117 resultados para Photovoltaic solar energy


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The installers and owners show a growing interest in the follow-up of the performance of their photovoltaic (PV) systems. The owners are requesting reliable sources of information to ensure that their system is functioning properly, and the installers are actively looking for efficient ways of providing them the most useful possible information from the data available. Policy makers are becoming increasingly interested in the knowledge of the real performance of PV systems and the most frequent sources of problems that they suffer to be able to target the identified challenges properly. The scientific and industrial PV community is also requiring an access to massive operational data to pursue the technological improvements further.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The intermediate band solar cell (IBSC), the multiple exciton generation solar cell (MEGSC) and the hot carrier solar cell (HCSC) are three novel concepts in photovoltaics which aim to achieve high efficiency devices. In this paper we assess to what extent their physical principles of operation have been experimentally verified. It is found that there is experimental evidence supporting the underlying theory for all three.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The PVCROPS project (PhotoVolta ic Cost r€duction, Reliability, Operational performance, Prediction and Simulation), cofinanced by European Commission in the frame of Seventh Framework Programme, has compiled in the “Good and bad practices: Manual to improve the quality and reduce the cost of PV systems” a collection of good and bad practices in actual PV plants . All the situations it collects represent the state-of-the-art of existing PV installations all around Europe. They show how the different parts of an installation can be implem ented properly or not. The aim of this manual is to represent a reference text which can help any PV actor (installers, electricians, maintenance operators, owners, etc.) not only to check and improve an already existing installation but will also, and mainly, avoid the previously known bad practices for the construction of a new PV installation. Thus, solving a priori the known errors, new PV installations will be more reliable, efficient and cost-effective and can recover the initial investment in a shorter time. The manual is going to be free available in the PVCROPS website in several languages.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents different test alternatives which can be used on-site in a PV installation to detect potential induced degradation (PID) in modules. The testing procedures proposed are: thermal imaging; electroluminescence imaging; open circuit voltage measurements; operating voltage measurements; IV curve measurements; and dark IV curve measurements. Advantages and disadvantages of each test are reported.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The bankability of CPV projects is an important issue to pave the way toward a swift and sustained growth in this technology. The bankability of a PV plant is generally addressed through the modeling of its energy yield under a b aseline loss scenario, followed by an on-site measurement campaign aimed at verifying its energetic behavior. The main difference between PV and CPV resides in the proper CPV modules, in particular in the inclusion of optical lements and III-V multijunction cells that are much more sensitive to spectral variations than xSi cells, while the rest of the system behaves in a way that possesses many common points with xSi technology. The modeling of the DC power output of a CPV system thus requires several impo rtant second order parameters to be considered, mainly related to optics, spectral direct solar radiation, wind speed, tracker accuracy and heat dissipation of cells.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The hot-spot phenomenon is a relatively frequent problem in current photovoltaic generators. It entails both a risk for the photovoltaic module's lifetime and a decrease in its operational efficiency. Nevertheless, there is still a lack of widely accepted procedures for dealing with them in practice. This paper presents the IES UPM observations on 200 affected modules. Visual and infrared inspection, electroluminescence, peak power and operating voltage tests have been accomplished. Hot-spot observation procedures and well defined acceptance and rejection criteria are proposed, addressing both the lifetime and the operational efficiency of the modules. The operating voltage has come out as the best parameter to control effective efficiency losses for the affected modules. This procedure is oriented to its possible application in contractual frameworks.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Strict technical quality assurance procedures are essential for PV plant bankability. When large-scale PV plants are concerned, this is typically accomplished in three consecutive phases: an energy yield forecast, that is performed at the beginning of the project and is typically accomplished by means of a simulation exercise performed with dedicated software; a reception test campaign, that is performed at the end of the commissioning and consists of a set of tests for determining the efficiency and the reliability of the PV plant devices; and a performance analysis of the first years of operation, that consists in comparing the real energy production with the one calculated from the recorded operating conditions and taking into account the maintenance records. In the last six years, IES-UPM has offered both indoor and on-site quality control campaigns for more than 60 PV plants, with an accumulated power of more than 300 MW, in close contact with Engineering, Procurement and Construction Contractors and financial entities. This paper presents the lessons learned from such experience.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The usage of more inexpensive silicon feedstock for crystallizing mc-Si blocks promises cost reduction for the photovoltaic market. For example, less expensive substrates of upgraded metallurgical silicon (UMG-Si) are used as a mechanical support for the epitaxial solar cell. This feedstock has higher content of impurities which influences cell performance and mechanical strength of the wafers. Thus, it is of importance to know these effects in order to know which impurities should be preferentially removed or prevented during the crystallization process. Metals like aluminum (Al) can decrease the mechanical strength due to micro-cracking of the silicon matrix and introduction of high values of thermal residual stress. Additionally, silicon oxide (SiOx) lowers the mechanical strength of mc-Si due to thermal residual stresses and stress intensification when an external load is applied in the surrounding of the particle. Silicon carbide (SiC) introduces thermal residual stresses and intensifies slightly the stress in the surrounding of the particle but can have a toughening effect on the silicon matrix. Finally, silicon nitride (Si3N4) does not influence significantly the mechanical strength of mc- Si and can have a toughening effect on the silicon matrix.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Grid connected solar plants are a good opportunity for their use for research as a secondary objective. In countries were feed-in tariffs are still active, it is possible to include in the design of the solar plant elements for its use for research. In the case of the solar plant presented here both objectives are covered. The solar plant of this work is formed by PV modules of three different technologies: Multicrystalline, amorphous and CdTe. In one part of the solar plant, the three technologies are working at the same conditions, not only ambient conditions but also similar voltage and current input to the inverters. Both the commercial and the experimental parts of the solar plant have their own independent inverters with their meters but are finally connected to the same meter to inject. In this work we analyse the results for the first year of operation of the experimental solar plant. Productions of three different technologies in exactly the same conditions are compared and presented. According to the results, all the three technologies have conversion efficiencies dropping when the temperature increases. Amorphous module experiences the lesser reduction, whereas the multicrystalline module suffers the most.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A complete characterisation of PV modules for building integration is needed in order to know their influence on the building’s global energy balance. Specifically, certain characteristic parameters should be obtained for each different PV module suitable for building integrated photovoltaics (BIPV), some by direct or indirect measurements at the laboratory, and others by monitoring the element performance mounted in real operating conditions. In the case of transparent building envelopes it is particularly important to perform an optical and thermal characterization of the PV modules that would be integrated in them. This paper addresses the optical characterization of some commercial thin-film PV modules having different degrees of transparency, suitable for building integration in façades. The approach is based on the measurement of the spectral UV/Vis/NIR reflectance and transmittance of the different considered samples, both at normal incidence and as a function of the angle of incidence. With the obtained results, the total and zoned UV, visible and NIR transmission and reflection values are calculated, enabling the correct characterization of the PV modules integrated in façades and the subsequent evaluation of their impact over the electrical, thermal and lighting performance in a building.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Within the European funded project SOPHIA, a Round Robin measurement on CPV module has been initiated. Seven different test laboratories located in Europe between 48°N and 37°N perform measurements of four SOITEC CPV modules. The modules are electrically characterized with different measurement equipment under various climatic conditions. One pyrheliometer and one spectral sensor based on component cells are shipped together with the modules. This ensures that the irradiance and spectrum, two factors with high impact on CPV module performance, are measured with the identical equipment at each site. The round robin activity is performed in closeco-operation with the IEC TC82 WG7 power rating team in order to support the work on the CPV module power rating draft standard 62670-3. The resultingrated module power outputs at CSOC (Concentrator Standard Operating Conditions) are compared amongst the power rating methods and amongst the test labs. In this manner, a deviation in rated power output between different test labs and power rating methods is determined.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Actual system performance of a PV system can differ from its expected behaviour.. This is the main reason why the performance of PV systems should be monitored, analyzed and, if needed, improved on. Some of the current testing procedures relating to the electrical behaviour of PV systems are appropriated for detecting electrical performance losses, but they are not well-suited to reveal hidden defects in the modules of PV plants and BIPV, which can lead to future losses. This paper reports on the tests and procedures used to evaluate the performance of PV systems, and especially on a novel procedure for quick on-site measurements and defect recognition caused by overheating in PV modules located in operating PV installations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Shading reduces the power output of a photovoltaic (PV) system. The design engineering of PV systems requires modeling and evaluating shading losses. Some PV systems are affected by complex shading scenes whose resulting PV energy losses are very difficult to evaluate with current modeling tools. Several specialized PV design and simulation software include the possibility to evaluate shading losses. They generally possess a Graphical User Interface (GUI) through which the user can draw a 3D shading scene, and then evaluate its corresponding PV energy losses. The complexity of the objects that these tools can handle is relatively limited. We have created a software solution, 3DPV, which allows evaluating the energy losses induced by complex 3D scenes on PV generators. The 3D objects can be imported from specialized 3D modeling software or from a 3D object library. The shadows cast by this 3D scene on the PV generator are then directly evaluated from the Graphics Processing Unit (GPU). Thanks to the recent development of GPUs for the video game industry, the shadows can be evaluated with a very high spatial resolution that reaches well beyond the PV cell level, in very short calculation times. A PV simulation model then translates the geometrical shading into PV energy output losses. 3DPV has been implemented using WebGL, which allows it to run directly from a Web browser, without requiring any local installation from the user. This also allows taken full benefits from the information already available from Internet, such as the 3D object libraries. This contribution describes, step by step, the method that allows 3DPV to evaluate the PV energy losses caused by complex shading. We then illustrate the results of this methodology to several application cases that are encountered in the world of PV systems design. Keywords: 3D, modeling, simulation, GPU, shading, losses, shadow mapping, solar, photovoltaic, PV, WebGL

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Con 1.300 millones de personas en el mundo sin acceso a la electricidad (la mayoría en entornos rurales de países empobrecidos), la energía solar fotovoltaica constituye una solución viable técnica y económicamente para electrificar las zonas más remotas del planeta donde las redes eléctricas convencionales no llegan. Casi todos los países en el mundo han desarrollado algún tipo de programa de electrificación fotovoltaica rural durante los últimos 40 años, principalmente los países más pobres, donde a través de diferentes modelos de financiación, se han instalado millones de sistemas solares domiciliarios (pequeños sistemas fotovoltaicos para uso doméstico). Durante este largo período, se han ido superando muchas barreras, como la mejora de la calidad de los sistemas fotovoltaicos, la reducción de costes, la optimización del diseño y del dimensionado de los sistemas, la disponibilidad financiera para implantar programas de electrificación rural, etc. Gracias a esto, la electrificación rural descentralizada ha experimentado recientemente un salto de escala caracterizada por la implantación de grandes programas con miles de sistemas solares domiciliarios e integrando largos períodos de mantenimiento. Muchos de estos grandes programas se están llevando a cabo con limitado éxito, ya que generalmente parten de supuestos e hipótesis poco contrastadas con la realidad, comprometiendo así un retorno económico que permita el desarrollo de esta actividad a largo plazo. En este escenario surge un nuevo reto: el de cómo garantizar la sostenibilidad de los grandes programas de electrificación rural fotovoltaica. Se argumenta que la principal causa de esta falta de rentabilidad es el imprevisto alto coste de la fase de operación y mantenimiento. Cuestiones clave tales como la estructura de costes de operación y mantenimiento o la fiabilidad de los componentes del sistema fotovoltaico no están bien caracterizados hoy en día. Esta situación limita la capacidad de diseñar estructuras de mantenimiento capaces de asegurar la sostenibilidad y la rentabilidad del servicio de operación y mantenimiento en estos programas. Esta tesis doctoral tiene como objetivo responder a estas cuestiones. Se ha realizado varios estudios sobre la base de un gran programa de electrificación rural fotovoltaica real llevado a cabo en Marruecos con más de 13.000 sistemas solares domiciliarios instalados. Sobre la base de este programa se ha hecho una evaluación en profundidad de la fiabilidad de los sistemas solares a partir de los datos de mantenimiento recogidos durante 5 años con más de 80.000 inputs. Los resultados han permitido establecer las funciones de fiabilidad de los equipos tal y como se comportan en condiciones reales de operación, las tasas de fallos y los tiempos medios hasta el fallo para los principales componentes del sistema, siendo este el primer caso de divulgación de resultados de este tipo en el campo de la electrificación rural fotovoltaica. Los dos principales componentes del sistema solar domiciliario, la batería y el módulo fotovoltaico, han sido analizados en campo a través de una muestra de 41 sistemas trabajando en condiciones reales pertenecientes al programa solar marroquí. Por un lado se ha estudiado la degradación de la capacidad de las baterías y por otro la degradación de potencia de los módulos fotovoltaicos. En el caso de las baterías, los resultados nos han permitido caracterizar la curva de degradación en capacidad llegando a obtener una propuesta de nueva definición del umbral de vida útil de las baterías en electrificación rural. También sobre la base del programa solar de Marruecos se ha llevado a cabo un estudio de caracterización de los costes reales de operación y mantenimiento a partir de la base de datos de contabilidad del programa registrados durante 5 años. Los resultados del estudio han permitido definir cuáles son costes que más incidencia tienen en el coste global. Se han obtenido los costes unitarios por sistema instalado y se han calculado los montantes de las cuotas de mantenimiento de los usuarios para garantizar la rentabilidad de la operación y mantenimiento. Finalmente, se propone un modelo de optimización matemática para diseñar estructuras de mantenimiento basado en los resultados de los estudios anteriores. La herramienta, elaborada mediante programación lineal entera mixta, se ha aplicado al programa marroquí con el fin de validar el modelo propuesto. ABSTRACT With 1,300 million people worldwide deprived of access to electricity (mostly in rural environments), photovoltaic solar energy has proven to be a cost‐effective solution and the only hope for electrifying the most remote inhabitants of the planet, where conventional electric grids do not reach because they are unaffordable. Almost all countries in the world have had some kind of rural photovoltaic electrification programme during the past 40 years, mainly the poorer countries, where through different organizational models, millions of solar home systems (small photovoltaic systems for domestic use) have been installed. During this long period, many barriers have been overcome, such as quality enhancement, cost reduction, the optimization of designing and sizing, financial availability, etc. Thanks to this, decentralized rural electrification has recently experienced a change of scale characterized by new programmes with thousands of solar home systems and long maintenance periods. Many of these large programmes are being developed with limited success, as they have generally been based on assumptions that do not correspond to reality, compromising the economic return that allows long term activity. In this scenario a new challenge emerges, which approaches the sustainability of large programmes. It is argued that the main cause of unprofitability is the unexpected high cost of the operation and maintenance of the solar systems. In fact, the lack of a paradigm in decentralized rural services has led to many private companies to carry out decentralized electrification programmes blindly. Issues such as the operation and maintenance cost structure or the reliability of the solar home system components have still not been characterized. This situation does not allow optimized maintenance structure to be designed to assure the sustainability and profitability of the operation and maintenance service. This PhD thesis aims to respond to these needs. Several studies have been carried out based on a real and large photovoltaic rural electrification programme carried out in Morocco with more than 13,000 solar home systems. An in‐depth reliability assessment has been made from a 5‐year maintenance database with more than 80,000 maintenance inputs. The results have allowed us to establish the real reliability functions, the failure rate and the main time to failure of the main components of the system, reporting these findings for the first time in the field of rural electrification. Both in‐field experiments on the capacity degradation of batteries and power degradation of photovoltaic modules have been carried out. During the experiments both samples of batteries and modules were operating under real conditions integrated into the solar home systems of the Moroccan programme. In the case of the batteries, the results have enabled us to obtain a proposal of definition of death of batteries in rural electrification. A cost assessment of the Moroccan experience based on a 5‐year accounting database has been carried out to characterize the cost structure of the programme. The results have allowed the major costs of the photovoltaic electrification to be defined. The overall cost ratio per installed system has been calculated together with the necessary fees that users would have to pay to make the operation and maintenance affordable. Finally, a mathematical optimization model has been proposed to design maintenance structures based on the previous study results. The tool has been applied to the Moroccan programme with the aim of validating the model.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The main objective of this work is to adapt the Laser Induced Forward Techniques (LIFT), a well- known laser direct writing technique for material transfer, to define metallic contacts (fingers and busbars) onto c-Si cells. The silver paste (with viscosity around 30-50 kcPs) is applied over a glass substrate using a coater. The thickness of the paste can be control changing the deposit parameters. The glass with the silver paste is set at a controlled gap over the c-Si cell. A solid state pulsed laser (532 nm) is focused at the glass/silver interface producing a droplet of silver that it is transferred to the c-Si cell. A scanner is used to print lines. The process parameters (silver paste thickness, gap and laser parameters -spot size, pulse energy and overlapping of pulses) are modified and the morphology of the lines is studied using confocal microscopy. Long lines are printed and the uniformity (in thickness and height) is studied. Some examples of metallization of larger areas (up to 10 cm x 10 cm) are presented.