Building monitoring during the partial implosion stage


Autoria(s): Garcés Lengua, Julio; Botero, J.C.
Contribuinte(s)

Muriá Vila, David

Cobertura

Medellín de: Lat: 06 15 00 N degrees minutes Lat: 6.2500 decimal degrees Long: 075 36 00 W degrees minutes Long: -75.6000 decimal degrees

Data(s)

03/06/2016

2015

03/06/2016

Resumo

The partial collapse of a building in Colombia caused severe damage to its structural components -- An implosion was realized to induce the collapse of 50% of the deteriorated building -- To evaluate the influence of the implosion on the remaining structure, a monitoring survey was realized using triaxial accelerometers -- Time signals associated with ambient, seismic and forced vibration were obtained -- A study of the records in the time and the frequency domain was made -- The analysis of the information allowed determining some structural properties that were useful to calibrate the analytical model of the structure

Identificador

624.17CDG215

http://hdl.handle.net/10784/8546

Idioma(s)

spa

Publicador

Universidad EAFIT

Maestría en Ingeniería

Escuela de Ingeniería

Direitos

info:eu-repo/semantics/openAccess

openAccess

Libre acceso

Palavras-Chave #Edificio Space (Medellín) #ONDAS SÍSMICAS #EDIFICIOS #VIBRACIÓN - MEDICIONES #ACELERÓMETROS #DEMOLICIONES #CONSTRUCCIONES ANTISÍSMICAS #DINÁMICA DE ESTRUCTURAS #TEORÍA DE LAS ESTRUCTURAS #Buildings #Seismic waves #Vibration - Measurement #Accelerometers #Wrecking #Earthquakes and building #Structural dynamics #Structures, Theory of
Tipo

masterThesis

info:eu-repo/semantics/masterThesis

Tesis de Maestría

acceptedVersion