27 resultados para DESTRUCTIVE INTERFERENCE
Resumo:
In recent years, the technology for measuring the diameter and height of standing trees has improved significantly. These enhancements allow estimation of the volume of standing trees using stem taper equations, which traditionally have been constructed with data from felled trees, in an accurate and economically feasible way. A nondestructive method was evaluated with data from 38 pines and was validated with data from another 38 pines, both in the Northern Iberian Range (Spain). The electronic dendrometer Criterion RD1000 (Laser Technology Inc.) and the laser hypsometer TruPulse (Laser Technology Inc.) were used due to their accuracy and interoperability. The methodology was valid (unbiased and precise) measuring from a distance similar to the height of the tree. In this distance, statistical criteria and plots based on the residuals showed no clear advantage in volume estimation with models fitted with data from destructive methods against models fitted with data from the proposed non-destructive technique. This methodology can be considered useful for individual volume estimation and for developing taper equations.
Resumo:
This work compared the quantification of soluble fibre in feeds using different chemical and in vitro approaches, and studied the potential interference between soluble fibre and mucin determinations. Six ingredients: sugar beet pulp (SBP), SBP pectins, insoluble SBP, wheat straw, sunflower hulls and lignocellulose, and seven rabbit diets, differing in soluble fibre content, were evaluated. In experiment 1, ingredients and diets were analyzed for total dietary fibre (TDF), insoluble dietary fibre (IDF), soluble dietary fibre (SDF), aNDFom (corrected for protein, aNDFom-cp) and 2-step pepsin/pancreatin in vitro DM indigestibility (corrected for ash and protein, ivDMi2). Soluble fibre was estimated by difference using three procedures: TDF?IDF (SDFIDF), TDF?ivDMi2 (SDFivDMi2), and TDF?aNDFom-cp (SDFaNDFom-cp). Soluble fibre determined directly (SDF) or by difference as SDFivDMi2 were not different (109 g/kg DM, on average). However, when it was calculated as SDFaNDFom-cp the value was 40% higher (153 g/kg DM, P menor que 0.05), whereas SDFIDF (124 g/kg DM) did not differ from any of the other methods. The correlation between the four methods was high (r ? 0.96; P ? 0.001; n = 13), but it decreased or even disappeared when SBP pectins and SBP were excluded and a lower and more narrow range of variation of soluble fibre was used. In experiment 2, the ivDMi2 using crucibles (reference method) were compared to those made using individual or collective ankom bags in order to simplify the determination of SDFivDMi2. The ivDMi2 was not different when using crucibles or individual or collective ankom bags. In experiment 3, the potential interference between soluble fibre and intestinal mucin determinations was studied using rabbit intestinal raw mucus, digesta and SBP pectins, lignocelluloses and a rabbit diet. An interference was observed between the determinations of soluble fibre and crude mucin, as contents of TDF and apparent crude mucin were high in SBP pectins (994 and 709 g/kg DM) and rabbit intestinal raw mucus (571 and 739 g/kg DM). After a pectinase treatment, the coefficient of apparent mucin recovery of SBP pectins was close to zero, whereas that of rabbit mucus was not modified. An estimation of the crude mucin carbohydrates retained in digesta TDF is proposed to correct TDF and soluble fibre digestibility. In conclusion, the values of soluble fibre depend on the methodology used. The contamination of crude mucin with soluble fibre is avoided using pectinase.
Resumo:
Assessment of laser peening induced effects on Ti6Al4V by destructive and non-destructive techniques
Resumo:
NMR can be considered a multi-scale multidimensional technology in the sense that it provides both spatial insight at macroscopic (MRI) or microscopic level (relaxometry), together with chemical characterization (HR-MAS). In this study 296 apples (from 4 cultivars) were MRI screened (20 slices per fruit) among which 7 fruits were used for metabolomic study by 1H HR MAS in order to assess various chemical shifts: malic acid, sucrose, glucose, fructose and ethanol. On the first season, tissue samples were taken from the sound and affected apples (near the core, centre and outer part of the mesocarp) belonging to sound and affected locations, while on the second season, tissue samples were focused on the comparison between sound and affected tissue. Beside, MRI and 2D non-destructive relaxometry (on whole fruits, and localized tissue) where performed on 72 and 12 apples respectively in order to compare features at macroscopic (tissue) and microscopic (subcellular) level. HR MAS shows higher content of ?-glucose, ?-glucose, malic acid and aromatic compounds in watercore affected tissues from both seasons, while sound tissue reflects higher sucrose. Microscopic (subcellular) degradation of tissue varies according to disorder development and is in good accordance with macroscopic characterization with MRI.
Resumo:
Apples can be considered as having a complex system formed by several structures at different organization levels: macroscale (mayor que100 ?m) and microscale (menor que100 ?m). This work implements 2D T1/T2 global and localized relaxometry sequences on whole apples to be able to perform an intensive non-destructive and non-invasive microstructure study. The 2D T1/T2 cross-correlation spectroscopy allows the extraction of quantitative information about the water compartmentation in different subcellular organelles. A clear difference is found as sound apples show neat peaks for water in different subcellular compartments, such as vacuolar, cytoplasmatic and extracellular water, while in watercore-affected tissues such compartments appear merged. Localized relaxometry allows for the predefinition of slices in order to understand the microstructure of a particular region of the fruit, providing information that cannot be derived from global 2D T1/T2 relaxometry.
Resumo:
The analysis of the interference modes has an increasing application, especially in the field of optical biosensors. In this type of sensors, the displacement Δν of the interference modes of the transduction signal is observed when a particular biological agent is placed over the biosensor. In order to measure this displacement, the position of a maximum (or a minimum) of the signal must be detected before and after placing the agent over the sensor. A parameter of great importance for this kind of sensors is the period Pν of the signal, which is inversely proportional to the optical thickness h0 of the sensor in the absence of the biological agent. The increase of this period improves the sensitivity of the sensor but it worsens the detection of the maximum. In this paper, authors analyze the propagation of uncertainties in these sensors when using least squares techniques for the detection of the maxima (or minima) of the signal. Techniques described in supplement 2 of the ISO-GUM Guide are used. The result of the analysis allows a metrological educated answer to the question of which is the optimal period Pν of the signal. El análisis del comportamiento de los modos de interferencia tiene una aplicación cada vez más amplia, especialmente en el campo de los biosensores ópticos. En este tipo de sensores se observa el desplazamiento Δν de los modos de interferencia de la señal de transducción al reconocer un de-terminado agente biológico. Para medir ese desplazamiento se debe detectar la posición de un máximo o mínimo de la señal antes y después de dicho desplazamiento. En este tipo de biosensores un parámetro de gran importancia es el periodo Pν de la señal el cual es inversamente proporcional al espesor óptico h0 del sensor en ausencia de agente biológico. El aumento de dicho periodo mejora la sensibilidad del sensor pero parece dificultar la detección del mínimo o máximo. Por tanto, su efecto sobre la incertidumbre del resultado de la medida presenta dos efectos contrapuestos: la mejora de la sensibilidad frente a la dificultad creciente en la detección del mínimo ó máximo. En este trabajo, los autores analizan la propagación de incertidumbres en estos sensores utilizando herramientas de ajuste por MM.CC. para la detección de los mínimos o máximos de la señal y técnicas de propagación de incertidumbres descritas en el suplemento 2 de la Guía ISO-GUM. El resultado del análisis permite dar una respuesta, justificada desde el punto de vista metrológico, de en que condiciones es conveniente o no aumentar el periodo Pν de la señal.
Resumo:
Differential Phase Shift Keying (DPSK) modulation format has been shown as a robust solution for next-generation optical transmission systems. One key device enabling such systems is the delay interferometer, converting the signal phase information into intensity modulation to be detected by the photodiodes. Usually, Mach-Zehnder interferometer (MZI) is used for demodulating DPSK signals. In this paper, we developed an MZI which is based on all-fiber Multimode Interference (MI) structure: a multimode fiber (MMF) located between two single-mode fibers (SMF) without any transition zones. The standard MZI is not very stable since the two beams go through two different paths before they recombine. In our design the two arms of the MZI are in the same fiber, which will make it less temperature-sensitive than the standard MZI. Performance of such MZI will be analyzed from transmission spectrum. Finally such all-fiber MI-based MZI (MI-MZI) is used to demodulate 10 Gbps DPSK signals. The demodulated signals are analyzed from eye diagram and bit error rate (BER).
Resumo:
Las técnicas de speckle tienen un gran interés científico e ingenieril, ya que son métodos de ejecución rápida y no destructiva, con base en el análisis de las fluctuaciones de intensidad de la radiación producida cuando la luz coherente de un haz láser es esparcida por un material dado. En este caso se produce un patrón aleatorio de interferencia y difracción donde la suma de las componentes desfasadas dará lugar a máximos y mínimos de intensidad en distintos puntos del espacio. Éste, pese a tratarse de un ruido nocivo en multitud de áreas tales como la transmisión de señales o la holografía, tiene importantes propiedades físicas que lo caracterizan y lo hacen útil como medio para analizar sistemas reales de muy diversa índole. En el presente estudio, se ha llevado a cabo un análisis polarimétrico de la radiación aleatoria esparcida por una serie de muestras metálicas y dieléctricas con el objetivo de establecer una base comparativa que nos permita poder distinguir unas de otras. Para este fin se han comparado los parámetros de polarización de Stokes, el grado de polarización de la luz, las distribuciones de intensidad y el tamaño medio del speckle registrado en los distintos patrones de intensidad. Además, se analizará la dependencia de la rugosidad en el grado de polarización de la luz para los distintos medios sometidos a estudio. Abstract Speckle techniques have a great scientific and engineering interest as they are methods of rapid and non-destructive execution, based on the analysis of the fluctuations of intensity of the radiation produced when coherent light of a laser beam is scattered by a material given. In this case, a random pattern of interference and diffraction occurs where the sum of phase shifted components will result in maximum or minimum of intensity at different points in space. This, despite being a harmful noise in many areas such as signal transmission or holography, has important physical properties that characterize it and make it useful as a means to analyze real systems of various kinds. In the present study, we have conducted a polarimetric analysis of the random radiation scattered by a series of metal and dielectric samples in order to establish a comparative basis to allow us to distinguish one from another. To this end we have compared, the stokes polarization parameters, the degree of polarization (DOP), the intensity distributions and the average size of the speckle registered in the different intensity patterns. Furthermore, dependence of roughness in the DOP of light for the different means under study will be analyzed.
Resumo:
Los pernos conectores aportan múltiples ventajas de uso, entre las que se encuentra el elevado margen de seguridad que ofrecen sus soldaduras ejecutadas mediante arco eléctrico. Estas soldaduras, aunque ampliamente fiables, son difícilmente comprobadas mediante ensayos no destructivos. Aparte de la inspección visual, que aporta gran información sobre la calidad de ejecución de la soldadura, el resto de ensayos no destructivos (líquidos penetrantes, partículas magnéticas, ultrasonidos, radiografías, etc.) resultan inviables en estos elementos. Por otro lado, los ensayos acústicos de piezas metálicas han existido siempre. Su comprobación se basaba en el análisis por medio de ¿un oído fino¿ del sonido resultante tras ser golpeado el elemento a evaluar. Con estas premisas se plantea el presente estudio de inspección de las soldaduras en pernos conectores mediante su espectro acústico. Analíticamente, la investigación se ha centrado en el cálculo informático de los primeros modos propios de vibración mediante elementos finitos. Se han modelizado diferentes grados de penetración de la soldadura mediante la modificación de las condiciones de contorno. Se ha observado que variando el número de movimientos coaccionados en los nodos pertenecientes a la soldadura se produce una reducción en su frecuencia de vibración.
Resumo:
Apples can be considered as having a complex system formed by several structures at different organization levels: macroscale (>100 μm) and microscale (<100 μm). This work implements 2D T1/T2 global and localized relaxometry sequences on whole apples to be able to perform an intensive non-destructive and non-invasive microstructure study. The 2D T1/T2 cross-correlation spectroscopy allows the extraction of quantitative information about the water compartmentation in different subcellular organelles. A clear difference is found as sound apples show neat peaks for water in different subcellular compartments, such as vacuolar, cytoplasmatic and extracellular water, while in watercore-affected tissues such compartments appear merged. Localized relaxometry allows for the predefinition of slices in order to understand the microstructure of a particular region of the fruit, providing information that cannot be derived from global 2D T1/T2 relaxometry.
Resumo:
Cognitive radio represents a promising paradigm to further increase transmission rates in wireless networks, as well as to facilitate the deployment of self-organized networks such as femtocells. Within this framework, secondary users (SU) may exploit the channel under the premise to maintain the quality of service (QoS) on primary users (PU) above a certain level. To achieve this goal, we present a noncooperative game where SU maximize their transmission rates, and may act as well as relays of the PU in order to hold their perceived QoS above the given threshold. In the paper, we analyze the properties of the game within the theory of variational inequalities, and provide an algorithm that converges to one Nash Equilibrium of the game. Finally, we present some simulations and compare the algorithm with another method that does not consider SU acting as relays.
Resumo:
Mealiness is known as an important internal quality attribute of fruits/vegetables, which has significant influence on consumer purchasing decisions. Mealiness has been a topic of research interest over the past several decades. A number of destructive and nondestructive techniques are introduced for mealiness detection. Nondestructive methods are more interesting because they are rapid, noninvasive, and suitable for real-time purposes. In this review, the concept of mealiness is presented for potato, apple, and peach, followed by an in-depth discussion about applications of destructive and nondestructive techniques developed for mealiness detection. The results suggest the potential of electromagnetic-based techniques for nondestructive mealiness evaluation. Further investigations are in progress to find more appropriate nondestructive techniques as well as cost and performance.