39 resultados para Buildings, Wooden


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reducing energy consumption and eliminating wastage are among the main goals of the European Union (EU) [2]. In order to satisfy all challenges arising from the Kyoto protocol, improving energy efficiency is a very important factor to take into account. There is significant potential for reducing consumption with cost-effective measures. Some studies show that 40% of our energy is consumed in buildings, and the EU has introduced legislation that aims to ensure that less energy is consumed in this way in the future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

On Wednesday 11th May 2011 at 6:47 pm (local time) a magnitude 5.1 Mw earthquake occurred 6 km northeast of Lorca with a depth of around 2 km. As a consequence of the shallow depth and the small epicentral distance, important damage was produced in several masonry constructions and even led to the collapse of some of them. Pieces of the facades of several buildings fell down onto the sidewalk, being one of the reasons for the killing of a total of 9 people. The objective of this paper is to describe and analyze the failure patterns observed in unreinforced masonry buildings ranging from 3 to 8 floors in height. First, a brief description of the local building practices of masonry buildings is given. Then, the most important failure types of masonry buildings are described and discussed. After that, a more detailed analysis of one particular building is presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A significant number of short-to-mid height RC buildings with wide beams have been constructed in areas of moderate seismicity of Spain, mainly for housing and administrative use. The buildings have a framed structure with one-way slabs; the wide beams constitute the distinctive characteristic, their depth being equal to that of the rest of the slab, thus providing a flat lower surface, convenient for construction and the layout of facilities. Seismic behavior in the direction of the wide beams appears to be deficient because of: (i) low lateral strength, mainly because of the small effective depth of the beams, (ii) inherent low ductility of the wide beams, generated by high amount of reinforcement, (iii) the big strut compressive forces developed inside the column-beam connections due to the low height of the beams, and (iv) the fact that the wide beams are wider than the columns, meaning that the contribution of the outer zones to the resistance of the beam-column joints is unreliable because there is no torsion reinforcement. In the orthogonal direction, the behavior is worse since the only members of the slabs that contribute to the lateral resistance are the joists and the façade beams. Moreover, these buildings were designed with codes that did not include ductility requirements and required only a low lateral resistance; indeed, in many cases, seismic action was not considered at all. Consequently, the seismic capacity of these structures is not reliable. The objective of this research is to assess numerically this capability, whereas further research will aim to propose retrofit strategies. The research approach consists of: (i) selecting a number of 3-story and 6-story buildings that represent the vast majority of the existing ones and (ii) evaluating their vulnerability through three types of analyses, namely: code-type, push-over and nonlinear dynamic analysis. Given the low lateral resistance of the main frames, the cooperation of the masonry infill walls is accounted for; for each representative building, three wall densities are considered. The results of the analyses show that the buildings in question exhibit inadequate seismic behavior in most of the examined situations. In general, the relative performance is less deficient for Target Drift CP (Collapse Prevention) than for IO (Immediate Occupancy). Since these buildings are selected to be representative of the vast majority of buildings with wide beams that were constructed in Spain without accounting for any seismic consideration, our conclusions can be extrapolated to a broader scenario.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The technique of reinforcement of wooden floors is a matter clearly multidisciplinary. The teaching of the subject using the "traditional" method, explaining the theory first and then proposing and solving problems has not been successful. This paper discusses the results of a teaching experiencie. It has been the teaching of the subject by the case method. The results are clearly superior to those obtained with the traditional methodology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The application of conservation treatments, such as consolidation and protection ones, has been demonstrated ineffective in many cases, and even harmful. Evaluation studies should be a mandatory task, ideally before and after the intervention, but both tasks are complex and unusual in the case of archaeological heritage. This study is mainly focused on analyzing changes in petrophysical properties of stone material from archaeological sites of Merida (Spain), evaluating, both on site and in laboratory, effects derived from different conservation treatments applied in past interventions, throughout the integration of different non-destructive techniques (NDT) and portable devices of analysis available at the Institute of Geosciences (CSIC,UCM). These techniques allow, not only assessment of effectiveness and alteration processes, but also monitoring durability of treatments, focused mainly on 1996 intervention in the case of Roman Theater, as well as different punctual interventions from the 90?s until date in the House of Mitreo. Studies carried out on archaeological sites of Merida permit us to compare outcomes and also check limitations in the use of those equipments. In this paper we discuss about the use of some techniques, their integration and limits, for the assessment of conservation treatments, showing some examples of Merida?s case study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Proyecto wooden house

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is no doubt that there is no possibility of finding a single reference about domotics in the first half of the 20th century. The best known authors and those who have documented this discipline, set its origin in the 1970’s, when the x-10 technology began to be used, but it was not until 1988 when Larousse Encyclopedia decided to include the definition of "Smart Building". Furthermore, even nowadays, there is not a single definition widely accepted, and for that reason, many other expressions, namely "Intelligent Buildings" "Domotics" "Digital Home" or "Home Automation" have appeared to describe the automated buildings and homes. The lack of a clear definition for "Smart Buildings" causes difficulty not only in the development of a common international framework to develop research in this field, but it also causes insecurity in the potential user of these buildings. That is to say, the user does not know what is offered by this kind of buildings, hindering the dissemination of the culture of building automation in society. Thus, the main purpose of this paper is to propose a definition of the expression “Smart Buildings” that satisfactorily describes the meaning of this discipline. To achieve this aim, a thorough review of the origin of the term itself and the historical background before the emergence of the phenomenon of domotics was conducted, followed by a critical discussion of existing definitions of the term "Smart Buildings" and other similar terms. The extent of each definition has been analyzed, inaccuracies have been discarded and commonalities have been compared. Throughout the discussion, definitions that bring the term "Smart Buildings" near to disciplines such as computer science, robotics and also telecommunications have been found. However, there are also many other definitions that emphasize in a more abstract way the role of these new buildings in the society and the future of mankind.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High suction loads appear on roofs of low-height buildings. The use of parapets with appropriate height at the roof edges alleviates these loads. The performance of six parapet configurations to decrease the suction loads induced on roofs by oblique winds has been studied in a low speed wind tunnel. The studied parapet configurations include vertical wall parapets, either solid or porous, and cantilevered parapets formed by a small horizontal roof close to the building roof. Low-height parapets with a medium porosity and cantilevered parapets are more efficient than solid parapets to reduce the wind suctions generated on the roofs by conical vortices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Different methods to reduce the high suction caused by conical vortices have been reported in the literature: vertical parapets, either solid or porous, placed at the roof edges being the most analysed configuration. Another method for alleviating the high suction peaks due to conical vortices is the use of some non-standard parapet configuration like cantilever parapets. In this paper the influence of roof curvature on the conical vortex pattern appearing on a curved roof (Fig. 1) when subject to oblique winds is experimentally analysed by testing the mean pressure distribution on the curved roofs of low-rise building models in a wind tunnel. Also, the efficiency of cantilever parapets to reduce mean suction loads on curved roofs is experimentally checked. Very high suction loads have been measured on curved roofs, the magnitude of these high suction loads being significantly decreased when cantilever parapets are used. Thus, the suitability of these parapets to reduce wind pressure loads on curved roofs is demonstrated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

On Wednesday 11th May 2011 at 6:47 pm (local time) a magnitude 5.1 Mw earthquake occurred 6 km northeast of Lorca with a depth of around 5 km. As a consequence of the shallow depth and the small epicentral distance, important damage was produced in several masonry constructions and even led to the collapse of one of them. Pieces of the facades of several buildings fell down onto the sidewalk, being one of the reasons for the killing of a total of 9 people. The objective of this paper is to describe and analyze the failure patterns observed in reinforced concrete frame buildings with masonry infill walls ranging from 3 to 8 floors in height. Structural as well as non-structural masonry walls suffered important damage that led to redistributions of forces causing in some cases the failure of columns. The importance of the interaction between the structural frames and the infill panels is analyzed by means of non-linear Finite Element Models. The resulting load levels are compared with the member capacities and the changes of the mechanical properties during the seismic event are described and discussed. In the light of the results obtained the observed failure patterns are explained. Some comments are stated concerning the adequacy of the numerical models that are usually used during the design phase for the seismic analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This book review states that parts of this interesting volume may prove useful as a reference for designers and researchers in the field, though it lacks somewhat in unity and various important topics are not covered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Air Mines The sky over the city's port was the color of a faulty screen, only partly lit up. As the silhouette of nearby buildings became darker, but more clearly visible against the fading blur-filter of a background, the realization came about how persistent a change had been taking place. Slowly, old wooden water reservoirs and rattling HVAC systems stopped being the only inhabitants of roofs. Slightly trembling, milkish jellyfish-translucent air volumes had joined the show in multiples. A few years ago artists and architects seized upon the death of buildings as their life-saving media. Equipped with constructive atlases and instruments they started disemboweling their subjects, poking about their systems, dumping out on the street the battered ugliness of their embarrassing bits and pieces, so rightly hidden by facades and height from everyday view. But, would you believe it? Even ?old ladies?, investment bankers or small children failed to get upset. Of course, old ladies are not what they used to be. It was old ladies themselves that made it happen after years of fights with the town hall, imaginative proposals and factual arguments. An industry with little financial gains but lots of welcome externalities was not, in fact, the ground for investment bankers. But they too had to admit that having otherwise stately buildings make fine particulate pencils with their facades was not the worse that could happen. Yes, making soot pencils had been found an interesting and visible end product of the endeavor, a sort of mining the air for vintage writing tools one can actually touch. The new view from the street did not seem as solid or dignified as that of old, and they hated that the market for Fine Particulates Extraction (FPE, read efpee) had to be applied on a matrix of blocks and streets that prevented undue concentration of the best or worse solutions. It had to be an evenly distributed city policy in order for the city to apply for cleaning casino money. Once the first prototypes had been deployed in buildings siding Garden Avenue or Bulwark Street even fast movers appreciated the sidekick of flower and plant smell dripping down the Urban Space Stations (USS, read use; USSs, read uses) as air and walls cooled off for a few hours after sunset. Enough. It was all nice to remember, but it was now time to go up and start the lightweight afternoon maintenance of their USS. Coop discussions had taken place all through the planning and continued through the construction phase as to how maintenance was going to be organized. Fasters had voted for a pro, pay a small amount and let them use it for rent and produce. In the end some neighbors decided they were slow enough to take care and it was now the turn. Regret came periodically, sometimes a week before, and lasted until work actually started. But lately it had been replaced by anxiety when it needed to be passed over to the next caretaker. It did not look their shift was good enough and couldn?t wait to fix it. Today small preparations needed to be made for a class visit next day from a nearby cook school. They were frequenters. It had not been easy, but it shouldn?t have been that hard. In the end, even the easiest things are hard if they involve a city, buildings and neighbors. On the face of the data, the technicalities and the way final designs had been worked out for adaptation to the different settings, the decision of where to go was self evident, but organization issues and the ever-growing politics of taste in a city of already-gentrified-rodents almost put the project in the frozen orbit of timeless beautiful future possibilities. This is how it was. A series of designs by XClinic and OSS had made it possible to adapt to different building structures, leave in most cases the roof untouched and adapted a new technology of flexing fiberglass tubes that dissipated wind pressure in smooth bending.......

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study analyses the differences between two calculation models for guardrails on building sites that use wooden boards and tubular steel posts. Wood was considered an isotropic material in one model and an orthotropic material in a second model. The elastic constants of the wood were obtained with ultrasound. Frequencies and vibration modes were obtained for both models through linear analysis using the finite element method. The two models were experimentally calibrated through operational modal analysis. The results obtained show that for the three types of wood under analysis, the model which considered them as an orthotropic material fitted the experimental results better than the model which considered them as an isotropic material.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The city of Lorca (Spain) was hit on May 11th, 2011, by two consecutive earth-quakes of magnitudes 4.6 and 5.2 Mw, causing casualties and important damage in buildings. Many of the damaged structures were reinforced concrete frames with wide beams. This study quantifies the expected level of damage on this structural type in the case of the Lorca earth-quake by means of a seismic index Iv that compares the energy input by the earthquake with the energy absorption/dissipation capacity of the structure. The prototype frames investigated represent structures designed in two time periods (1994–2002 and 2003–2008), in which the applicable codes were different. The influence of the masonry infill walls and the proneness of the frames to concentrate damage in a given story were further investigated through nonlinear dynamic response analyses. It is found that (1) the seismic index method predicts levels of damage that range from moderate/severe to complete collapse; this prediction is consistent with the observed damage; (2) the presence of masonry infill walls makes the structure very prone to damage concentration and reduces the overall seismic capacity of the building; and (3) a proper hierarchy of strength between beams and columns that guarantees the formation of a strong column-weak beam mechanism (as prescribed by seismic codes), as well as the adoption of counter-measures to avoid the negative interaction between non-structural infill walls and the main frame, would have reduced the level of damage from Iv=1 (collapse) to about Iv=0.5 (moderate/severe damage)