1000 resultados para biologic width


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: The aim of the present study was to evaluate histometric changes around dental implants inserted at different levels in relation to the crestal bone, under different loading conditions.Material and methods: Thirty-six implants were inserted in the edentulous mandible of six mongrel dogs. Each implant was assigned to an experimental group according to the distance from the top of the implant to the crestal bone: Bone Level (at the crestal bone level), Minus 1 (1 mm below the crestal bone) or Minus 2 group (2 mm below the crestal bone). Each hemimandible was submitted to a loading protocol: conventional or immediate restoration. After 90 days, the animals were killed. Specimens were processed, and measurements were performed concerning the length of soft and hard peri-implant tissues. Data were analyzed using ANOVA and Student's t test (alpha=5%).Results: Among conventionally restored sites, the distance from the most coronal position of soft tissue margin (PSTM) and first bone-implant contact (fBIC) was greater for Minus 2 than for Bone Level and Minus 1 sites (P=0.03), but significant differences were not observed among immediately restored sites. Differences among groups were not observed concerning the PSTM, and the distance from the implant-abutment junction to fBIC. Greater amounts of lateral bone loss were observed for conventionally than for immediately restored sites (P=0.006).Conclusions: These findings suggest that the apical positioning of the top of the implant may not jeopardize the position of soft peri-implant tissues, and that immediate restoration can be beneficial to minimize lateral bone loss. Further studies are suggested to evaluate the clinical significance of these results in longer healing periods.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

\ The biologic width is an essential dental space that always needs to be maintained to ensure periodontal health in any dental prosthetic restorations. An iatrogenic partial fixed prosthesis constructed in lower posterior teeth predisposed the development of subgingival caries, which induced violation of the biologic width in involved teeth, resulting in an uncontrolled inflammatory process and periodontal tissue destruction. This clinical report describes a periodontal surgical technique to recover a violated biologic width in lower posterior teeth, by crown lengthening procedure associated with free gingival graft procedure, to ensure the possibility to place a modified partial fixed prosthesis in treated area. The procedure applied to recover the biologic width was crown lengthening with some modifications, associated with modified partial fixed prosthesis to achieve health in treated area. The modified techniques in both surgical and prosthetic procedures were applied to compensate the contraindications to recover biologic width by osteotomy in lower posterior teeth. The result, after 4 years under periodic control, seems to achieve the projected goal. Treating a dental diseased area is necessary to diagnose, eliminate, or control all etiologic factors involved in the process. When the traditional methods are not effective to recover destructed tissues, an alternative, compensatory, and adaptive procedure may be applied to restore the sequelae of the disease, applying a restorative method that respects the biology of involved tissues.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Among the factors that contribute to the papilla formation and crestal bone preservation between contiguous implants, this animal study clinically and radiographically evaluated the interimplant distances (IDs) of 2 and 3 mm and the placement depths of Morse cone connection implants restored with platform switch. Bilateral mandibular premolars of 6 dogs were extracted, and after 12 weeks, the implants were placed. Four experimental groups were constituted: subcrestally with ID of 2 mm (2 SCL) and 3 mm (3 SCL) and crestally with ID of 2 mm (2 CL) and 3 mm (3 CL). Metallic crowns were immediately installed with a distance of 3 mm between the contact point and the bone crest. Eight weeks later, clinical measurements were performed to evaluate papilla formation, and radiographic images were taken to analyze the crestal bone remodeling. The subcrestal groups achieved better levels of papillae formation when compared with the crestal groups, with a significant difference between the 3 SCL and 3 CL groups (P = .026). Radiographically, the crestal bone preservation was also better in the subcrestal groups, with statistically significant differences between the 2SCL and 2CL groups (P = .002) and between the 3SCL and 3CL groups (P = .008). With the present conditions, it could be concluded that subcrestal implant placement had a positive impact on papilla formation and crestal bone preservation, which could favor the esthetic of anterior regions. However, the IDs of 2 and 3 mm did not show significantly different results.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aim: To evaluate the effect of mismatching abutments on implants with a wider platform on the peri-implant hard tissue remodeling and the soft tissue dimensions.Material and methods: Mandibular premolars and first molars of six Labrador dogs were extracted bilaterally. After 3 months of healing, one tapered implant was installed on each side of the mandibular molar region with the implant shoulder placed at the level of the buccal alveolar bony crest. on the right side of the mandible, an abutment of reduced diameter in relation to the platform of the implant was used, creating a mismatch of 0.85 mm (test), whereas an abutment of the same diameter of the implant platform was affixed in the left side of the mandible (control). The flaps were sutured to allow a non-submerged healing. After 4 months, the animals were sacrificed and ground sections were obtained for histometric assessment.Results: All implants were completely osseo-integrated. Bone levels were superior at the test than at the control sites. However, statistically significant differences were found only at the buccal and proximal aspects. The soft tissue vertical dimension was higher at the control compared with the test sites. However, statistically significant differences were demonstrated only at the buccal aspects.Conclusions: A mismatch of 0.85 mm between the implant and the abutment yielded more coronal levels of bone-to-implant contact and a reduced height of the peri-implant soft tissue (biologic width), especially at the buccal aspect, if the implant shoulder was placed flush with the level of the buccal alveolar bony crest.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aim: To validate the platform switching concept at oral implants with respect to the preservation of the alveolar crestal bone levels in an animal model. Material & methods: Five minipigs received three implants each with a 0.25mm implant/ abutment mismatch and were placed flush (T(0)), 1 mm below (T(1)) and 1 mm above (T(+1)) the alveolar bony crest, and as a control, one conventionally restored implant placed at the bone level. The implants were randomly inserted flapless into the mandible. Four months after implant insertion, the animals were sacrificed, and undecalcified block sections were obtained and used for histological analyses. Results: The mean values for peri- implant bone resorption were 1.09 +/- 0.59mm (Control), 0.51 (+/- 0.27 mm, T(0)), 0.50 (+/- 0.46 mm, T(1)) and 1.30 (+/- 0.21 mm, T (+1)), respectively. Statistically significant differences (P< 0.05) were found among the test (T(0), T(-1)) and the control sites. Control implants presented an average biologic width length of 3.20mm (+/- 0.33), with a connective tissue adaptation compartment of 1.29mm (+/- 0.53) and an epithelial attachment of 1.91 mm (+/- 0.71). T(0), T(1) and T(+1) implants presented with a mean biologic width of 1.97mm (+/- 1.20), 2.70 mm (+/- 1.36) and 2.84mm (+/- 0.90), respectively, with a connective tissue adaptation compartment of 1.21mm (+/- 0.97), 1.21 mm (+/- 0.65) and 1.50 mm (+/- 0.70) and an epithelial attachment of 0.84 mm (+/- 0.93), 1.66 mm (+/- 0.88) and 1.35 mm (+/- 0.44), respectively. Differences between the configurations were mainly associated with the length of the epithelial attachment. The epithelial attachment was significantly longer in the C sites than in T(0) (P = 0.014). However, no other differences between configurations were detected. Conclusion: If the implants are positioned at the level of the alveolar bony crest, the platform switching concept may have a minor impact on the length of the epithelial attachment (0.84 vs. 1.91 mm), while the connective tissue adaptation compartment remains relatively unaffected. Moreover, platform switching resulted in less resorption of the alveolar crest (0.58 mm).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: This prospective randomized matched-pair controlled trial aimed to evaluate marginal bone levels and soft tissue alterations at implants restored according to the platform-switching concept with a new inward-inclined platform and compare them with external-hexagon implants. Materials and Methods: Traditional external-hexagon (control group) implants and inward-inclined platform implants (test group), all with the same implant body geometry and 13 mm in length, were inserted in a standardized manner in the posterior maxillae of 40 patients. Radiographic bone levels were measured by two independent examiners after 6, 12, and 18 months of prosthetic loading. Buccal soft tissue height was measured at the time of abutment connection and 18 months later. Results: After 18 months of loading, all 80 implants were clinically osseointegrated in the 40 participating patients. Radiographic evaluation showed mean bone losses of 0.5 +/- 0.1 mm (range, 0.3 to 0.7 mm) and 1.6 +/- 0.3 mm (range, 1.1 to 2.2 mm) for test and control implants, respectively. Soft tissue height showed a significant mean decrease of 2.4 mm in the control group, compared to 0.6 mm around the test implants. Conclusions: After 18 months, significantly greater bone loss was observed at implants restored according to the conventional external-hexagon protocol compared to the platform-switching concept. In addition, decreased soft tissue height was associated with the external-hexagon implants versus the platform-switched implants. INT J ORAL MAXILLOFAC IMPLANTS 2012;27:927-934.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE To evaluate the biologic width dimensions around implants with nonmatching implant-abutment diameters. MATERIALS AND METHODS Five canines had their mandibular premolars and first molars removed bilaterally and replaced with 12 implants that had nonmatching implant-abutment diameters. On one side, six implants were placed in a submerged surgical approach, and the other side utilized a nonsubmerged approach. Two of the implants on each side were placed either 1 mm above, even with, or 1 mm below the alveolar crest. Two months later, gold crowns were attached, and the dogs were sacrificed 6 months postloading. Block sections were processed for histologic and histomorphometric analyses. RESULTS The bone level, connective tissue length, epithelial dimension, and biologic width were not significantly different when the implants were initially placed in a submerged or nonsubmerged surgical approach. The bone level was significantly different around implants placed 1 mm above the crest compared to implants placed even with or 1 mm below the alveolar crest. The connective tissue dimension was not different for any implant level placement. The epithelial dimension and biologic width were significantly greater for implants placed 1 mm below the alveolar crest compared to implants placed even with or 1 mm above the alveolar crest. For five of six implant placements, connective tissue covered the implant/abutment interface. CONCLUSIONS This study reveals a fundamental change in the biologic response to implants with nonmatching implant-abutment diameters. Unlike implants with matching implant-abutment diameters, the connective tissue extended coronally past the interface (microgap). This morphologic tissue alteration represents a significant change in the biologic reaction to implant-abutment interfaces and suggests that marginal inflammation is eliminated or greatly reduced in these implant designs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introdução: O alongamento coronário é um procedimento que pode envolver, ou não, técnicas cirúrgicas, e que tem como principal objetivo aumentar o tamanho da coroa clínica, assim como devolver a estética, a forma e a função às arcadas dentárias. Este procedimento realiza-se, ou por motivos estéticos ou motivos restauradores. Ultimamente, os motivos estéticos têm vindo a ganhar importância e são eles que, muitas da vezes, levam os pacientes às consultas de medicina dentária. O sorriso gengival é um desses motivos, e pode ser causado, entre outras razões por, uma erupção passiva alterada ou/e um excesso vertical maxilar. Estas são as etiologias que serão descritas neste trabalho. O aumento coronário realiza-se, também, quando há a necessidade de reabilitar um dente, quer seja com resinas compostas ou com coroas. Este, deve sempre respeitar os limites biológicos do periodonto, nomeadamente o espaço biológico. A invasão deste espaço pode por em risco a manutenção da saúde do periodonto e a viabilidade do tratamento a longo prazo, por isto, preconiza-se que deve ser deixado um espaço de 3mm, desde a crista óssea até a margem restauradora. As técnicas de alongamento coronário enumeradas e definidas ao longo desta tese são: a gengivectomia, o retalho apicalmente posicionado e a erupção dentária forçada. Cada uma delas possui as suas indicações e contra-inidcaçoes. A gengivectomia é realizada quando não há necessidade de recontorno ósseo, pelo contrário, quando essa necessidade existe opta-se pelo retalho apicalmente posicionado. A erupção forçada é uma alternativa ao alongamento cirúrgico e aplica-se, normalmente a dentes não restauráveis mas com estrutura dentária sã abaixo do da crista óssea. Um ótimo diagnóstico é o essencial para a escolha da técnica de aumento coronário que melhor se adequa a cada caso. Objetivo: O objetivo desta revisão bibliográfica tem por base a pesquisa das técnicas de alongamento coronário, começando por perceber a anatomia do periodonto, as alterações que nele acontecem antes e depois dos procedimentos de alongamento coronário, a descrição e a comparação dos mesmos. Materiais e métodos: Para a realização desta revisão foram utilizados os principais motores de busca de dados científicos como a PubMed, B-on, Medline, Scielo, Google Académico e ainda o repositório on-line da Universidade Fernando Pessoa. Foram utilizadas as seguintes palavras chaves: “altered passive eruption”, “gingivectomy”, “gingivoplasty”, “apically repositioned flap”, “surgical crown lengthening”, “biologic width”, “mucogengival junction”, “forced eruption”, “prostethic dentistry”, “gummy smile”, resultando num pesquisa de 45 artigos e duas obras literarátias de interesse. Conclusões: Foi possível concluir que existem varias técnicas de alongamento coronário, cada uma adequada a cada caso e verificou-se que existem vários motivos pelo qual se realiza essa técnica.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introdução: A reabilitação com implantes nas últimas décadas tem evoluído tendo em vista a obtenção de melhores resultados ao nível mecânico/funcional, mas também a nível estético. A relação coronal dos implantes com crista óssea é um dos pontos que tem sido estudado. Objectivo: Realizar uma revisão sobre a relação coronal dos implantes com a crista óssea, com objectivo de responder à seguinte questão “A posição sub-crestal dos implantes em relação à crista óssea é vantajosa?”. Para tal vão ser estudados alguns dos factores que podem influenciar esta decisão. Metodologia: Realizou-se pesquisa bibliográfica recorrendo às bases de dados da “MEDLINE/Pubmed”, “SciELO”, “Science Direct”, “B-on”, “Google Academic” e repositórios de várias universidades portuguesas e estrangeiras, com as palavras-chave: “Bone Cells” ”Bone remodeling”, “Bone Crest”, “Osseointegration”, “Implant Placement”, “Biologic Width” e “Platform Switching”,”Implant Placement Depth” e “Morse Cone”, tendo sido estas associadas entre si. Também foi realizada pesquisa manual em livros dos vários temas estudados. Conclusão: A colocação de implantes ao nível sub-crestal ainda apresenta alguma controvérsia, mas obedecendo a alguns factores, como a utilização de um implante e pilar específicos, pode tornar- se algo muito vantajoso numa perspectiva futura.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Research has shown that road lane width impacts on driver behaviour. This literature review provides guidelines to assist in the design, construction and retrofitting of urban roads to accommodate road users' safety requirements. It focuses on the impacts of lane widths on cyclists and motor vehicle safety behaviour. The literature review commenced with a search of library databases. Peer reviewed articles and road authority (local, state and national) reports were reviewed. The majority of studies investigating the effects of lane width on driver behaviour were simulator based, while research into cycling safety involved data collected from actual traffic environments. Results show that marked road lane width influences perceived task difficulty, risk perception and possibly speed choice. The positioning of cyclists in traffic lanes is influenced by the presence of on-road cycling facilities and the total roadway width. The lateral displacement between bicycle and vehicle is smallest when a bicycle facility is present. Lower, or reduced, vehicle speeds play a significant role in improving bicyclist and pedestrian safety. It is also shown that if road lane widths in urban areas were reduced, to a functional width that was less than the current guidelines of 3.5m, it could result in a safer road environment for all road users.