Influence of an upstream building on the wind-induced mean suction on the flat roof of a low-rise building


Autoria(s): Pindado Carrion, Santiago; Meseguer Ruiz, José; Franchini, Sebastián
Data(s)

2011

Resumo

The effect of an upstream building on the suction forces on the flat roof of a low-rise building placed in the wake of the former is analyzed. The analysis has been performed by wind tunnel testing of a flat roof, low-rise building model equipped with pressure taps on the roof and different block-type buildings (only configurations where the upstream building is as high or higher than the downstream one are considered in this paper). The influence of the distance between both buildings on the wind loads on the downstream building roof is analyzed, as well as the height of the upstream one and the wind angle of incidence. Experimental results reveal that the wind load increases as the relative height of the upstream building increases, the wind load being highest for intermediate distances between buildings, when a passage between them is formed.

Formato

application/pdf

Identificador

http://oa.upm.es/30432/

Idioma(s)

eng

Relação

http://oa.upm.es/30432/1/JWEIA2011.pdf

http://www.sciencedirect.com/science/article/pii/S0167610511001176

info:eu-repo/semantics/altIdentifier/doi/10.1016/j.jweia.2011.06.003

Direitos

http://creativecommons.org/licenses/by-nc-nd/3.0/es/

info:eu-repo/semantics/openAccess

Fonte

Journal of Wind Engineering and Industrial Aerodynamics, ISSN 0167-6105, 2011, Vol. 99, No. 8

Palavras-Chave #Ingeniería Civil y de la Construcción
Tipo

info:eu-repo/semantics/article

Artículo

PeerReviewed