53 resultados para DETECTORS
Resumo:
We report on the fabrication details of TES based on Mo/Au bilayers. The Mo layer is deposited by radio frequency (RF) sputtering and capped with a sputter deposited thin Au protection layer. Afterwards, a second Au layer of suitable (lower) resistivity is deposited ex‐situ by e‐beam evaporation, until completion of the total desired Au thickness. The deposition was performed at room temperature (RT) on LPCVD Si3 N4 membranes. Such a deposition procedure is very reproducible and allow controlling the critical temperature (Tc) and normal electrical resistance (RN ) of the Mo/Au bilayer. The process is optimized to achieve low stress bilayers, thus avoiding the undesirable curvature of the membranes. Bilayers are patterned using photolithographic techniques and wet etching procedures. Mo superconducting paths are used to contact the Mo/Au bilayers, thus ensuring good electrical conductivity and thermal isolation. The entire fabrication process let to stable and reproducible sensors with required and tunable functional properties
Resumo:
Lately the short-wave infrared (SWIR) has become very important due to the recent appearance on the market of the small detectors with a large focal plane array. Military applications for SWIR cameras include handheld and airborne systems with long range detection requirements, but where volume and weight restrictions must be considered. In this paper we present three different designs of telephoto objectives that have been designed according to three different methods. Firstly the conventional method where the starting point of the design is an existing design. Secondly we will face design starting from the design of an aplanatic system. And finally the simultaneous multiple surfaces (SMS) method, where the starting point is the input wavefronts that we choose. The designs are compared in terms of optical performance, volume, weight and manufacturability. Because the objectives have been designed for the SWIR waveband, the color correction has important implications in the choice of glass that will be discussed in detail
Resumo:
A fully 3D iterative image reconstruction algorithm has been developed for high-resolution PET cameras composed of pixelated scintillator crystal arrays and rotating planar detectors, based on the ordered subsets approach. The associated system matrix is precalculated with Monte Carlo methods that incorporate physical effects not included in analytical models, such as positron range effects and interaction of the incident gammas with the scintillator material. Custom Monte Carlo methodologies have been developed and optimized for modelling of system matrices for fast iterative image reconstruction adapted to specific scanner geometries, without redundant calculations. According to the methodology proposed here, only one-eighth of the voxels within two central transaxial slices need to be modelled in detail. The rest of the system matrix elements can be obtained with the aid of axial symmetries and redundancies, as well as in-plane symmetries within transaxial slices. Sparse matrix techniques for the non-zero system matrix elements are employed, allowing for fast execution of the image reconstruction process. This 3D image reconstruction scheme has been compared in terms of image quality to a 2D fast implementation of the OSEM algorithm combined with Fourier rebinning approaches. This work confirms the superiority of fully 3D OSEM in terms of spatial resolution, contrast recovery and noise reduction as compared to conventional 2D approaches based on rebinning schemes. At the same time it demonstrates that fully 3D methodologies can be efficiently applied to the image reconstruction problem for high-resolution rotational PET cameras by applying accurate pre-calculated system models and taking advantage of the system's symmetries.
Resumo:
The use of ion microbeams as probes for computedtomography has proven to be a powerful tool for the three-dimensional characterization of specimens a few tens of micrometers in size. Compared to other types of probes, the main advantage is that quantitative information about mass density and composition can be obtained directly, using specific reconstruction codes. At the Centre d’Etudes Nucléaires de Bordeaux Gradignan (CENBG), this technique was initially developed for applications in cellular biology. However, the observation of the cell ultrastructure requires a sub-micron resolution. The construction of the nanobeamline at the Applications Interdisciplinaires des Faisceaux d’Ions en Region Aquitaine (AIFIRA) irradiation facility has opened new perspectives for such applications. The implementation of computedtomography on the nanobeamline of CENBG has required a careful design of the analysis chamber, especially microscopes for precise sample visualization, and detectors for scanning transmission ion microscopy (STIM) and for particle induced X-ray emission (PIXE). The sample can be precisely positioned in the three directions X, Y, Z and a stepper motor coupled to a goniometer ensures the rotational motion. First images of 3D tomography were obtained on a reference sample containing microspheres of certified diameter, showing the good stability of the beam and the sample stage, and the precision of the motion.
Resumo:
A high resolution focused beam line has been recently installed on the AIFIRA (“Applications Interdisciplinaires des Faisceaux d’Ions en Région Aquitaine”) facility at CENBG. This nanobeam line, based on a doublet–triplet configuration of Oxford Microbeam Ltd. OM-50™ quadrupoles, offers the opportunity to focus protons, deuterons and alpha particles in the MeV energy range to a sub-micrometer beam spot. The beam optics design has been studied in detail and optimized using detailed ray-tracing simulations and the full mechanical design of the beam line was reported in the Debrecen ICNMTA conference in 2008. During the last two years, the lenses have been carefully aligned and the target chamber has been fully equipped with particle and X-ray detectors, microscopes and precise positioning stages. The beam line is now operational and has been used for its firstapplications to ion beam analysis. Interestingly, this set-up turned out to be a very versatile tool for a wide range of applications. Indeed, even if it was not intended during the design phase, the ion optics configuration offers the opportunity to work either with a high current microbeam (using the triplet only) or with a lower current beam presenting a sub-micrometer resolution (using the doublet–triplet configuration). The performances of the CENBGnanobeam line are presented for both configurations. Quantitative data concerning the beam lateral resolutions at different beam currents are provided. Finally, the firstresults obtained for different types of application are shown, including nuclear reaction analysis at the micrometer scale and the firstresults on biological samples
Resumo:
Esta tesis analiza los elementos que afectan a la evaluación del rendimiento dentro de la técnica de radiodiagnóstico mediante tomografía por emisión de positrones (PET), centrándose en escáneres preclínicos. Se exploran las posibilidades de los protocolos estándar de evaluación sobre los siguientes aspectos: su uso como herramienta para validar programas de simulación Montecarlo, como método para la comparación de escáneres y su validez en el estudio del efecto sobre la calidad de imagen al utilizar radioisótopos alternativos. Inicialmente se estudian los métodos de evaluación orientados a la validación de simulaciones PET, para ello se presenta el programa GAMOS como entorno de simulación y se muestran los resultados de su validación basada en el estándar NEMA NU 4-2008 para escáneres preclínicos. Esta validación se ha realizado mediante la comparación de los resultados simulados frente a adquisiciones reales en el equipo ClearPET, describiendo la metodología de evaluación y selección de los parámetros NEMA. En este apartado también se mencionan las aportaciones desarrolladas en GAMOS para aplicaciones PET, como la inclusión de herramientas para la reconstrucción de imágenes. Por otro lado, la evaluación NEMA del ClearPET es utilizada para comparar su rendimiento frente a otro escáner preclínico: el sistema rPET-1. Esto supone la primera caracterización NEMA NU 4 completa de ambos equipos; al mismo tiempo que se analiza cómo afectan las importantes diferencias de diseño entre ellos, especialmente el tamaño axial del campo de visión y la configuración de los detectores. El 68Ga es uno de los radioisótopos no convencionales en imagen PET que está experimentando un mayor desarrollo, sin embargo, presenta la desventaja del amplio rango o distancia recorrida por el positrón emitido. Además del rango del positrón, otra propiedad física característica de los radioisótopos PET que puede afectar a la imagen es la emisión de fotones gamma adicionales, tal como le ocurre al isótopo 48V. En esta tesis se evalúan dichos efectos mediante estudios de resolución espacial y calidad de imagen NEMA. Finalmente, se analiza el alcance del protocolo NEMA NU 4-2008 cuando se utiliza para este propósito, adaptándolo a tal fin y proponiendo posibles modificaciones. Abstract This thesis analyzes the factors affecting the performance evaluation in positron emission tomography (PET) imaging, focusing on preclinical scanners. It explores the possibilities of standard protocols of assessment on the following aspects: their use as tools to validate Monte Carlo simulation programs, their usefulness as a method for comparing scanners and their validity in the study of the effect of alternative radioisotopes on image quality. Initially we study the methods of performance evaluation oriented to validate PET simulations. For this we present the GAMOS program as a simulation framework and show the results of its validation based on the standard NEMA NU 4-2008 for preclinical PET scanners. This has been accomplished by comparing simulated results against experimental acquisitions in the ClearPET scanner, describing the methodology for the evaluation and selection of NEMA parameters. This section also mentions the contributions developed in GAMOS for PET applications, such as the inclusion of tools for image reconstruction. Furthermore, the evaluation of the ClearPET scanner is used to compare its performance against another preclinical scanner, specifically the rPET-1 system. This is the first complete NEMA NU 4 based characterization study of both systems. At the same time we analyze how do the significant design differences of these two systems, especially the size of the axial field of view and the detectors configuration affect their performance characteristics. 68Ga is one of the unconventional radioisotopes in PET imaging the use of which is currently significantly increasing; however, it presents the disadvantage of the long positron range (distance traveled by the emitted positron before annihilating with an electron). Besides the positron range, additional gamma photon emission is another physical property characteristic of PET radioisotopes that can affect the reconstructed image quality, as it happens to the isotope 48V. In this thesis we assess these effects through studies of spatial resolution and image quality. Finally, we analyze the scope of the NEMA NU 4-2008 to carry out such studies, adapting it and proposing possible modifications.
Resumo:
In the course of discussing different target types for their suitability in the European Spallation Source (ESS) one main focus was on neutronics' performance. Diverse concepts have been assessed baselining some preliminary engineering and geometrical details and including some optimization. With the restrictions and resulting uncertainty imposed by the lack of detailed designs optimizations at the time of compiling this paper, the conclusion drawn is basically that there is a little difference in the neutronic yield of the investigated targets. Other criteria like safety, environmental compatibility, reliability and cost will thus dominate the choice of an ESS target.
Resumo:
The development of new-generation intelligent vehicle technologies will lead to a better level of road safety and CO2 emission reductions. However, the weak point of all these systems is their need for comprehensive and reliable data. For traffic data acquisition, two sources are currently available: 1) infrastructure sensors and 2) floating vehicles. The former consists of a set of fixed point detectors installed in the roads, and the latter consists of the use of mobile probe vehicles as mobile sensors. However, both systems still have some deficiencies. The infrastructure sensors retrieve information fromstatic points of the road, which are spaced, in some cases, kilometers apart. This means that the picture of the actual traffic situation is not a real one. This deficiency is corrected by floating cars, which retrieve dynamic information on the traffic situation. Unfortunately, the number of floating data vehicles currently available is too small and insufficient to give a complete picture of the road traffic. In this paper, we present a floating car data (FCD) augmentation system that combines information fromfloating data vehicles and infrastructure sensors, and that, by using neural networks, is capable of incrementing the amount of FCD with virtual information. This system has been implemented and tested on actual roads, and the results show little difference between the data supplied by the floating vehicles and the virtual vehicles.
Resumo:
We are investigating the performances of a data acquisition system for Time of Flight PET, based on LYSO crystal slabs and 64 channels Silicon Photomultipliers matrices (1.2 cm2 of active area each). Measurements have been performed to test the timing capability of the detection system (SiPM matices coupled to a LYSO slab and the read-out electronics) with both test signal and radioactive source.
Resumo:
In this paper, the authors provide a methodology to design nonparametric permutation tests and, in particular, nonparametric rank tests for applications in detection. In the first part of the paper, the authors develop the optimization theory of both permutation and rank tests in the Neyman?Pearson sense; in the second part of the paper, they carry out a comparative performance analysis of the permutation and rank tests (detectors) against the parametric ones in radar applications. First, a brief review of some contributions on nonparametric tests is realized. Then, the optimum permutation and rank tests are derived. Finally, a performance analysis is realized by Monte-Carlo simulations for the corresponding detectors, and the results are shown in curves of detection probability versus signal-to-noise ratio
Resumo:
Outline: • Motivation, aim • Complement waveguide data on silica • Optical data in quartz • Detailed analysis, i.e. both fluence kinetics and resolution • Efficiency of irradiation and analysis, samples, time... • Experimental set-up description • Reflectance procedure • Options: light source (lasers, white light..), detectors, configurations • Results and discussion • Comparative of amorphous and crystalline phases
Resumo:
En este proyecto se van a aplicar las técnicas de análisis de ruido para caracterizar la respuesta dinámica de varios sensores de temperatura, tanto termorresistencias de platino como de termopares. Estos sensores son imprescindibles para él correcto funcionamiento de las centrales nucleares y requieren vigilancia para garantizar la exactitud de las medidas. Las técnicas de análisis de ruido son técnicas pasivas, es decir, no afectan a la operación de la planta y permiten realizar una vigilancia in situ de los sensores. Para el caso de los sensores de temperatura, dado que se pueden asimilar a sistemas de primer orden, el parámetro fundamental a vigilar es el tiempo de respuesta. Éste puede obtenerse para cada una de las sondas por medio de técnicas en el dominio de la frecuencia (análisis espectral) o por medio de técnicas en el dominio del tiempo (modelos autorregresivos). Además de la estimación del tiempo de respuesta, se realizará una caracterización estadística de las sondas. El objetivo es conocer el comportamiento de los sensores y vigilarlos de manera que se puedan diagnosticar las averías aunque éstas estén en una etapa incipiente. ABSTRACT In this project we use noise analysis technique to study the dynamic response of RTDs (Resistant temperature detectors) and thermocouples. These sensors are essential for the proper functioning of nuclear power plants and therefore need to be monitored to guarantee accurate measurements. The noise analysis techniques do not affect plant operation and allow in situ monitoring of the sensors. Temperature sensors are equivalent to first order systems. In these systems the main parameter to monitor is the response time which can be obtained by means of techniques in the frequency domain (spectral analysis) as well as time domain (autoregressive models). Besides response time estimation the project will also include a statistical study of the probes. The goal is to understand the behavior of the sensors and monitor them in order to detect any anomalies or malfunctions even if they occur in an early stage.
Resumo:
It is a known fact that noise analysis is a suitable method for sensor performance surveillance. In particular, controlling the response time of a sensor is an efficient way to anticipate failures and to have the opportunity to prevent them. In this work the response times of several sensors of Trillo NPP are estimated by means of noise analysis. The procedure applied consists of modeling each sensor with autoregressive methods and getting the searched parameter by analyzing the response of the model when a ramp is simulated as the input signal. Core exit thermocouples and in core self-powered neutron detectors are the main sensors analyzed but other plant sensors are studied as well. Since several measurement campaigns have been carried out, it has been also possible to analyze the evolution of the estimated parameters during more than one fuel cycle. Some sensitivity studies for the sample frequency of the signals and its influence on the response time are also included. Calculations and analysis have been done in the frame of a collaboration agreement between Trillo NPP operator (CNAT) and the School of Mines of Madrid.
Resumo:
La diabetes mellitus es el conjunto de alteraciones provocadas por un defecto en la cantidad de insulina secretada o por un aprovechamiento deficiente de la misma. Es causa directa de complicaciones a corto, medio y largo plazo que disminuyen la calidad y las expectativas de vida de las personas con diabetes. La diabetes mellitus es en la actualidad uno de los problemas más importantes de salud. Ha triplicado su prevalencia en los últimos 20 anos y para el año 2025 se espera que existan casi 300 millones de personas con diabetes. Este aumento de la prevalencia junto con la morbi-mortalidad asociada a sus complicaciones micro y macro-vasculares convierten la diabetes en una carga para los sistemas sanitarios, sus recursos económicos y sus profesionales, haciendo de la enfermedad un problema individual y de salud pública de enormes proporciones. De momento no existe cura a esta enfermedad, de modo que el objetivo terapéutico del tratamiento de la diabetes se centra en la normalización de la glucemia intentando minimizar los eventos de hiper e hipoglucemia y evitando la aparición o al menos retrasando la evolución de las complicaciones vasculares, que constituyen la principal causa de morbi-mortalidad de las personas con diabetes. Un adecuado control diabetológico implica un tratamiento individualizado que considere multitud de factores para cada paciente (edad, actividad física, hábitos alimentarios, presencia de complicaciones asociadas o no a la diabetes, factores culturales, etc.). Sin embargo, a corto plazo, las dos variables más influyentes que el paciente ha de manejar para intervenir sobre su nivel glucémico son la insulina administrada y la dieta. Ambas presentan un retardo entre el momento de su aplicación y el comienzo de su acción, asociado a la absorción de los mismos. Por este motivo la capacidad de predecir la evolución del perfil glucémico en un futuro cercano, ayudara al paciente a tomar las decisiones adecuadas para mantener un buen control de su enfermedad y evitar situaciones de riesgo. Este es el objetivo de la predicción en diabetes: adelantar la evolución del perfil glucémico en un futuro cercano para ayudar al paciente a adaptar su estilo de vida y sus acciones correctoras, con el propósito de que sus niveles de glucemia se aproximen a los de una persona sana, evitando así los síntomas y complicaciones de un mal control. La aparición reciente de los sistemas de monitorización continua de glucosa ha proporcionado nuevas alternativas. La disponibilidad de un registro exhaustivo de las variaciones del perfil glucémico, con un periodo de muestreo de entre uno y cinco minutos, ha favorecido el planteamiento de nuevos modelos que tratan de predecir la glucemia utilizando tan solo las medidas anteriores de glucemia o al menos reduciendo significativamente la información de entrada a los algoritmos. El hecho de requerir menor intervención por parte del paciente, abre nuevas posibilidades de aplicación de los predictores de glucemia, haciéndose viable su uso en tiempo real, como sistemas de ayuda a la decisión, como detectores de situaciones de riesgo o integrados en algoritmos automáticos de control. En esta tesis doctoral se proponen diferentes algoritmos de predicción de glucemia para pacientes con diabetes, basados en la información registrada por un sistema de monitorización continua de glucosa así como incorporando la información de la insulina administrada y la ingesta de carbohidratos. Los algoritmos propuestos han sido evaluados en simulación y utilizando datos de pacientes registrados en diferentes estudios clínicos. Para ello se ha desarrollado una amplia metodología, que trata de caracterizar las prestaciones de los modelos de predicción desde todos los puntos de vista: precisión, retardo, ruido y capacidad de detección de situaciones de riesgo. Se han desarrollado las herramientas de simulación necesarias y se han analizado y preparado las bases de datos de pacientes. También se ha probado uno de los algoritmos propuestos para comprobar la validez de la predicción en tiempo real en un escenario clínico. Se han desarrollado las herramientas que han permitido llevar a cabo el protocolo experimental definido, en el que el paciente consulta la predicción bajo demanda y tiene el control sobre las variables metabólicas. Este experimento ha permitido valorar el impacto sobre el control glucémico del uso de la predicción de glucosa. ABSTRACT Diabetes mellitus is the set of alterations caused by a defect in the amount of secreted insulin or a suboptimal use of insulin. It causes complications in the short, medium and long term that affect the quality of life and reduce the life expectancy of people with diabetes. Diabetes mellitus is currently one of the most important health problems. Prevalence has tripled in the past 20 years and estimations point out that it will affect almost 300 million people by 2025. Due to this increased prevalence, as well as to morbidity and mortality associated with micro- and macrovascular complications, diabetes has become a burden on health systems, their financial resources and their professionals, thus making the disease a major individual and a public health problem. There is currently no cure for this disease, so that the therapeutic goal of diabetes treatment focuses on normalizing blood glucose events. The aim is to minimize hyper- and hypoglycemia and to avoid, or at least to delay, the appearance and development of vascular complications, which are the main cause of morbidity and mortality among people with diabetes. A suitable, individualized and controlled treatment for diabetes involves many factors that need to be considered for each patient: age, physical activity, eating habits, presence of complications related or unrelated to diabetes, cultural factors, etc. However, in the short term, the two most influential variables that the patient has available in order to manage his/her glycemic levels are administered insulin doses and diet. Both suffer from a delay between their time of application and the onset of the action associated with their absorption. Therefore, the ability to predict the evolution of the glycemic profile in the near future could help the patient to make appropriate decisions on how to maintain good control of his/her disease and to avoid risky situations. Hence, the main goal of glucose prediction in diabetes consists of advancing the evolution of glycemic profiles in the near future. This would assist the patient in adapting his/her lifestyle and in taking corrective actions in a way that blood glucose levels approach those of a healthy person, consequently avoiding the symptoms and complications of a poor glucose control. The recent emergence of continuous glucose monitoring systems has provided new alternatives in this field. The availability of continuous records of changes in glycemic profiles (with a sampling period of one or five minutes) has enabled the design of new models which seek to predict blood glucose by using automatically read glucose measurements only (or at least, reducing significantly the data input manually to the algorithms). By requiring less intervention by the patient, new possibilities are open for the application of glucose predictors, making its use feasible in real-time applications, such as: decision support systems, hypo- and hyperglycemia detectors, integration into automated control algorithms, etc. In this thesis, different glucose prediction algorithms are proposed for patients with diabetes. These are based on information recorded by a continuous glucose monitoring system and incorporate information of the administered insulin and carbohydrate intakes. The proposed algorithms have been evaluated in-silico and using patients’ data recorded in different clinical trials. A complete methodology has been developed to characterize the performance of predictive models from all points of view: accuracy, delay, noise and ability to detect hypo- and hyperglycemia. In addition, simulation tools and patient databases have been deployed. One of the proposed algorithms has additionally been evaluated in terms of real-time prediction performance in a clinical scenario in which the patient checked his/her glucose predictions on demand and he/she had control on his/her metabolic variables. This has allowed assessing the impact of using glucose prediction on glycemic control. The tools to carry out the defined experimental protocols were also developed in this thesis.
Resumo:
This paper reports on design studies concerning a moderator concept which aims to maximize the time averaged flux. The idea is to provide neutron spectra showing two clear maxima, with peaks at View the MathML source and View the MathML source arising from leakage from both cryogenic and thermal moderators. Such a concept known as a bi-spectral moderator (Mezei, 2006 [1]) while proven on a reactor source has only been examined for the ESS 2003 proposal. Filges et al. (2003 [2]), which featured a different design than the current ESS. This paper thus reports on a baseline design for such a moderator concept and shows that it can provide substantial gains in count rates for those applications not requiring high resolution in time-of-flight.