53 resultados para Underground


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The study of the many types of natural and manmade cavities in different parts of the world is important to the fields of geology, geophysics, engineering, architectures, agriculture, heritages and landscape. Ground-penetrating radar (GPR) is a noninvasive geodetection and geolocation technique suitable for accurately determining buried structures. This technique requires knowing the propagation velocity of electromagnetic waves (EM velocity) in the medium. We propose a method for calibrating the EM velocity using the integration of laser imaging detection and ranging (LIDAR) and GPR techniques using the Global Navigation Satellite System (GNSS) as support for geolocation. Once the EM velocity is known and the GPR profiles have been properly processed and migrated, they will also show the hidden cavities and the old hidden structures from the cellar. In this article, we present a complete study of the joint use of the GPR, LIDAR and GNSS techniques in the characterization of cavities. We apply this methodology to study underground cavities in a group of wine cellars located in Atauta (Soria, Spain). The results serve to identify construction elements that form the cavity and group of cavities or cellars. The described methodology could be applied to other shallow underground structures with surface connection, where LIDAR and GPR profiles could be joined, as, for example, in archaeological cavities, sewerage systems, drainpipes, etc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este documento presenta los parámetros necesarios referentes a la ventilación de una mina subterránea, la normativa aplicable a este tipo de instalaciones, así como los procedimientos e instrumentación básicos para la medida de aforos. Todo ello va encaminado a cuantificar el circuito de ventilación de una mina subterránea para realizar de forma eficiente una modelización de la ventilación. Se presenta además un caso práctico de simulación optimizada a partir de parámetros para una ampliación de un nuevo nivel en una explotación. Esta optimización está caracterizada de forma económicamente eficiente. This paper presents the necessary parameters concerning ventilation of an underground mine, the regulations applicable to such facilities and basic procedures and instrumentation for measuring capacities. All of this is aimed at quantifying the ventilation circuit of an underground minefor efficiently modeling of ventilation. A case of optimized simulation is also presented based on parameters for amplifying a new level in an underground mine. This optimization is economically characterized on an efficient way.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a mechanism to generate virtual buildings considering designer constraints and guidelines. This mechanism is implemented as a pipeline of different Variable Neighborhood Search (VNS) optimization processes in which several subproblems are tackled (1) rooms locations, (2) connectivity graph, and (3) element placement. The core VNS algorithm includes some variants to improve its performance, such as, for example constraint handling and biased operator selection. The optimization process uses a toolkit of construction primitives implemented as "smart objects" providing basic elements such as rooms, doors, staircases and other connectors. The paper also shows experimental results of the application of different designer constraints to a wide range of buildings from small houses to a large castle with several underground levels.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Esta tesis pretende demostrar que las bodegas subterráneas suponen un modelo de construcción eficiente y medioambientalmente sostenible para la crianza y el almacenamiento de vinos. Durante la elaboración, crianza y almacenamiento del vino, las condiciones de temperatura y humedad relativa son determinantes en la calidad final del producto. La aparición de defectos en el vino como consecuencia de altas temperaturas durante el proceso crianza es algo conocido desde el siglo pasado, por lo que los enólogos tratan de alcanzar los parámetros que consideran idóneos para una correcta elaboración y envejecimiento del vino recurriendo en la mayoría de las bodegas a la climatización artificial. Las bodegas subterráneas son construcciones históricas en La Rioja y en el conjunto de los pueblos de la Denominación de Origen Calificada Rioja y el objetivo de esta tesis es demostrar que reúnen de forma natural las condiciones idóneas para la crianza del vino debido al diseño de su construcción y sin necesidad de emplear otras energías para conseguirlo. Además, la presencia de estas construcciones en la Denominación de Origen Calificada Rioja supone el origen de la fama de sus caldos y es un patrimonio cultural hoy en día sin explotar. Para demostrar la importancia de estos barrios de bodegas subterráneas, germen de la Denominación de Origen Calificada Rioja, se han inventariado los barrios de todos los municipios acogidos a ésta. Para ello se han visitado todos los municipios y se han fotografiado sus bodegas. En las visitas realizadas durante la catalogación se ha observado que constituyen hoy en día un patrimonio olvidado, que ha evolucionado hacia merenderos o viviendas, incluso en ocasiones abandonadas o derruidas. La conservación de las construcciones se ha cuidado más en la subzona de Rioja Alta, donde aún se pueden encontrar bodegas donde se elabora vino de forma particular, algo más excepcional de encontrar en La Rioja Baja. También se ha observado que los materiales de construcción de los calados empleados en La Rioja Alta suelen ser de piedra labrada o de sillería, mientras que en La Rioja Baja se recurre más a piedra de río o mampostería. Este trabajo se refleja en 2159 fichas que catalogan las bodegas subterráneas localizadas. Con objeto de demostrar que reúnen las condiciones adecuadas para la crianza, se han instalado sensores que han registrado la temperatura y la humedad relativa en las bodegas subterráneas y en bodegas comerciales de las que se diferencian tanto en el diseño constructivo como en las soluciones adoptadas por estas para reunir los parámetros buscados. Los resultados obtenidos en las bodegas subterráneas muestran que estas construcciones tradicionales presentan menos oscilaciones anuales de temperatura y humedad relativa que las salas de crianza de bodegas comerciales, lo que implica una solución constructiva más adecuada para la crianza y conservación del vino. Para corroborar los resultados obtenidos sobre las condiciones interiores, se ha realizado un análisis sensorial de vinos almacenados y criados en bodegas subterráneas comparándolos con los almacenados sin estar sometidos a un control de estos parámetros, como se puede dar en condiciones domésticas, una vez comercializados cuando el enólogo pierde el control sobre ellos. Los resultados demuestran que los vinos almacenados en domicilios particulares presentan diferencias con los almacenados en bodegas subterráneas. Estos resultados son acordes con los datos obtenidos de los sensores colocados en estas bodegas subterráneas, donde la temperatura máxima anual no supera los 20ºC, considerada como umbral máximos permitido durante la crianza por varios autores. ABSTRACT This thesis aims to demonstrate that the underground cellars represent a model of efficient construction and environmentally sustainable for aging and storing wines. During the production, aging and storing wine, temperature and relative humidity are crucial to the final product quality. The appearance of defects in wine as a result of high temperatures during the aging process is something known since the last century, so that winemakers seek to achieve the parameters considered suitable for proper production and aging of wine using the most wineries to artificial air conditioning. The underground cellars are historical buildings in La Rioja and all the peoples of the Designation of Origin Rioja and the aim of this thesis is to demonstrate that naturally meet the conditions for aging wine due to its construction design and without the use of other energy to get it. Furthermore, the presence of these buildings in the Rioja Denomination of Origin represents the origin of the fame of its wines and is a cultural heritage today untapped. To demonstrate the importance of these areas of underground cellars, germ of the Designation of Origin Rioja, they have been inventoried all the districts of municipalities benefiting from this. This will have visited all municipalities and have photographed their cellars. In visits made during cataloging it has been observed that constitute today a forgotten heritage that has evolved to picnic or homes, sometimes even abandoned or demolished. The conservation of the buildings has been more careful in the subzone of Rioja Alta, where you can still find wine cellars where a particular way, something exceptional to find in La Rioja Baja is made. It has also been observed that the building materials used in the drafts La Rioja Alta usually carved stone or masonry, while in La Rioja Baja is most uses of river stone or masonry. This work is reflected in 2159 cataloging records located underground cellars. In order to demonstrate that they meet the conditions suitable for breeding they were installed sensors that recorded the temperature and relative humidity in the underground cellars and commercial wineries which differ both in the building design and the solutions adopted by sought to gather these parameters. The results obtained in the underground cellars show that these traditional buildings have fewer annual fluctuations of temperature and relative humidity of the aging rooms commercial wineries, which implies a more constructive solution suitable for the breeding and conservation of wine. To corroborate the results obtained on domestic conditions, has made a sensory analysis of wines stored and raised underground cellars compared with stored without being subjected to control these parameters, as can occur in domestic conditions, once marketed as winemaker loses control over them. The results show that the wines stored in private homes have differences with those stored in underground cellars. These results are consistent with data obtained from sensors placed in these underground cellars, where the maximum annual temperature is below 20 ° C, considered as maximum allowable threshold for raising by various authors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Las fuentes como parte de la ingeniería hidráulica, quizás menor, de nuestro país son elementos urbanos, funcionales y de gran interés en el pasado, que poco a poco han ido en decadencia desde la traída de aguas domiciliares. No obstante, entre nosotros, hay magníficas obras de ingeniería muy bien estudiadas y ejecutadas técnicamente pero que a la par representan elementos artísticos de gran interés y representatividad. No en vano en la última ley de Patrimonio Histórico Artístico de la Comunidad de Madrid (ley 3/2013), se requiere su estudio y catalogación a nivel municipal. La técnica de su diseño, es bien conocida desde muy antiguo. Ya los romanos hacían uso de una precisión milimétrica para el cálculo de las pendientes de las conducciones subterráneas que llevaban el agua intacta hasta su destino tras recorrer decenas de kilómetros sin necesidad de energía externa para ello. La calidad de sus aguas, muy ligada al sustrato determinaba en gran medida asentamientos y usos que según su popularidad, podían incluso restringirse a distintos niveles sociales La obra arquitectónica asociada, también cobraba especial relevancia por su singularidad, monumentalidad y aspecto. Muchas son las tendencias arquitectónicas que se dan cita en las fuentes estudiadas, que además, encierran tras de sí gran riqueza de carácter histórico. Esta investigación se centra en el inventariado, catalogación y caracterización de una muestra representativa de fuentes naturales madrileñas (550 fuentes), el estudio pormenorizado de las variables utilizadas en su caracterización, a través de tratamientos inferenciales, y el diseño experimental “ad hoc” de una propuesta metodológica de catalogación y caracterización 360° (desde la captación hasta la salida de aguas por el caño). La investigación finaliza con la puesta en práctica de la metodología diseñada, a través del estudio, catalogación y caracterización de un caso concreto. La presente investigación se centra en la Comunidad de Madrid, pero la propuesta metodológica que se propone como aportación, es extrapolable a cualquier tipo de fuente en cualquier municipio. Con todo ello, se pretende poner en valor estas obras de ingeniería ignorada, y contribuir de alguna forma a su preservación, facilitando su catalogación y difundiendo su existencia. As a minor relevant part of hydraulic engineering, the fountains of our country are urban, functional and of great interest in the past. The relevancy of these fountains has gradually declined since the emergence of general water supply. However, in our environment, there are magnificent works of engineering very well studied and executed, that also represent good examples of art and historical interest. In this way, the Historical and Artistic Heritage Law of the Community of Madrid (Ley 3/2013), requests the councils, their study and categorization. Their technical design is well known since ancient times. Even the Romans were able to use pinpoint accuracy (just a few millimeters), to calculate the slopes of the underground pipes which supply water, in perfect conditions, to its target, and without using external sources of energy. In this cases, the water quality of which was obviously linked to the type of substrate, conditioned the settlements and even its use, that could be restricted to certain social classes. In some cases, the engineering works of these fountains were especially relevant for its uniqueness, monumentality and appearance. There are many architectural trends that come together in the studied fountains, which also contain of its own historical character. This research is focused on inventory categorization and characterization of a representative sample of 550 natural fountains in Madrid. It includes the detailed study of the variables used in its characterization, through inferential treatments, and the "ad hoc" experimental design of a methodology for the categorization and a 360 ° characterization, from the catchment to the spout. Finally, the research ends with the implementation of the designed methodology, through the study, categorization and characterization of a specific case. Although this research is focused on fountains from Madrid surroundings, the main value is that the purposed methodology can be extrapolated to to manyother cases. To highlight these ignored engineering works, and contribute to its preservation making easier their categorization and spreading their existence, set the main aim of this research.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El rápido desarrollo industrial y el crecimiento de la población en cada país conllevan a la disposición de obras o edificaciones para satisfacer las necesidades; de vivienda, de vías de comunicación o de instalaciones industriales entre otras. Para la construcción de obras se plantean posibles sistemas de cimentación que incluyen; zapatas o losas de hormigón armado cuando superficialmente el terreno es competente y pilotes o sistema placa pilotes de hormigón armado cuando el terreno superficial es poco competente. Las cimentaciones por pilotes o definidas como profundas cuando L/D>6, se han construido en diferentes tipologías de materiales como madera, acero y hormigón armado, de secciones circulares, rectangulares, anulares y tipo H y de forma de inclusión en el terreno como hincados y Excavados a veces estos últimos también llamados preexcavados. Cada aspecto anterior en un diseño aborda consideraciones y restricciones, las cuales han sido definidas por la mecánica de suelos, la experiencia o por ensayos característicos, y que en cierta forma inciden en el procedimiento para determinar la carga de hundimiento o carga en el pilote equivalente a la resistencia ultima del terreno. En la literatura técnica existen muchos procedimientos para determinar la carga de hundimiento de cimentaciones profundas con pilotes. Estos procedimientos se definen en artículos, guías, manuales o normas. Entre todas ellas se seleccionarán algunas y para cada una de ellas se identificará cual es el enfoque, que parámetros son más representativos, cuales son las limitaciones o si se definen dentro de la misma norma otros procedimientos alternativos que se basan en resultados de otros ensayos característicos en geotecnia. Por tanto, el objeto del trabajo tiene como alcance comparar los distintos procedimientos de determinación de carga de hundimiento que vienen recogidos en las normas de mayor difusión en España y el manual del INVÍAS de Colombia. Las diferencias de cada uno de los procedimientos definidos en esta investigación se representarán analizando un ejemplo teórico y realizando graficas que muestren claramente las diferencias entre uno y otro. La estructura del trabajo se divide en cuatro fases, la primera la revisión bibliográfica y estado del arte, la segunda el análisis normativo y la determinación de la carga de hundimiento para un ejemplo teórico, con las diferentes metodologías definidas en Código Técnico de Edificación (CTE 2007), Guía de cimentaciones de obras de carreteras (GCOC 2003), Recomendaciones para Obras Marítimas (ROM 0.5‐5) y Manual de Cimentaciones superficiales y profundas – Colombia 2012, en la tercera etapa se indica los resultados y evaluación de las metodologías establecidas en valores de resistencia por punta, por fuste o resistencia global, y en la cuarta y última etapa se presentan las conclusiones y recomendaciones. De la revisión bibliográfica enmarcada en el capítulo 1 se obtuvieron buenas referencias sobre metodologías de cálculo, en este capítulo se mencionan y se presentan los aspectos básicos, y consideraciones más relevantes. La normatividad Europea enfatiza los criterios de cálculo en base a resultados de ensayos de campo adecuados como el CPTU (por sus siglas en inglés Cone Penetration Test with Pressure water Underground) y el presiómetro, ya que se obtiene valores en condiciones reales y no de modelos de laboratorio, lamentablemente en países en vías de desarrollo el temor a uso de estos métodos es básicamente por falta de experiencia y costo de los mismos. La optimización de los diseños de construcción de obras civiles permite reducir costos de ejecución y materiales, y estará siempre ligado a un buen control de ensayos sobre el suelo como de procedimientos de ejecución. La validez de los métodos solo será definida por el estado del arte, el tipo de suelo, el tipo de estructura, y en cada nuevo proyecto se deberá tener como mínimo esta información de cimentaciones regionales. Las normas definidas colocan en consideración varios métodos y de alguna forma proponen recomendaciones de diseño para reducir los posibles errores, esto puede lograrse al realizar los análisis por lo menos por un método analítico y por uno empírico. Lo anterior conlleva a que la exploración geotécnica sea redundante pero precisa.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Los ensayos de bombeo son, sin lugar a dudas, una de las pruebas más fiables y de mayor interés que se hacen en el medio físico. No son pruebas estrictamente puntuales, dado que el bombeo atrae flujo desde distancias lejanas al pozo, la prueba tiene una excelente representatividad espacial. Los métodos de interpretación mediante ensayos de bombeo se empezaron a plantear en la primera mitad del pasado siglo. Con los ensayos de bombeo se puede calcular la transmisividad y coeficiente de almacenamiento de las formaciones acuíferas y suministran información sobre el tipo de acuífero, la calidad constructiva del pozo de extracción, la existencia de barreras impermeable o bordes de recarga próximos, e incluso en algunas circunstancias permiten el cálculo del área de embalse subterráneo. Desde mediados del siglo 20 existe una eficaz y abundante gama de métodos analítico-interpretativos de ensayos de bombeo, tanto en régimen permanente como transitorio. Estos métodos son ampliamente conocidos y están muy experimentados a lo largo de muchos países, sin embargo, hoy día, podrían utilizarse modelos de flujo para la interpretación, logrando la misma fiabilidad e incluso mejores posibilidades de análisis. Muchos ensayos que no pueden interpretarse porque las configuraciones del medio son demasiado complejas y no están disponibles, o no es posible, el desarrollo de métodos analíticos, tienen buena adaptación y en ocasiones muy fácil solución haciendo uso de los métodos numéricos de simulación del flujo. En esta tesis se ha buscado una vía de interpretar ensayos de bombeo haciendo uso de modelos de simulación del flujo. Se utiliza el modelo universal MODFLOW del United States Geological Survey, en el cual se configura una celda de simulación y mallado particularmente adecuados para el problema a tratar, se valida con los métodos analíticos existentes. Con la célula convenientemente validada se simulan otros casos en los que no existen métodos analíticos desarrollados dada la complejidad del medio físico a tratar y se sacan las oportunas conclusiones. Por último se desarrolla un modelo específico y la correspondiente aplicación de uso general para la interpretación numérica de ensayos de bombeo tanto con las configuraciones normales como con configuraciones complejas del medio físico. ABSTRACT Pumping tests are, without doubt, one of the most reliable and most interesting tests done in the physical environment. They are not strictly anecdotal evidence, since pumping flow attracts from far distances to the well, the test has excellent spatial representation. Methods of interpretation by pumping tests began to arise in the first half of last century. With pumping tests, can be calculated transmissivity and storage coefficient of the aquifer formations, and provide information on the type of aquifer, the construction quality of the well, the existence of waterproof barriers or borders next recharge, and even in some circumstances allow calculating the area of underground reservoir. Since the mid-20th century there is effective and abundant range of analytical interpretative pumping tests, both in steady state and transient methods. These methods are very widely known and experienced over many countries, however, nowadays, may flow models used for interpretation, obtaining equally reliable or even better possibilities for analysis. Many trials cannot be interpreted as environmental settings are too complex and are not available, or not possible, the development of analytical methods, have good adaptation and sometimes very easily solved using numerical flow simulation methods. This thesis has sought a way to interpret pumping tests using flow simulation models. MODFLOW universal model of United States Geological Survey, in which a simulation cell and meshing particularly suitable for the problem to be treated, is validated with existing analytical methods used is set. With suitably validated cell other cases where there are no analytical methods developed given the complexity of the physical environment to try and draw appropriate conclusions are simulated. Finally, a specific model and the corresponding application commonly used for numerical interpretation of pumping tests both with normal settings as complex configurations of the physical environment is developed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis presents the study carried out at an underground mine to understand the stress distribution in the paste fills and to calculate the stability of the paste walls in the primary and secondary stopes. The mine is operated using sublevel stopes and fan blasting. The primary and secondary stopes are 20m wide, 30m high and between 20 and 60m long. Three-dimensional numerical models designed with the FLAC 3D software programme are used to study the distribution of the vertical stresses in the paste walls exposed in the primary and secondary stopes, and their evolution as the mining advance increases. The numerical models have demonstrated that an arc-like effect is produced in the paste fills of the primary stopes, that is, those which have either lateral walls in mineral or rock. This effect relieves the vertical stresses and increases the stability of the exposed paste wall fill. From the study, it is deduced that in this type of stope, the fill stability can be calculated using the formula established by Mitchell, (Mitchell, Olsen, and Smith 1982, 14-28). Based on the results of the numerical models, in the 30m high secondary stopes, the arc effect starts to be evident only in paste walls with a width/height ratio lower than 0.7. 3-D calculations show that the use of Mitchell formula may be risky when estimating the fill stability in secondary stopes. Therefore, in these cases, the traditional two-dimensional method for calculating the stability of vertical slopes on cohesive saturated soils in the short term should be used. However this method may give conservative results for paste walls in secondary stopes with a width/height ratio below 0.5. RESUMEN Esta Tesis presenta el estudio realizado en la mina subterránea de Aguas Teñidas (Huelva, España) para comprender la distribución de tensiones en los rellenos de pasta y calcular la estabilidad de las paredes de pasta en las cámaras primarias y secundarias. El método de explotación utilizado en esta mina es el de cámaras con subniveles y voladura en abanico. Las cámaras primarias y secundarias tienen una anchura de 20 m, una altura de 30 m y una longitud variable entre 20 y 60 m. Mediante modelos numéricos tridimensionales realizados con el programa FLAC 3D se ha estudiado la distribución de las tensiones verticales en las paredes de pasta que quedan expuestas en las cámaras primarias y secundarias, y su evolución a medida que aumenta la superficie explotada. La modelización numérica ha puesto de manifiesto que se produce efecto arco en los rellenos de pasta de las cámaras primarias, o sea, aquellas que tienen ambos hastiales en mineral o en roca. Este efecto aligera las tensiones verticales y aumenta la estabilidad del relleno de la pared de pasta expuesta. De acuerdo con los resultados de los modelos numéricos, en las cámaras secundarias de 30 m de alto, el efecto arco empieza a manifestarse solamente en las paredes de pasta de relación anchura/altura menor de 0,7. Los cálculos realizados en tres dimensiones indican que la fórmula de Mitchell (Mitchell, Olsen, y Smith 1982, 14-28) puede resultar arriesgada para estimar la estabilidad del relleno en este tipo de cámaras. Por consiguiente, se recomienda utilizar en estos casos el método que tradicionalmente se ha empleado para calcular la estabilidad de taludes verticales en suelos cohesivos a corto plazo, en dos dimensiones. Aunque este método puede resultar conservador para paredes de pasta de cámaras secundarias con una relación anchura/altura inferior a 0,5. Para usar relleno de pasta para el sostenimiento en minería subterránea hay que tener en cuenta el cálculo de los parámetros de diseño, optimización de la mezcla, cualidades de bombeo y la operación de transporte al interior de la mina. Los gastos de ésta operación minera son importantes ya que pueden representar hasta de 20%.