530 resultados para ANGIOGRAPHY
Resumo:
Background. Cardiovascular disease (CVD) remains the most serious threat to life and health in industrialized countries. Atherosclerosis is the main underlying pathology associated with CVD, in particular coronary artery disease (CAD), ischaemic stroke, and peripheral arterial disease. Risk factors play an important role in initiating and accelerating the complex process of atherosclerosis. Most studies of risk factors have focused on the presence or absence of clinically defined CVD. Less is known about the determinants of the severity and extent of atherosclerosis in symptomatic patients. Aims. To clarify the association between coronary and carotid artery atherosclerosis, and to study the determinants associated with these abnormalities with special regard to novel cardiovascular risk factors. Subjects and methods. Quantitative coronary angiography (QCA) and B-mode ultrasound were used to assess coronary and carotid artery atherosclerosis in 108 patients with clinically suspected CAD referred for elective coronary angiography. To evaluate anatomic severity and extent of CAD, several QCA parameters were incorporated into indexes. These measurements reflected CAD severity, extent, and overall atheroma burden and were calculated for the entire coronary tree and separately for different coronary segments (i.e., left main, proximal, mid, and distal segments). Maximum and mean intima-media thickness (IMT) values of carotid arteries were measured and expressed as mean aggregate values. Furthermore, the study design included extensive fasting blood samples, oral glucose tolerance test, and an oral fat-load test to be performed in each participant. Results. Maximum and mean IMT values were significantly correlated with CAD severity, extent, and atheroma burden. There was heterogeneity in associations between IMT and CAD indexes according to anatomical location of CAD. Maximum and mean IMT values, respectively, were correlated with QCA indexes for mid and distal segments but not with the proximal segments of coronary vessels. The values of paraoxonase-1 (PON1) activity and concentration, respectively, were lower in subjects with significant CAD and there was a significant relationship between PON1 activity and concentration and coronary atherosclerosis assessed by QCA. PON1 activity was a significant determinant of severity of CAD independently of HDL cholesterol. Neither PON1 activity nor concentration was associated with carotid IMT. The concentration of triglycerides (TGs), triglyceride-rich lipoproteins (TRLs), oxidized LDL (oxLDL), and the cholesterol content of remnant lipoprotein particle (RLP-C) were significantly increased at 6 hours after intake of an oral fatty meal as compared with fasting values. The mean peak size of LDL remained unchanged 6 hours after the test meal. The correlations between total TGs, TRLs, and RLP-C in fasting and postprandial state were highly significant. RLP-C correlated with oxLDL both in fasting and in fed state and inversely with LDL size. In multivariate analysis oxLDL was a determinant of severity and extent of CAD. Neither total TGs, TRLs, oxLDL, nor LDL size were linked to carotid atherosclerosis. Insulin resistance (IR) was associated with an increased severity and extent of coronary atherosclerosis and seemed to be a stronger predictor of coronary atherosclerosis in the distal parts of the coronary tree than in the proximal and mid parts. In the multivariate analysis IR was a significant predictor of the severity of CAD. IR did not correlate with carotid IMT. Maximum and mean carotid IMT were higher in patients with the apoE4 phenotype compared with subjects with the apoE3 phenotype. Likewise, patients with the apoE4 phenotype had a more severe and extensive CAD than individuals with the apoE3 phenotype. Conclusions. 1) There is an association between carotid IMT and the severity and extent of CAD. Carotid IMT seems to be a weaker predictor of coronary atherosclerosis in the proximal parts of the coronary tree than in the mid and distal parts. 2) PON1 activity has an important role in the pathogenesis of coronary atherosclerosis. More importantly, the study illustrates how the protective role of HDL could be modulated by its components such that equivalent serum concentrations of HDL cholesterol may not equate with an equivalent, potential protective capacity. 3) RLP-C in the fasting state is a good marker of postprandial TRLs. Circulating oxLDL increases in CAD patients postprandially. The highly significant positive correlation between postprandial TRLs and postprandial oxLDL suggests that the postprandial state creates oxidative stress. Our findings emphasize the fundamental role of LDL oxidation in the development of atherosclerosis even after inclusion of conventional CAD risk factors. 4) Disturbances in glucose metabolism are crucial in the pathogenesis of coronary atherosclerosis. In fact, subjects with IR are comparable with diabetic subjects in terms of severity and extent of CAD. 5) ApoE polymorphism is involved in the susceptibility to both carotid and coronary atherosclerosis.
Resumo:
CT and digital subtraction angiography (DSA) are ubiquitous in the clinic. Their preclinical equivalents are valuable imaging methods for studying disease models and treatment. We have developed a dual source/detector X-ray imaging system that we have used for both micro-CT and DSA studies in rodents. The control of such a complex imaging system requires substantial software development for which we use the graphical language LabVIEW (National Instruments, Austin, TX, USA). This paper focuses on a LabVIEW platform that we have developed to enable anatomical and functional imaging with micro-CT and DSA. Our LabVIEW applications integrate and control all the elements of our system including a dual source/detector X-ray system, a mechanical ventilator, a physiological monitor, and a power microinjector for the vascular delivery of X-ray contrast agents. Various applications allow cardiac- and respiratory-gated acquisitions for both DSA and micro-CT studies. Our results illustrate the application of DSA for cardiopulmonary studies and vascular imaging of the liver and coronary arteries. We also show how DSA can be used for functional imaging of the kidney. Finally, the power of 4D micro-CT imaging using both prospective and retrospective gating is shown for cardiac imaging.
Resumo:
Coronary CT angiography is widely used in clinical practice for the assessment of coronary artery disease. Several studies have shown that the same exam can also be used to assess left ventricle (LV) function. LV function is usually evaluated using just the data from end-systolic and end-diastolic phases even though coronary CT angiography (CTA) provides data concerning multiple cardiac phases, along the cardiac cycle. This unused wealth of data, mostly due to its complexity and the lack of proper tools, has still to be explored in order to assess if further insight is possible regarding regional LV functional analysis. Furthermore, different parameters can be computed to characterize LV function and while some are well known by clinicians others still need to be evaluated concerning their value in clinical scenarios. The work presented in this thesis covers two steps towards extended use of CTA data: LV segmentation and functional analysis. A new semi-automatic segmentation method is presented to obtain LV data for all cardiac phases available in a CTA exam and a 3D editing tool was designed to allow users to fine tune the segmentations. Regarding segmentation evaluation, a methodology is proposed in order to help choose the similarity metrics to be used to compare segmentations. This methodology allows the detection of redundant measures that can be discarded. The evaluation was performed with the help of three experienced radiographers yielding low intraand inter-observer variability. In order to allow exploring the segmented data, several parameters characterizing global and regional LV function are computed for the available cardiac phases. The data thus obtained is shown using a set of visualizations allowing synchronized visual exploration. The main purpose is to provide means for clinicians to explore the data and gather insight over their meaning, as well as their correlation with each other and with diagnosis outcomes. Finally, an interactive method is proposed to help clinicians assess myocardial perfusion by providing automatic assignment of lesions, detected by clinicians, to a myocardial segment. This new approach has obtained positive feedback from clinicians and is not only an improvement over their current assessment method but also an important first step towards systematic validation of automatic myocardial perfusion assessment measures.
Resumo:
The mouse has emerged as an animal model for many diseases. At IRO, we have used this animal to understand the development of many eye diseases and treatment of some of them. Precise evaluation of vision is a prerequisite for both these approaches. In this unit we describe three ways to measure vision: testing the optokinetic response, and evaluating the fundus by direct observation and by fluorescent angiography.
Resumo:
The objective of this work was to develop an easily applicable technique and a standardized protocol for high-quality post-mortem angiography. This protocol should (1) increase the radiological interpretation by decreasing artifacts due to the perfusion and by reaching a complete filling of the vascular system and (2) ease and standardize the execution of the examination. To this aim, 45 human corpses were investigated by post-mortem computed tomography (CT) angiography using different perfusion protocols, a modified heart-lung machine and a new contrast agent mixture, specifically developed for post-mortem investigations. The quality of the CT angiographies was evaluated radiologically by observing the filling of the vascular system and assessing the interpretability of the resulting images and by comparing radiological diagnoses to conventional autopsy conclusions. Post-mortem angiography yielded satisfactory results provided that the volumes of the injected contrast agent mixture were high enough to completely fill the vascular system. In order to avoid artifacts due to the post-mortem perfusion, a minimum of three angiographic phases and one native scan had to be performed. These findings were taken into account to develop a protocol for quality post-mortem CT angiography that minimizes the risk of radiological misinterpretation. The proposed protocol is easy applicable in a standardized way and yields high-quality radiologically interpretable visualization of the vascular system in post-mortem investigations.
Resumo:
OBJECTIVE: Contemporary free-breathing non contrast enhanced cardiovascular magnetic resonance angiography (CMRA) was qualitatively and quantitatively evaluated to ascertain the reproducibility of the method for coronary artery luminal dimension measurements. SUBJECTS AND METHODS: Twenty-two healthy volunteers (mean age 32 +/- 7 years, 12 males) without coronary artery disease were imaged at 2 centers (1 each in Europe and North America) using navigator-gated and corrected SSFP CMRA on a commercial whole body 1.5T System. Repeat images of right (RCA, n = 21), left anterior descending (LAD, n = 14) and left circumflex (LCX, n = 14) coronary arteries were obtained in separate sessions using identical scan protocol and imaging parameters. True visible vessel length, signal-to-noise (SNR), contrast-to-noise ratios (CNR) and the average luminal diameter over the first 4 cm of the vessel were measured. Intra-observer, inter-observer and inter-scan reproducibility of coronary artery luminal diameter were determined using Pearson's correlation, Bland-Altman analysis and intraclass correlation coefficients (ICC). RESULTS: CNR, SNR and the mean length of the RCA, LAD and LCX imaged for original and repeat scans were not significantly different (all p > 0.30). There was a high degree of intra-observer, inter-observer and inter-scan agreements for RCA, LAD and LCX luminal diameter respectively on Bland-Altman and ICC analysis (ICC's for RCA: 0.98. 0.98 and 0.86; LAD: 0.89, 0.89 and 0.63; LCX: 0.95, 0.94 and 0.79). CONCLUSION: In a 2-center study, we demonstrate that free-breathing 3D SSFP CMRA can visualize long continuous segments of coronary vessels with highly reproducible measurements of luminal diameter.
Resumo:
Objective: Postmortem radiology had in recent years appeared in the field of forensic medicine and is now considered by some authors as a good replacement for conventional autopsy and by others as a complementary examination. Although postmortem CT radiological imaging is very useful in demonstrating traumatic lesions, its utility is still quite limited in the cardiovascular field. This limitation could be minimized by the introduction of postmortem angiography. At the University Center of Legal Medicine of Lausanne, CT scans and postmortem multiphase CTangiography are used in cases with a suspicion of ischemic heart disease.Method: The goal of this presentation is to demonstrate some correlations between postmortem CT, CTangiography and conventional autopsy examination in cases of ischemic heart disease.Results: We observed that the native CT scan can show only some pathological findings as cardiac tamponade and calcifications of coronary arteries. However, postmortem angiography allows a better visualization of coronary arteries and evaluation of stenosis and occlusion as well as better imaging of soft tissue.Conclusion: The interpretation of postmortem modern radiology is a new field for both forensic pathologists and radiologists who have to learn to read the postmortem modified images. The information obtained from both parties can help to further the understanding of CT and CT angiography in postmortem cases.
Resumo:
Purpose: To develop and evaluate a practical method for the quantification of signal-to-noise ratio (SNR) on coronary MR angiograms (MRA) acquired with parallel imaging.Materials and Methods: To quantify the spatially varying noise due to parallel imaging reconstruction, a new method has been implemented incorporating image data acquisition followed by a fast noise scan during which radio-frequency pulses, cardiac triggering and navigator gating are disabled. The performance of this method was evaluated in a phantom study where SNR measurements were compared with those of a reference standard (multiple repetitions). Subsequently, SNR of myocardium and posterior skeletal muscle was determined on in vivo human coronary MRA.Results: In a phantom, the SNR measured using the proposed method deviated less than 10.1% from the reference method for small geometry factors (<= 2). In vivo, the noise scan for a 10 min coronary MRA acquisition was acquired in 30 s. Higher signal and lower SNR, due to spatially varying noise, were found in myocardium compared with posterior skeletal muscle.Conclusion: SNR quantification based on a fast noise scan is a validated and easy-to-use method when applied to three-dimensional coronary MRA obtained with parallel imaging as long as the geometry factor remains low.
Resumo:
In coronary magnetic resonance angiography, a magnetization-preparation scheme for T2 -weighting (T2 Prep) is widely used to enhance contrast between the coronary blood-pool and the myocardium. This prepulse is commonly applied without spatial selection to minimize flow sensitivity, but the nonselective implementation results in a reduced magnetization of the in-flowing blood and a related penalty in signal-to-noise ratio. It is hypothesized that a spatially selective T2 Prep would leave the magnetization of blood outside the T2 Prep volume unaffected and thereby lower the signal-to-noise ratio penalty. To test this hypothesis, a spatially selective T2 Prep was implemented where the user could freely adjust angulation and position of the T2 Prep slab to avoid covering the ventricular blood-pool and saturating the in-flowing spins. A time gap of 150 ms was further added between the T2 Prep and other prepulses to allow for in-flow of a larger volume of unsaturated spins. Consistent with numerical simulation, the spatially selective T2 Prep increased in vivo human coronary artery signal-to-noise ratio (42.3 ± 2.9 vs. 31.4 ± 2.2, n = 22, P < 0.0001) and contrast-to-noise-ratio (18.6 ± 1.5 vs. 13.9 ± 1.2, P = 0.009) as compared to those of the nonselective T2 Prep. Additionally, a segmental analysis demonstrated that the spatially selective T2 Prep was most beneficial in proximal and mid segments where the in-flowing blood volume was largest compared to the distal segments. Magn Reson Med, 2013. © 2012 Wiley Periodicals, Inc.
Resumo:
Background-It remains uncertain whether acetylcysteine prevents contrast-induced acute kidney injury. Methods and Results-We randomly assigned 2308 patients undergoing an intravascular angiographic procedure with at least 1 risk factor for contrast-induced acute kidney injury (age >70 years, renal failure, diabetes mellitus, heart failure, or hypotension) to acetylcysteine 1200 mg or placebo. The study drugs were administered orally twice daily for 2 doses before and 2 doses after the procedure. The allocation was concealed (central Web-based randomization). All analysis followed the intention-to-treat principle. The incidence of contrast-induced acute kidney injury (primary end point) was 12.7% in the acetylcysteine group and 12.7% in the control group (relative risk, 1.00; 95% confidence interval, 0.81 to 1.25; P = 0.97). A combined end point of mortality or need for dialysis at 30 days was also similar in both groups (2.2% and 2.3%, respectively; hazard ratio, 0.97; 95% confidence interval, 0.56 to 1.69; P = 0.92). Consistent effects were observed in all subgroups analyzed, including those with renal impairment. Conclusions-In this large randomized trial, we found that acetylcysteine does not reduce the risk of contrast-induced acute kidney injury or other clinically relevant outcomes in at-risk patients undergoing coronary and peripheral vascular angiography.