relevant term. This location estimation and the location error have been evaluated through the data of a real synchronous machine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The generator differential protection is one of the most important electrical protections of synchronous generator stator windings. Its operation principle is based on the comparison of the input current and output current at each phase winding. Unwanted trip commands are usually caused by CT saturation, wrong CT selection, or the fact that they may come from different manufacturers. In generators grounded through high impedance, only phase-to-phase or three-phase faults can be detected by the differential protection. This kind of fault causes differential current to flow in, at least, two phases of the winding. Several cases of unwanted trip commands caused by the appearance of differential current in only one phase of the generator have been reported. In this paper multi-phase criterion is proposed for generator differential protection algorithm when applied to high impedance grounded generators.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The search for new energy models arises as a necessity to have a sustainable power supply. The inclusion of distributed generation sources (DG) allows to reduce the cost of facilities, increase the security of the grid or alleviate problems of congestion through the redistribution of power flows. In remote microgrids it is needed in a particular way a safe and reliable supply, which can cover the demand for a low cost; due to this, distributed generation is an alternative that is being widely introduced in these grids. But the remote microgrids are especially weak grids because of their small size, low voltage level, reduced network mesh and distribution lines with a high ratio R/X. This ratio affects the coupling between grid voltages and phase shifts, and stability becomes an issue of greater importance than in interconnected systems. To ensure the appropriate behavior of generation sources inserted in remote microgrids -and, in general, any electrical equipment-, it is essential to have devices for testing and certification. These devices must, not only faithfully reproduce disturbances occurring in remote microgrids, but also to behave against the equipment under test (EUT) as a real weak grid. This also makes the device commercially competitive. To meet these objectives and based on the aforementioned, it has been designed, built and tested a voltage disturbances generator, in order to provide a simple, versatile, full and easily scalable device to manufacturers and laboratories in the sector.