64 resultados para Carrion
Resumo:
The effect of cup anemometer shape parameters, such as the cups’ shape, their size, and their center rotation radius, was experimentally analyzed.This analysis was based on both the calibration constants of the transfer function and the most important harmonic termof the rotor’smovement,which due to the cup anemometer design is the third one.This harmonic analysis represents a new approach to study cup anemometer performances. The results clearly showed a good correlation between the average rotational speed of the anemometer’s rotor and the mentioned third harmonic term of its movement.
Resumo:
Due to the high dependence of photovoltaic energy efficiency on environmental conditions (temperature, irradiation...), it is quite important to perform some analysis focusing on the characteristics of photovoltaic devices in order to optimize energy production, even for small-scale users. The use of equivalent circuits is the preferred option to analyze solar cells/panels performance. However, the aforementioned small-scale users rarely have the equipment or expertise to perform large testing/calculation campaigns, the only information available for them being the manufacturer datasheet. The solution to this problem is the development of new and simple methods to define equivalent circuits able to reproduce the behavior of the panel for any working condition, from a very small amount of information. In the present work a direct and completely explicit method to extract solar cell parameters from the manufacturer datasheet is presented and tested. This method is based on analytical formulation which includes the use of the Lambert W-function to turn the series resistor equation explicit. The presented method is used to analyze commercial solar panel performance (i.e., the current-voltage–I-V–curve) at different levels of irradiation and temperature. The analysis performed is based only on the information included in the manufacturer’s datasheet.
Resumo:
The calibration coefficients of two commercial anemometers equipped with different rotors were studied. The rotor cups had the same conical shape, while the size and distance to the rotation axis varied.The analysis was based on the 2-cup positions analytical model, derived using perturbation methods to include second-order effects such as pressure distribution along the rotating cups and friction.Thecomparison with the experimental data indicates a nonuniformdistribution of aerodynamic forces on the rotating cups, with higher forces closer to the rotating axis. The 2-cup analytical model is proven to be accurate enough to study the effect of complex forces on cup anemometer performance.
Resumo:
High suction loads appear on roofs of low-height buildings. The use of parapets with appropriate height at the roof edges alleviates these loads. The performance of six parapet configurations to decrease the suction loads induced on roofs by oblique winds has been studied in a low speed wind tunnel. The studied parapet configurations include vertical wall parapets, either solid or porous, and cantilevered parapets formed by a small horizontal roof close to the building roof. Low-height parapets with a medium porosity and cantilevered parapets are more efficient than solid parapets to reduce the wind suctions generated on the roofs by conical vortices.
Resumo:
The yawing moment acting on the box-girder deck of reinforced concrete bridges constructed using the balanced cantilever method during the erection stage has been experimentally analyzed by testing different types of bridge cross-sections. Experimental results show that the yawing moment coefficient decreases as the bridge decks become streamlined, and that the yawing moment coefficient reaches a maximum when the bridge deck length is nearly twice the deck width.
Resumo:
Different methods to reduce the high suction caused by conical vortices have been reported in the literature: vertical parapets, either solid or porous, placed at the roof edges being the most analysed configuration. Another method for alleviating the high suction peaks due to conical vortices is the use of some non-standard parapet configuration like cantilever parapets. In this paper the influence of roof curvature on the conical vortex pattern appearing on a curved roof (Fig. 1) when subject to oblique winds is experimentally analysed by testing the mean pressure distribution on the curved roofs of low-rise building models in a wind tunnel. Also, the efficiency of cantilever parapets to reduce mean suction loads on curved roofs is experimentally checked. Very high suction loads have been measured on curved roofs, the magnitude of these high suction loads being significantly decreased when cantilever parapets are used. Thus, the suitability of these parapets to reduce wind pressure loads on curved roofs is demonstrated.
Resumo:
The effect of an upstream building on the suction forces on the flat roof of a low-rise building placed in the wake of the former is analyzed. The analysis has been performed by wind tunnel testing of a flat roof, low-rise building model equipped with pressure taps on the roof and different block-type buildings (only configurations where the upstream building is as high or higher than the downstream one are considered in this paper). The influence of the distance between both buildings on the wind loads on the downstream building roof is analyzed, as well as the height of the upstream one and the wind angle of incidence. Experimental results reveal that the wind load increases as the relative height of the upstream building increases, the wind load being highest for intermediate distances between buildings, when a passage between them is formed.
Resumo:
The calibration coefficients of several models of cup and propeller anemometers were analysed. The analysis was based on a series of laboratory calibrations between January 2003 and August 2007. Mean and standard deviation values of calibration coefficients from the anemometers studied were included. Two calibration procedures were used and compared. In the first, recommended by the Measuring network of Wind Energy Institutes (MEASNET), 13 measurement points were taken over a wind speed range of 4 to 16 m s−1. In the second procedure, 9 measurement points were taken over a wider speed range of 4 to 23 m s−1. Results indicated no significant differences between the two calibration procedures applied to the same anemometer in terms of measured wind speed and wind turbines' Annual Energy Production (AEP). The influence of the cup anemometers' design on the calibration coefficients was also analysed. The results revealed that the slope of the calibration curve, if based on the rotation frequency and not the anemometer's output frequency, seemed to depend on the cup center rotation radius.
Resumo:
Here, Vortex-Induced Vibrations (VIVs) of a circular cylinder are analyzed as a potential source for energy harvesting. To this end, VIV is described by a one-degree-of-freedom model where fluid forces are introduced from experimental data from forced vibration tests. The influence of some influencing parameters, like the mass ratio m∗ or the mechanical damping ζ in the energy conversion factor is investigated. The analysis reveals that: (i) the maximum efficiency ηM is principally influenced by the mass-damping parameter m∗ζ and there is an optimum value of m∗ζ where ηM presents a maximum; (ii) the range of reduced velocities with significant efficiency is mainly governed by m∗, and (iii) it seems that encouraging high efficiency values can be achieved for high Reynolds numbers.
Resumo:
The calibration results (the transfer function) of an anemometer equipped with several cup rotors were analyzed and correlated with the aerodynamic forces measured on the isolated cups in a wind tunnel. The correlation was based on a Fourier analysis of the normal-to-the-cup aerodynamic force. Three different cup shapes were studied: typical conical cups, elliptical cups and porous cups (conical-truncated shape). Results indicated a good correlation between the anemometer factor, K, and the ratio between the first two coefficients in the Fourier series decomposition of the normal-to-the-cup aerodynamic force
Resumo:
In the present study the geometry of cups is experimentally studied through anemometer performance. This performance is analyzed in two different ways. On the one hand the anemometer transfer function between cases is compared. On the other hand the stationary rotation speed is decomposed into constant and harmonic terms, the comparison being established between the last ones. Results indicate that some cup shapes can improve the uniformity of anemometer rotation, this fact being important to reduce degradation due to ageing.
Resumo:
The 1-diode/2-resistors electric circuit equivalent to a photovoltaic system is analyzed. The equations at particular points of the I–V curve are studied considering the maximum number of terms. The maximum power point as a boundary condition is given special attention. A new analytical method is developed based on a reduced amount of information, consisting in the normal manufacturer data. Results indicate that this new method is faster than numerical methods and has similar (or better) accuracy than other existing methods, numerical or analytical.
Resumo:
The cup anemometer has been used widely by the wind energy industry since its early beginning, covering two fundamental aspects: wind mill performance control and wind energy production forecast. Furthermore, despite modern technological advances such as LIDAR and SODAR, the cup anemometer remains clearly the most used instrument by the wind energy industry. Together with the major advantages of this instrument (precision, robustness), some issues must be taken into account by scientists and researchers when using it. Overspeeding, interaction with stream wakes due to allocation on masts and wind- mills, loss of performance due to wear and tear, change of performance due to different climatic conditions, checking of the maintenance status and recalibration, etc. In the present work a review of the research campaigns carried out at the IDR/UPM Institute to analyze cup anemometer performance is included. Several aspects of this instrument are examined: the calibration process, the loss of performances due to aging and wear and tear, the effect of changes of air density, the rotor aerodynamics, and the harmonic terms contained in the anemometer output signal and their possible relation to the anemometer performances.
Resumo:
Due to the high dependence of photovoltaic energy efficiency on environmental conditions (temperature, irradiation...), it is quite important to perform some analysis focusing on the characteristics of photovoltaic devices in order to optimize energy production, even for small-scale users. The use of equivalent circuits is the preferred option to analyze solar cells/panels performance. However, the aforementioned small-scale users rarely have the equipment or expertise to perform large testing/calculation campaigns, the only information available for them being the manufacturer datasheet. The solution to this problem is the development of new and simple methods to define equivalent circuits able to reproduce the behavior of the panel for any working condition, from a very small amount of information. In the present work a direct and completely explicit method to extract solar cell parameters from the manufacturer datasheet is presented and tested. This method is based on analytical formulation which includes the use of the Lambert W-function to turn the series resistor equation explicit. The presented method is used to analyze the performance (i.e., the I - V curve) of a commercial solar panel at different levels of irradiation and temperature. The analysis performed is based only on the information included in the manufacturer's datasheet.
Resumo:
At present, photovoltaic energy is one of the most important renewable energy sources. The demand for solar panels has been continuously growing, both in the industrial electric sector and in the private sector. In both cases the analysis of the solar panel efficiency is extremely important in order to maximize the energy production. In order to have a more efficient photovoltaic system, the most accurate understanding of this system is required. However, in most of the cases the only information available in this matter is reduced, the experimental testing of the photovoltaic device being out of consideration, normally for budget reasons. Several methods, normally based on an equivalent circuit model, have been developed to extract the I-V curve of a photovoltaic device from the small amount of data provided by the manufacturer. The aim of this paper is to present a fast, easy, and accurate analytical method, developed to calculate the equivalent circuit parameters of a solar panel from the only data that manufacturers usually provide. The calculated circuit accurately reproduces the solar panel behavior, that is, the I-V curve. This fact being extremely important for practical reasons such as selecting the best solar panel in the market for a particular purpose, or maximize the energy extraction with MPPT (Maximum Peak Power Tracking) methods.