41 resultados para Airport buildings.
Resumo:
Experimental research on imposed deformation is generally conducted on small scale laboratory experiments. The attractiveness of field research lies in the possibility to compare results obtained from full scale structures to theoretical prediction. Unfortunately, measurements obtained from real structures are rarely described in literature. The structural response of integral edifices depends significantly on stiffness changes and constraints. The New Airport Terminal Barajas in Madrid, Spain provides with large integral modules, partially post?tensioned concrete frames, cast monolithically over three floor levels and an overall length of approx. 80 m. The field campaign described in this article explains the instrumentation of one of these frames focusing on the influence of imposed deformations such as creep, shrinkage and temperature. The applied monitoring equipment included embedded strain gages, thermocouples, DEMEC measurements and simple displacement measurements. Data was collected throughout construction and during two years of service. A complete data range of five years is presented and analysed. The results are compared with a simple approach to predict the long?term shortening of this concrete structure. Both analytical and experimental results are discussed.
Resumo:
Reducing energy consumption and eliminating wastage are among the main goals of the European Union (EU) [2]. In order to satisfy all challenges arising from the Kyoto protocol, improving energy efficiency is a very important factor to take into account. There is significant potential for reducing consumption with cost-effective measures. Some studies show that 40% of our energy is consumed in buildings, and the EU has introduced legislation that aims to ensure that less energy is consumed in this way in the future.
Resumo:
On Wednesday 11th May 2011 at 6:47 pm (local time) a magnitude 5.1 Mw earthquake occurred 6 km northeast of Lorca with a depth of around 2 km. As a consequence of the shallow depth and the small epicentral distance, important damage was produced in several masonry constructions and even led to the collapse of some of them. Pieces of the facades of several buildings fell down onto the sidewalk, being one of the reasons for the killing of a total of 9 people. The objective of this paper is to describe and analyze the failure patterns observed in unreinforced masonry buildings ranging from 3 to 8 floors in height. First, a brief description of the local building practices of masonry buildings is given. Then, the most important failure types of masonry buildings are described and discussed. After that, a more detailed analysis of one particular building is presented.
Resumo:
A significant number of short-to-mid height RC buildings with wide beams have been constructed in areas of moderate seismicity of Spain, mainly for housing and administrative use. The buildings have a framed structure with one-way slabs; the wide beams constitute the distinctive characteristic, their depth being equal to that of the rest of the slab, thus providing a flat lower surface, convenient for construction and the layout of facilities. Seismic behavior in the direction of the wide beams appears to be deficient because of: (i) low lateral strength, mainly because of the small effective depth of the beams, (ii) inherent low ductility of the wide beams, generated by high amount of reinforcement, (iii) the big strut compressive forces developed inside the column-beam connections due to the low height of the beams, and (iv) the fact that the wide beams are wider than the columns, meaning that the contribution of the outer zones to the resistance of the beam-column joints is unreliable because there is no torsion reinforcement. In the orthogonal direction, the behavior is worse since the only members of the slabs that contribute to the lateral resistance are the joists and the façade beams. Moreover, these buildings were designed with codes that did not include ductility requirements and required only a low lateral resistance; indeed, in many cases, seismic action was not considered at all. Consequently, the seismic capacity of these structures is not reliable. The objective of this research is to assess numerically this capability, whereas further research will aim to propose retrofit strategies. The research approach consists of: (i) selecting a number of 3-story and 6-story buildings that represent the vast majority of the existing ones and (ii) evaluating their vulnerability through three types of analyses, namely: code-type, push-over and nonlinear dynamic analysis. Given the low lateral resistance of the main frames, the cooperation of the masonry infill walls is accounted for; for each representative building, three wall densities are considered. The results of the analyses show that the buildings in question exhibit inadequate seismic behavior in most of the examined situations. In general, the relative performance is less deficient for Target Drift CP (Collapse Prevention) than for IO (Immediate Occupancy). Since these buildings are selected to be representative of the vast majority of buildings with wide beams that were constructed in Spain without accounting for any seismic consideration, our conclusions can be extrapolated to a broader scenario.
Resumo:
The application of conservation treatments, such as consolidation and protection ones, has been demonstrated ineffective in many cases, and even harmful. Evaluation studies should be a mandatory task, ideally before and after the intervention, but both tasks are complex and unusual in the case of archaeological heritage. This study is mainly focused on analyzing changes in petrophysical properties of stone material from archaeological sites of Merida (Spain), evaluating, both on site and in laboratory, effects derived from different conservation treatments applied in past interventions, throughout the integration of different non-destructive techniques (NDT) and portable devices of analysis available at the Institute of Geosciences (CSIC,UCM). These techniques allow, not only assessment of effectiveness and alteration processes, but also monitoring durability of treatments, focused mainly on 1996 intervention in the case of Roman Theater, as well as different punctual interventions from the 90?s until date in the House of Mitreo. Studies carried out on archaeological sites of Merida permit us to compare outcomes and also check limitations in the use of those equipments. In this paper we discuss about the use of some techniques, their integration and limits, for the assessment of conservation treatments, showing some examples of Merida?s case study.
Resumo:
There is no doubt that there is no possibility of finding a single reference about domotics in the first half of the 20th century. The best known authors and those who have documented this discipline, set its origin in the 1970’s, when the x-10 technology began to be used, but it was not until 1988 when Larousse Encyclopedia decided to include the definition of "Smart Building". Furthermore, even nowadays, there is not a single definition widely accepted, and for that reason, many other expressions, namely "Intelligent Buildings" "Domotics" "Digital Home" or "Home Automation" have appeared to describe the automated buildings and homes. The lack of a clear definition for "Smart Buildings" causes difficulty not only in the development of a common international framework to develop research in this field, but it also causes insecurity in the potential user of these buildings. That is to say, the user does not know what is offered by this kind of buildings, hindering the dissemination of the culture of building automation in society. Thus, the main purpose of this paper is to propose a definition of the expression “Smart Buildings that satisfactorily describes the meaning of this discipline. To achieve this aim, a thorough review of the origin of the term itself and the historical background before the emergence of the phenomenon of domotics was conducted, followed by a critical discussion of existing definitions of the term "Smart Buildings" and other similar terms. The extent of each definition has been analyzed, inaccuracies have been discarded and commonalities have been compared. Throughout the discussion, definitions that bring the term "Smart Buildings" near to disciplines such as computer science, robotics and also telecommunications have been found. However, there are also many other definitions that emphasize in a more abstract way the role of these new buildings in the society and the future of mankind.
Resumo:
The current deficit situation of the Spanish airport system suggests the need to manage this in a more efficient and profitable way. One of the possible options is through private management and being able to do this through Public Private Partnerships (PPP). This study analyzes the situation of the sector and its economic importance and the different possibilities for introducing private management in a public company, specifying the situation in the case of airports, presenting the advantages and disadvantages of these possibilities, and aiming at results obtained in other places where it has been applied. It is proposed that the ideal model for the introduction of private management would be through PPP models tailored to each airport, but having common characteristics according to the group they belong to. Finally, we observe that not all airports are commercially attractive, so that the PPP concept does not apply to all of them. In some cases even the operability itself is not viable at all, and that should be considered separately in order to avoid creating a private monopoly while trying to enhance competition among them.
Resumo:
High suction loads appear on roofs of low-height buildings. The use of parapets with appropriate height at the roof edges alleviates these loads. The performance of six parapet configurations to decrease the suction loads induced on roofs by oblique winds has been studied in a low speed wind tunnel. The studied parapet configurations include vertical wall parapets, either solid or porous, and cantilevered parapets formed by a small horizontal roof close to the building roof. Low-height parapets with a medium porosity and cantilevered parapets are more efficient than solid parapets to reduce the wind suctions generated on the roofs by conical vortices.
Resumo:
Different methods to reduce the high suction caused by conical vortices have been reported in the literature: vertical parapets, either solid or porous, placed at the roof edges being the most analysed configuration. Another method for alleviating the high suction peaks due to conical vortices is the use of some non-standard parapet configuration like cantilever parapets. In this paper the influence of roof curvature on the conical vortex pattern appearing on a curved roof (Fig. 1) when subject to oblique winds is experimentally analysed by testing the mean pressure distribution on the curved roofs of low-rise building models in a wind tunnel. Also, the efficiency of cantilever parapets to reduce mean suction loads on curved roofs is experimentally checked. Very high suction loads have been measured on curved roofs, the magnitude of these high suction loads being significantly decreased when cantilever parapets are used. Thus, the suitability of these parapets to reduce wind pressure loads on curved roofs is demonstrated.
Resumo:
On Wednesday 11th May 2011 at 6:47 pm (local time) a magnitude 5.1 Mw earthquake occurred 6 km northeast of Lorca with a depth of around 5 km. As a consequence of the shallow depth and the small epicentral distance, important damage was produced in several masonry constructions and even led to the collapse of one of them. Pieces of the facades of several buildings fell down onto the sidewalk, being one of the reasons for the killing of a total of 9 people. The objective of this paper is to describe and analyze the failure patterns observed in reinforced concrete frame buildings with masonry infill walls ranging from 3 to 8 floors in height. Structural as well as non-structural masonry walls suffered important damage that led to redistributions of forces causing in some cases the failure of columns. The importance of the interaction between the structural frames and the infill panels is analyzed by means of non-linear Finite Element Models. The resulting load levels are compared with the member capacities and the changes of the mechanical properties during the seismic event are described and discussed. In the light of the results obtained the observed failure patterns are explained. Some comments are stated concerning the adequacy of the numerical models that are usually used during the design phase for the seismic analysis.
Resumo:
This book review states that parts of this interesting volume may prove useful as a reference for designers and researchers in the field, though it lacks somewhat in unity and various important topics are not covered.
Resumo:
An architecture of light and shadows is proposed for this airport for the twenty-first century. A great concrete and stone box to frame the incredible view south towards a red mountain that rests Sphinx-like over the Atlantic. = Se propone para este aeropuerto para el siglo XXI una arquitectura construída con la luz y con las sombras. Una gran caja de hormigón que enmarca un maravilloso paisaje: el océano atlántico al sur con la montaña roja que se acuesta sobre el mar como si de una esfinge se tratara.
Resumo:
Tenerife South Airport (Phase II)
Resumo:
In collaboration with Arsenio Pérez Amaral, Antonio Corona and Eustaquio Martínez