Instability Analysis Of Torsional Mems/Nems Actuators Under Capillary Force


Autoria(s): 郭建刚; Zhou LJ; 赵亚溥
Data(s)

2009

Resumo

The static and dynamic instabilities of a torsional MEMS/NEMS actuator caused by capillary effects are studied, respectively. An instability number, eta, is defined, and the critical gap distance, g(cr), between the mainplate and the substrate is derived. According to the values of eta and g, the instability criteria of the actuator are presented. The dimensionless motion equation of the MEMS/NEMS torsional actuator is derived when it makes nonlinear oscillation under capillary force. The qualitative analysis of the nonlinear equation is made, and the phase portraits are presented on the phase plane. In addition, the bifurcation phenomena in the system are also analyzed. (C) 2008 Elsevier Inc. All rights reserved.

Identificador

http://dspace.imech.ac.cn/handle/311007/26618

http://www.irgrid.ac.cn/handle/1471x/8789

Idioma(s)

英语

Fonte

Journal Of Colloid And Interface Science, 2009, 331(2): 458-462

Palavras-Chave #Torsional Nems Actuator #Capillary Force #Instability #Bifurcation #Nanoscale Electrostatic Actuators #Van-Der-Waals #Casimir Force #Stability #Behavior #Plates
Tipo

期刊论文