662 resultados para Transesophageal Echocardiography


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The authors present the case of an 81-year-old patient with severe aortic stenosis who experienced left ventricular embolization of an aortic bioprosthesis during transapical aortic valve implantation. The authors discuss reasons for prosthesis embolization and reinforce the attention to technical details and the widespread use of multimodality imaging techniques. In this context, transesophageal echocardiography appears indispensable in the detection and management of procedure-related complications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Compare changes in P-wave amplitude of the intra-atrial electrocardiogram (ECG) and its corresponding transesophageal echocardiography (TEE)-controlled position to verify the exact localization of a central venous catheter (CVC) tip. DESIGN: A prospective study. SETTING: University, single-institutional setting. PARTICIPANTS: Two hundred patients undergoing elective cardiac surgery. INTERVENTIONS: CVC placement via the right internal jugular vein with ECG control using the guidewire technique and TEE control in 4 different phases: phase 1: CVC placement with normalized P wave and measurement of distance from the crista terminalis to the CVC tip; phase 2: TEE-controlled placement of the CVC tip; parallel to the superior vena cava (SVC) and measurements of P-wave amplitude; phase 3: influence of head positioning on CVC migration; and phase 4: evaluation of positioning of the CVC postoperatively using a chest x-ray. MEASUREMENTS AND MAIN RESULTS: The CVC tip could only be visualized in 67 patients on TEE with a normalized P wave. In 198 patients with the CVC parallel to the SVC wall controlled by TEE (phase 2), an elevated P wave was observed. Different head movements led to no significant migration of the CVC (phase 3). On a postoperative chest-x-ray, the CVC position was correct in 87.6% (phase 4). CONCLUSION: The study suggests that the position of the CVC tip is located parallel to the SVC and 1.5 cm above the crista terminalis if the P wave starts to decrease during withdrawal of the catheter. The authors recommend that ECG control as per their study should be routinely used for placement of central venous catheters via the right internal jugular vein.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Patent foramen ovale (PFO) is associated with cryptogenic stroke (CS), although the pathogenicity of a discovered PFO in the setting of CS is typically unclear. Transesophageal echocardiography features such as PFO size, associated hypermobile septum, and presence of a right-to-left shunt at rest have all been proposed as markers of risk. The association of these transesophageal echocardiography features with other markers of pathogenicity has not been examined. METHODS AND RESULTS We used a recently derived score based on clinical and neuroimaging features to stratify patients with PFO and CS by the probability that their stroke is PFO-attributable. We examined whether high-risk transesophageal echocardiography features are seen more frequently in patients more likely to have had a PFO-attributable stroke (n=637) compared with those less likely to have a PFO-attributable stroke (n=657). Large physiologic shunt size was not more frequently seen among those with probable PFO-attributable strokes (odds ratio [OR], 0.92; P=0.53). The presence of neither a hypermobile septum nor a right-to-left shunt at rest was detected more often in those with a probable PFO-attributable stroke (OR, 0.80; P=0.45; OR, 1.15; P=0.11, respectively). CONCLUSIONS We found no evidence that the proposed transesophageal echocardiography risk markers of large PFO size, hypermobile septum, and presence of right-to-left shunt at rest are associated with clinical features suggesting that a CS is PFO-attributable. Additional tools to describe PFOs may be useful in helping to determine whether an observed PFO is incidental or pathogenically related to CS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION Hemodynamic management in intensive care patients guided by blood pressure and flow measurements often do not sufficiently reveal common hemodynamic problems. Trans-esophageal echocardiography (TEE) allows for direct measurement of cardiac volumes and function. A new miniaturized probe for TEE (mTEE) potentially provides a rapid and simplified approach to monitor cardiac function. The aim of the study was to assess the feasibility of hemodynamic monitoring using mTEE in critically ill patients after a brief operator training period. METHODS In the context of the introduction of mTEE in a large ICU, 14 ICU staff specialists with no previous TEE experience received six hours of training as mTEE operators. The feasibility of mTEE and the quality of the obtained hemodynamic information were assessed. Three standard views were acquired in hemodynamically unstable patients: 1) for assessment of left ventricular function (LV) fractional area change (FAC) was obtained from a trans-gastric mid-esophageal short axis view, 2) right ventricular (RV) size was obtained from mid-esophageal four chamber view, and 3) superior vena cava collapsibility for detection of hypovolemia was assessed from mid-esophageal ascending aortic short axis view. Off-line blinded assessment by an expert cardiologist was considered as a reference. Inter-rater agreement was assessed using Chi-square tests or correlation analysis as appropriate. RESULTS In 55 patients, 148 mTEE examinations were performed. Acquisition of loops in sufficient quality was possible in 110 examinations for trans-gastric mid-esophageal short axis, 118 examinations for mid-esophageal four chamber and 125 examinations for mid-esophageal ascending aortic short axis view. Inter-rater agreement (Kappa) between ICU mTEE operators and the reference was 0.62 for estimates of LV function, 0.65 for RV dilatation, 0.76 for hypovolemia and 0.77 for occurrence of pericardial effusion (all P < 0.0001). There was a significant correlation between the FAC measured by ICU operators and the reference (r = 0.794, P (one-tailed) < 0.0001). CONCLUSIONS Echocardiographic examinations using mTEE after brief bed-side training were feasible and of sufficient quality in a majority of examined ICU patients with good inter-rater reliability between mTEE operators and an expert cardiologist. Further studies are required to assess the impact of hemodynamic monitoring by mTEE on relevant patient outcomes.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

AIMS: In pressure overload left ventricular (LV) hypertrophy, gender-related differences in global LV systolic function have been previously reported. The goal of this study was to determine regional systolic function of the left ventricle in male and female patients with hypertensive heart disease. METHODS AND RESULTS: Regional LV function was analyzed from multiplane transesophageal echocardiography with three-dimensional (3D) reconstruction of the left ventricle. In 24 patients (13 males and 11 females), four parallel (2 basal and 2 apical) equidistant short axis cross-sections from base to apex were obtained from the reconstructed LV. In each short axis 24 wall-thickness measurements were carried out at 15 degrees intervals at end-diastole and end-systole. Thus, a total of 192 measurements were obtained in each patient. Wall thickening was calculated as difference of end-diastolic and end-systolic wall thickness, and fractional thickening as thickening divided by end-diastolic thickness. Fractional thickening and wall stress were inversely related to end-diastolic wall thickness in both, males and females. Females showed less LV systolic function when compared to males (p<0.001). However, when corrected for wall stress, which was higher in females, there was no gender difference in systolic function. CONCLUSION: There are regional differences in LV systolic function in females and males which are directly related to differences in wall stress. Thus, gender-related differences in LV regional function are load-dependent and not due to structural differences.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVES: We sought to assess the safety and clinical efficacy of patent foramen ovale (PFO) closure under fluoroscopic guidance only, without intraprocedural echocardiography. BACKGROUND: Percutaneous PFO closure has been shown to be safe and feasible using several devices. It is generally performed using simultaneously fluoroscopic and transesophageal or intracardiac echocardiographic guidance. Transesophageal echocardiography requires sedation or general anesthesia and intubation to avoid aspiration. Intracardiac echocardiography is costly and has inherent risks. Both lengthen the procedure. The Amplatzer PFO Occluder (AGA Medical Corporation, Golden Valley, Minnesota) can be safely implanted without echocardiographic guidance. METHODS: A total of 620 patients (51 +/- 12 years; 66% male) underwent PFO closure using the Amplatzer PFO Occluder for secondary prevention of presumed paradoxical embolism. Based on size and mobility of the PFO and the interatrial septum, an 18-mm device was used in 50 patients, a 25-mm device in 492, and a 35-mm device in 78. RESULTS: All procedures were successful, with 5 procedural complications (0.8%): 4 arteriovenous fistulae requiring elective surgical correction, and 1 transient ischemic attack. Contrast transesophageal echocardiography at 6 months showed complete closure in 91% of patients, whereas a minimal, moderate, or large residual shunt persisted in 6%, 2%, and 1%, respectively. During a mean follow-up period of 3.0 +/- 1.9 years (median: 2.6 years; total patient-years: 1,871), 5 ischemic strokes, 8 transient ischemic attacks, and no peripheral emboli were reported. Freedom from recurrent ischemic stroke, transient ischemic attack, or peripheral embolism was 99% at 1 year, 99% at 2 years, and 97% at 5 years. CONCLUSIONS: The Amplatzer PFO Occluder affords excellent safety and long-term clinical efficacy of percutaneous PFO closure without intraprocedural echocardiography.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Transcatheter closure of patent foramen ovale (PFO) has rapidly evolved as the preferred management strategy for the prevention of recurrent cerebrovascular events in patients with cryptogenic stroke and presumed paradoxical embolus. There is limited outcome data in patients treated with this therapy particularly for the newer devices. METHODS: Data from medical records, catheter, and echocardiography databases on 70 PFO procedures performed was collected prospectively. RESULTS: The cohort consisted of 70 patients (mean age 43.6 years, range 19 to 77 years), of whom 51% were male. The indications for closure were cryptogenic cerebrovascular accident (CVA) or transient ischemic attack (TIA) in 64 (91%) and peripheral emboli in two (2.8%) patients and cryptogenic ST-elevation myocardial infarction in one (1.4%), refractory migraine in one (1.4%), decompression sickness in one (1.4%), and orthodeoxia in one (1.4%) patient, respectively. All patients had demonstrated right-to-left shunting on bubble study. The procedures were guided by intracardiac echocardiography in 53%, transesophageal echocardiography in 39%, and the remainder by transthoracic echo alone. Devices used were the Amplatzer PFO Occluder (AGA Medical) (sizes 18-35 mm) in 49 (70%) and the Premere device (St. Jude Medical) in 21 (30%). In-hospital complications consisted of one significant groin hematoma with skin infection. Echocardiographic follow-up at 6 months revealed that most patients had no or trivial residual shunt (98.6%), while one patient (1.4%) had a mild residual shunt. At a median of 11 months' follow-up (range 1 month to 4.3 years), no patients (0%) experienced further CVA/TIAs or paradoxical embolic events during follow-up. CONCLUSION: PFO causing presumed paradoxical embolism can be closed percutaneously with a low rate of significant residual shunting and very few complications. Recurrent index events are uncommon at medium-term (up to 4 years) follow-up.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Chaque année, environ 1 à 1,25 million d’individus subiront une chirurgie cardiaque. [1] Environ 36 000 chirurgies cardiaques sont effectuées au Canada et 8000 procédures au Québec (http://www.ccs.ca). Le vieillissement de la population aura pour conséquence que la chirurgie cardiaque sera offerte à des patients de plus en plus à risque de complications, principalement en raison d’une co-morbidité plus importante, d’un risque de maladie coronarienne plus élevée, [2] d’une réserve physiologique réduite et par conséquent un risque plus élevé de mortalité à la suite d’une chirurgie cardiaque. L’une des complications significatives à la suite d’une chirurgie cardiaque est le sevrage difficile de la circulation extracorporelle. Ce dernier inclut la période au début du sevrage de la circulation extracorporelle et s’étend jusqu’au départ du patient de la salle d’opération. Lorsque le sevrage de la circulation extracorporelle est associé à une défaillance ventriculaire droite, la mortalité sera de 44 % à 86 %. [3-7] Par conséquent le diagnostic, l’identification des facteurs de risque, la compréhension du mécanisme, la prévention et le traitement du sevrage difficile de la circulation extracorporelle seront d’une importance majeure dans la sélection et la prise en charge des patients devant subir une chirurgie cardiaque. Les hypothèses de cette thèse sont les suivantes : 1) le sevrage difficile de la circulation extracorporelle est un facteur indépendant de mortalité et de morbidité, 2) le mécanisme du sevrage difficile de la circulation extracorporelle peut être approché d’une façon systématique, 3) la milrinone administrée par inhalation représente une alternative préventive et thérapeutique chez le patient à risque d’un sevrage difficile de la circulation extracorporelle après la chirurgie cardiaque.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Describir mediciones 3D y hallazgos estructurales de válvula mitral, en pacientes sanos, y con insuficiencia mitral grado 3 o 4, con enfermedad coronaria, patologías degenerativas o cardiopatía dilatada no isquémica, mediante uso de ecocardiografia transesofágica 3D en tiempo real.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introducción. La auriculilla izquierda es una estructura cardiaca que facilita la generación de trombos en su interior, favoreciendo la aparición de evento embolicos, por lo que su análisis a partir de imágenes bidimensionales y mas recientemente tridimensionales, adquieren cada vez mayor importancia Objetivo. Comparar los hallazgos anatómicos de la auriculilla izquierda obtenidos a través de la ecocardiografía tridimensional con respecto a los obtenidos por ecocardiografía bidimensional en un grupo de pacientes con ritmo sinusal y con fibrilación auricular. Métodos. Se trata de un estudio observacional analítico, transversal, en el que se compararan los resultados en las mediciones anatómicas obtenidas por ecocardiograma bidimensional en pacientes con rimo sinusal y fibrilación auricular, con los resultados de dichas mediciones obtenidas a través del ecocardiograma tridimensional en el mismo grupo de pacientes. Resultados. Se evaluaron 48 pacientes, 32 pacientes (66%) se encontraron en ritmo sinusal, la edad promedio fue de 58,2 años; 41,7% fueron mujeres y la mayoría, 32 pacientes (66,7%), tenían una o varias comorbilidades de importancia de riesgo cardiovascular, con evidencia de compromiso de la función sistólica en 20 paciente, encontrando una mayor homogeneidad en las variables área y profundidad de la auriculilla izquierda. Discusión. Los resultados nos permiten apoyar el concepto que las imágenes obtenidas por ecocardiografía tridimensional nos ofrecen una mejor evaluación de la auriculilla izquierda, observando una mayor homogeneidad con la ecocardiografía bidimensional en las variables área y profundidad, existiendo a su vez heterogeneidad en la variable longitud. Conclusión. El presente estudio demostró que la ecocardiografía tridimensional, es un aporte importante desde el punto de vista diagnostico tanto cualitativo como cuantitativo en el análisis de la auriculilla izquierda, permitiendo una fácil adquisición de imágenes en tiempo real y comparativas con las imágenes bidimensionales.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introducción: La enfermedad coronaria es la principal causa de muerte en Colombia y el mundo en personas mayores de 45 años (1, 2). Con la variación en los perfiles epidemiológicos se espera que aumente su prevalencia y costo, disminuyendo la mortalidad. En el estudio diagnóstico de enfermedad coronaria, se realizan múltiples pruebas paraclínicas, dentro de estas, el ecocardiograma es muy utilizado y sus recomendaciones de uso se basan en estudios de hace más de 10 años (3). Metodología: Se realizó un estudio de prueba diagnóstica para determinar las características operativas del ecocardiograma transtorácico para el diagnóstico de enfermedad coronaria frente al cateterismo cardiaco en pacientes con dolor torácico. Resultados: Se analizaron 290 pacientes con una edad promedio de 67 años y 68% hombres; el 74.1% tenía hipertensión arterial y el 24.5% de diabetes mellitus. En el 61% de los pacientes se evidenció enfermedad coronaria por angiografía. La sensibilidad del ecocardiograma transtorácico para enfermedad coronaria fue del 70%, especificidad del 55%, valor predictivo negativo del 54% y valor predictivo positivo del 71%; con una efectividad del 65% y una capacidad predictora del 60.6% (p=0.02). Discusión: La anatomía coronaria fue similar a la descrita previamente, siendo las lesiones multivaso presente en un 41% y la lesión de un vaso fue del 22% (4, 5). Teniendo en cuenta la sensibilidad del 70% y especificidad del 55%, la facilidad de acceso, características no invasivas y el bajo costo; nos permiten recomendar utilizarlo como guía diagnóstica en el contexto del dolor torácico en el servicio de urgencias.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Infection of implantable cardiac electronic devices in particular lead endocarditis (cardiac device infective endocarditis (CDIE)) is an emerging problem with significant morbidity, mortality and health care costs. The epidemiology is characterised with advanced age and health care association in cases presenting within 6 months of implantation. Risk factors include those of the patient, the procedure and the device. Staphylococcal species predominate as the causative organisms. Diagnosis is reliably made by blood cultures and transesophageal echocardiography. Complications include pulmonary and systemic emboli, persistent bacteremia and concomitant valvular involvement. Management includes complete device removal and prolonged antimicrobial therapy. With long-term follow-up to 1 year, the mortality of CDIE is as high as 23 %. It is associated with patient co-morbidities and concomitant valvular involvement and may be prevented by device removal during index admission.