904 resultados para Tratamento de águas residuais


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, it is intended to expose the state of the art relating the use of microalgae in wastewater treatment. Nitrogen and phosphorous removal with microalgae is a common process. Biosorption by microlgae is an alternative to traditional treatment processes of metal ions removal. Neste trabalho pretende-se expor, de uma forma simples, o estado da arte no que diz respeito à utilização de microalgas para tratamento de águas residuais. São abordadas, com algum detalhe, as utilizações das microalgas para remoção de nutrientes e de metais pesadas de águas residuais.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação de mest., Engenharia do Ambiente, Faculdade de Ciências do Mar e do Ambiente, Universidade do Algarve, 2008

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação de mest., Engenharia do Ambiente, Faculdade de Ciências do Mar e do Ambiente, Univ. do Algarve, 2009

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Trabalho de Dissertação de Natureza Científica para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização em Hidráulica

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Os odores emitidos por estações de tratamento de águas residuais urbanas (ETAR) representam um problema potencial para a sua integração urbanística e ambiental. Por outro lado, os odores representam igualmente um perigo potencial para a saúde dos trabalhadores das ETAR, para a conservação das infraestruturas e para a eficiência de tratamento. Deste modo, o conhecimento sobre a sua ocorrência, contenção e tratamento é fundamental para a concepção, projecto e exploração das infraestruturas de saneamento. Com o objectivo de resumir e sistematizar a informação sobre o estado da arte relativo aos odores em ETAR, foi realizada uma revisão detalhada sobre os vários aspectos associados a este problema, nomeadamente formação e controlo de odores. De modo idêntico com o objectivo de procurar contribuir para a caracterização da situação em Portugal foram identificadas as principais ETAR existentes com desodorização, tendo sido organizados inquéritos e visitas a todas elas por forma a apurar a informação considerada mais relevante, nomeadamente no que diz respeito à tecnologia utilizada, bem como aspectos particulares de exploração e custos envolvidos. As principais conclusões do estudo efectuado incluem por um lado a importânica da concepção dos sistemas de contenção e ventilação como partes essenciais no controlo dos odores e, por outro, a baixa representatividade dos custos de investimento e de exploração do controlo de odores no total de uma ETAR. A tecnologia de tratamento mais aplicada é a absorção e oxidação química, seguida pela biofiltração e por adsorção em carvão activado e, aparentemente, a selecção das tecnologias não está relacionada nem com a dimensão da ETAR nem com o caudal de ar a tratar. Por outro lado, a monitorização dos odores e dos compostos odoríficos é poucas vezes efectuada, o que limita, de um modo muito significativo, a correcta avaliação dos processos de tratamento.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Esta dissertação descreve o trabalho desenvolvido ao longo de um ano e um mês desde a pesquisa teórica até à prática experimental no âmbito da unidade curricular de Dissertação/estágio do Mestrado em Engenharia Química, no ramo Tecnologias em Proteção Ambiental. O tema desta dissertação consiste na avaliação do funcionamento de duas estações de tratamento de águas residuais (ETAR) do interior do município de Vila Nova de Gaia no que diz respeito ao possível aumento da resistência a antibióticos na ETAR de Febros e na ETAR de Lever. Os testes de sensibilidade a antibióticos (TSA) foram executados para ambas as ETAR, sendo as amostras de água recolhidas na entrada e na saída dos reatores biológicos (tratamento secundário). Além disso, foram realizados testes de avaliação da eficiência de desinfeção por radiação ultravioleta (UV) relativamente à Escherichia coli (E. coli) na ETAR de Lever. Os antibióticos selecionados para a realização deste trabalho foram a Eritromicina, a Azitromicina, a Claritromicina, a Ofloxacina, a Ciprofloxacina, o Sulfametoxazol, o Trimetoprim e o Metronidazol. Esta seleção baseou-se no facto de estes serem alguns dos antibióticos mais consumidos e mais persistentes no meio ambiente. A bactéria E. coli (isolada a partir de amostras das águas residuais estudadas) foi escolhida para a realização deste estudo uma vez que está sempre presente nas águas residuais domésticas e está associada a fenómenos de multirresistência a antibióticos. Os testes de TSA foram realizados seguindo a metodologia de difusão por discos. No período do estudo (Março a Junho de 2015) identificaram-se situações quer de aumento de resistência quer de aumento de sensibilidade aos antibióticos testados. As situações mais graves de aumento de resistência, a que corresponderam a halos nulos, verificaram-se para os antibióticos Claritromicina, Trimetoprim e Metronidazol, ocorrendo com maior frequência para os dois últimos, que aliás são fármacos que são administrados em simultâneo. Os períodos mais problemáticos em termos de aumento das resistências foram ligeiramente diferentes nas duas ETAR. No caso da ETAR de Febros correspondeu ao mês Abril e na ETAR de Lever ocorreu entre o final de Abril e o início de Maio. Considera-se que estes períodos poderão coincidir com um aumento do consumo destes fármacos devido à sua utilização no combate a infeções respiratórias muito comuns nesta altura do ano. Não se observou qualquer sensibilidade da E. coli para o Metronidazol porque é um antibiótico com indicação para algumas bactérias anaeróbias, fungos e giardia, e que à partida não tem capacidade para eliminar a E. coli. A eficiência da desinfeção na ETAR de Lever relativamente à remoção de E. coli foi satisfatória. Sendo de salientar a importância da manutenção, no que se refere à identificação de possíveis avarias nas lâmpadas e correspondente limpeza. Os resultados deste trabalho provam a existência de estirpes da bactéria E. coli resistentes a alguns dos antibióticos estudados, o que reforça a importância da desinfeção no tratamento de águas residuais domésticas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O presente relatório é o corolário do Estágio Curricular que a autora efetuou, durante o segundo semestre do ano letivo de 2014/2015 na SBS – Engenharia Civil, Hidráulica e Ambiente, Lda. Nesta empresa a autora foi integrada na equipa técnica que elaborou um Projeto de Execução para uma Estação de Tratamento de Águas Residuais que irá ser construída em Montemor-o-Novo, tendo-lhe sido atribuídas as seguintes tarefas principais: i) estudo de ferramentas de dimensionamento de ETAR; e ii) estudo dos processos de tratamento de águas residuais a instalar. O tratamento de águas residuais não é matéria que conste do atual Plano de Estudos do Mestrado em Engenharia Civil do ISEP. Este facto, associado à premente necessidade de dar resposta às expectativas da Entidade Acolhedora, obrigou a autora a um esforço de aprendizagem significativo. Nesta fase foi executada uma aprofundada pesquisa bibliográfica que permitiu à autora obter o nível de conhecimentos teóricos necessário para a plena integração na Equipa de Projeto. Já integrada na Equipa de Projeto o primeiro trabalho desenvolvido pela autora foi a análise detalhada do Caderno de Encargos e da respetiva Nota Técnica. Seguidamente a autora participou em todas as fases do Projeto tendo, por isso, colaborado na análise do Estudo Geotécnico, no dimensionamento dos órgãos da ETAR, no cálculo do perfil hidráulico, na definição de formas (plantas e cortes) dos órgãos, na elaboração da Lista de Equipamentos e do Mapa de Quantidades e, por último, na elaboração da Memória Descritiva e Justificativa do Processo de Tratamento e Equipamentos. O Caso Prático incluído no presente documento é, em larga medida, o corolário do processo de aprendizagem de que a autora beneficiou no decorrer do Estágio Curricular. Grande parte das tarefas que a autora executou ao longo da elaboração do projeto relacionaram-se com o dimensionamento dos órgãos da ETAR e com os respetivos cálculos hidráulicos. Os conhecimentos teórico-práticos desta forma adquiridos foram reunidos num conjunto de ferramentas, maioritariamente folhas de cálculo, que se verificou serem úteis nos processos de dimensionamento e de teste de soluções alternativas. É parte integrante deste relatório um capítulo no qual é feita uma detalhada apresentação dos conceitos teóricos subjacentes ao Projeto de ETAR. Este capítulo reflete o estudo que a autora teve necessidade de efetuar antes de se sentir capaz de integrar a Equipa de Projeto.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A poluição das águas por hidrocarbonetos pode originar grandes problemas associados a contaminantes orgânicos e inorgânicos uma vez que os combustíveis fósseis, como o petróleo e os seus derivados, são matérias-primas para a produção de energia na maioria dos processos industriais actuais. Os hidrocarbonetos reduzem a oxigenação e a penetração da luz natural nos cursos de água, devido à formação de um filme insolúvel na superfície, produzindo efeitos nocivos na fauna e flora aquática. Neste trabalho é apresentada uma síntese das diferentes tecnologias disponíveis e habitualmente usadas para o tratamento de efluentes de Refinarias de petróleo e disponibilizam-se resultados da eficiência de remoção de vários poluentes ao longo do processo de tratamento dos efluentes gerados, resumindo-se as principais dificuldades com que o tratamento deste tipo de efluentes se depara.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present work had as objective to apply an experimental planning aiming at to improve the efficiency of separation of a new type of mixer-settler applied to treat waste water contaminated with oil. An unity in scale of laboratory, was installed in the Post-graduation Program of Chemical Engineering of UFRN. It was constructed in partnership with Petrobras S.A. This called device Misturador-Decantador a Inversão de Fases (MDIF) , possess features of conventional mixer-settler and spray column type. The equipment is composed of three main parts: mixing chamber; chamber of decantation and chamber of separation. The efficiency of separation is evaluated analyzing the oil concentrations in water in the feed and the output of the device. For the analysis one used the gravimetric method of oil and greases analysis (TOG). The system in study is a water of formation emulsified with oil. The used extractant is a mixture of Turpentine spirit hydro-carbons, supplied for Petrobras. It was applied, for otimization of the efficiency of separation of the equipment, an experimental planning of the composite central type, having as factorial portion fractionary factorial planning 2 5-2, with the magnifying of the type star and five replications in the central point. In this work, the following independents variables were studied: contents of oil in the feed of the device; volumetric ratio (O/A); total flowrate ; agitation in the mixing chamber and height of the organic bed. Minimum and maximum limits for the studied variables had been fixed according previous works. The analysis of variance for the equation of the empirical model, revealed statistically significant and useful results for predictions ends. The variance analysis also presented the distribution of the error as a normal distribution and was observed that as the dispersions do not depend on the levels of the factors, the independence assumption can be verified. The variation around the average is explained by 98.98%, or either, equal to the maximum value, being the smoothing of the model in relation to the experimental points of 0,98981. The results present a strong interaction between the variable oil contents in the feed and agitation in the mixing chamber, having great and positive influence in the separation efficiency. Another variable that presented a great positive influence was the height of the organic bed. The best results of separation efficiency had been obtained for high flowrates when associates the high oil concentrations and high agitation. The results of the present work had shown excellent agreement with the results carried out through previous works with the mixer-settler of phase inversion

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O abastecimento de água e a drenagem de águas residuais são funções essenciais num aquartelamento de campanha. Estas funções influenciam diretamente a manutenção da prontidão e eficácia de uma força militar destacada para uma operação e consequente sucesso da mesma. O consumo de água em campanha pode ser variável consoante o efetivo e as características da força destacada, clima, ambiente operacional e o tempo de permanência previsto para a operação. Apresenta-se nesta dissertação de mestrado uma metodologia de planeamento do sistema de abastecimento de água, do sistema de drenagem e dos órgãos de tratamento de águas residuais, aplicáveis a situações de campanha. Considerando o conteúdo desta dissertação foi realizado um caso de estudo relacionado com o aquartelamento de campanha construído no âmbito da operação militar da UNIFIL, no Líbano. Apresenta-se ainda o enquadramento geográfico do país e a análise da sua situação relativamente ao saneamento, informações essas que podem ser muito importantes na decisão da melhor localização para o aquartelamento. Na análise do caso de estudo procedeu-se ao dimensionamento das redes de abastecimento de água, de drenagem de águas residuais e dos órgãos de tratamento adequados. Foram sugeridas algumas alterações no traçado, diâmetros da rede de drenagem de águas residuais, assim como na geometria da fossa sética existente, pois encontrava-se sobredimensionada. Devido à ausência de tratamento do efluente dela proveniente, o que é nocivo a nível ambiental, sugeriu-se ainda a aplicação de um aterro filtrante como órgão de tratamento complementar.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As implicações ambientais dos plásticos convencionais, produzidos através de combustíveis fósseis, não permitem a sua utilização de forma sustentável pela sociedade devido aos seus problemas de degradabilidade e à sua dependência de matérias-primas não renováveis. Surgem então os polihidroxialcanoatos (PHA) como uma alternativa ambientalmente sustentável, já que conseguem reproduzir grande parte das aplicações dos plásticos ditos normais, tendo as grandes vantagens de serem biodegradáveis e produzidos a partir de uma fonte de carbono renovável. Mais recentemente, de forma a tornar a produção do PHA mais sustentável, tem-se desenvolvido o conceito de associar a produção destes polímeros ao tratamento de efluentes líquidos através do processo de lamas ativadas. Apesar destas vantagens todo o processo que envolve a produção do PHA é ainda dispendioso. Esta dissertação insere-se na estratégia de tentar minorar esses custos. Uma das formas de o fazer será na otimização de técnicas de quantificação do PHA em culturas mistas. Neste trabalho o principal objetivo reside na avaliação da capacidade da metodologia de análise de imagem, acoplada a microscopia de fluorescência, como método de quantificação de PHA. Pretende-se também explorar a produção de PHA a partir da simulação de um sistema de tratamento de águas residuais implementado num reator descontínuo sequencial (SBR) em regimes cíclicos de feast/famine, aliando assim a função de tratamento de efluentes líquidos com a produção de um produto de valor acrescentado como é o PHA. Deste modo, foi montada uma instalação com um sistema de lamas ativadas num SBR cujo principal objetivo era produzir PHA. Este objetivo de produzir PHA através do regime de alimentação dinâmica aeróbia com uma alimentação com acetato como fonte de carbono, e sem controlo do pH foi conseguido, atingindo-se um máximo de concentração mássica de 0,37 mg PHA/mg SST e de concentração volumétrica de 1785 mg PHA/L. Em relação à capacidade de tratamento, comprovou-se a adequabilidade do sistema utilizado para a remoção da carga orgânica devido a uma elevada captação de nutrientes do afluente pela biomassa. Foram encontradas algumas limitações na metodologia de análise de imagem ao nível da transformação da bidimensionalidade da área projetada dos grânulos de PHA nas imagens para a sua tridimensionalidade real, na gama de concentração de PHA na qual a metodologia é válida e na amostragem relativamente curta. Contudo, foi possível comprovar a potencialidade deste método obtendo-se um R2 de 0,80 para o modelo de previsão da concentração mássica de PHA. Deste modo, pode-se concluir que esta é uma metodologia promissora para quantificar PHA em amostras de licor misto.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A modelação matemática de Estações de Tratamento de Águas Residuais (ETAR) tem sido uma ferramenta de enorme utilidade nas fases de projeto e de exploração destas estruturas de tratamento. O presente estudo teve por objetivo principal construir um modelo matemático da ETAR de Bragança, em particular do seu tratamento biológico de lamas ativadas, com vista a avaliar, compreender e otimizar o seu desempenho. A construção do modelo foi efetuada com recurso ao ambiente de simulação WRc STOAT 5.0. O processo de lamas ativadas foi descrito pelo modelo de referência ASAL3. O modelo construído foi calibrado e validado com base em dados experimentais de 2015, obtidos no âmbito do programa de controlo analítico da ETAR. O modelo foi ainda utilizado para avaliar a qualidade do efluente em resposta a alterações do caudal e composição do afluente, a alterações de condições operacionais e a outras alternativas de tratamento. O modelo mostrou-se bastante adequado na descrição da evolução mensal da qualidade do efluente final da ETAR relativamente aos parâmetros Sólidos Suspensos Totais (SST) e Carência Bioquímica de Oxigénio (CBO5), embora apresente uma tendência para os subestimar em 1,5 e 3,5 mg/L, respetivamente. Em relação ao azoto total, os valores simulados aproximaram-se dos valores reais, quando se aumentaram as taxas de recirculação interna para 400%, um fator de cerca de 4 vezes superior. Os resultados do modelo e dos cenários mostram e reforçam o bom desempenho e a operação otimizada da ETAR em relação a remoção de SST e CBO5. Em relação ao azoto total, a ETAR não assegura de forma sistemática uma eficiência elevada, mas apresenta um bom desempenho, face ao que o modelo consegue explicar para as mesmas condições operacionais. Através do estudo de cenários procurou-se encontrar alternativas de tratamento eficientes e viáveis de remoção de azoto total, mas não se identificaram soluções que assegurassem decargas de azoto abaixo dos limites legais. Os melhores resultados que se alcançaram para a remoção deste contaminante estão associados ao aumento das taxas de recirculação interna do sistema pré-anóxico existente e a uma configuração do tipo Bardenpho de quatro estágios com alimentação distribuída, em proporções iguais, pelos dois estágios anóxicos. Outras soluções que envolvam tecnologias distintas podem e devem ser equacionadas em projetos futuros que visem a melhoria de eficiência de remoção de azoto da ETAR.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Numa era de globalização da economia, a par de uma crise económica mundial, do aumento da competitividade, da concorrência e expectativas dos consumidores, torna-se fundamental e indispensável para uma empresa avaliar o desempenho das suas áreas de negócio. Essa avaliação assume maior proporção e importância quando, um dos principais objectivos da empresa é a aposta na internacionalização e no crescimento sustentado de uma área de negócio muito específica, como a do tratamento das águas residuais industriais. O presente projecto visa a realização de uma auditoria operacional à área de negócio do tratamento das águas residuais industriais, tendo em vista examinar se o seu contributo é eficaz na Empresa VentilAQUA, SA. Para examinar essa eficácia foram definidos dois objectivos principais da auditoria. O primeiro consiste em apreciar se a definição dos objectivos operacionais para a área de negócio examinada, foram definidos de forma clara, alinhados com a estratégia, com a gestão do risco e se são adequados aos recursos. O segundo incide sobre a análise do contributo de cada mercado - interno, comunitário e extra-comunitário - para os resultados económico-financeiros da empresa. Para a realização do presente trabalho foi seguida uma metodologia qualitativa, assente no método do estudo de caso. Seguindo a metodologia, os procedimentos e atendendo aos critérios da auditoria definidos e, tendo em conta as conclusões alcançadas e descritas na parte final deste projecto, conclui-se sobre a eficácia da área de negócio do tratamento das águas residuais industriais na Empresa VentilAQUA, SA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação de Mestrado, Engenharia do Ambiente, Faculdade de Ciências e Tecnologia, Universidade do Algarve, 2015