AN ELECTROCHEMICAL MICROSENSOR FOR CHLORIDE


Autoria(s): DONG SJ; CHE GL
Data(s)

1991

Resumo

The potential-response of a microdisk electrode made with a chloride-doped polypyrrole (PPY) film on a carbon fibre (CF) has been examined. The effect of the polymerization conditions on the response characteristics is discussed. The optimum conditions for preparing the electrode are: cycling potential from +0.8 to +1.0 V in 0.1-0.2M pyrrole (Py) containing 0.1M LiCl, electropolymerization time 15-20 min. The electrode gives a Nernstian response of 56-58 mV/pCl and a detection limit of 3.6 x 10(-5)M chloride. It has the advantages of low resistance, short conditioning time and fast response. It has been used satisfactorily for detection of chloride in serum.

Identificador

http://ir.ciac.jl.cn/handle/322003/38535

http://www.irgrid.ac.cn/handle/1471x/163641

Idioma(s)

英语

Fonte

DONG SJ;CHE GL.AN ELECTROCHEMICAL MICROSENSOR FOR CHLORIDE,TALANTA,1991,38(1):111-114

Palavras-Chave #POLYPYRROLE
Tipo

期刊论文