104 resultados para Polysomnography


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Snoring is a primary and major clinical symptom of upper airway obstruction during sleep. Sleep-disordered breathing ranges from primary snoring to significant partial upper airway obstruction, and obstructive sleep apnea. Adult snoring and obstructive sleep apnea have been extensively studied, whereas less is known about these disorders in children. Snoring and more severe obstructive sleep apnea have been shown to have a harmful effect on the neurobehavioral development of children, but the mechanisms of this effect remains unknown. Furthermore, the correlation of this effect to objective sleep study parameters remains poor. This study evaluated the prevalence of snoring in preschool-aged children in Finland. Host and environmental risk factors, and neurobehavioral and neurocognitive symptoms of children suffering from snoring or obstructive sleep apnea were also investigated. The feasibility of acoustic rhinometry in young children was assessed. The prevalence and risk factors of snoring (I) were evaluated by a questionnaire. The random sample included 2100 children aged 1-6 years living in Helsinki. All 3- to 6-year-old children whose parents reported their child to snore always, often, or sometimes were categorized as snorers, and invited to participate to the clinical study (II-IV). Non-snoring children whose parents were willing to participate in the clinical study were invited to serve as controls. Children underwent a clinical ear-nose-throat examination. Emotional, behavioral, and cognitive performances were evaluated by Child Behavioral Checklist (CBCL), Wechsler Preschool and Primary Scale of Intelligence (WPPSI-R) and NEPSY-A Developmental Neuropsychological Assessment (NEPSY). Nasal volume was measured by acoustic rhinometry, and nasal resistance by rhinomanometry. Lateral and posteroanterior cephalometry were performed. A standard overnight ambulatory polysomnography was performed in the home environment. Twenty-six healthy children were tested in order to assess the feasibility of acoustic rhinometry in young children (V). Snoring was common in children; 6.3% of children snored always or often, whereas 81.3% snored never or occasionally. No differences were apparent between snorers and non-snorers regarding age, or gender. Pediatric snoring was associated with recurrent upper respiratory infections, otitis media, and allergic rhinitis. Exposure to parental tobacco smoke, especially maternal smoking, was more common among snorers. Rhinitis was more common among children who exposured to tobacco smoke. Overnight polysomnography (PSG) was performed on 87 children; 74% showed no signs of significant upper airway obstruction during sleep. Three children had obstructive apnea/hypopnea index (OAHI) greater than 5/h. Age, gender, or a previous adenoidectomy or tonsillectomy did not correlate with OAHI, whereas tonsillar size did correlate with OAHI. Relative body weight and obesity correlated with none of the PSG parameters. In cephalometry, no clear differences or correlations were found in PSG parameters or between snorers and non-snorers. No correlations were observed between acoustic rhinometry, rhinomanometry, and PSG parameters. Psychiatric symptoms were more frequent in the snoring group than in the nonsnoring group. In particular, anxious and depressed symptoms were more prevalent in the snoring group. Snoring children frequently scored lower in language functions. However, PSG parameters correlated poorly with neurocognitive test results in these children. This study and previous studies indicate that snoring without episodes of obstructive apnea or SpO2 desaturations may cause impairment in behavioral and neurocognitive functions. The mechanism of action remains unknown. Exposure to parental tobacco smoke is more common among snorers than non-snorers, emphasizing the importance of a smoke-free environment. Children tolerated acoustic rhinometry measurements well.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Os objetivos deste estudo foram avaliar o efeito do aparelho de avanço mandibular (Twin block - TB) no volume das vias aéreas superiores, por meio de tomografia computadorizada cone beam (CBCT); analisar, por meio da polissonografia, as mudanças no índice de apneia e hipopneia (IAH) e índice de apneia por hora de sono (IA), saturação de oxi-hemoglobina e eficiência do sono; e correlacionar o volume na CBCT e as polissonografias. Dezesseis pacientes portadores de apneia obstrutiva do sono, idade média de 47,06 anos, participaram deste estudo prospectivo, com acompanhamento médio de 7 meses. Foram feitas polissonografias iniciais (T1) e de acompanhamento (T2) com o TB em posição, e CBCT sem e com TB em posição. A segmentação e obtenção dos volumes das vias aéreas superiores foram realizadas e utilizados os testes t de Student pareado, de Wilcoxon e o índice de correlação de Spearman, com 5% de significância. Os resultados das polissonografias mostraram diferenças estatisticamente significativas entre T1 e T2 apenas para IAH (p<0,05). Houve aumento do volume da via aérea superior com TB quando comparado com o volume sem TB (p<0,05). Foi possível estabelecer-se correlação positiva entre volume da via aérea superior sem TB e IAH e IA em T1 (p<0,05), mas não houve correlação entre o volume da via aérea com TB e índices polissonográficos em T2. Pode-se concluir que, houve aumento de volume da via aérea superior com o TB e houve redução do IAH em T2 porém, sem correlação entre estes dados.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Sleep Disordered Breathing (SDB) is a highly prevalent condition associated with orofacial and dentofacial characteristics.Objective: the aim of this study was to verify the association of dental malocclusion, molar relationship, crossbite, open bite, overjet, overbite, and crowding with SDB in children aged 7-9 years.Materials and methods: Participating schools were selected randomly from within the public elementary school system. in the first phase of the study, the parents of 1216 children aged between 7 and 9 years old completed the Sleep Disturbance Scale for Children (SDSC) questionnaire and the children had to participate in a dental examination. the evaluation of occlusion was divided into sagittal analysis, vertical analysis, and transverse analysis. in the second phase, 60 children were selected randomly to be undergone polysomnography (PSG) at a sleep clinic.Results: Among the children included, 242 (19.9%) children had normal occlusion. of the 60 children, 50 underwent PSG and 40(80%) had SDB. the crossbite and open bite showed association with SDB, p = 0.04 in both.Conclusion: Crossbite and open bite malocclusions were associated with SDB, and may be predictive of SDB in children. Studies with larger numbers of participants are needed to investigate the association of other malocclusions with SDB, and randomized clinical trials are also needed to see whether orthodontic and/or functional jaw orthopedic treatment is an option for treating children with malocclusion and SDB. (C) 2014 Elsevier Ireland Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tese de mestrado, Ciências do Sono, Faculdade de Medicina, Universidade de Lisboa, 2015

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RESUMO: A hipertensão arterial (HA) é uma patologia altamente prevalente, embora claramente subdiagnosticada, em doentes com síndrome de apneia obstrutiva do sono (SAOS). Estas duas patologias apresentam uma estreita relação e a monitorização ambulatória da pressão arterial (MAPA), por um período de 24 horas, parece ser o método mais preciso para o diagnóstico de hipertensão em doentes com SAOS. No entanto, esta ferramenta de diagnóstico para além de ser dispendiosa e envolver um número acrescido de meios técnicos e humanos, é mais morosa e, por conseguinte, não é utilizada por rotina no contexto do diagnóstico da SAOS. Por outro lado, apesar da aplicação de pressão positiva contínua nas vias aéreas (CPAP – Continous Positive Airway Pressure) ser considerada a terapêutica de eleição para os doentes com SAOS, o seu efeito no abaixamento da pressão arterial (PA) parece ser modesto, exigindo, por conseguinte, a implementação concomitante de terapêutica anti-hipertensora. Acontece que são escassos os dados relativos aos regimes de fármacos anti-hipertensores utilizados em doentes com SAOS e, acresce ainda que, as guidelines terapêuticas para o tratamento farmacológico da HA, neste grupo particular de doentes, permanecem, até ao momento, inexistentes. A utilização de modelos animais de hipóxia crónica intermitente (CIH), que mimetizam a HA observada em doentes com SAOS, revela-se extremamente importante, uma vez que se torna imperativo identificar fármacos que promovam um controle adequado da PA neste grupo de doentes. No entanto, estudos concebidos com o intuito de investigar o efeito anti-hipertensor dos fármacos neste modelo animal revelam-se insuficientes e, por outro lado, os escassos estudos que testaram fármacos anti-hipertensores neste modelo não foram desenhados para responder a questões de natureza farmacológica. Acresce ainda que se torna imprescindível garantir a escolha de um método para administração destes fármacos que seja não invasivo e que minimize o stress do animal. Embora a gavagem seja uma técnica indiscutivelmente eficaz e amplamente utilizada para a administração diária de fármacos a animais de laboratório, ela compreende uma sequência de procedimentos geradores de stress para os animais e, que podem por conseguinte, constituir um viés na interpretação dos resultados obtidos. O objectivo global da presente investigação translacional foi contribuir para a identificação de fármacos anti-hipertensores mais efectivos para o tratamento da HT nos indivíduos com SAOS e investigar mecanismos subjacentes aos efeitos sistémicos associadas à SAOS bem como a sua modulação por fármacos anti-hipertensores. Os objectivos específicos foram: em primeiro lugar,encontrar novos critérios, baseados nas medidas antropométricas, que permitam a identificação de doentes com suspeita de SAOS, que erroneamente se auto-classifiquem como nãohipertensos, e desta forma promover um uso mais criterioso do MAPA; em segundo lugar, investigar a existência de uma hipotética associação entre os esquemas de fármacos antihipertensores e o controle da PA (antes e após a adaptação de CPAP) em doentes com SAOS em terceiro lugar, avaliar a eficácia do carvedilol (CVD), um fármaco bloqueador β-adrenérgico não selectivo com actividade antagonista α1 intrínseca e propriedades anti-oxidantes num modelo animal de hipertensão induzida pela CIH; em quarto lugar, explorar os efeitos da CIH sobre o perfil farmacocinético do CVD; e, em quinto lugar, investigar um método alternativo à gavagem para a administração crónica de fármacos anti-hipertensores a animais de laboratório. Com este intuito, na primeira fase deste projecto, fizemos uso de uma amostra com um número apreciável de doentes com SAOS (n=369), que acorreram, pela primeira vez, à consulta de Patologia do Sono do CHLN e que foram submetidos a um estudo polissonográfico do sono, à MAPA e que preencheram um questionário que contemplava a obtenção de informação relativa ao perfil da medicação anti-hipertensora em curso. Numa segunda fase, utilizámos um modelo experimental de HT no rato induzida por um paradigma de CIH. Do nosso trabalho resultaram os seguintes resultados principais: em primeiro lugar, o índice de massa corporal (IMC) e o perímetro do pescoço (PP) foram identificados como preditores independentes de “auto-classificação errónea” da HA em doentes com suspeita de SAOS; em segundo lugar, não encontramos qualquer associação com significado estatístico entre os vários esquemas de fármacos anti-hipertensores bem como o número de fármacos incluídos nesse esquemas, e o controle da PA (antes e depois da adaptação do CPAP); em terceiro lugar, apesar das doses de 10, 30 e 50 mg/kg de carvedilol terem promovido uma redução significativa da frequência cardíaca, não foi observado qualquer decréscimo na PA no nosso modelo animal; em quarto lugar, as razões S/(R+S) dos enantiómeros do CVD nos animais expostos à CIH e a condições de normóxia revelaram-se diferentes; e, em quinto lugar, a administração oral voluntária mostrou ser um método eficaz para a administração diária controlada de fármacos anti-hipertensores e que é independente da manipulação e contenção do animal. Em conclusão, os resultados obtidos através do estudo clínico revelaram que o controle da PA, antes e após a adaptação do CPAP, em doentes com SAOS é independente, quer do esquema de fármacos anti-hipertensores, quer do número de fármacos incluídos num determinado esquema. Os nossos resultados salientam ainda a falta de validade da chamada self-reported hypertension e sugerem que em todos os doentes com suspeita de SAOS, com HA não diagnosticada e com um IMC e um PP acima de 27 kg/m2 e 39 cm, respectivamente, a confirmação do diagnóstico de HA deverá ser realizada através da MAPA, ao invés de outros métodos que com maior frequência são utilizados com este propósito. Os resultados obtidos no modelo animal de HA induzida pela CIH sugerem que o bloqueio do sistema nervoso simpático, juntamente com os supostos efeitos pleiotrópicos do CVD, não parece ser a estratégia mais adequada para reverter este tipo particular de hipertensão e indicam que as alterações farmacocinéticas induzidas pela CIH no ratio S/(R+S) não justificam a falta de eficácia anti-hipertensora do CVD observada neste modelo animal. Por último, os resultados do presente trabalho suportam ainda a viabilidade da utilização da administração oral voluntária, em alternativa à gavagem, para a administração crónica de uma dose fixa de fármacos anti-hipertensores.---------------------------- ABSTRACT: Hypertension (HT) is a highly prevalent condition, although under diagnosed, in patients with obstructive sleep apnea (OSA). These conditions are closely related and 24-hour ambulatory blood pressure monitoring (ABPM) seems to be the most accurate measurement for diagnosing hypertension in OSA. However, this diagnostic tool is expensive and time-consuming and, therefore, not routinely used. On the other hand, although continuous positive airway pressure (CPAP) is considered the gold standard treatment for symptomatic OSA, its lowering effect on blood pressure (BP) seems to be modest and, therefore, concomitant antihypertensive therapy is still required. Data on antihypertensive drug regimens in patients with OSA are scarce and specific therapeutic guidelines for the pharmacological treatment of hypertension in these patients remain absent. The use of animal models of CIH, which mimic the HT observed in patients with OSA, is extremely important since it is imperative to identify preferred compounds for an adequate BP control in this group of patients. However, studies aimed at investigating the antihypertensive effect of antihypertensive drugs in this animal model are insufficient, and most reports on CIH animal models in which drugs have been tested were not designed to respond to pharmacological issues. Moreover, when testing antihypertensive drugs (AHDs) it becomes crucial to ensure the selection of a non-invasive and stress-free method for drug delivery. Although gavage is effective and a widely performed technique for daily dosing in laboratory rodents, it comprises a sequence of potentially stressful procedures for laboratory animals that may constitute bias for the experimental results. The overall goal of the present translational research was to contribute to identify more effective AHDs for the treatment of hypertension in patients with OSA and investigate underlying mechanisms of systemic effects associated with OSA, as well as its modulation by AHDs. The specific aims were: first, to find new predictors based on anthropometric measures to identify patients that misclassify themselves as non-hypertensive, and thereby promote the selective use of ABPM; second, to investigate a hypothetical association between ongoing antihypertensive regimens and BP control rates in patients with OSA, before and after CPAP adaptation; third, to determine, in a rat model of CIH-induced hypertension, the efficacy of carvedilol (CVD), a nonselective beta-blocker with intrinsic anti-α1-adrenergic activity and antioxidant properties; fourth, to explore the effects of CIH on the pharmacokinetics profile of CVD and fifth, to investigate an alternative method to gavage, for chronic administration of AHDs to laboratory rats. For that, in the first phase of this project, we used a sizeable sample of patients with OSA (n=369), that attended a first visit at Centro Hospitalar Lisboa Norte, EPE Sleep Unit, and underwent overnight polysomnography, 24-h ABPM and filled a questionnaire that included ongoing antihypertensive medication profile registration. In the second phase, a rat experimental model of HT induced by a paradigm of CIH that simulates OSA was used. The main findings of this work were: first, body mass index (BMI) and neck circumference (NC) were identified as independent predictors of hypertension misclassification in patients suspected of OSA; second, in patients with OSA, BP control is independent of both the antihypertensive regimen and the number of antihypertensive drugs, either before or after CPAP adaptation; third, although the doses of 10, 30 and 50 mg/Kg of CVD promoted a significant reduction in heart rate, no decrease in mean arterial pressure was observed; fourth, the S/(R+S) ratios of CVD enantiomers, between rats exposed to CIH and normoxic conditions, were different and fifth, voluntary ingestion proved to be an effective method for a controlled daily dose administration, with a define timetable, that is independent of handling and restraint procedures. In conclusion, the clinical study showed that BP control in OSA patients is independent of both the antihypertensive regimen and the number of antihypertensive drugs. Additionally, our results highlight the lack of validity of self-reported hypertension and suggest that all patients suspected of OSA with undiagnosed hypertension and with a BMI and NC above 27 Kg/m2 and 39 cm should be screened for hypertension, through ABPM. The results attained in the rat model of HT related to CIH suggest that the blockade of the sympathetic nervous system together with the putative pleiotropic effects of carvedilol is not able to revert hypertension induced by CIH and point out that the pharmacokinetic changes induced by CIH on S/(R+S) ratio are not apparently responsible for the lack of efficacy of carvedilol in reversing this particular type of hypertension. Finally, the results here presented support the use of voluntary oral administration as a viable alternative to gavage for chronic administration of a fixed dose of AHDs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sleep spindles are synchronized 11-15 Hz electroencephalographic (EEG) oscillations predominant during nonrapid-eye-movement sleep (NREMS). Rhythmic bursting in the reticular thalamic nucleus (nRt), arising from interplay between Ca(v)3.3-type Ca(2+) channels and Ca(2+)-dependent small-conductance-type 2 (SK2) K(+) channels, underlies spindle generation. Correlative evidence indicates that spindles contribute to memory consolidation and protection against environmental noise in human NREMS. Here, we describe a molecular mechanism through which spindle power is selectively extended and we probed the actions of intensified spindling in the naturally sleeping mouse. Using electrophysiological recordings in acute brain slices from SK2 channel-overexpressing (SK2-OE) mice, we found that nRt bursting was potentiated and thalamic circuit oscillations were prolonged. Moreover, nRt cells showed greater resilience to transit from burst to tonic discharge in response to gradual depolarization, mimicking transitions out of NREMS. Compared with wild-type littermates, chronic EEG recordings of SK2-OE mice contained less fragmented NREMS, while the NREMS EEG power spectrum was conserved. Furthermore, EEG spindle activity was prolonged at NREMS exit. Finally, when exposed to white noise, SK2-OE mice needed stronger stimuli to arouse. Increased nRt bursting thus strengthens spindles and improves sleep quality through mechanisms independent of EEG slow waves (<4 Hz), suggesting SK2 signaling as a new potential therapeutic target for sleep disorders and for neuropsychiatric diseases accompanied by weakened sleep spindles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A low arousal threshold is believed to predispose to breathing instability during sleep. The present authors hypothesised that trazodone, a nonmyorelaxant sleep-promoting agent, would increase the effort-related arousal threshold in obstructive sleep apnoea (OSA) patients. In total, nine OSA patients, mean+/-sd age 49+/-9 yrs, apnoea/hypopnoea index 52+/-32 events.h(-1), were studied on 2 nights, one with trazodone at 100 mg and one with a placebo, in a double blind randomised fashion. While receiving continuous positive airway pressure (CPAP), repeated arousals were induced: 1) by increasing inspired CO(2) and 2) by stepwise decreases in CPAP level. Respiratory effort was measured with an oesophageal balloon. End-tidal CO(2 )tension (P(ET,CO(2))) was monitored with a nasal catheter. During trazodone nights, compared with placebo nights, the arousals occurred at a higher P(ET,CO(2)) level (mean+/-sd 7.30+/-0.57 versus 6.62+/-0.64 kPa (54.9+/-4.3 versus 49.8+/-4.8 mmHg), respectively). When arousals were triggered by increasing inspired CO(2) level, the maximal oesophageal pressure swing was greater (19.4+/-4.0 versus 13.1+/-4.9 cm H(2)O) and the oesophageal pressure nadir before the arousals was lower (-5.1+/-4.7 versus -0.38+/-4.2 cm H(2)O) with trazodone. When arousals were induced by stepwise CPAP drops, the maximal oesophageal pressure swings before the arousals did not differ. Trazodone at 100 mg increased the effort-related arousal threshold in response to hypercapnia in obstructive sleep apnoea patients and allowed them to tolerate higher CO(2) levels.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVES: Obstructive sleep apnea is associated with significantly increased cardiovascular morbidity and mortality. Fluid overload may promote obstructive sleep apnea in patients with ESRD through an overnight fluid shift from the legs to the neck soft tissues. Body fluid shift and severity of obstructive sleep apnea before and after hemodialysis were compared in patients with ESRD. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: Seventeen patients with hemodialysis and moderate to severe obstructive sleep apnea were included. Polysomnographies were performed the night before and after hemodialysis to assess obstructive sleep apnea, and bioimpedance was used to measure fluid overload and leg fluid volume. RESULTS: The mean overnight rostral fluid shift was 1.27±0.41 L prehemodialysis; it correlated positively with fluid overload volume (r=0.39; P=0.02) and was significantly lower posthemodialysis (0.78±0.38 L; P<0.001). There was no significant difference in the mean obstructive apnea-hypopnea index before and after hemodialysis (46.8±22.0 versus 42.1±18.6 per hour; P=0.21), but obstructive apnea-hypopnea index was significantly lower posthemodialysis (-10.1±10.8 per hour) in the group of 12 patients, with a concomitant reduction of fluid overload compared with participants without change in fluid overload (obstructive apnea-hypopnea index +8.2±16.1 per hour; P<0.01). A lower fluid overload after hemodialysis was significantly correlated (r=0.49; P=0.04) with a lower obstructive apnea-hypopnea index. Fluid overload-assessed by bioimpedance-was the best predictor of the change in obstructive apnea-hypopnea index observed after hemodialysis (standardized r=-0.68; P=0.01) in multivariate regression analysis. CONCLUSIONS: Fluid overload influences overnight rostral fluid shift and obstructive sleep apnea severity in patients with ESRD undergoing intermittent hemodialysis. Although no benefit of hemodialysis on obstructive sleep apnea severity was observed in the whole group, the change in obstructive apnea-hypopnea index was significantly correlated with the change in fluid overload after hemodialysis. Moreover, the subgroup with lower fluid overload posthemodialysis showed a significantly lower obstructive sleep apnea severity, which provides a strong incentive to further study whether optimizing fluid status in patients with obstructive sleep apnea and ESRD will improve the obstructive apnea-hypopnea index.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of the current undertaking was to study the electrophysiological properties of the sleep onset period (SOP) in order to gain understanding into the persistent sleep difficulties of those who complain of insomnia following mild traumatic brain injury (MTBI). While many believe that symptoms of post concussion syndrome (PCS) following MTBI resolve within 6 to 12 months, there are a number of people who complain of persistent sleep difficulty. Two models were proposed which hypothesize alternate electrophysiological presentations of the insomnia complaints of those sustaining a MTBI: 1) Analyses of standard polysomnography (PSG) sleep parameters were conducted in order to determine if the sleep difficulties of the MTBI population were similar to that of idiopathic insomniacs (i.e. greater proportion ofREM sleep, reduced delta sleep); 2) Power spectral analysis was conducted over the SOP to determine if the sleep onset signature of those with MTBI would be similar to psychophysiological insomniacs (characterized by increased cortical arousal). Finally, exploratory analyses examined whether the sleep difficulties associated with MTBI could be explained by increases in variability of the power spectral data. Data were collected from 9 individuals who had sustained a MTBI 6 months to 5 years earlier and reported sleep difficulties that had arisen within the month subsequent to injury and persisted to the present. The control group consisted of 9 individuals who had experienced neither sleep difficulties, nor MTBI. Previous to spending 3 consecutive uninterrupted nights in the sleep lab, subjects completed questionnaires regarding sleep difficulties, adaptive functioning, and personality.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Le premier objectif de cette étude était d’évaluer la relation entre l’alexithymie et différents troubles du sommeil chez des patients diagnostiqués (N= 580) selon la polysomnographie et la classification de l’American Academy of Sleep Medicine (AASM) et chez des sujets contrôle (N= 145) en utilisant l’Échelle d’Alexithymie de Toronto à 20 items (TAS-20). Le deuxième objectif était d’estimer le lien entre l’alexithymie et des caractéristiques de rêves suivant un Questionnaire sur les Rêves de 14 items. Les résultats confirment un lien entre l’alexithymie et les troubles du sommeil. Sa prévalence était supérieure dans le groupe clinique comparativement au groupe contrôle, et était différente selon les troubles. Les hommes cotaient plus haut que les femmes à l’Échelle d’Alexithymie de Toronto à 20 items (TAS-20) et sur ses sous-échelles DDF (difficulty describing feeling) et EOT (externally oriented thinking). L’EOT pourrait être impliquée dans les troubles de sommeil en étant l’unique sous-échelle, où un effet principal des diagnostics était significatif dans le groupe clinique. Pour les rêves, le score du TAS-20 corrélait positivement avec le facteur « détresse des cauchemars »; et négativement avec « rappel de rêves » et « signification des rêves ». Les sous-échelles du TAS-20 avaient des corrélations différentes: positive entre DIF et « détresse des cauchemars », négative entre DDF et « rappel de rêves » et EOT avec « signification des rêves ». À part quelques exceptions, ces modèles sont obtenus pour les groupes cliniques et non-cliniques, et pour les hommes et les femmes dans ces deux groupes. Ces résultats suggèrent un modèle consistant, et reproductible, de relations entre l’alexithymie et les composantes des rêves.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La schizophrénie découle d’une modification du fonctionnement du cerveau et entraîne divers symptômes qui ont pour conséquence une altération de la perception de la réalité, des troubles cognitifs, et des dysfonctionnements sociaux et comportementaux. En plus des observations cliniques de jour, la schizophrénie montre également des signes nocturnes qui peuvent se manifester durant le rêve. Cette thèse vise à caractériser les rêves dans la schizophrénie et cherche à explorer les relations qui existent entre les caractéristiques du contenu onirique des personnes atteintes de schizophrénie et les symptômes de cette maladie. Pour ce faire, nous avons comparé diverses mesures de l’activité onirique recueillies auprès de 14 participants atteints de schizophrénie traités sous antipsychotiques atypiques et 15 participants témoins par le biais de questionnaires et de collectes de rêves en laboratoire à la suite d’éveils provoqués en sommeil paradoxal (SP) et en sommeil lent (SL). Les résultats obtenus au questionnaire révèlent que les participants atteints de schizophrénie rapportent un nombre de cauchemars plus élevé comparativement aux participants témoins. Les collectes en laboratoire démontrent une fréquence de rappel de rêves équivalente au sein des deux groupes de participants, indépendamment du stade de sommeil durant lequel elles sont effectuées. Les récits de rêves du SL des deux groupes de participants sont généralement plus courts et comprennent un nombre moins élevé d’items quantifiables comparativement à ceux du SP. Les récits de rêves recueillis en SP et en SL chez les participants atteints de schizophrénie s’avèrent plus courts que ceux des participants témoins et, lorsque le nombre de mots est pondéré, la plupart des différences observées dans le contenu de rêve entre les deux groupes tendent à disparaître. En comparaison aux participants témoins, ceux atteints de schizophrénie évaluent leurs rêves comme étant moins bizarres, en dépit d’un nombre équivalent d’éléments bizarres dans leurs récits. Finalement, bien qu’il n’y ait pas de différence dans la densité des mouvements oculaires rapides (MORs) entre les deux groupes de participants, seuls les participants témoins montrent une corrélation positive entre les MORs et certaines variables du contenu onirique. Les résultats de la présente thèse suggèrent que les caractéristiques du contenu onirique des personnes atteintes de schizophrénie peuvent refléter certaines des manifestations psychopathologiques de cette maladie.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Le traitement de première ligne de l’apnée obstructive du sommeil est l’appareil à pression positive, soit le CPAP, qui est le plus souvent utilisé avec un masque nasal. Certains patients, incapables de tolérer le masque nasal, doivent se tourner vers le masque facial, qui peut parfois requérir une pression supérieure à celle utilisée avec le masque nasal pour éliminer tous les événements respiratoires. Nous supposons que l’ajustement serré du masque facial, dans le but de réduire les fuites, entraîne une pression de recul sur la mandibule; ceci diminuerait le calibre des voies aériennes supérieures, nécessitant donc une pression effective thérapeutique supérieure pour rétablir un passage de l’air. Nos objectifs étaient : 1) de démontrer s’il y avait une différence de pression effective entre le masque nasal et le masque facial, 2) de quantifier la fuite entre les deux masques, 3) d’évaluer l’effet d’une orthèse de rétention mandibulaire neutre (OMN), qui empêche le recul mandibulaire, sur la pression effective des deux masques et 4) d’évaluer s’il existait un lien entre la céphalométrie et les réponses variables des individus. Méthodologie : Lors de cette étude expérimentale croisée, huit sujets (2 femmes, 6 hommes) avec une moyenne d’âge de 56,3ans [33ans-65ans] ont reçu un examen orthodontique complet incluant une radiographie céphalométrique latérale. Ils ont ensuite passé deux nuits de polysomnographie au laboratoire du sommeil en protocole « split-night » où les deux masques ont été portés, seuls, la première nuit, et avec l’OMN, la deuxième nuit. Résultats : Nous avons trouvé que la pression effective thérapeutique était supérieure avec le masque facial comparativement au masque nasal de manière statistiquement significative. Nous avons observé une fuite supérieure avec le masque nasal, ce qui permet de dire que la fuite n’explique probablement pas cette différence de pression entre les deux masques. L’OMN n’a pas donné d’effet statistiquement significatif lorsque combinée au masque nasal, mais il aurait probablement été possible de trouver un effet positif avec le masque facial si le Bi-PAP avait été inclus dans le protocole de recherche. Conclusion : Nos résultats ne permettent pas de confirmer le rôle du recul mandibulaire, causé par la force exercée avec le masque facial, dans l’obtention de pressions supérieures avec ce masque, mais nous ne pouvons toutefois pas éliminer l’hypothèse. Les résultats suggèrent également que ce phénomène est peut-être plus fréquent qu’on ne le croit et qu’il pourrait y avoir un lien avec certains facteurs anatomiques individuels.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectifs : Le bruxisme survenant au cours du sommeil est un trouble du mouvement caractérisé par du grincement de dents et l’activité rythmique des muscles masticateurs (ARMM). Le bruxisme/ARMM est souvent associé à des mouvements du corps et des à éveils corticaux. Une séquence d’activation précède le ARMM/bruxisme. Ces événements incluent une augmentation des variables suivants : l’activité sympathique (-4 minutes), les activités encéphalographique (-4 second), le fréquence cardiaque, l’amplitude de la respiration (-1 second) et l’activité des muscle suprahyoïdiens (-0.8 second). La présente étude a examiné l’association entre le bruxisme et les changements de la pression artérielle. Méthodes: Dix sujets avec le bruxisme (5 hommes, 5 femmes, âge moyen = 26 ± 1,8) ont complétés 3 nuits de polysomnographie qui comprenait l'enregistrement non invasive de la pression artérielle. La première nuit a servi de dépistage et d’habituation au laboratoire. L'analyse a été réalisée sur les deuxièmes et troisièmes nuits enregistrements. Seuls les épisodes de bruxisme isolés survenant au cours du stade 2 du sommeil ont été utilisés pour l’analyse, pour un total de 65 épisodes. Les mesures des pressions systolique et diastolique ont été prises 20 battements avant et 23 battements après l'apparition de chaque épisode bruxisme lors du sommeil. Les épisodes de bruxisme ont été classés comme suit: 1) bruxisme avec éveil cortical; 2) bruxisme avec mouvement du corps (MC), 3) bruxisme avec éveil cortical et MC. Une quatrième catégorie, bruxisme seul, a également été analysée, mais utilisée comme donnée préliminaire puisque la catégorie se composait de seulement 4 épisodes de bruxisme. Résultats: Les deux pressions systolique et diastolique ont augmenté avec les épisodes de bruxisme. Cette augmentation a été statistiquement significative pour la pression systolique et diastolique pour les épisodes de bruxisme avec éveil cortical et/ou MC (p ≤ 0,05). L’augmentation moyenne de la pression (systolique / diastolique ± SE) a été : 28,4 ± 2,4/13,2 ± 1,5 mm Hg pour le bruxisme avec éveil cortical; 30,7 ± 1,6/19.4 ± 2.3 mm Hg pour bruxisme avec MC; 26.4 ± 2,8 / 14,6 ± 2.0mm Hg pour bruxisme avec éveil cortical et MC; 22,9 ± 5,2/12,4 ± 3,3mm Hg pour les épisodes de bruxisme seuls. Conclusion: Le bruxisme du sommeil est associé à des hausses de la pression artérielle pendant le sommeil. Cette hausse est supérieure dans les épisodes de bruxisme associés à un éveil cortical et / ou MC, qui sont souvent associés avec les événements bruxisme. Ces résultats sont en accord avec nos observations antérieures, où le bruxisme est précédé par une augmentation de l'activité sympathique et de la tachycardie sinusale.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Le syndrome des impatiences musculaires de l’éveil (SIME) est un trouble sensitivo-moteur causant des perturbations du sommeil. Il fut décrit que ce syndrome est plus fréquent chez les sujets vivant avec la sclérose en plaques (SEP) que dans la population générale. L’objectif principal de ce travail est de décrire l’impact du SIME sur le sommeil des sujets avec la sclérose en plaques, comparé au sommeil de sujets avec la SEP, mais sans SIME. Des questionnaires validés et des études de polysomnographie seront utilisés pour réaliser nos objectifs. Les études de PSG de nos 49 sujets révèlent qu’indépendamment de la présence ou de l’absence du SIME, le sommeil des sujets avec la SEP est grandement perturbé. De plus, même en l’absence du SIME, les sujets avec la SEP présentent des mouvements périodiques des jambes. Cette étude démontre que le SIME se manifeste différemment dans la SEP. De plus amples recherches sont nécessaires pour mieux caractériser le SIME en SEP.